You are on page 1of 1
BASIN 3 LIQUID BULK TERMINAL, Sokhna Port, Egypt are. Sonker “2 ‘S = surface area to be protected [4.70 m2 for inlet and for Outlet Water Boxes} CB = coating breakdown (initial=0.020, average=0.040, final=0.060) Considering the above symbology and carrying out the calculations for the initial, average and final life of cathodic protection system, the protection currents shall be: PROTECTION CURRENT Initial life value | Average life value | Final life value Inlet Water Box 47 mA 94 mA 141 mA, Outlet Water Box 47 mA 94 mA 141 mA, 43 — Sacrificial Anodes 4.3.1 Anodes type For the cathodic protection system, the following type of anode have been selected ALONINTM ROD | | diam. 60 mn PLASTIC SLEEVE tenth. 150° mm The anodic mass able to supply the protection current (aluminium rod out of plastic sleeve) has a weight of 1.17 kg ATEC, Italy Page 10 ATC-ME-CAL-0007-C01 © ILF 2016