You are on page 1of 4

Job No.

Heat Treatment Report

DEMO20

Report No.

001

Page:

Heat Treatment Date

1 of 1

Chart No.

INPEC Procedure No.

Furnace/Local - PWHT

Thermocouple S/N

Local-PWHT

Recorder S/N

Parameters

Required

Actual

600-650 C

630 C

60 min.up to 2"(1.5 min./1" over 2")

70 min.

Heating Rate (C/hr)

220 C max.

200 C

Cooling Rate (C/hr)

220 C max.

200 C

Holding Temp. (C)


Holding Time (minutes)

Other

S.No.

Dwg. No.

Spool / Item No.

INPEC-DEMO2012-U1 Rev.(0) Sheet 1/1

M
A
S

Remarks

E
L
P

10

11

12
A sketch describes the placement of thermocouples must be attached to this report.
Prepared By

Approved By

Name :

Name :

Title

Title :

: Heat Treatment Operator

Signature / Date :
ASME Q. C. Manual

Accepted By
Name :

QC Inspector

Title

Signature / Date :
Exhibit No. (38)

: : QC Manager

Signature / Date :
Rev.: 0

Date:01/09/2012

Job No.

Heat Treatment Report

Report No.

Page:

Placement of Thermocouples Sketch

Thermocouple No. 1

120

120

120
Thermocouple No. 3
Thermocouple No. 2

ASME Q. C. Manual

Exhibit No. (38)

Rev.: 0

Date:01/09/2012

o this report.

DEMO2012
001
1 of 1

Local-PWHT

Actual
630 C
70 min.
200 C
200 C

Remarks

DEMO2012
001

2 of 2

Date:01/09/2012

You might also like