HZ
VRF
Variable Refrigerant Flow System
CATALOGUE
HEAT PUMP
for UAE
CREATION
OF COMFORT
OUR SOLUTION FOR ALL PROPERTIES .............................. 4
2017 NEW PRODUCTS .................................................... 6
Light Commercial Solutions ........................................... 8
Commercial Solutions .................................................. 10
VENTILATION
Energy Recovery Ventilator ......................................... 110
Outdoor Air Unit ......................................................... 112
Heat Pump Modular type for heating or cooling operation Heat Pump Modular type for heating or cooling operation Heat Pump type for heating or cooling operation
DX-Kit for air handling applications ............................ 114
AIRSTAGETM OPTION
Production by order
Auto Louver Grille Kit .................................................. 117
8 HP - 54 HP 39 Models 8 HP - 42 HP 18 Models 4 HP - 6 HP 6 Models OPTIONAL PARTS LIST ................................................. 118
OPTIONAL PARTS ....................................................... 120
• Space saving combination: 8 HP to 54 HP/24 models • Space saving combination: 8 HP to 42 HP/15 models • Single phase: 4 HP to 6 HP/3 models
• Energy efficiency combination: 16 HP to 46 HP/15 models • Energy efficiency combination: 24 HP to 28 HP/3 models • 3 phase: 4 HP to 6 HP/3 models
ABOUT US
SUPPORT
AIRSTAGE™ SUPPORT .................................................. 138
AIRSTAGE™ / RAC SUPPORT TOOL ................................ 140
QUICK SERVICE & MAINTENANCE ................................. 142
SERVICE TOOL ............................................................. 144
WEB MONITORING TOOL ............................................. 145
2 3
OUR SOLUTION FOR ALL PROPERTIES
Fujitsu General provides the best solutions suitable for properties.
High
gh Enhanced
En
nhanced
We provide single and modular type VRF
Durability
urability Safety
Safet
afety
systems designed for high efficiency,
comfort, freedom of design, easy installation
and high reliability.
4 5
2017 NEW PRODUCTS
Centralized Control
Touch Panel Controller System Controller Software
• Up to 400 indoor units can be controlled
System Controller Lite Software
• Control and monitor Fujitsu’s air conditioner via LAN or Internet. • Up to a maximum of 4 VRF network systems, 1600 indoor
• Easy maintenance & installation units, and 400 outdoor units can be controlled.*
• Simple BMS, 3rd party supported by Modbus communication
can be controlled.
TROPICAL series
Hardware
6 7
Light Commercial Solutions
APARTMENT, VILLA
Fujitsu General offers the small VRF system to TROPICAL series
match from large living rooms to bedrooms
for apartment and villa.
VILLA
Indoor unit
Transmission line
VRF system
EEV unit
DX-Kit
Wired R.C.
Thermistor
eiling mode
High ceiling
sette can be
This cassette
3.2m
3.2m
m
air conditioner. This is useful in energy saving management
over the whole building. VRF 2m
indoor
NEW units High
h ceiling
ceilin
ng mode
System
Controller Lite 4.2m
4.2
2m 3m
TROPICAL series
8 HP - 42 HP 18 Models Facilities 4m
• Space saving combination: 8 HP to 42 HP / 15 models Lightning Ventilation Energy Recovery
• Energy efficiency combination: 24 HP to 28 HP / 3 models Ventilator
10 11
AIRSTAGE VRF SYSTEMS CAN BE DESIGNED TO
TM
AIRSTAGE
TM
HIGH ENERGY EFFICIENCY
DESIGN FLEXIBILITY
MORE COMFORT
EASY INSTALLATION
12 13
AIRSTAGE CORE TECHNOLOGY
TM
limitation 28
26
24
The minimum and maximum temperature ranges can be
limited, which provide further energy saving while maintaining 22
27%UP 14%UP
4.33
5
3.88
3.42 3.40
4
Capacity save operation Setting
Capacity
Capacity save
range
3
Operation capacity can be set in 5 steps for rated capability.
2 The power consumption at peak is cut down and the maximum 100% Setting
level
load is suppressed. 80%
10
60%
DUCT DUCT 40%
Split Tropical series Split Tropical series
0%
4HP class 6HP class
Time
14 15
AIRSTAGE CORE TECHNOLOGY
TM
Note: Rotational operation is alternated by the start / stop timing of the compressor.
Backup operation
If one compressor fails, backup operation will be performed by
*: Note: Backup operation may not be possible depending on the trouble state.
Take special notice of the following in order to enhance the anti-corrosion effect.
• Keep the unit free of direct sea breeze as much as possible by installing a windshield plate or placing the unit on the leeward side of the building.
• Arrange the unit so that any salt attached to the enclosure can be washed away by rain. Oil Recovery operation
• Any water left on the bottom of the outdoor unit can increase corrosion. To prevent interference with the water drain, be careful of the tilting angle of the unit.
• Wash the enclosure regularly with water to remove any salt attached. Periodic oil recovery operation is done automatically in order to
• Repair any damages on the unit (i.e. scratches) caused during installation or maintenance.
• Check the condition of the unit regularly. (If necessary, retreat the unit for anti-corrosion or make parts replacements.)
feed back oil from the indoor unit to compressor.
• Make sure the drainage is secured at the foundation.
16 17
AIRSTAGE CORE TECHNOLOGY
TM
DESIGN FLEXIBILITY
High static pressure
The outdoor unit can have a condenser hood easily connected with a static pressure of 80Pa to 82Pa.
This allows outdoor units to be installed within plant rooms in high rise buildings.
Powerful discharge
air prevents a short-circuit.
82 Pa (V-III tropical)
80 Pa (V-II tropical)
Previous model V-III tropical , V-II tropical
up to 64 up to 41 up to 9
8HP-54HP / 39models 8HP-42HP / 18models 4HP-6HP / 6models
90m* max. 15m max. TROPICAL series TROPICAL series TROPICAL series
60m max. 40
30
Heating
21°C
40
30
Heating
21°C
40
30
Heating
21°C
(V-II tropical) 20 20 20
10 10 10
*: The limitation on the pipe length 0 0 0
between the farthest IU and the -10 -10 -10 -5°C
nearest IU originated from the first -20 -15°C -20 -15°C -20
separation tube must be 60m or less. -20°C -20°C -20°C
18 19
AIRSTAGE CORE TECHNOLOGY TM
MORE COMFORT
Precision refrigerant flow control High
Hot
Hot ± 0.5°C
Precise and smooth refrigerant flow control is achieved by using Set temp.
a DC Inverter control in conjunction with individual indoor unit
electronic expansion valve control. This allows high precision C ld
Co
comfortable temperature control of ±0.5°C.
Low
Thermal change of the room
*Simulation in heating operation.
Comfortable operation is
Reach the set achieved due to a small variation of
temperature quickly room temperature
Operating 58dB
Cooling capacity (kW)
sound
Keep rated 0
capacity! Quiet priority low noise mode
time
Air
conditioning
load factor Heat load
100%
Capacity Alternated
0 0
automatically
8HP
8 P 1
10HP
P 1
14HP
P 58dB
Operating
sound
0
Reset automatically time
OFF
Time Time
20 21
AIRSTAGE CORE TECHNOLOGY
TM
EASY INSTALLATION
Simple wiring work
Installation of the wiring systems is made easier as the
communication wiring can be installed continuously between
the indoor, outdoor and RB units.
or
Air
Outdoor unit Vacuum pump
1 Signal Amplifier
By adopting a L-Shape front panel that can be removed, the work
space for installation and service has been significantly expanded Expansion of work space
Reduced installation
intervals by front access
Press the push button 2 4 5 6
switch of outdoor unit.
Manual address setting from indoor unit and remote controller is also possible.
22 23
AIRSTAGE CORE TECHNOLOGY
TM
MAINTENANCE • Detail operation status and recent error history can be checked and analyzed by using the Service Tool.
• Last 5 min. operation memory can be also be recorded.
Service Tool
UTY-ASGXZ1
Outdoor unit Software
Transmission line
USB adaptor
(Locally purchased)
Error status can be checked easily via the indoor unit wired controller Error status can be cheked easily by outdoor unit display Transmission line
Unit number
Error and
quantity Indoor unit
Wired Remote Controller annunciation
(Touch panel)
Error status / Error history
Error code
Abnormal indoor
unit address
24 25
The AIRSTAGE 3 Series has a total of 60 models
to meet the environmental and
building size requirements.
AIRSTAGE
TM
AIRSTAGE™ LINE-UP
26 27
AIRSTAGE Series TM
AIRSTAGE™ LINE-UP
Fujitsu General provides multi air conditioning systems for buildings AIRSTAGE Series
matched to the size and application of the property.
BTU/h 36,000 45,000 54,000 72,000 90,000 108,000 126,000 144,000 162,000 180,000 198,000 216,000 234,000 252,000 252,000 270,000 288,000 306,000 306,000 324,000 324,000 342,000 342,000 360,000 378,000 396,000 414,000 432,000 450,000 468,000 486,000
Ton 3.0 3.8 4.5 6.0 7.5 9.0 10.5 12.0 13.5 15.0 16.5 18.0 19.5 21.0 21.0 22.5 24.0 25.5 25.5 27.0 27.0 28.5 28.5 30.0 31.5 33.0 34.5 36.0 37.5 39.0 40.5
Space
saving
AJ½072LN½BH AJ½090LN½BH AJ½108LN½BH AJ½126LN½BH AJ½144LN½BH AJ½162LN½BH AJ½180LN½BH AJ½198LN½BH AJ½216LN½BH AJ½234LN½BH AJ½252LN½BH AJ½252LN½BHA AJ½270LN½BH AJ½288LN½BH AJ½306LN½BH AJ½306LN½BHA AJ½324LN½BH AJ½324LN½BHA AJ½342LN½BH AJ½342LN½BHA AJ½360LN½BH AJ½378LN½BH AJ½396LN½BH AJ½414LN½BH AJ½432LN½BH AJ½450LN½BH AJ½468LN½BH AJ½486LN½BH
TROPICAL series
Heat Pump
High
Efficiency
AJ½144LN½BHH AJ½162LN½BHH AJ½180LN½BHH AJ½216LN½BHH AJ½234LN½BHH AJ½252LN½BHH AJ½270LN½BHH AJ½288LN½BHH AJ½306LN½BHH AJ½324LN½BHH AJ½342LN½BHH AJ½360LN½BHH AJ½378LN½BHH AJ½396LN½BHH AJ½414LN½BHH
Space
saving
AJH072LN½AH½ AJH090LN½AH½ AJH126LN½AH½ AJH144LN½AH½ AJH162LN½AH½ AJH180LN½AH½ AJH198LN½AH½ AJH216LN½AH½ AJH252LN½AH½ AJH270LN½AH½ AJH288LN½AH½ AJH306LN½AH½ AJH324LN½AH½ AJH342LN½AH½ AJH378LN½AH½
TROPICAL series
Heat Pump
High
Efficiency
AJH216LN½AHH½ AJH234LN½AHH½ AJH252LN½AHH½
High
Efficiency
NEW (Single phase)
AJH040LBTAHN AJH045LBTAHN AJH054LBTAHN
TROPICAL series
Heat Pump
High
Efficiency
(3 phase)
AJH040LETAHN AJH045LETAHN AJH054LETAHN
28 29
Features
(COP) 5 4.84
Top class high COP is realized for 4.35 4.34 4.34 4.28
all combinations by our unique 4.03
4.15
3.90 3.90 3.83
4.02 3.95
4 3.81 3.81 3.81
heat exchanger structure, high 3.67 3.67 3.67 3.67 3.67 3.67 3.67 3.67 3.67
TROPICAL series 2
8 10 12 14 16 18 20 22 24* 26 28 30 32 34 36 38 40 42 44 46 48 50 52 54 (HP)
COP 17% UP
2
16 18 20 24* 26 28 30 32 34 36 38 40 42 44 48 (HP)
All Inverter
3 phase DC fan motor
Efficiency is substantially improved by high efficient motor with sophisticated
driver control. In addition, low noise is realized by DC fan motor.
Capacity
DC inverter compressor
Large capacity high efficient DC twin rotary compressor
with 0.1Hz steps compressor speed control
Inverter frequency
System Outline
Subcool heat exchanger
High Heat Exchange efficiency is achieved by using an internal projection
High ambient System configuration example
operation design 52 °C ambient shape double pipe construction.
Separation tube
Header
Keeping high cooling
Advanced energy saving control
20
30 31
Outdoor units lineup
• Combinations other than the followings are not recommended.
TROPICAL series
80 530
(Bolt pitch) 8-12 × 17 (Hole)
180,000 Btu/h (20HP) 198,000 Btu/h (22HP) 216,000 Btu/h (24HP) 234,000 Btu/h (26HP) 252,000 Btu/h (28HP)* 252,000 Btu/h (28HP)
765 930
270,000 Btu/h (30HP) 288,000 Btu/h (32HP) 306,000 Btu/h (34HP)* 306,000 Btu/h (34HP) 324,000 Btu/h (36HP)* 324,000 Btu/h (36HP)
1690
1576
1339
AJ½270LN½BH AJ½288LN½BH AJ½306LN½BH AJ½306LN½BHA AJ½324LN½BH AJ½324LN½BHA
UNIT : AJ½144/126LN½BH UNIT : AJ½144/144LN½BH UNIT : AJ½162/144LN½BH UNIT : AJ½126/090/090LN½BH UNIT : AJ½162/162LN½BH UNIT : AJ½144/090/090LN½BH
342,000 Btu/h (38HP)* 342,000 Btu/h (38HP) 360,000 Btu/h (40HP) 378,000 Btu/h (42HP) 396,000 Btu/h (44HP)* 414,000 Btu/h (46HP)*
432,000 Btu/h (48HP) 450,000 Btu/h (50HP)* 468,000 Btu/h (52HP)* 486,000 Btu/h (54HP)*
1000 (Bolt pitch)
80 840 (Bolt pitch)
8-12×7 (Hole)
765 1240
Energy efficiency combination
144,000 Btu/h (16HP) 162,000 Btu/h (18HP) 180,000 Btu/h (20HP) 216,000 Btu/h (24HP) 234,000 Btu/h (26HP) 252,000 Btu/h (28HP)
1690
AJ½144LN½BHH AJ½162LN½BHH AJ½180LN½BHH AJ½216LN½BHH AJ½234LN½BHH AJ½252LN½BHH
UNIT : AJ½072/072LN½BH UNIT : AJ½090/072LN½BH UNIT : AJ½108/072LN½BH UNIT : AJ½072/072/072LN½BH UNIT : AJ½090/072/072LN½BH UNIT : AJ½108/072/072LN½BH
270,000 Btu/h (30HP) 288,000 Btu/h (32HP) 306,000 Btu/h (34HP) 324,000 Btu/h (36HP) 342,000 Btu/h (38HP) 360,000 Btu/h (40HP)
B A C
AJ½270LN½BHH AJ½288LN½BHH AJ½306LN½BHH AJ½324LN½BHH AJ½342LN½BHH AJ½360LN½BHH A B C Bottom side knockout position
Front side knockout position Left side knockout position
UNIT : AJ½126/072/072LN½BH UNIT : AJ½108/108/072LN½BH UNIT : AJ½126/108/072LN½BH UNIT : AJ½108/108/108LN½BH UNIT : AJ½126/108/108LN½BH UNIT : AJ½126/126/108LN½BH Ø 34.5
73
Power supply cable port Pipe port
43 Ø 43.7 Top view
378,000 Btu/h (42HP) 396,000 Btu/h (44HP) 414,000 Btu/h (46HP) Power supply cable port
Ø 50
Power supply Ø 22.2 Ø 34.5
Transmission cable port Ø 50 Power supply cable port
cable port
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
Model name AJ¾072LN¾BH AJ¾090LN¾BH AJ¾108LN¾BH AJ¾126LN¾BH AJ¾144LN¾BH AJ¾162LN¾BH AJ¾180LN¾BH AJ¾198LN¾BH AJ¾216LN¾BH AJ¾234LN¾BH AJ¾252LN¾BH AJ¾252LN¾BHA AJ¾270LN¾BH AJ¾288LN¾BH AJ¾306LN¾BH AJ¾306LN¾BHA AJ¾324LN¾BH AJ¾324LN¾BHA AJ¾342LN¾BH AJ¾342LN¾BHA AJ¾360LN¾BH AJ¾378LN¾BH AJ¾396LN¾BH AJ¾414LN¾BH AJ¾432LN¾BH AJ¾450LN¾BH AJ¾468LN¾BH AJ¾486LN¾BH
Unit 1 AJ½072LN½BH AJ½090LN½BH AJ½108LN½BH AJ½126LN½BH AJ½144LN½BH AJ½162LN½BH AJ½090LN½BH AJ½126LN½BH AJ½126LN½BH AJ½144LN½BH AJ½162LN½BH AJ½126LN½BH AJ½144LN½BH AJ½144LN½BH AJ½162LN½BH AJ½126LN½BH AJ½162LN½BH AJ½144LN½BH AJ½162LN½BH AJ½126LN½BH AJ½144LN½BH AJ½144LN½BH AJ½162LN½BH AJ½162LN½BH AJ½144LN½BH AJ½162LN½BH AJ½162LN½BH AJ½162LN½BH
Unit 2 AJ½090LN½BH AJ½072LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½126LN½BH AJ½126LN½BH AJ½144LN½BH AJ½144LN½BH AJ½090LN½BH AJ½162LN½BH AJ½090LN½BH AJ½090LN½BH AJ½126LN½BH AJ½126LN½BH AJ½144LN½BH AJ½144LN½BH AJ½162LN½BH AJ½144LN½BH AJ½144LN½BH AJ½162LN½BH AJ½162LN½BH
Unit 3 AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½090LN½BH AJ½144LN½BH AJ½144LN½BH AJ½144LN½BH AJ½162LN½BH
Maximum Connectable Indoor Unit 13 16 19 23 26 29 33 36 43 43 46 47 50 53 55 55 55 55 55 55 55 55 55 55 55 55 55 55
Indoor unit connectable capacity Cooling kW 11.2-29.1 14-36.4 16.8-43.5 20-52 22.5-58.5 25-65 28-72.8 31.2-81.1 36.5-94.9 36.5-94.9 39-101.4 40-104 42.5-110.5 45-117 47.5-123.5 48-124.8 50-130 50.5-131.3 53-137.8 54-140.4 56.5-146.9 59-153.4 61.5-159.9 64-166.4 67.5-175.5 70-182 72.5-188.5 75-195
EER W/W 3.00 2.74 3.05 2.99 2.97 2.85 2.74 2.99 2.87 2.87 2.80 2.99 2.98 2.97 2.91 2.83 2.85 2.83 2.78 2.91 2.91 2.91 2.86 2.82 2.97 2.93 2.89 2.85
Cooling
Btu/h/W 10.23 9.35 10.40 10.20 10.14 9.72 9.35 10.21 9.79 9.79 9.56 10.20 10.17 10.14 9.93 9.66 9.72 9.66 9.50 9.95 9.93 9.92 9.77 9.62 10.14 10.00 9.86 9.72
Power factor % 90 92 92 92 92 93 - - - - - - - - - - - - - - - - - - - - - -
Airflow rate High m3/h 11100 11100 13000 13000 13700 13700 11100×2 13000+11100 13700+11100 13700+11100 13700+11100 13000×2 13700+13000 13700×2 13700×2 13000+11100×2 13700×2 13700+11100×2 13700+11100×2 13000×2+11100 13700+13000+11100 13700×2+11100 13700×2+11100 13700×2+11100 13700×3 13700×3 13700×3 13700×3
Sound pressure level / Cooling dB 56 58 57 60 62 63 61 61 63 63 64 63 64 65 66 64 66 65 65 64 65 66 66 67 67 67 67 68
Power level Heating (A) 58 59 60 62 64 64 62 63 65 65 65 65 66 67 67 65 67 66 66 66 67 68 68 68 69 69 69 69
External static pressure (Max) Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5 7.5 11 11 11 11 7.5×2 11.0+7.5 11.0+7.5 11.0+7.5 11.0+7.5 11.0×2 11.0×2 11.0×2 11.0×2 11.0+7.5×2 11.0×2 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1690 1690 1690 1690 1690 1690 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×2 1690×3 1690×2 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3
Dimensions Width mm 930 930 1240 1240 1240 1240 930×2 1240+930 1240+930 1240+930 1240+930 1240×2 1240×2 1240×2 1240×2 1240+930×2 1240×2 1240+930×2 1240+930×2 1240×2+930 1240×2+930 1240×2+930 1240×2+930 1240×2+930 1240×3 1240×3 1240×3 1240×3
Depth 765 765 765 765 765 765 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×2 765×3 765×2 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3
Weight kg 255 255 279 279 279 279 255×2 279+255 279+255 279+255 279+255 279×2 279×2 279×2 279×2 279+255×2 279×2 279+255×2 279+255×2 279×2+255 279×2+255 279×2+255 279×2+255 279×2+255 279×3 279×3 279×3 279×3
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A
Refrigerant
Charge kg 11.7 11.7 11.8 11.8 11.8 11.8 11.7×2 11.8+11.7 11.8+11.7 11.8+11.7 11.8+11.7 11.8×2 11.8×2 11.8×2 11.8×2 11.8+11.7×2 11.8×2 11.8+11.7×2 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×2+11.7 11.8×3 11.8×3 11.8×3 11.8×3
Liquid 12.70 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05
Connection pipe diameter mm
Gas 22.22 22.22 28.58 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -15 to 52 -15 to 52 -15 to 52 -15 to 52 -15 to 52 -15 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52
Operation range ºCDB
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Model name AJ¾144LN¾BHH AJ¾162LN¾BHH AJ¾180LN¾BHH AJ¾216LN¾BHH AJ¾234LN¾BHH AJ¾252LN¾BHH AJ¾270LN¾BHH AJ¾288LN¾BHH AJ¾306LN¾BHH AJ¾324LN¾BHH AJ¾342LN¾BHH AJ¾360LN¾BHH AJ¾378LN¾BHH AJ¾396LN¾BHH AJ¾414LN¾BHH
Unit 1 AJ½072LN½BH AJ½090LN½BH AJ½108LN½BH AJ½072LN½BH AJ½090LN½BH AJ½108LN½BH AJ½126LN½BH AJ½108LN½BH AJ½126LN½BH AJ½108LN½BH AJ½126LN½BH AJ½126LN½BH AJ½126LN½BH AJ½144LN½BH AJ½144LN½BH
Unit 2 AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½108LN½BH AJ½108LN½BH AJ½108LN½BH AJ½108LN½BH AJ½126LN½BH AJ½126LN½BH AJ½126LN½BH AJ½144LN½BH
Unit 3 AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½072LN½BH AJ½108LN½BH AJ½108LN½BH AJ½108LN½BH AJ½126LN½BH AJ½126LN½BH AJ½126LN½BH
Maximum Connectable Indoor Unit 26 29 33 39 43 46 50 52 55 55 55 55 55 55 55
Indoor unit connectable capacity Cooling kW 22.4-58.2 25.2-65.5 28-72.6 33.6-87.3 36.4-94.6 39.2-101.7 42.4-110.2 44.7-116.2 48-124.6 50.3-130.6 53.5-139.1 56.8-147.5 60-156 62.5-162.5 65-169
EER W/W 3.00 2.85 3.03 3.00 2.89 3.02 3.00 3.04 3.01 3.05 3.03 3.01 2.99 2.98 2.98
Cooling
Btu/h/W 10.23 9.72 10.33 10.23 9.87 10.30 10.22 10.36 10.28 10.40 10.33 10.26 10.20 10.18 10.16
Power factor % - - - - - - - - - - - - - - -
Airflow rate High m3/h 11100×2 11100×2 13000+11100 11100×3 11100×3 13000+11100×2 13000+11100×2 13000×2+11100 13000×2+11100 13000×3 13000×3 13000×3 13000×3 13700+13000×2 13700×2+13000
Sound pressure level / Cooling dB 59 60 60 61 62 61 63 61 63 64 64 64 65 66 66
Power level Heating (A) 61 62 62 63 63 64 65 64 65 66 66 66 67 68 68
External static pressure (Max) Pa 82 82 82 82 82 82 82 82 82 82 82 82 82 82 82
Compressor motor output kW 7.5×2 7.5×2 11.0+7.5 7.5×3 7.5×3 11.0+7.5×2 11.0+7.5×2 11.0×2+7.5 11.0×2+7.5 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3 11.0×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Note: Specifications are based on the following conditions.
Height 1690×2 1690×2 1690×2 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3 1690×3
Dimensions Width mm 1240×2 1240×2 1240+930 930×3 930×3 1240+930×2 1240+930×2 1240×2+930 1240×2+930 1240×3 1240×3 1240×3 1240×3 1240×3 1240×3 Cooling(T1): Indoor temperature of 27°CDB / 19°CWB, and
Depth 765×2 765×2 765×2 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 765×3 outdoor temperature of 35°CDB / 24°CWB
Weight kg 279×2 279×2 279+255 255×3 255×3 279+255×2 279+255×2 279×2+255 279×2+255 279×3 279×3 279×3 279×3 279×3 279×3 Cooling(T3): Indoor temperature of 29°CDB / 19°CWB, and
Type R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A R410A outdoor temperature of 46°CDB / 24°CWB
Refrigerant
Charge kg 11.7×2 11.7×2 11.8+11.7 11.7×3 11.7×3 11.8+11.7×2 11.8+11.7×2 11.8×2+11.7 11.8×2+11.7 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3 11.8×3
Liquid 12.70 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 19.05 Heating: Indoor temperature of 20°CDB / (15°CWB), and
Connection pipe diameter mm outdoor temperature of 7°CDB / 6°CWB.
Gas 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27 41.27 41.27 41.27
Cooling -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 -5 to 46 Pipe length: 7.5m. Height difference between outdoor and
Operation range ºCDB
Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 indoor unit: 0m.
AJ½___LN½: AJG___LNL, AJH___LNT
34 35
Features
TROPICAL series 3
2
Fujitsu General tropical VRF is designed for tropical weather. 8 10 14 16 18 20 22 24* 28 30 32 34 36 38 42 (HP)
(COP) 5
For 24 HP Combination
4.37
4.23 4.12 Space saving Energy efficiency
4
COP 15% UP
2
24* 26 28 (HP)
DC fan motor
Power consumption has been reduced by 25% compared
to previous models by using a compact and high
performance DC fan motor.
System Outline
High ambient System configuration example
operation design 52 °C ambient Sine-wave DC inverter control
High efficiency operation is realized by using a sine
• This system is used for medium-sized and large buildings.
Possible to operate cooling up Cooling operation range wave DC inverter control.
Connecting each outdoor unit makes it possible to create a
to 52ºC outdoor temperature high-capacity system.
50 40 30
52 • Connection of multiple indoor units using separation tubes
Outdoor temperature (°C) DC inverter compressor
and headers.
Significantly greater efficiency is realized by use of a
large capacity DC twin rotary compressor with
Powerful cooling 40 35ºC ambient temp. Outdoor unit substantially increased refrigerant intake and
capacity design 46ºC ambient temp.
compression efficiency.
Cooling capacity (kW)
Separation tube
Header
Keeping high cooling 20
36 37
Outdoor units lineup
• Combinations other than the followings are not recommended.
TROPICAL series
80 530
(Bolt pitch) 8-12 × 17 (Hole)
180,000 Btu/h (20HP) 198,000 Btu/h (22HP) 216,000 Btu/h (24HP) 252,000 Btu/h (28HP) 270,000 Btu/h (30HP)
765 930
288,000 Btu/h (32HP) 306,000 Btu/h (34HP) 324,000 Btu/h (36HP) 342,000 Btu/h (38HP) 378,000 Btu/h (42HP)
1690
1576
1339
AJH288LN½AH½ AJH306LN½AH½ AJH324LN½AH½ AJH342LN½AH½ AJH378LN½AH½
UNIT : AJH126/090/072LN½AH½ UNIT : AJH126/090/090LN½AH½ UNIT : AJH126/126/072LN½AH½ UNIT : AJH126/126/090LN½AH½ UNIT : AJH126/126/126LN½AH½
765 1240
1690
B A C
80
Power supply
cable port Ø 43.7
Ø 22.2 Power supply cable port
Transmission cable port
82
Ø 22.2
95
Ø 22.2
75
125
100
199
AJH___LN½AH½ : AJH___LNTAH, AJH___LNLAHU
AJH___LNTAHH, AJH___LNLAHHU
38 39
Outdoor units specifications
TROPICAL series
Model name AJH072LN¾AH¾ AJH090LN¾AH¾ AJH126LN¾AH¾ AJH144LN¾AH¾ AJH162LN¾AH¾ AJH180LN¾AH¾ AJH198LN¾AH¾ AJH216LN¾AH¾ AJH252LN¾AH¾ AJH270LN¾AH¾ AJH288LN¾AH¾ AJH306LN¾AH¾ AJH324LN¾AH¾ AJH342LN¾AH¾ AJH378LN¾AH¾
Unit 1 AJH072LN½AH½ AJH090LN½AH½ AJH126LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH090LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½
Unit 2 AJH072LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH126LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH090LN½AH½ AJH126LN½AH½ AJH126LN½AH½ AJH126LN½AH½
Unit 3 AJH072LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH072LN½AH½ AJH090LN½AH½ AJH126LN½AH½
Maximum Connectable Indoor Unit*1 13 13 18 26 26 26 28 31 36 39 41 41 41 41 41
Indoor unit connectable capacity kW 11.2-29.1 14.0-36.4 20.0-52.0 22.4-58.2 25.2-65.5 28.0-72.8 31.2-71.1 34.0-88.4 40.0-104.0 42.4-110.2 45.2-117.5 48.0-124.8 51.2-133.1 54.0-140.4 60.0-156.0
Power source 3-phase, ~400V, 50Hz 3-phase, ~400V, 50Hz
Cooling(T1) 22.4 28.0 40.0 44.8 50.4 56.0 62.4 68.0 80.0 84.8 90.4 96.0 102.4 108.0 120.0
Capacity Cooling(T3) kW 22.4 24.3 30.7 44.8 46.7 48.6 53.1 55.0 61.4 75.5 77.4 79.3 83.8 85.7 92.1
Heating(T1) 25.0 31.5 45.0 50.0 56.5 63.0 70.0 76.5 90.0 95.0 101.5 108.0 115.0 121.5 135.0
Cooling(T1) 5.51 7.73 11.53 11.02 13.24 15.46 17.04 19.26 23.06 22.55 24.77 26.99 28.57 30.79 34.59
Input power kW
Heating 5.72 7.83 11.45 11.44 13.55 15.66 17.17 19.28 22.90 22.89 25.00 27.11 28.62 30.73 34.35
EER Cooling(T1) W/W 4.07 3.62 3.47 4.07 3.81 3.62 3.66 3.53 3.47 3.76 3.65 3.56 3.58 3.51 3.46
COP Heating W/W 4.37 4.02 3.93 4.37 4.17 4.02 4.08 3.97 3.93 4.15 4.06 3.98 4.02 3.95 3.93
Airflow rate m3/h 11,100 11,100 13,000 11,100×2 11,100×2 11,100×2 13,000+11,100 13,000+11,100 13,000×2 13,000+11,100×2 13,000+11,100×2 13,000+11,100×2 13,000×2+11,100 13,000×2+11,100 13,000×3
Cooling 56 58 60 59 60 61 61 62 63 63 63 64 64 64 65
Sound pressure level*2 dB(A)
Heating 58 59 61 59 62 62 62 63 64 63 64 65 65 65 66
Maximum external static pressure Pa 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80
Compresor motor output kW 3.9 3.9 3.9+4.5 3.9×2 3.9×2 3.9×2 3.9×2+4.5 3.9×2+4.5 3.9×2+4.5×2 3.9×3+4.5 3.9×3+4.5 3.9×3+4.5 3.9×3+4.5×2 3.9×3+4.5×2 3.9×3+4.5×3
Heat exchanger fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
Height 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690 1,690
Dimensions Width mm 930 930 1,240 930×2 930×2 930×2 1,240+930 1,240+930 1,240×2 1,240+930×2 1,240+930×2 1,240+930×2 1,240×2+930 1,240×2+930 1,240×3
Depth 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765
Weight kg 220 220 303 220+220 220+220 220+220 303+220 303+220 303+303 303+220+220 303+220+220 303+220+220 303+303+220 303+303+220 303+303+303
Refrigerant charge kg 11.2 11.2 11.8 11.2×2 11.2×2 11.2×2 11.8+11.2 11.8+11.2 11.8×2 11.8+11.2×2 11.8+11.2×2 11.8+11.2×2 11.8×2+11.2 11.8×2+11.2 11.8×3
Connection pipe Liquid 12.70 12.70 12.70 12.70 15.88 15.88 15.88 15.88 15.88 19.05 19.05 19.05 19.05 19.05 19.05
mm
diameter Gas 22.22 22.22 28.58 28.58 28.58 28.58 34.92 34.92 34.92 34.92 34.92 34.92 41.27 41.27 41.27
Operation Cooling -15 to 52 *1 -15 to 52 *1 -15 to 52 *1 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52
ÝCDB
temperature range Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
Connection pipe Liquid 15.88 15.88 15.88 *1 Minimum connectable indoor unit number is 2.
mm However ARXC72 and ARXC90 can be used signal connection.
diameter Gas 34.92 34.92 34.92
*2 The noise value is the value when measured in an anechoic room.
Operation Cooling -5 to 52 -5 to 52 -5 to 52
ÝCDB When measured in the actual installed state, surrounding noise and reflections are received and
temperature range Heating -20 to 21 -20 to 21 -20 to 21 the measured value is usually larger than the indicated value.
All Inverter
Large propeller fan
High performance and low noise realized
ealized
n of
by large propeller and optimization
angle.
effect
connected.
Liquid pipe
Indoor unit INVERTER Compressor
Efficiency in all load regions is good.
Gas pipe
Especially good performance from low to
medium at normal operation.
42 43
Features
TROPICAL series
Actual piping length Height difference between Power source Single-phase, ~230V, 50Hz 3-phase, ~400V, 50Hz
outdoor and indoor units Cooling(T1/T3) 12.1/10.3 14.0/11.1 15.5/11.5 12.1/10.3 14.0/11.1 15.5/11.5
kW
120m max. 50m max. Capacity
Heating
Cooling(T1/T3)
Btu/h
13.6
41,000/35,000
16.0
47,500/37,800
18.0
52,500/39,000
13.6
41,000/35,000
16.0
47,500/37,800
18.0
52,500/39,000
Heating 46,000 54,500 61,000 46,000 54,500 61,000
For the outdoor unit installed
below the indoor units: Cooling(T1/T3) 2.90/3.47 3.57/3.77 4.18/3.92 2.79/3.30 3.46/3.57 3.99/3.71
Input power kW
40 m max. Heating 2.80 3.55 4.26 2.71 3.40 4.08
Cooling(T1/T3) 12.7/15.2 15.7/16.6 18.4/17.2 5.2/6.2 6.6/6.6 7.7/6.9
Current A
Heating 12.3 15.6 18.7 5.0 6.5 7.8
W/W 4.17/2.97 3.92/2.95 3.71/2.94 4.33/3.13 4.05/3.11 3.88/3.10
EER Cooling(T1/T3)
Btu/h/W 14.15/10.10 13.30/10.05 12.60/9.95 14.70/10.60 13.75/10.60 13.15/10.50
W/W 4.86 4.51 4.23 5.01 4.70 4.41
COP Heating
Btu/h/W 16.45 15.35 14.30 17.00 16.00 14.95
Airflow rate High m3/h(l/s) 6,200(1,722) 6,400(1,778) 6,900(1,916) 6,200(1,722) 6,400(1,778) 6,900(1,916)
Cooling 50 51 53 50 51 53
Sound pressure level dB(A)
Heating 52 53 55 52 53 55
Height 1,334 1,334 1,334 1,334 1,334 1,334
Net Dimensions Width mm 970 970 970 970 970 970
Depth 370 370 370 370 370 370
Net Weight kg 120 120 120 120 120 120
Refrigerant Type R410A R410A R410A R410A R410A R410A
Connection Liquid 9.52 9.52 9.52 9.52 9.52 9.52
mm
pipe diameter Gas 15.88 15.88 19.05 15.88 15.88 19.05
Operation Cooling -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52 -5 to 52
ÝCDB
range Heating -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21 -20 to 21
43(Liquid)
51(Gas)
Previous model
(410)
(Heating operation)
370
J-III series
A comfortable room condition is maintained during oil recovery
mode because the product continues to operate without
40
stopping the cooling or heating operation.
32
36
970 32 370 12
ON ON
OFF
Time Time
Terminal blocks (Power)
1334
1000
907
Easier Installation
3-Way valve (Liquid)
111
70
le port)
(Liquid valve)
(Gas valve)
ab
Ø28 (C
connection and address setting are correct by a quick check run function.
297
279
120
21
25
95
155
142
131
87
Ø28 (Cable port) Ø28 (Cable port)
50
50
50
Ø28 (Cable port) 89 Pipe port 21 55 Ø28 (Cable port) 21 65 Ø28 (Cable port)
Pipe port Pipe port
A
Detail A
65 15
227
305
14
341
50
• Duplicately set address number of indoor unit can be
50
displayed 438 Pipe & cable port
622
44 45
13 Type and 99 models available to meet
the requirements of any building design.
The AIRSTAGE indoor units were developed to be highly efficient, compact, low noise
and to have user friendly operation. With a variety of indoor units and capacities
available, Fujitsu General has an indoor unit to match any requirement which is easy
AIRSTAGE
TM
INDOOR UNITS LINE-UP
INDOOR UNITS
4-way Flow Compact Cassette
Mini Duct
Floor / Ceiling
Ceiling
46 47
AIRSTAGE Indoor units
TM
(Large type)
AUGA18GALH AUGA24GALH AUGA30GALH AUGA34GALH AUGA36GALH AUGA45GALH AUGA54GALH
AUGA30GATH AUGA36GATH AUGA45GATH AUGA54GATH
Mini Duct
(With drain pump)
ARGK07GCLH ARGK09GCLH ARGK12GCLH ARGK14GCLH ARGK18GCLH ARGK24GCLH
Mini Duct
(Without drain pump)
ARGK07GALH ARGK09GALH ARGK12GALH ARGK14GALH ARGK18GALH ARGK24GALH
Slim Duct
(With drain pump)
ARGD07GATH ARGD09GATH ARGD12GATH ARGD14GATH ARGD18GATH ARGD24GATH
Floor
(Same as Ceiling models)
ABGA12GATH ABGA14GATH ABGA18GATH ABGA24GATH
Floor
Ceiling Ceiling
Wall Mounted
ASGA07GACH ASGA09GACH ASGA12GACH ASGA14GACH ASGA18GACH ASGA24GACH ASGA30GACH
ASGA07GATH ASGA09GATH ASGA12GATH ASGA14GATH ASGA18GATH ASGA24GATH ASGA30GATH
Wall Mounted
With this model,
Wall Mounted
connection of
(EEV external)
EV kit is necessary.
ASGE07GACH ASGE09GACH ASGE12GACH ASGE14GACH
*1:ARGC60/72/90/96 cannot be connected to J-III tropical series. *2:Large Airflow Duct can be connected to V-III tropical series only.
48 49
AIRSTAGE Indoor units TM
570mm
570m
High lift drain pump
Ceiling panel
compact cassette category Max.
Models Models
(Easy installation by taking off 700mm
ceiling panel of 600 x 600 size)
AUGB07GALH AUGB07GATH
AUGB09GALH AUGB09GATH
AUGB12GALH AUGB12GATH
AUGB14GALH AUGB14GATH
AUGB18GALH AUGB18GATH
AUGB24GALH AUGB24GATH
Optional parts
Air Outlet Shutter Plate : UTR-YDZB
Insulation Kit for High Humidity : UTZ-KXGC
Specifications
AUGB07GALH AUGB09GALH AUGB12GALH AUGB14GALH AUGB18GALH AUGB24GALH
Model name
Feature AUGB07GATH AUGB09GATH AUGB12GATH AUGB14GATH AUGB18GATH AUGB24GATH
Power source Single-phase, 230V, 50Hz
Capacity Cooling 2.2 2.8 3.6 4.5 5.6 7.1
kW
2-stage turbo fan Quiet quality Heating 2.8 3.2 4.1 5.0 6.3 8.0
Input power W 25 25 29 35 36 84
High efficiency design by 2 stage structure Optimization of wing form (laminar wing type) and Airflow rate High 540 (150) 550 (153) 600 (167) 680 (189) 710 (197) 1,030 (286)
wing number (7 blades each) Med m3/h
450 (125) 450 (125) 530 (147) 590 (164) 580 (161) 830 (231)
An evenly spread air distribution across the heat (l/s)
Designed by CFD-analysis (fluid) simulations Low 350 (97) 350 (97) 390 (108) 390 (108) 400 (111) 450 (125)
exchanger is possible due to the new 2 stage turbo fan Sound pressure High 34 35 37 38 41 50
which produces two separate airflow streams. level
Adoption of laminar wing Med dB(A) 30 30 34 34 35 44
1-stage 2-stage turbo fan Laminar wing Low 25 25 27 27 27 30
Wind velocity
Fast Quiet Airflow runs through smoothly Dimensions (H x W x D) mm 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570 245 × 570 × 570
Heat exchange
efficiency along the laminar wing Weight kg(lbs) 15 (33) 15 (33) 15 (33) 15 (33) 17 (37) 17 (37)
+
2-stage
= 20%UP Connection Liquid (Flare) 6.35 6.35 6.35 6.35 9.52 9.52
Slow
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.U.) 25 / 32
Previous turbo fan
Quiet Cassette Model name UTG-UFGC-W
In the case of a previous fan, the air outlet range was narrow as the Grille Dimensions (HxWxD) mm 50 × 700 × 700
airflow moved to the motor side which meant the velocity of air Spin direction
passing through the heat exchanger was uneven.
No airflow separation Weight kg(lbs) 2.6 (6)
Airflow direction
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
Heating : Indoor temperature of 20ÝCDB / (15ÝCWB), and outdoor temperature of 7ÝCDB / 6ÝCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
700
18 2.7 3.0
2
Grille cover 24 2.7 3.0
75
1 Maintenance of fan motor and fan
Maintenance of the fan motor and fan can be done easily after taking
135 250
off the panel as the bell mouth of the fan can be removed easily. 700 Top view
116
30
49
102
262
2 Air filter : standard equipment
108
222
146
30
40
245
Side view
124
58
Ceiling
During installation, maintenance and operation, the drain pump Control box
and kit can be checked easily. Liquid pipe Gas pipe Side view
50 51
AIRSTAGE Indoor units
TM
Optional parts
IR Receiver Unit : UTY-LRHGB1
Air Outlet Shutter Plate : UTR-YDZK
Panel Spacer : UTG-BKXA-W
Insulation Kit for High Humidity : UTZ-KXRA
Wide Panel : UTG-AKXA-W
Specifications
AUGD18GALH AUGD24GALH
Model name
Feature AUGD18GATH AUGD24GATH
Power source Single-phase, 230V, 50Hz
Capacity Cooling 5.6 7.1
kW
High efficiency turbo fan with 3-dimensional blade Heating 6.3 8.0
Input power W 39 46
High efficiency airflow distribution has been achieved by the introduction of a 3 Airflow rate High 1,150 (319) 1,280 (356)
Previous turbo fan
dimensional blade which increases the air passing over the heat exchanger. Med m3/h
940 (261) 1,040 (289)
Air passing through the heat exchanger was uneven and the air would only flow (l/s)
close to the ceiling. Low 870 (242) 870 (242)
500mm 450mm Sound pressure High 36 38
level Med dB(A) 30 33
Previous blade Low
3-dimensional blade 29 29
Dimensions (H x W x D) mm 246 × 840 × 840 246 × 840 × 840
Weight kg(lbs) 22 (48) 22 (48)
Heat exchanger
Heat exchanger < Motor side > Connection Liquid (Flare) 9.52 9.52
Separation
< Motor side > phenomenon of pipe diameter Gas (Flare) mm 15.88 15.88
Wind velocity
Fast Quiet airflow Drain hose diameter (I.D./O.U.) 25 / 32
causes noise
No airflow separation Cassette Model name UTG-UGGA-W
Uneven airflow Grille Dimensions (HxWxD) mm 50 × 950 × 950
Slow
Weight kg(lbs) 5.5 (12)
: Spin direction : Airflow direction : Turbulent flow noise
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
Heating : Indoor temperature of 20ÝCDB / (15ÝCWB), and outdoor temperature of 7ÝCDB / 6ÝCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Improvement of the airflow distribution
The louvre design distributes air Front part Ceiling
leaving a space between the
chassis and the ceiling allowing Dimensions (Unit : mm)
far and wide air flow distribution.
IR receiver 796
(Option) 950
Hanging bolt position
Rear part
Ceiling opening
860 to 910
950
699
420
Adjustment of hanger position is High ceiling mode
607
possible after installation This cassette can be installed up to a height of 3.5m.
Drain hose
The maximum height from floor to ceiling (m) 358
Model code (Control) Box
Detachable Standard mode High ceiling mode
358 278 60
Grille corner 18 3.0 3.5
40
24 3.0 3.5
246
200
Adjustment can be done
just taking off the corner part
142
142
10
140
44
Ceiling Liquid pipe Gas pipe
Wire hole
52 53
AIRSTAGE Indoor units
TM
Specifications
AUGA18GALH AUGA24GALH AUGA30GALH AUGA34GALH AUGA36GALH AUGA45GALH AUGA54GALH
Model name
Feature AUGA30GATH AUGA36GATH AUGA45GATH AUGA54GATH
Power source Single-phase, 230V, 50Hz
Capacity Cooling 5.6 7.1 9.0 10.0 11.2 12.5 14.0
kW
High efficiency turbo fan with 3-dimensional blade Heating 6.3 8.0 10.0 11.2 12.5 14.0 16.0
Input power W 51 51 59 77 80 99 119
High efficiency airflow distribution has been achieved by the introduction of a 3 Airflow rate High 1,420 (394) 1,420 (394) 1,600 (444) 1,750 (486) 1,800 (500) 1,900 (528) 2,000 (556)
Previous turbo fan
dimensional blade which increases the air passing over the heat exchanger. Med m3/h
1,230 (342) 1,230 (342) 1,300 (361) 1,300 (361) 1,300 (361) 1,370 (381) 1,370 (381)
Air passing through the heat exchanger was uneven and the air would only flow (l/s)
close to the ceiling. Low 1,100/1,000*1(306/278) 1,100/1,000*1(306/278) 1,100 (306) 1,100 (306) 1,100 (306) 1,100 (306) 1,100 (306)
500mm 450mm Sound pressure High 40 40 40 43 44 46 47
level Med dB(A) 36 36 38 38 38 39 39
Previous blade Low
3-dimensional blade 33/31*1 33/31*1 33 33 33 33 33
Dimensions (H x W x D) mm 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840 288 × 840 × 840
Weight kg(lbs) 27 (59) 27 (59) 27 (59) 27 (59) 27 (59) 27 (59) 27 (59)
Heat exchanger
Heat exchanger < Motor side > Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52 9.52
Separation
< Motor side > phenomenon of pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05 19.05 19.05
Wind velocity
Fast Quiet airflow Drain hose diameter (I.D./O.U.) 25 / 32
causes noise
No airflow separation Cassette Model name UTG-UGGA-W
Uneven airflow Grille Dimensions (HxWxD) mm 50 × 950 × 950
Slow
Weight kg(lbs) 5.5 (12)
: Spin direction : Airflow direction : Turbulent flow noise
Note : Specifications are based on the following conditions.
Cooling : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
Heating : Indoor temperature of 20ÝCDB / (15ÝCWB), and outdoor temperature of 7ÝCDB / 6ÝCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Improvement of the airflow distribution *1: This value is “cooling operation / heating operation”.
Ceiling opening
860 to 910
950
699
420
Adjustment of hanger position is High ceiling mode
607
possible after installation This cassette can be installed up to a height of 4.2m (36/45/54).
Drain hose
The maximum height from floor to ceiling (m) 358
Model code (Control) Box
Detachable Standard mode High ceiling mode
358 278 60
Grille corner 18 3.0 3.5
40
24 3.0 3.5
30 3.2 3.6
288
200
Adjustment can be done 34 3.2 3.6
just taking off the corner part 36 3.2 4.2
142
142
10
140
45 3.2 4.2
44
Ceiling Liquid pipe Gas pipe
54 3.2 4.2 Wire hole
54 55
AIRSTAGE Indoor units
TM
ARGK24 ARGK24
Specifications
ARGK07GCLH ARGK09GCLH ARGK12GCLH ARGK14GCLH ARGK18GCLH ARGK24GCLH
Model name
Feature ARGK07GALH ARGK09GALH ARGK12GALH ARGK14GALH ARGK18GALH ARGK24GALH
Power source Single-phase, 230V, 50Hz
Capacity Cooling 2.2 2.8 3.6 4.5 5.6 7.1
kW
Heating 2.8 3.2 4.0 5.0 6.3 8.0
Optimum design in harmony with interior decoration Input power GCLH / GALH W 28 / 21 28 / 21 35 / 28 66 / 59 73 / 66 80 / 73
High 460 (128) 460 (128) 550 (153) 760 (211) 930 (258) 1,160 (322)
Thin and short-depth body makes the clipped ceiling design simple. Me-Hi 440 (122) 440 (122) 520 (144) 660 (183) 840 (233) 1,060 (294)
Med m3/h 420 (117) 420 (117) 480 (133) 560 (156) 740 (206) 960 (267)
Airflow rate
Me-Lo (l/s) 400 (111) 400 (111) 450 (125) 490 (136) 640 (178) 860 (239)
Low 370 (103) 370 (103) 410 (114) 410 (114) 540 (150) 750 (208)
Quiet 340 (94) 340 (94) 340 (94) 340 (94) 470 (131) 610 (169)
Static pressure range 0 to 30 0 to 30 0 to 30 0 to 50 0 to 50 0 to 50
Pa
Standard static pressure 10 10 10 15 15 15
223mm
High 26 26 29 34 33 32
198mm
Me-Hi 25 25 27 31 30 30
Sound pressure Med 24 24 26 28 28 28
dB(A)
level Me-Lo 23 23 25 26 26 27
m Low 22 22 24 24 24 25
m 0 m Quiet
m 21 21 22 22 22 22
50 60 Dimensions (H x W x D) kg(lbs)
4 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 700 × 450 198 × 900 × 450 198 × 1,100 × 450
Weight GCLH / GALH mm 15.5 (34) / 15 (33) 15.5 (34) / 15 (33) 16 (35) / 15.5 (34) 16 (35) / 15.5 (34) 19 (42) / 18.5 (41) 22.5 (50) / 22 (49)
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.U.) 25 / 32
Advanced performance by new shaped Easy drain design even at narrow ceiling Dimensions (Unit : mm)
heat exchanger and airflow Models with drain pump: Drainage to the distant drain port is possible.
*Models (With drain pump)
775 52
*Models (Without drain pump)
775 52
174
153
Air blower is improved so that velocity distribution is optimum in
174
153
72
72
accordance with the heat exchanger shape. Wide range and uniform Rear view Rear view
Models with drain pump
airflow can be received due to heat exchanger.
For models with drain pump, Drain port
Drain port
Drain port
295
30
30
drain design is easy even at narrow
295
450
450
Fan casing ceiling.
193
150
182
193
182
182
10
150
10
View A
30
A A
169
B 49 B 49
C 56 78 Side view C 56 78
49 66 49
Top view Side view Top view Side view
85 92 85 92
169
57
57
43 169
198
168
150
198
168
150
78
78
33 33
D D
Models without drain pump (Drain hose)
E
(Drain hose)
E
F F
Front view
For models without drain pump, Front view
56 57
AIRSTAGE Indoor units
TM
Slim Duct / Slim Concealed Floor Auto Louver Grille Kit (Option)
Simple flat Auto Louver will provide comfort airflow and harmonize
Optional parts
Remote Sensor Unit : UTY-XSZX
with luxury interior. IR Receiver Unit : UTB-YWC
Auto Louver Grille Kit : UTD-GXTA-W (for ARGD07/09/12/14GATH)
Models Slim Duct Auto Louver Grille
UTD-GXTB-W (for ARGD18GATH)
ARGD07GATH UTD-GXTC-W (for ARGD24GATH)
ARGD09GATH
ARGD12GATH ARGD07 ARGD09 ARGD12 ARGD14 ARGD18
ARGD14GATH
ARGD18GATH
ARGD24GATH
Specifications
Model name ARGD07GATH ARGD09GATH ARGD12GATH ARGD14GATH ARGD18GATH ARGD24GATH
Feature Power source Single-phase, 230V, 50Hz
Capacity Cooling 2.2 2.8 3.6 4.5 5.6 7.1
kW
Heating 2.8 3.2 4.0 5.0 6.3 8.0
Slim design Selectable with a wide range of Input power W 44 50 54 92 83 122
Airflow rate High 550 (153) 600 (167) 600 (167) 800 (222) 940 (261) 1,330 (369)
With a slim indoor design, this indoor can static pressure Med
m3/h
(l/s) 490 (136) 550 (153) 510 (142) 710 (197) 840 (233) 1,240 (344)
be installed in narrow ceiling spaces. Low 440 (122) 480 (133) 450 (125) 610 (169) 750 (208) 1,100 (306)
Drain port By using DC fan motor, it is possible to Static pressure range 0 to 90 0 to 90 0 to 90 0 to 90 0 to 90 0 to 50
Static pressure range Pa
change of static pressure range 0 to 90Pa. Standard static pressure 25 25 25 25 25 25
The change of static pressure range is 0 to 90 Pa Sound pressure High 28 29 30 34 34 35
Height
possible by remote controller. *24 model is 0 to 50Pa level Med dB(A) 25 26 27 32 32 32
198mm Low 22 24 24 28 28 29
Drain pump Dimensions (H x W x D) mm 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 700 × 620 198 × 900 × 620 198 × 1,100 × 620
Drain pump built-in Weight kg(lbs) 17 (37) 17 (37) 18 (40) 18 (40) 22 (48) 26 (57)
Connection Liquid (Flare) 6.35 6.35 6.35 6.35 9.52 9.52
High lift drain pump pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.U.) 25 / 32
51 G
174
152
71
30
ARGD07 / 09 / 12 / 14 / 18 ARGD24
Filter Filter
Flexible installation (2pcs.) (3pcs.)
(Bolt pitch)
377
Ceiling concealed 82
48
30
F E
(All surroundings) D
C
(Bolt pitch) ARGD07-14 ARGD18 ARGD24
10
Floor concealed 43 A 700 900 1100
163
119
198
168
89
78
55
47
78
58 59
AIRSTAGE Indoor units
TM
Models
ARGA24GBTH
ARGA30GBTH
ARGA36GBTH
Duct indoor unit
ARGA45GBTH Two-direction drain piping
Optional parts
Remote Sensor Unit : UTY-XSZX Flange (Round) : UTD-RF204
Long Life Filter : UTD-LF25NA IR Receiver Unit : UTB-YWC
Flange (Square) : UTD-SF045T Drain Pump Unit : UTZ-PX1NBA
Specifications
Model name ARGA24GBTH ARGA30GBTH ARGA36GBTH ARGA45GBTH
Feature Power source Single-phase, 230V, 50Hz
Capacity Cooling 7.1 9.0 11.2 12.5
kW
Heating 8.0 10.0 12.5 14.0
Slim & Compact design Input power W 190 188 312 312
Airflow rate High 1,280 (356) 1,280 (356) 1,720 (478) 1,720 (478)
In the case of bottom return air connection, not only does the 1,200 1,135mm Med
m3/h
1,210 (336) 1,210 (336) 1,670 (464) 1,670 (464)
(l/s)
indoor unit design allow for installation in a narrow ceiling Control box is now included as Low 1,130 (314) 1,130 (314) 1,600 (444) 1,600 (444)
space of up to 270mm, Further space savings have been part of the main chassis
Static pressure range 30 to 150 30 to 150 30 to 150 30 to 150
achieved by mounting the electrical control box internally Pa
Standard static pressure 100 100 100 100
inside the chassis. 270mm Sound pressure High 38 40 43 43
level Med dB(A) 36 38 41 41
Low 34 36 39 39
Dimensions (H x W x D) mm 270 × 1,135 × 700 270 × 1,135 × 700 270 × 1,135 × 700 270 × 1,135 × 700
One touch operating and easy to
install long life filter (Optional Parts) Weight kg(lbs) 39 (86) 42 (93) 42 (93) 42 (93)
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.U.) 25 / 32
168
pressure design. Large bottom 32 32
panel: 1 piece ø200
(knock 1
out hole)
240
240
138
281
264 264 264
3
447(Bolt pitch)
82
New model 1
138
700
It can also be installed in wide spade 3
4 2
when high static pressure is required,
such as for offices.
161
75
173
ø205 hole
3
1.Control box Front view
2
2.Fan casing P.C.D. ø225
240
3.Fan 1015 107
Bottom panel: 270
4.Motor 121 1135
2 pieces
Top view
Easy setting by using remote controller Side view (L) Side view (R)
The change of static pressure Structural improvement is attained by making the bottom panel two pieces, front and rear.
1 Refrigerant piping flare connection (Liquid) :
The internal fan casing is also manufactured in two pieces, namely upper and lower. The
range is possible by remote maintenance of the motor and fan can be easily carried out by removing the rear panel 2 Refrigerant piping flare connection (Gas) :
controller and the lower part of the casing while leaving the main chassis installed. 3 Drain piping connection (Drain pipe) Rear view
60 61
AIRSTAGE Indoor units
TM
400
550
450
by reducing the basic chassis
ARGC36GBTH and the overall material weight.
ARGC72GBTH 1,050 500 700
1,587
700
ARGC90GBTH 1,587
Optional parts
Long-Life Filter : UTD-LF60KA (For ARGC36GBTH)
IR Receiver Unit : UTB-YWC
Remote Sensor Unit : UTY-XSZX
ARGC96
Specifications
Model name ARGC36GBTH ARGC72GBTH ARGC90GBTH ARGC96GATH
Feature Power source Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz
Capacity Cooling 11.2 22.4 25.0 28.0
kW
Heating 12.5 25.0 28.0 31.5
Static pressure selection Low energy consumption by high Input power W 207 681 819 838
Airflow rate High 1,990 (553) 3,900 (1,083) 4,300 (1,195) 4,850 (1,347)
By using DC fan motor, it is possible to change static pressure range efficiency DC fan motor Med
m3/h
1,680 (467) 3,300 (917) 4,000 (1,111) 4,250 (1,181)
(l/s)
from 0 to 200Pa (ARGC36) / 300Pa (ARGC72/90/96). Low 1,330 (369) 3,000 (833) 3,500 (972) 3,600 (1,000)
Improved motor efficiency from previous model.
The change of static pressure range is possible by function setting Static pressure range 0 to 200 0 to 300 0 to 300 0 to 300
Pa
with wired / wireless remote controller. Standard static pressure 100 150 150 150
Sound pressure High 42 47 48 48
level Med dB(A) 36 43 46 45
Low 32 40 44 42
[Pa]
200 or 300 Dimensions (H x W x D) mm 400 × 1,050 × 500 450 × 1,587 × 700 450 × 1,587 × 700 550 × 1,587 × 700
Weight kg(lbs) 40 (88) 84(185) 84(185) 105(231)
(ARGC36 type) (ARGC72 / 90 / 96 type) Connection Liquid 9.52 (Flare) 12.70 (Brazing) 12.70 (Brazing) 12.70 (Brazing)
pipe diameter Gas mm 19.05 (Flare) 22.22 (Brazing) 22.22 (Brazing) 22.22 (Brazing)
Drain hose diameter (I.D./O.U.) 25 / 32 25 / 32 25 / 32
0
[m3/h]
527
Cutting off the corners of the conventional indoor unit front panel and
427
504
404
411
311
327
227
fan casing, has enabled less turbulent air flow. Low noise is realized by 71 Rear view 81 Rear view 81
Rear view
adopting a plastic case and a plastic fan.
42
42
371 1587 1587
400 1,080(Bolt pitch) 356 450 8 1410(BOLT PITCH) 550 1410 (BOLT PITCH)
324 1,000 208 370 15 470 15 8
14 1250 149 1250 149
38
65 65
38
862 108
29
123
139
653(BOLT PITCH) 29
41
653(BOLT PITCH)
25
50
500(Bolt pitch)
50
25
1
Plastic fan
700
700
585
Ø 225mm 500mm 2
50
25
3
50
25
Heat exchanger 4 P160×2 Ø3 150×7=1050 75 P160×2 P150×7=1050 75
Side view (R) =320 15 Side view (R) =320 15 1200 125
851 1200 125
295 350 35 1450 117 350 35 1450 117
1,050 85
Med. noise level Side view (L) Top view Side view (L) Top view Side view (L) Top view
36 dB(A)
400mm
(ARGC36 type)
1 Refrigerant piping flare connection (Liquid) 1 Refrigerant pipe Áare connection (Liquid) 1 Refrigerant pipe Áare connection (Liquid)
Casing (Plastic)
2 Refrigerant piping flare connection (Gas) 2 Refrigerant pipe Áare connection (Gas) 2 Refrigerant pipe Áare connection (Gas)
3 Drain piping connection 3 Drain hose 3 Drain hose
62 63
AIRSTAGE Indoor units
TM
450
Models
400
overall material weight.
ARGC45GATH
ARGC60GATH
1,050 500 1,550 700
ARGC72GATH
(ARGC36 type) (ARGC72 / 90 type)
ARGC90GATH
Optional parts
ARGC45 ARGC60 ARGC72 ARGC90
Long-Life Filter : UTD-LF60KA (For ARGC45/60GATH)
IR Receiver Unit : UTB-YWC
Remote Sensor Unit : UTY-XSZX
Specifications
Model name ARGC45GATH ARGC60GATH ARGC72GATH ARGC90GATH
Feature Power source Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz
Capacity Cooling 12.5 18.0 22.4 25.0
kW
Heating 14.0 20.0 25.0 28.0
Static pressure selection Input power W 715 730 1,110 1,250
Airflow rate High 3,500 (972) 3,500 (972) 3,900 (1,083) 4,300 (1,195)
Models : ARGC72 / ARGC90 Med
m3/h
3,000 (833) 3,000 (833) 3,300 (917) 4,000 (1,111)
(l/s)
2 Types of static pressure mode are selectable. Low 2,460 (683) 2,460 (683) 3,000 (833) 3,500 (972)
Static pressure range 100 to 250 100 to 250 50 to 300 100 to 300
High Static Pressure Duct (ARGC72) Pa
Standard static pressure 100 100 260 250
Max. The adoption of a single phase fan motor allows Sound pressure High 49 49 51 53
427
403
318
235
Cutting off the corners of the conventional indoor unit front panel and Rear view 71 Rear view
fan casing, has enabled less turbulent air flow. Low noise is realized by 400 1,080(Bolt pitch)
371
356
450 1550 98 Main drain port
370 15 Safety drain port
adopting a plastic case and a plastic fan. 324 14 1,000 208 68
8 1410 (Bolt pitch)
1251 151
29
33
56
862 108
123
139
41
25
50
1
700
585
2
Plastic fan
50
25
Ø 225mm 500mm
3
4 P160×2 P150×7=1050 75
Heat exchanger Side view (R) =320 15 Side view (R)
Ø3 1199 127
851 350 35
295 1454 85
1,050 85
Med. noise level Side view (L) Top view Side view (L) Top view
45 dB(A)
400mm
(Drain hose)
64 65
AIRSTAGE Indoor units
TM
Models
ARGN18GATH
ARGN24GATH
ARGN30GATH
ARGN34GATH
ARGN36GATH
static pressure range static pressure range
ARGN45GATH
50 to 250Pa 50 to 300Pa
(30 / 34class) (36 / 45class)
Specifications
Model name ARGN18GATH ARGN24GATH ARGN30GATH ARGN34GATH ARGN36GATH ARGN45GATH
Feature Power source Single-phase, 230V, 50Hz
Capacity Cooling 5.6 7.1 9.0 10.0 11.2 12.5
kW
Heating 6.3 8.0 10.0 11.2 12.5 14.0
Large airflow volume Input power W 154 205 306 432 572 572
Airflow rate High 2,280 (633) 2,640 (733) 3,200 (889) 3,720 (1,033) 4,120 (1,145) 4,120 (1,145)
It can be installed in places such as early replacement of air required by Med
m3/h
Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
(l/s)
large airflow volume. Low Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
Static pressure range 50 to 100 50 to 150 50 to 250 50 to 250 50 to 300 50 to 300
Pa
Standard static pressure 50 50 50 50 60 60
Sound pressure High 35 37 40 43 45 45
level Med dB(A) Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
Low Ƅ Ƅ Ƅ Ƅ Ƅ Ƅ
Dimensions (H x W x D) mm 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700 450 × 1,587 × 700
Weight kg(lbs) 84 (185) 84 (185) 84 (185) 84 (185) 84 (185) 84 (185)
Connection Liquid (Flare) 9.52 9.52 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 15.88 15.88 15.88 19.05 19.05
Drain hose diameter (I.D./O.U.) 25 / 32
Installation styles
Rear view
Air Flow
Top view
66 67
AIRSTAGE Indoor units
TM
Models
ABGA12GATH
ABGA14GATH Super vane
ABGA18GATH 655
Double Louvre Super vane with newly developed special
ABGA24GATH configuration boosts airflow sending cool air quickly to every
corner of the room.
990
Floor standing 199
Specifications
Model name ABGA12GATH ABGA14GATH ABGA18GATH ABGA24GATH
Feature Power source Single-phase, 230V, 50Hz
Capacity Cooling 3.6 4.5 5.6 7.1
kW
Heating 4.0 5.0 6.3 8.0
Flexible installation Input power W 30 42 74 99
Airflow rate High 660 (183) 780 (216) 1,000 (277) 1,000 (277)
Example for floor installation Example for ceiling installation Med
m3/h
(l/s)
570 (158) 640 (177) 720 (199) 820 (227)
Floor console Under ceiling Low 490 (136) 550 (152) 580 (161) 680 (188)
Sound pressure High 36 40 46 47
level Med dB(A) 32 36 39 42
Low 28 34 35 37
Dimensions (H x W x D) mm 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655 199 × 990 × 655
Weight kg(lbs) 25 (55) 26 (57) 26 (57) 27 (59)
Connection Liquid (Flare) 6.35 6.35 9.52 9.52
pipe diameter Gas (Flare) mm 12.70 12.70 15.88 15.88
Drain hose diameter (I.D./O.U.) 25 / 32
5 steps selectable
3 2
1
4
68 69
AIRSTAGE Indoor units
TM
Fresh
air Max.
Models
500mm
ABGA30GATH Indoor Outdoor
ABGA36GATH
ABGA45GATH
ABGA54GATH
Slim & Compact design
Optional parts
Hight
Specifications
Model name ABGA30GATH ABGA36GATH ABGA45GATH ABGA54GATH
Feature Power source Single-phase, 230V, 50Hz
Capacity Cooling 9.0 11.2 12.5 14.0
kW
Heating 10.0 12.5 14.0 16.0
Installation Input power W 66 85 131 180
Airflow rate High 1,630 (452) 1,690 (469) 2,010 (558) 2,270 (629)
m3/h
Open Concealed Wall mounted Med 1,370 (379) 1,400 (389) 1,600 (444) 1,780 (493)
(l/s)
(Field Supplied) Low 1,140 (316) 1,170 (325) 1,230 (342) 1,280 (355)
Sound pressure High 42 45 48 51
level Med dB(A) 38 38 42 45
Low 33 34 35 36
Dimensions (H x W x D) mm 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700 240 × 1,660 × 700
Weight kg(lbs) 46 (101) 48 (106) 48 (106) 48 (106)
Connection Liquid (Flare) 9.52 9.52 9.52 9.52
pipe diameter Gas (Flare) mm 15.88 19.05 19.05 19.05
Drain hose diameter (I.D./O.U.) 25 / 32
General installation pattern Installation pattern where part Installation which fixes the indoor unit to the
Note : Specifications are based on the following conditions.
which suspends the indoor of the indoor unit is embedded wall by the use of wall brackets (Field supplied). Cooling : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
unit from the ceiling. into the ceiling. This type of installation can be used Heating : Indoor temperature of 20ÝCDB / (15ÝCWB), and outdoor temperature of 7ÝCDB / 6ÝCWB.
Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
when the ceiling space is insufficient.
low
air-f
ist ance
Lo ng d
5 steps selectable
3
1 Refrigerant piping flare connection (Liquid)
4 2 Refrigerant piping flare connection (Gas) 3
4 steps selectable 3 Drain piping connection 2 1 3
70 71
AIRSTAGE Indoor units
TM
Symmetrical design
Symmetrical, clean design that suits all interiors.
Specifications
ASGA07GACH ASGA09GACH ASGA12GACH ASGA14GACH ASGE07GACH ASGE09GACH ASGE12GACH ASGE14GACH
Model name
Feature ASGA07GATH ASGA09GATH ASGA12GATH ASGA14GATH
Power source Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz
Capacity Cooling 2.2 2.8 3.6 4.5 2.2 2.8 3.6 4.5
kW
Filter features Heating 2.8 3.2 4.1 5.0 2.8 3.2 4.1 5.0
Input power W 17 18 22 34 15 16 21 34
High quality air conditioning by incorporation of high performance Deodorizing effect (Odor reduction rate) Airflow rate High 490 (136) 500 (139) 560 (156) 670 (186) 490 (136) 500 (139) 560 (156) 680 (189)
filter. Ammonia Trimethylamine Med
m3/h
450 (125) 450 (125) 480 (133) 490 (136) 450 (125) 450 (125) 480 (133) 490 (136)
(l/s)
(ppm) (ppm) Low 370/420*1 (103/117*1) 370/420*1 (103/117*1) 420 (117) 420 (117) 370/420*1 (103/117*1) 370/420*1 (103/117*1) 420 (117) 420 (117)
160 160 Sound pressure High 35 36 39 44 34 35 38 43
With no filter
With no filter
120 120 level Med dB(A) 33 33 35 37 32 32 34 35
Ion Deodorization Filter
80 80 New filter Low 27 / 31*1 27 / 31*1 31 32 26 / 30*1 26 / 30*1 30 30
40 New filter 40 Dimensions (H x W x D) mm 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215 275 × 790 × 215
The filter deodorizes by powerfully decomposing absorbed odors using Weight kg(lbs) 9 (20) 9 (20) 9 (20) 9 (20) 9 (20) 9 (20) 9 (20) 9 (20)
0 0
the oxidizing and reducing effects of ions generated by the 0 30 60 120 (min) 0 30 60 120 (min) Connection Liquid (Flare) 6.35 6.35 6.35 6.35 6.35 6.35 6.35 6.35
ultra-fine-particle ceramic. pipe diameter Gas (Flare) mm 12.70 12.70 12.70 12.70 12.70 12.70 12.70 12.70
Hydrogen sulfate
(ppm) Drain hose diameter (I.D./O.U.) 13.8 / 15.8 to 16.7 13.8 / 15.8 to 16.7
160 EV Kit (option) - - - - UTR-EV09XB UTR-EV09XB UTR-EV14XB UTR-EV14XB
With no filter
120 Note : Specifications are based on the following conditions.
Apple-catechin Filter 80 Cooling : Indoor temperature of 27ÝCDB / 19ÝCWB, and outdoor temperature of 35ÝCDB / 24ÝCWB.
New filter Testing organization : Heating : Indoor temperature of 20ÝCDB / (15ÝCWB), and outdoor temperature of 7ÝCDB / 6ÝCWB.
40 Environmental Sanitary Inspection Center Pipe length : 7.5 m; Height difference between outdoor unit and indoor unit : 0 m. Voltage : 230 [V].
Apple-catechin filter uses static electricity to clean fine particles and 0 Test method : *1 : This value is under cooling operation.
dust in the air. 0 30 60 120 (min) Deodorization Test
The Auto Swing Louvre function Powerful output even compact design Width 790
215
ensures that the air direction
corresponds to the mode selected.
Though the indoor unit is compact, it features a 790mm
large, high pressure cross fan (90mm diameter)
in a centre mounted configuration and a
Lambda type heat exchanger to provide plenty
of power.
275
1
470
2 3
530
660
EV kit (UTR-EV09XB/ UTR-EV14XB ) Optional parts:
Sw
1 2
3
65
ing
416 19
222 32
4
1 Refrigerant pipe flare connection (Liquid)
790mm
Vertical installation
Install the unit as confirmed direction.
wire
UPWARD
121
Step
by more than 5°
Install the unit as confiremed direction .
97
Install the unit where it will not be tilted
by more than 5°
Horizontal installation
65
OUTDOOR UNIT INDOOR UNIT
Swing
SIDE SIDE
72 73
AIRSTAGE Indoor units TM
Models Models
ASGA18GACH ASGA18GATH
ASGA24GACH ASGA24GATH
ASGA30GACH ASGA30GATH
DC fan motor
998mm
Specifications
ASGA18GACH ASGA24GACH ASGA30GACH
Model name
Feature ASGA18GATH ASGA24GATH ASGA30GATH
Power source Single-phase, 230V, 50Hz
Capacity Cooling 5.6 7.1 8.0
kW
More comfort airflow by adopting power diffuser Heating 6.3 8.0 9.0
Input power W 32 60 91
“Vertical airflow” “Horizontal airflow” does not blow cool air Airflow rate High 840 (233) 1,100 (305) 1,240 (343)
provides powerful floor level heating directly at the occupants in the room Med
m3/h
770 (213) 910 (252) 980 (271)
(l/s)
Low 690 (191) 730 (202) 770 (213)
5 5
(24/30) (24/30) Sound pressure High 41 48 52
level Med dB(A) 39 43 45
998
Organic coating
fin used heat 5 steps selectable
exchanger
Apple-catechin 320
Filter
Air Filter
520
1
The filter deodorizes by powerfully Apple-catechin filter uses static electricity
decomposing absorbed odors using the to clean fine particles and dust in the air.
2 1 Refrigerant piping flare connection (Liquid)
oxidizing and reducing effects of ions
520
generated by the ultra-fine-particle 2 Refrigerant piping flare connection (Gas)
Sw
3
ceramic. 3 Drain hose connection
ing
74 75
User friendly control system
provides individual control to centralized control
The AIRSTAGE control system can perform air conditioning control of individual
application, such as linking with the building control system, linking with a single
AIRSTAGE
TM
CONTROL SYSTEM
INDIVIDUAL CONTROLLER
CENTRALIZED CONTROLLER
CONVERTOR / ADAPTOR
76 77
AIRSTAGE Control Systems TM
SHOP OFFICE
Individual Centralized Control Integrating Control (Interface) Individual Control Centralized Control Integrating Control (Interface)
Type
ype Control Type
Network External
Wired Remote Simple Remote Wireless Remote Group Remote Central Remote Touch Panel System BACnet® MODBUS® KNX®
Convertor Switch
Controller Controller Controller Controller Controller Controller Controller Gateway Convertor Convertor
for LONWORKS® Controller
Remote Management z z
78 79
TM
Control Systems
User’s needs are supported by offering a variety of controls, such as individual control,
central control and building management control options.
Network Convertor
(DC power supply) Single split
UTY-VTGX
Network Convertor
(AC power supply) Single split
Card-key
(Field supplied)
Internet device UTY-VTGXV
80 81
AIRSTAGE Control Systems TM
Item
Wired Remote Controller Wired Remote Controller Simple Remote Controller Simple Remote Controller *1 Wireless Remote Controller Group Remote Controller Central Remote Controller Touch Panel Controller System Controller Lite System Controller
(Touch panel) Software Software
Model name UTY-RNRGZ2 UTY-RLRG UTY-RSRG UTY-RHRG UTY-LNHGU UTY-CGGGU UTY-DCGG UTY-DTGGZ1 UTY-ALGXZ1 UTY-APGXZ1
Max. controllable remote controller groups 1 1 1 1 1 8 100 400 400 1600
Max. controllable indoor units 16 16 16 16 16 128 100 400 400 1600
Max. controllable groups — — — — — — 16 400 400 1600
On / Off z z z z z z z z z z
Operation mode setting z z z — z z z z z z
Air conditioning control function
Address display z z z z — z z z z z
Room temp z — z z — — — z — —
Multi language z — — — — — z z z z
Summer time z — — — — — z z z z
Name registration z — — — — — z z z z
Backlight z — z z — — z z — —
2D floor layout / 3D building display — — — — — — — — — z
Period Week Week — — — Week Week Year Year Year
Schedule
timer On/off, Temp,
8 4 — — — 4 20 20 144 144
Mode, Times per day
On/off timer z z — — z — — — — —
Timer
Sleep timer — — — — z — — — — —
Program timer — — — — z — — — — —
Auto off timer z z — — — — — z — —
Day off z z — — — — z z z z
Min. unit of timer setting (Minutes) 10 • 30 30 — — 5 10 10 10 10 10
Status monitoring system — — — — — — z z z z
Electricity charge apportionment — — — — — — — { { z
Error history z z — — — z z z z z
Emergency stop — — — — — — z*2 z*2 — —
Control
Remote management — — — — — — — z { z
Energy saving management — — — — — — — — { {
E-mail notification for malfunction — — — — — — — z z z
z z — — — z z z z z
Key lock Child lock Child lock Child lock Password setting Password setting Password setting Password setting
*1 "Operation mode" setting is not available for this model. *2 This function is available only through external input control.
82 z: Supported {: Optional function — : Not supported yet 83
AIRSTAGE Control Systems Individual Controller
TM
Max. controllable
Room temperature
Functions Y1 Y2 Y1 Y2
Individual Thermo Weekly Auto off Auto Address Setting/Setting Position Notification
control sensor timer timer • Reduce errors and install time compared with the current specification
Set interval time (17:00 to 24:00)
Rotary SW
• When will be set remote controller groups, can also be set automati-
ON OFF ON Auto OFF ON Auto OFF
cally new Wired remote controller address
• After auto address setting of new wired remote controller groups, what
1 hour 1 hour number can also confirm addresses
Accurate and comfortable control
Normal Time Over Time
• Indoor temperature can be detected accurately by the inclusion of a Address ƙ 04 03 02 01
thermo sensor in the body of the wired controller. 8 17 24
Ex.) At interval time hour (17:00 to 24:00) to prevent forgetting to turn off
Set off time : 1 hour
Summer Time display The appropriate indoor unit
performs the air blow and
• This function can be set easily from LED lamps blink.
Menu screen 2 schedules Weekly Timer
• 2 schedules such as for the summer and winter can be set.
• 8 setting changeable per day of week (Setting items: On/Off, 05
Temperature, Mode, Time)
Ex)
Easy Maintenance
Error History Display
• The errors that occur in the indoor unit or
Child lock
remote controller are saved as a history.
• Lock / unlock method: Push the ON/OFF
• A maximum of 32 error incidents can be
button and the screen (4 seconds)
saved.
Set Temperature Auto Return
• The setting temperature automatically returns to the previous
setting temperature.
• The time range in which the set temperature can be changed is 10
to 120 minutes.
Language Setting
Page 1/ 3
Date Setting
• Backlight enable easy operation in a This makes it easy to identify the indoor Temp. Unit
Setting
R.C.Group
Name Setting
Functions Functions
High performance and compact size High visibility and Corresponding to various applications
In addition to the individual control, weekly timer, and various energy easy operation • Vertical louver control:
saving controls can be realized using only one remote controller. Vertical air flow direction can be adjusted for Duct types with auto
• "Mode", "Set Temp", and "Fan" are
displayed at large size on the top screen. louver and Cassette types, which are installed in hotels and confer-
• Each function to be set is indicated by ence rooms, can be adjusted.
an icon. Sophisticated control buttons
Individual Thermo Weekly Auto OFF Simple operation with easy
control sensor timer timer
• Control guide is displayed and operation 4-way navigation pad
is simple and straightforward.
Set contents can be displayed
clearer with large LCD.
Set temperature change Auto return Set temperature change Auto return
OFF 24°C 25°C
Weekly timer function Set temperature upper and lower limit setting Room temperature
• Not only time setting On / Off, but also setting of the operation mode • The set temperature range can be set for each operation mode. sensor
and set temperature can be set by Weekly timer function. (Cooling / Heating / Auto)
ON OFF ON OFF During Cooling During Heating
24°C 30°C 30°C
25°C
Working hour Working hour 25°C
Specifications Specifications
Model name UTY-RLRG Model name UTY-RSRG UTY-RHRG
Power Supply DC 12V Power Supply DC 12V
Dimensions (H x W x D) (mm) 120 x 120 x 17 Dimensions (H x W x D) (mm) 120 x 75 x 19.4
Weight (g) 170 Weight (g) 120
DC12V is supplied by indoor unit. DC12V is supplied by the indoor unit.
86 87
AIRSTAGE Control Systems Individual Controller
TM
Max. controllable
UTY-LNHGU 4 UTB-YWC
daily timers
Simple and sophisticated operations Necessary to control for all Duct types* by Wireless Remote Controller
with a choice of 4 daily timers *Only Large Airflow Duct can not be connected to IR Receiver Unit.
• A single controller controls up to 16 indoor units. • Up to 16 indoor units can be controlled with one remote controller.
• Suitable for hotels or offices as it is easily operated with no complex functions.
Functions
Wiring connection
Functions
Wireless
Built-in daily timer Easy installation and operation Remote Controller
Select from 4 different timer programs : Code selector switch Duct Type Indoor Unit
On / Off / Program / Sleep prevents indoor unit IR Receiver Unit
Program timer : The program timer operates the ON and OFF timer mix-up. (Up to 4 codes
once within a 24 hour period. can be set.)
Sleep timer : The sleep timer function automatically corrects the set
temperature according to the time setting to prevent excessive cooling Specifications
or heating during sleep hours.
Model name UTB-YWC
Power Supply DC 5V
Wide and precise Dimensions (H x W x D) (mm) 145 x 90 x 30
Cooling operation/dry operation Weight (g) 150
When the sleep timer is set, the set temperature automatically rises
1ÝC every hour. The set temperature can rise up to a maximum of 2ÝC.
T imer setting
Functions
Indoor unit
1ÝC Outdoor unit
2ÝC
3ÝC 4ÝC
Wireless
Remote Controller
30min.
60min.
90min.
Wireless
T imer setting Remote Controller
Specifications Specifications
Model name UTY-LNHGU Model name UTY-LRHGB1
Power Supply 1.5V (R03 / LR03 / AAA) x 2 Power Supply DC 5V
Dimensions (H x W x D) (mm) 170 x 56 x 19 Dimensions (H x W x D) (mm) 193.9×193.9×31.2
Weight (g) 85 Weight (g) 140
88 89
AIRSTAGE Control Systems Centralized Controller
TM
Max. controllable
UTY-CGGGU UTY-DCGG
Max. controllable
64 16
groups
group R.C. in a VRF
Group control of indoor units with network system Central control of small- and medium-sized buildings and tenants. The
simple operation operation status of all connected indoor units can be viewed at a glance
on a large LCD monitor to simplify individual control to batched control.
• Up to 8 remote controller groups can be controlled by one Group Remote Controller.
• Up to 64 Group Remote Controllers can be connected in one VRF network system. • Individual control and monitor of 100 indoor units
• Network Convertor (UTY-VGGXZ1) is required to connect Group Remote Controllers to • 5 inch TFT color screen
a VRF network system. • User friendly view and easy operation
(Network Convertor allows up to 4 Group Remote Controllers) • External input / output contact
• Detachable power supply unit
• Corresponds to 7 different languages (English, Chinese, French, German, Spanish, Russian, Polish)
Functions Functions
Group : 3F
Single Group Remote Controller controls and monitors up to 8 remote controller groups. • It allows multiple indoor
Group : Division A Group : Division B Group : Division C
units grouping (Max.16
groups controlled)
Refrigerant Refrigerant • Interlock with external
system 1 system 2 device
Group : 2F
Hotel Group : Tenant A Group : Tenant B Group : Tenant C
Emergency stop
Office & Lounge
function
Guest room
Restaurant Functions
Lounge • Diverse control of indoor units • Remote controller prohibition • Weekly timer • Error history • Automatic clock adjustment
Office room
(All, On / Off, Mode, Temp, Timer, Filter)
Network
Lobby Convertor
Group Remote Controller 1:
To control office room, lounge,
Restaurant restaurant and lobby
(8 remote controller groups)
High performance and compact size Built-in weekly timers Setting pattern 1 Setting pattern 2
Indoor unit registration
Ceiling
ON / OFF, Operating mode, Room temperature and Fan speed setting The weekly timer is provided as a standard function. Power supply unit
start
can be controlled / monitored centrally or individually. 1. The timer can be set up for up to 4 times per day. Power supply unit
Specifications
Model name UTY-DCGG
Control Panel Power Supply Unit
Specifications
Power Supply DC 5 V 100-240V, 50-60Hz, Single phase
Model name UTY-CGGGU Dimensions (H x W x D) (mm) 120 x 162 x 25.7 99 x 135 x 39.2
Power Supply DC 12V Weight (g) 308 355
Dimensions (H x W x D) (mm) 120 x 120 x 18 <PACKING LIST>
Weight (g) 200 Packing List Control Panel / Power Supply Unit / Connecting cable, etc.
DC12V is supplied by a network converter.
90 91
AIRSTAGE Control Systems Centralized Controller
TM
Staff / Employee
92 93
AIRSTAGE Control Systems Centralized Controller
TM
FUNCTIONS SUMMARY
Functions
• Individual calculation at cooling and heating Up/down air direction flap setting z z Auto off timer - z
Block (Tenant) B
• Electricity meter supported
Right/left air direction flap setting z z Day off z z
LAN cable
Individual louver control z*1 z Min. unit of timer setting (Minutes) 10 10
*: Electricity meter (1unit) can be connected to external input connector of the TPC unit. Group setting z z Control
In this case, electricity meter cannot be connected to outdoor unit simultaneously.
RC prohibition z z Status monitoring system z z
Automatic summer time setting Set temp. auto return - z Error history z z
• It prevents the user from forgetting to set summer time. In addition, Human sensor control - z Energy saving management - -
it reduces the time and labor of user.
Display E-mail notification for malfunction - z
Error z z z
Key lock -
Defrosting z z Password setting
Day of week z z
R.C. prohibition z z
Cooling/heating priority z z
Address display z z
Room temp z z
Outdoor low noise operation
Multi language z z
Users can choose from 4 low noise levels, depending on the installation
Summer time z z
environment.
The operaion time can be set using the timer. Time zone setting z z
Name registration z z
Air
conditioning
load factor Heat load
100% down
Capacity
0
Specifications
Model name UTY-DTGGZ1
Operating 58dB
Power Supply 100-240V 50/60Hz, Single phase
sound
Dimensions (H x W x D) (mm) 260 x 246 x 54
0
time Weight (g) 2,150
Quiet priority low noise mode Interface Transmission / LAN / USB / EXT IN / EXT OUT / Reset SW
94 95
AIRSTAGE Control Systems Centralized Controller
TM
Max. controllable
1,600
Lighting facilities
• Up to a maximum of 4 VRF network systems, 1600 indoor units, and 400 outdoor units can
Supported Modbus communication Energy recovery ventilator system
be controlled. Indoor units
(Field supply)
• In addition to air conditioning precision control function, central remote control, electricity
Outdoor air unit system
charge calculation, schedule management, and energy saving functions are strengthened
Remote I/O
and building manager and owner needs are met. Supply & Exhaust fan
VRF Network
Signal Line
100
System Controller Lite has standard functions sufficient for air Outdoor units
Diverse operation management & Data management
conditioner management in small and medium scale buildings . Max. controllable
Schedule management
• Up to a maximum of 1 VRF network system, 400 indoor units, and 100 outdoor units can be 400 • Annual schedules can be set for each remote controller group / user defined group.
controlled. Indoor units
• Start / stop, operating mode, remote controller prohibition, and temperature settings can be set up
• In addition to air conditioning precision control function, a variety of management software
to 143 times per day at 10 minute intervals for up to 101 configurations for each remote controller
is available as an option to give customers a wide range of choice.
group.
• Settings can be made for periods straddling midnight.
• Allows programming of special settings for holidays, including public holidays, for a complete year.
Functions • Low noise operation of outdoor unit can be scheduled.
User friendly view and operation Diverse control of indoor and outdoor unit Error display & E-mail notification
• Click & Operate : The property is shown visually from the perspective • Freely define groups for batched control : Indoor units can be freely • Indoor unit operation state, operation mode, etc. are displayed Error is notified with popup message, audible sound and E-mail
most suitable for operation and operated accordingly (Click & grouped for simple batched control from a tree menu. Grouping by • Indoor unit start / stop and operation mode switching real time when error occurs. Error for the past 1 year are logged
Operate). You can select from among the 4 displays of site, building, hierarchal structure, such as by section, division or department is • Room temperature set point limitation and can be reviewed later.
floor, or list. possible.
Click & Operate the whole building ! Properties can be shown using one of the four Click & Operate any specified unit(s)!
Remote controller prohibition Data base import/export
displays of site, building, floor, or list.
This prohibits changes to the operation mode, temperature, Imports/exports registration data, layout data, and image data.
start/stop, etc. Only the administrator can make this setting.
each tenant. This information is then used to calculate the charges for the
distribu
ibu
bution
tion
electricity consumed for air conditioning by each tenant from the total boardd
Tenant A-1 Tenant A-2 Tenant A-3
Batched control of freely selected units electricity charges in the bill from the electric power company. (See figure
P r
Powe
Pow
at right) distribu
ibu
bution
tion
Outdoor Tenant A-4 Tenant A-5 Tenant A-6
boardd
Building view
The detailed calculation takes into consideration such things as unused unit
rooms and nighttime electricity charges and shows them in a charges
calculation sheet.
The floor layout drawing Tenant B-1 Tenant B-2 Tenant B-3
Note: can be imported to easily
2D floor layout / 3D building make the settings for the
display are not available for Click & Operate the whole floor ! actual building. 3Ø, 4 wire 400V, 50Hz
System Controller Lite. Floor view Tenant C-1 Tenant C-2 Tenant C-3 1Ø, 2wire 230V, 50Hz
Click & Operate the unit !
Batched control of freely selected units
96 97
TM
Control Systems Centralized Controller
FUNCTIONS SUMMARY
System controller System controller lite
Functions Function Type
UTY-APGXZ1
Option
UTY-PEGXZ1 UTY-ALGXZ1
Option
UTY-PLGXR2
Option
UTY-PLGXA2
Option
UTY-PLGXE2
Option
UTY-PLGXX2
Max. VRF networks supported 4 - 1 - - - -
Max. indoor unit / remote controller groups per VRF network 400 - 400 - - - -
System
Max. outdoor units per System controller 100 - 100 - - - -
Remote management Standard for System Controller
specification
Max. indoor units / remote controller groups per System controller
Max. outdoor units per System controller
1600
400
-
-
400
100
-
-
-
-
-
-
-
-
Option for System Controller Lite UTY-PLGXR2 Multi site display 10 - 10 - - - -
Number of building / 1 site 20 - - - - - -
Number of floor per 1 site 200 - - - - - -
System Controller may be used on site or remotely over various Number of floor per 1 building 50 - - - - - -
Site
networks for remote central control. System Controller requires Remote central control supervision
3D graphical layout view z - - - - - -
2D graphical layout view z - - - - - -
2 softwares working together. VRF Controller runs on site and 1 VRF Explorer can control or monitor up to 10 sites.
List display z - z - - - -
Tree display z - - - - -
communicate with VRF system. VRF Explorer runs remotely and VRF Explorer Group display z -
z
z - - - -
provides user interface and communicate with the VRF Controller. VRF VRF Controller Error
Error notification z - z - - - -
Building management company, Audible alarm z - z - - - -
Controller and VRF Explorer program may run in a single PC or in A maximum of management center, etc.
management
Error e-mail notification z - z - - - -
different PCs separated by network. By using VRF Explorer software, 10 locations, such as
offices or factories History
Error history
Operation history
z -
-
z -
-
-
-
- -
z z - -
one PC can perform central control of 10 VRF system sites with max. 20 Control history z - z - - - -
On/Off z - z - - - -
buildings per site. Operation mode z - z - - - -
VRF Controller Room temperature z - z - - - -
Internet Fan speed z - z - - - -
or
Telephone Line Individual Air flow direction z - z - - - -
On site central control
or
LAN control Economy mode z - z - - - -
Room temperature set point limitation z - z - - - -
Operation
Max. 4 VRF network systems per site control
Test operation z - z - - - -
Antifreeze z - z - - - -
Outdoor unit low noise setting z - z - - - -
Internet Remote control prohibition setting z - z - - - -
Individual
or Temperature upper and lower limit setting z - z - - - -
management
Telephone Line Filter sign reset z - z - - - -
or 1 VRF Controller can be monitored from any number Memory operation z - z - - - -
Other
LAN of VRF Explorers (Up to 5 connections simultaneously). Pattern operation z - z - - - -
Annual Schedule z - z - - - -
VRF Explorer Building Management Company A Special day setting z - z - - - -
VRF Explorer
(In charge of the day shift) On /off per day 72 - 72 - - - -
VRF Explorer Schedule On / off per week 504 - 504 - - - -
Central Monitoring Screen
VRF Explorer Day off z - z - - - -
for all Properties Min. unit of timer setting (Minutes) 10 - 10 - - - -
Low noise mode Weekly schedule z - z - - - -
Remote monitoring z - - z - - -
Special Property Detailed Building Remote Remote operation control z - - z - - -
Monitoring Screen Management Company B managemment Remote function setting z - - z - - -
(In charge of the night shift)
Internet
or
Office Management Center Web Remote Controller z - - z - - -
Telephone Line
or Apportionment charge/bill calculation z - - - z - -
LAN
VRF Controller Tenant (block) setting z - - - z - -
VRF Explorer Electricity
Common facilities apportionment setting z - - - z - -
charge
Rated power consumption allotment setting z - - - z - -
apportionment
Individual calculation at cooling and heating - z* - - z - -
VRF Explorer Electricity meter supported - z - - z - -
Indoor unit rotation - z - - - z -
Security Company Peak cut control - z - - - z -
Energy Outdoor unit capacity save - z - - - z -
saving Record of energy saving operation - z - - - z -
Headquarters Management Center management Energy saving information - z - - - z -
Power consumption monitor - z - - - z -
Electricity meter supported z - - z -
External Device Monitor z - - - - - z
Control Control z - - - - - z
while maintaining comfort. The indoor unit operation stoppage rate can winters by averaging the power saving effect of each refrigerant system. Graphic accelerator Microsoft® DirectX® 9.0c compatible
be selected. You can select from 50% or more of the capacity upper limit. Software Adobe® Reader® 9.0 or later
• Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)re.
summer capacity
upper limit For System controller For System controller Lite
Type Option Option
System controller System Controller Lite Electricity charge
Cold day of Energy manager Remote access Energy saving Central Control
winter
apportionment
Model name UTY-APGXZ1 UTY-PEGXZ1 UTY-ALGXZ1 UTY-PLGXR2 UTY-PLGXA2 UTY-PLGXE2 UTY-PLGXX2
Outdoor
O d unit
i capacity
i
control screen Time WHITE-USB-KEY 1 1 1 1 1 1 1
IIndoor
d unit
it rotation
t ti screen
*1: Software protection key to be inserted in a USB slot running System Controller or System Controller Lite.
System Controller or System Controller Lite may only run on a PC with WHITE-USB-KEY. However, WHITE-USB-KEY is not required for remote VRF Explorer software.
98 99
AIRSTAGE Control Systems Convertor / Adaptor
TM
BACnet® Gateway 4
VRF network
systems
BACnet® Gateway (Hardware) 1
VRF network system
Max. controllable
WHITE-USB-KEY
NEW UTY-ABGXZ1 (Software Protection Key)
Max. controllable
NEW UTY-VBGX 32
400
Outdoor units
Refrigerant system
• It is possible to connect medium to large sized BMS to VRF network system via BACnet®, a global standard for open networks. • BACnet® Gateway enables to connect a BMS and FG VRF system.
• A maximum of 128 indoor units and 32 refrigerant system can be connected to a single BACnet® Gateway. Max. controllable
• A maximum of 1600 indoor units with 4 VRF network systems (a maximum of 400 indoor units & 100 outdoor units for one network system) Max. controllable
can be connected to one BACnet® Gateway.
1,600
• Compatible with BACnet® (ANSI / ASHRAE-135-2010) application specific controller (B-ASC).
• Compatible with BACnet®/IP over Ethernet.
128
• It is possible to control or monitor VRF network system from BMS via BACnet® Gateway. Indoor units
Indoor units
• Compatible with BACnet® (ANSI / ASHRAE-135-2012) application specific controller (B-ASC).
• Compatible with BACnet®/IP over Ethernet.
• Scheduling function, Alarm & Event functions as well as Electricity Change Apportionment function are provided in BACnet® Gateway. Functions
• Connection between VRF network system to personal computer is possible via small U10 USB interface. However, both U10 USB interface &
personal computer are field supplied items.
• Corresponds to 7 different languages, English, Chinese, French, German, Spanish, Russian, Polish. Installation example
Max.128 indoor units &
Max.32 refrigerant system
Functions
VRF Indoor unit
Controller
BACnet® Gateway
Installation example Lighting facilities
(Hardware) VRF Indoor unit
Security system
BACnet® Operator
Workstation (B-OWS) Automatic fire alarm interface
BACnet®
VRF network system 1 Windows bind VRF Outdoor unit
Lighting facilities Number of controllable refrigerant system 32 Power Consumption (W) 4.6 (max)
Number of controllable VRF network 1 Dimensions (H × W × D) (mm) 59.6 × 270.4 × 176
VRF network system 2 Number of connectable units / one VRF network 4 Weight (g) 1,200
Security system
USB adaptor
(Field supplied)
BACnet® Gateway Automatic fire alarm interface
Indoor unit Outdoor unit (UTY-ABGXZ1)
Max. controllable
USB adaptor
(Field supplied) WHITE-USB-KEY
Software Protection Key
Ventilation system
Network Convertor for LONWORKS® 4
Units to BMS
• The UTY-VLGX permits central monitoring and control of a VRF network system from a BMS through
a LONWORKS® interface.
128
Indoor units
• Up to 128 Indoor units can be connected to one Network Convertor for LONWORKS®
• Microsoft® Windows® 7 Home Premium (32-bit or 64-bit) SP1, Windows® 7 Professional (32-bit or 64-bit) SP1
• Microsoft® Windows® 8.1 (32-bit or 64-bit), Windows® 8.1 Pro (32-bit or 64-bit) Installation example
Operating system • Microsoft® Windows® 10 Home (32-bit or 64-bit), Windows® 10 Pro (32-bit or 64-bit)
Max.128 indoor units &
[Supported languages] Max.100 outdoor units
English, Chinese, French, German, Russian, Spanish, and Polish
VRF Indoor unit
CPU Intel® CoreTM i3 2 GHz or higher
Controller
• 2 GB or more (for Windows® 7 [32-bit]) Network Convertor
Memory Lighting facilities
• 4 GB or more (for Windows® 7 [64-bit], Windows® 8.1, and Windows® 10) for LONWORKS® VRF Indoor unit
100 101
AIRSTAGE Control Systems Convertor / Adaptor
TM
Max. connectable
MODBUS® Convertor 9
units to one VRF KNX® Convertor (for VRF)
Max. controllable
Functions Functions
Controller
Specifications
Specifications
Model name UTY-VKGX
Model name UTY-VMGX Power supply 220-240 V 50/60 Hz
Power Supply 220-240 V Power consumption (W) 1.5
Input power (W) Max. 2 Dimensions (H × W × D) (mm) 54 × 260 × 150
Dimensions (H x W x D) (mm) 54 × 260 × 150 Weight (g) 1,200
Weight (g) 1,100
Functions Functions
Max. 63
Modbus Network KNX Network
Modbus Interface The Modbus Interface can be used with
The KNX Interface can be used with or
or without Wired Remote Controller.
without Wired Remote Controller.
BMS/Central Home Controller
Controller VRF Indoor unit KNX VRF Indoor unit
Lighting facilities
VRF Indoor unit
or
Security system
VRF Indoor unit
Specifications Specifications
Model name FJ-RC-MBS-1 Model name FJ-RC-KNX-1i
Dimensions (H x W x D) (mm) 93×53×58 Dimensions (H x W x D) (mm) 70×70×28
Weight (g) 85 Weight (g) 70
102 103
AIRSTAGE Control Systems Convertor / Adaptor
TM
Max. controllable
100
• It is the most advanced solution to remotely manage an Air Conditioning system using UTY-VTGXV (AC power supply type) Network
Convertors
all sort of mobile devices such as Smartphones, Tablets and PC
• No separate external power supply required • The network convertors are required when connecting single split
• Can be used for single indoor units and group controlled (up to 16) indoor units system to VRF network system.
• Compact and light weight design
• Connectable to both types of 2-wire and 3-wire remote controllers
UTY-VTGX UTY-VTGXV
DC power supply type AC power supply type
Functions Functions
Installation example
• 2 types of 1 remote controller type and 2 remote controllers type are available.
Indoor unit
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote controllers type.
Internet Smartphone
Smart
Basic control
(Application screen image)
• Turning the units on and off • Room temperature display
• Mode control (Heat, Cool, Dry, Auto, Fan) • Set temperature control
• Fan speed setting • Multi Language • 2-wire and 3-wire type of the wired remote controller can be • A central control can be provided for the single split systems. (Up to
connectable. 100 units of Network Convertor is connectable in one VRF network
• Louver position (Airflow direction setting) • One Scene and Timer
• Power supply (AC220-240V, 50/60Hz) is required for 2 remote system)
controllers type.
Up to 100 units of
Network Converter
Specifications
Model name UTY-VTGX UTY-VTGXV
Specifications
Power Supply polar 3-wire DC12V non-polar 2-wire DC12V 220-240V 50/60Hz, Single phase
Model name FJ-RC-WIFI-1 Input power (W) Max. 1.2 Max. 3
Dimensions (H x W x D) (mm) 108 × 70 × 28 Dimensions (H x W x D) (mm) 140 × 117 × 43 54 × 260 × 150
Weight (g) 80 Weight (g) 250 1,100
104 105
AIRSTAGE Control Systems Convertor / Adaptor
TM
Max. controllable
Network Convertor 16
indoor units External Switch Controller
Max. controllable
Functions
Installation example
Human sensor catches movements of people in
Functions a room, and operates with lower capacity when
people come back to the room, it automatically
SAVE ! AUTO RESTART
returns to previous operation mode. Cooling/Dry +2°C *Max. 30°C
Used for connecting single split system Network Convertor Set temp. Human sensor equipment needs to be
purchased locally. The above example
• Split type systems can be centrally controlled from Touch Panel Heating indicated that a signal is sent to this
External Switch Controller if human
Controller or System Controller through connection to the VRF's Set temp. -4°C *Max. 16°C
sensor does not detect for 20 minutes.
network convertor. Human sensor is not mounted on the
Normal operation Saving operation Normal operation External Switch Controller.
• On / Off Control, Master control, Room temperature and Fan speed
setting via the Network Convertor are available.
• One Network Convertor can be used to connect and control up to 16 Specifications
Group of Single Split
single units. Single Split Model name UTY-TERX
Power Supply DC 6.5-16V
VRF network system Dimensions (H × W × D) (mm) 140 × 117 × 43
USB Weight (g) 250
Adaptor DC12V is supplied by the indoor unit.
System Controller
Big Multi
Please consult your distributor for connectable split type air conditioner.
Signal Amplifier
Up to 100 Network Convertors may be connected in single VRF network system.
One Network Convertor is considered as a single refrigerant system,
irrespective of the number of connected single models.
UTY-VSGXZ1
Used for connecting • Transmission Line length can be extended up to 3,600m with multiple Signal Amplifiers.
Group Remote Controller • Up to 40 signal amplifiers can be installed in a VRF network system.
• A signal amplifier is required,
4 Group Remote Controllers can be connected to a single Network Group (1) When the total wiring length of the transmission line exceeds 500m.
Convertor (UTY-VGGXZ1). Remote Controller
UTY-CGGY (2) When the total number of units on the transmission line exceeds 64.
UTY-CGGG
Functions
Network Convertor
Installation example
VRF network system
B
* 2 refrigerant circuits can be covered by a single Network Convertor (UTY-VGGXZ1) .
Up to a total of 16 Network Convertors (UTY-VGGXZ1) and System Controller C
adaptors can be connected in a single VRF network system. A D
Signal Amplifier
Specifications Specifications
Model name UTY-VGGXZ1 Model name UTY-VSGXZ1
Power Supply 208-240V 50/60Hz, Single phase Power Supply 208-240V 50/60Hz, Single phase
Power Consumption (W) 8.5 Power Consumption (W) 4.5
Dimensions (H x W x D) (mm) 67 x 288 x 211 Dimensions (H × W × D) (mm) 67 x 288 x 211
Weight (g) 1,500 Weight (g) 1,500
106 107
EFFECTIVE HEAT EXCHANGE AND
SIMULTANEOUS FRESH AIR VENTILATION
High Efficiency and low noise levels are achieved by using a highly efficient heat
108 109
Ventilation
UTZ-BD050B Height
UTZ-BD080B 317mm
UTZ-BD025B UTZ-BD035B UTZ-BD050B
UTZ-BD100B UTZ-BD035B/BD050B
Height
388mm
UTZ-BD080B/BD100B
UTZ-BD080B UTZ-BD100B
Specifications
(Tentative)
Rated flow rate 250 m3/h 350 m3/h 500 m3/h 800 m3/h 1000 m3/h
Feature Model No. UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B
Power source Single-phase, 230V, 50Hz
CInput power Extra high / High / Low kW 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
Heat exchange ventilation and normal ventilation Air flow rate Extra high / High / Low m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
External static pressure Extra high / High / Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Heat exchange ventilation
HEAT EXCHANGE
Temperature Exchange
VENTILATION
When a room is cooled or heated, the exhausted cooling / heating energy Extra high / High / Low % 75 / 75 / 77 75 / 75 / 78 75 / 75 / 76 75 / 75 / 76 75 / 75 / 79
Adopts a highly efficient counter-flow Efficiency
is recovered by heat-exchange ventilation. heat exchange element Energy Exchange
Extra high / High / Low % 63 / 63 / 65 66 / 66 / 71 62 / 62 / 64 65 / 65 / 68 65 / 65 / 70
Normal ventilation Heat exchanger Efficiency Cooling
Outside air
The operation is used during periods when the room space requires no Exhaust air Energy Exchange
Extra high / High / Low % 70 / 70 / 72 69 / 69 / 73 67 / 67 / 69 71 / 71 / 74 71 / 71 / 76
cooling or heating effect, i.e. when there is minimal temperature Efficiency Heat pump
difference between the indoor and outdoor environments. Sound pressure level Extra high / High / Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 37.5 / 35.5 / 32.5 37.5 / 37 / 34.5 38.5 / 37.5 / 34.5
Input power Extra high / High / Low W 128 / 123 / 96 190 / 185 / 168 289 / 225 / 185 418 / 378 / 295 464 / 432 / 311
VENTILATION
NORMAL
Air flow rate Extra high / High / Low m3/h 250 / 250 / 190 350 / 350 / 240 500 / 500 / 440 800 / 800 / 630 1000 / 1000 / 700
Supply air
Room air External static pressure Extra high / High / Low Pa 105 / 95 / 45 140 / 60 / 45 120 / 60 / 35 140 / 110 / 55 105 / 80 / 75
Sound pressure level Extra high / High / Low dB* 31.5 / 30.5 / 26.5 33 / 31 / 25.5 38.5 / 38 / 32.5 37.5 / 37 / 34.5 40.5 / 39.5 / 36.5
Dimensions (W × D × H) mm 882 x 599 x 270 1050 x 804 x 317 1090 x 904 x 317 1322 x 884 x 388 1322 x 1134 x 388
Weight kg 29 49 57 71 83
Outlet duct diameter mm 150 150 200 250 250
Energy efficiency and ecology Reverse mountable direct air supply / Operation range °C -10 ~ 40 -10 ~ 40 -10 ~ 40 -10 ~ 40 -10 ~ 40
Energy saving
20%, resulting in significant energy savings. simplified because the air supply / exhaust ducts are straight.
Recovers up to 77% of the heat in the outgoing air.
Since each unit can be mounted in reverse position, only one
Features of heat exchange element inspection hole is needed for two units: Two units can share one Dimensions (Unit : mm)
With the cross-flow element, air moves in a straight line across the inspection hole so duct work is easier and more flexible.
element. With the counter-flow element , air flows through the
element for a longer time (longer distance) ,so the heat-exchange
effect remains unchanged. Room air Supply air Room air
Inspection
cover
Reverse
Straight mounted
unit unit UTZ-BD025B UTZ-BD035B UTZ-BD050B UTZ-BD080B UTZ-BD100B
Inspection
A 810 978 1018 1250 1250
hatch
B 599 804 904 884 1134
C 315 580 640 428 678
D 142 112 132 228 228
Other element Fujitsu element E 600 600 600 600 600
(Cross-flow element) Exhaust air Outside air Exhaust air
(Counter-flow element) F 655 860 960 940 1190
G 19 19 19 19 19
Maintenance opening
H 270 317 317 388 388
Maintenance space I 135 159 159 194 194
J 159 182 182 218 218
K 882 1050 1090 1322 1322
Quiet operation L 414 470 470 612 612
M 95 70 127 85 85
Significantly reducing low pressure loss and noise allows low-noise N 219 162 210 258 258
operation. O 144 144 194 242 242
110 111
Ventilation
Wireless Simple Wired Wired Group Central Touch Panel System Controller
ARXH054GTAH ARXH072GTAH Remote Controller Remote Controller Remote Controller Remote Controller Remote Controller Remote Controller Controller System Controller Lite
(Touch Panel) (Software)
* The temperature setting is discharged air temperature setting. The air volume is set to a constant speed.
ARXH096GTAH
Specifications
Rated flow rate 1000 m3/h 1500 m3/h 2000 m3/h
Feature Model No. ARXH054GTAH ARXH072GTAH ARXH096GTAH
Power source Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz Single-phase, 230V, 50Hz
Capacity Cooling 14.0 22.4 28.0
kW
One VRF system can provide air conditioning and air supply at the same time. Heating 8.9 13.9 17.4
Input Power Cooling / Heating W 179 292 370
1
Outdoor Air Unit can be connected in a same VRF* system as one of Airflow Rate m3/h 1,080 1,680 2,100
indoor unit series and can create fresh and comfortable air supply VRF system Static Pressure Standard 185 200 200
together from our high advanced technology. Duct Pa
(range) (50-185) (50-200) (50-240)
*1. Connectable VRF series:J-IIS, J-II, V-II, V-II tropical, VR-II Sound Pressure Level dB(A) 42 44 47
In J-II series alone, OAU is prohibit to connect under Dimensions (H x W x D) mm 425×1,367×572 425×1,367×572 450×1,583×700
the ambient temperature off Indoor unit Indoor unit
40°C or higher. Weight kg 48 55 71
Fan Connection Pipe Diameter
mm Ø9.52 /Ø19.05 Ø12.70 / Ø22.22 Ø12.70 / Ø22.22
Heat (Small / Large)
Outdoor Air Unit Exchanger
Fresh Fresh Operation Cooling 5 to 43 5 to 43 5 to 43
Air Air ºCDB
Outdoor Air Range Heating -7 to 21 -7 to 21 -7 to 21
Unit
Refrigerant R410A R410A R410A
Wired R.C. Wired R.C. Wired R.C.
Note : Specifications are based on the following conditions.
* Make sure the connected capacity is within the range of 50% to 100% of the outdoor unit Cooling : Outdoor temperature of 33°CDB / 28°CWB.
capacity. In addition, if there are mixed connections with indoor units, make the Outdoor Heating : Outdoor temperature of 0°CDB / -2.9°CWB.
Air Unit connection capacity 30% or less of the outdoor unit capacity. Pipe length : 7.5 m Voltage : 230 [V].
High energy savings and flexible duct Top class compact design
design by using DC motor • Top class lightweight compact design at just 425 mm in height, 55 kg
in weight for ARXH072 type. This unit can be installed easily even at Dimensions (Unit : mm)
• Greatly reduces electricity
narrow space.
consumption by adopting
permanent magnet compared 1367 mm
to when using an AC motor.
054 / 072 type 096 type
respond flexibly to the external static pressure from 50 Pa to 240 Pa. (072 type) 425 1367 382
Main
425 1367 382 Main 450 8 1412(BOLT PITCH)
drain port
49
73
351 14 1192(BOLT PITCH) 231 351 14 1192(BOLT PITCH) 1251 151
29
drain port
Even if damper equipment is not used, static pressure can be 572 mm 181 1062 130 181 1062
146
36
28
146
120
28
Safety
655(BOLT PITCH)
adjusted and duct design is easy.
25
50
(ARXH072 type) drain
526(BOLT PITCH)
526(BOLT PITCH)
port
700
• Static pressure can be set easily using wired remote controller.
44
44
572
489
572
489
50
25
Safety Safety
39
39
drain port drain port
P150×7=1050 75
921 921 P160×2=320 15
50 to 240 Pa
1199 125
304 30 1247 111 304 30 1247 111 350 35 1454 111
(When external static (When external static
(096 type) Side view (L) Top view Side view (R) Side view (L) Top view Side view (R) Side view (L) Top view Side view (R)
pressure is small) pressure is large)
112 113
Ventilation
Arrangement as part of a VRF system [For 2EEV units connection (option)] 50% – 100% of outdoor unit capacity
AHU Thermistor
•Separation
• Separation Tube : UTP-LX180A
Transmission line
When connecting to an air handling unit, Indoor
unit Piping and wiring length
the supply air temperature is controlled
DX-Kit by the discharge sensor.
Air Handling Unit
EEV unit
VRF system
Air Handling
FCU Unit
When connecting to a fan coil unit, the Control unit
Max. wiring length 10 m
room temperature is controlled by the EEV unit
return air temperature sensor. DX-Kit
DX-Kit Thermistor Wired R.C.
Thermistor
Specifications
EEV unit UTP-VX30A UTP-VX60A UTP-VX90A UTP-VX90A×2
Supports a wide range of capacity classes A variety of controls to match the application Power source Single-phase, 230V, 50Hz
Connectable capacity class kW 5.0 6.3 8.0 10.0 12.5 14.0 20.0 25.0 40.0 50.0
• 2 EEV units can be connected in parallel and up to 20 HP (50 kW) • Central control using our VRF controllers or central management 5.6 6.3 8 10 12.5 14 22.4 25 40 50.4
large capacity units. (Separation Tube of UTP-LX180A is required.) controllers Cooling
(5.1-5.9) (6.0-7.1) (7.2-9.0) (9.1-11.1) (11.2-13.2) (13.3-18.0) (18.1-23.7) (23.8-28.0) (28.1-44.7) (44.8-50.4)
• Connectable capacity range: 5 kW to 50 kW Capacity kW
6.3 7.1 9 11.2 14 16 25 28 45 56.5
Heating
Transmission line (5.7-6.7) (6.8-8.0) (8.1-10.0) (10.1-12.4) (12.5-15.0) (15.1-20.0) (20.1-26.5) (26.6-31.5) (31.6-49.9) (50.0-56.5)
External I/O
Airflow Rate(Reference value) m3/h 1,060 1,200 1,520 1,600 2,000 2,240 3,560 4,000 6,400 8,000
EEV unit Interface Thermistor
(Option) Dimensions (H×W×D) mm 160 × 220 × 90 (160 × 220 × 90)× 2
DX-Kit
AHU or FCU Weight kg 2 2×2
VRF Controller Modbus network
Piping Connection pipe diameter(Liquid) mm Ø9.52 Ø12.70
(Future release)
EEV unit
AHU or FCU
(40 – 50 kW class)
• Central control from external controllers
EEV unit UTY-VDGX
Wiring Control unit
Thermistor Power source Single-phase, 230V, 50Hz
DDC* Dimensions (H×W×D) mm 400 × 400 × 120
External I/O 10
Transmission line Weight kg
DX-Kit AHU or FCU Note : Specifications are based on the following conditions.
3rd party Cooling : Indoor temperature of 27°CDB / 19°CWB, and outdoor temperature of 35°CDB / 24°CWB.
External I/O Controller *DDC=Direct Digital Controller Heating : Indoor temperature of 20°CDB / (15°CWB), and outdoor temperature of 7°CDB / 6°CWB.
Pipe length : 7.5 m Voltage : 230 [V].
114 115
Auto Louver Grille Kit (Option)
Models
UTD-GXTA-W Closed louver
UTD-GXTB-W
UTD-GXTC-W
Opened louver
Feature
AIRSTAGE
TM •Auto
Operation with indoor unit
Louver can be operated by synchronizing remote controller of
W2
Fitting Flame
indoor unit. Grille
• •UPAuto
and Down auto swing
airflow direction and auto swing
• 4 steps selectable
OPTION
•When
Auto-closing louver
operation of indoor unit is stopped, the louver will
H1 H2
automatically close.
W1 D1 D2
Auto Louver Grille
Duct type
Unit: mm
Model Name W1 W2 H1 H2 D1 D2
Specifications
Model name UTD-GXTA-W UTD-GXTB-W UTD-GXTC-W
Applicable Indoor Unit ARGD07/09/12/14GATH ARGD18GATH ARGD24GATH
ARGK07/09/12/14GCLH ARGK18GCLH ARGK24GCLH
ARGK07/09/12/14GALH ARGK18GALH ARGK24GALH
Power source Connecting with Control box of indoor unit
Fixing of Auto Louver Grille Screw Àxing to Flange or Square Duct
Extension Square Duct Limit 1.0m (Max. duct length between indoor unit and Grille)
Net Dimension mm 180x683x(84+9) 180 x 883 x (84+9) 180 x 1083 x (84+9)
(H x W x D) (inch) [7-3/32 x 26-7/8 x (3-5/16+11/32)] [7-3/32 x 34-3/4 x (3-5/16+11/32)] [7-3/32 x 42-5/8 x (3-5/16+11/32)]
Weight Net kg 2.0 (4.4) 2.5 (5.6) 3.0 (6.7)
Gross (lb.) 3.0 (6.7) 3.5 (7.8) 4.0 (8.9)
Color White
Louver Motor Stepping Motor
Accessories Fitting Flame, etc.
Operation °C (°F) 18 to 32 (64 to 90)
Cooling
Range % RH 80% or less
Heating °C (°F) 16 to 30 (60 to 88)
*: The Auto Louver Grille Kit can also be installed to ARXD07/09/12/14/18/24LATH revision code B models.
Please refer to the Design & Technical manual for ”revision code " details.
116 117
AIRSTAGE Option TM
Type AUGB AUGD AUGA ARGK ARGK ARGD ARGA ARGC ARGC ABGA ABGA ASGA ASGE ASGA Type AUGB AUGD AUGA ARGK ARGK ARGD ARGA ARGC ARGC ABGA ABGA ASGA ASGE ASGA
07/09/12/14/ 18/24 18/24/30/34/ 07/09/12/14/ 07/09/12/14/ 07/09/12/14/ 24/30/36/45 36/72/90 45/60/72/90 12/14/18/24 30/36/45/54 07/09/12/14 07/09/12/14 18/24/30 07/09/12/14/ 18/24 18/24/30/34/ 07/09/12/14/ 07/09/12/14/ 07/09/12/14/ 24/30/36/45 36/72/90 45/60/72/90 12/14/18/24 30/36/45/54 07/09/12/14 07/09/12/14 18/24/30
18/24GALH GALH 36/45/54GALH 18/24GCLH 18/24GALH 18/24GATH GBTH GBTH GATH GATH GATH GACH GACH GACH 18/24GALH GALH 36/45/54GALH 18/24GCLH 18/24GALH 18/24GATH GBTH GBTH GATH GATH GATH GACH GACH GACH
AUGB AUGD AUGA ARGC ASGA ASGA AUGB AUGD AUGA ARGC ASGA ASGA
07/09/12/14/ 18/24 30/36/45/54 96 07/09/12/14 18/24/30 07/09/12/14/ 18/24 30/36/45/54 96 07/09/12/14 18/24/30
18/24GATH GATH GATH GATH GATH GATH 18/24GATH GATH GATH GATH GATH GATH
Others
Controllers
z
IR Receiver z z
UTY-RNRGZ2
Unit UTY-LRHGB1 UTB-YWC
Wired
Remote
Controller
z
UTY-RLRG
Remote z
Sensor Unit New amenity space can be UTY-XSZX
offered by installing the
Simple Remote sensor.
z
Remote
Controller UTY-RSRG, UTY-RHRG, UTY-RSKG, UTY-RHKG
2-wire type 3-wire type z
UTG-
Wireless UFGD-W
z UTG-UFGD-W
Remote
UTY-LNHGU Cassette
Controller
Grille
z
Group
z UTG-UGGA-W
Remote
Controller UTY-CGGGU + UTY-VGGXZ1 UTG-UGGA-W
z
Central Auto
z UTD-GXTA-W
Remote Louver
Controller UTY-DCGG UTD-GXTB-W(18)
Grille Kit
UTD-GXTC-W(24)
Touch
z
Panel z
Controller UTY-DTGGZ1 Long Life z
Filter UTD-LF60KA
UTD-LF25NA
(36 / 45 / 60)
System
Controller,
z
System
Controller UTY-APGXZ1, UTY-ALGXZ1
Lite z
z
Flange UTD-SF045T
UTD-RF204
UTD-RF204
Interface
BACnet z
Gateway UTY-ABGXZ1, UTY-VBGX
z
Network
Convertor z UTZ-PX1NBA
for UTY-VLGX Drain
LONWORKS Pump
Unit
MODBUS z z
Convertor UTY-VMGX UTR-DPB24T
KNX z
Convertor UTY-VKGX (mm)
z
Panel
Spacer
242 UTG-BKXA-W
UTG-BGYA-W
z Panel spacer
KNX z z z
Interface FJ-RC-KNX-1i
FJ-RC-KNX-1i FJ-RC-KNX-1i FJ-RC-KNX-1i
(ARGC45/60/72/90/96GATH only)
Air Outlet For Compact Cassette
Shutter z z
Wireless z Plate
z z z UTR-YDZB UTR-YDZK
LAN FJ-RC-WIFI-1 For Cassette
Interface FJ-RC-WIFI-1 FJ-RC-WIFI-1 FJ-RC-WIFI-1
(ARGC45/60/72/90/96GATH only)
Insulation
External z z
Switch z for High
UTY-TERX Humidity UTZ-KXGC UTZ-KXRA
Controller For Compact Cassette type /
Cassette type
118 119
AIRSTAGE Option TM
OPTIONAL PARTS
Wired Remote Controller Wired Remote Controller Simple Remote Controller BACnet® Gateway Software BACnet® Gateway Hardware Network Convertor
(Touch Panel ) UTY-RLRG N E W UTY-RSRG N E W UTY-ABGXZ1 N E W UTY-VBGX for LONWORKS®
NEW UTY-RNRGZ2 With operation mode UTY-VLGX
WHITE-USB-KEY
(Software Protection Key)
Simple Remote Controller Wireless Remote Controller IR Receiver Unit UTY-VMGX NEW UTY-VKGX
N E W UTY-RHRG UTY-LNHGU UTB-YWC
Without operation mode
For All Duct types except Large Airflow Duct
IR Receiver Unit
UTY-LRHGB1
For Cassette type
Option
UTY-PTGXA
Panels
System Controller Lite Software System Controller Software
120 121
AIRSTAGE Option TM
OPTIONAL PARTS
Others
For Duct type Communication system: External Connect Kit
Flange (Round) Flange (Square) Remote Sensor Unit For Indoor unit For Outdoor unit
UTD-RF204 UTD-SF045T UTY-XSZX
UTY-XWZXZ7 UTY-XWZXZD UTY-XWZXZ6
For Medium Static Pressure Duct type / For Medium Static Pressure Duct type For All Duct type
Ceiling type
Long-Life Filter Auto Louver Grille Kit Drain Pump Unit For Central Remote Controller For Touch Panel Controller
UTD-LF25NA UTD-LF60KA UTD-GXTA-W (for ARGD07/09/12/14, ARGK07/09/12/14) UTZ-PX1NBA
UTD-GXTB-W (for ARGD18, ARGK18) UTY-XWZXZ7 UTY-XWZXZA
For Medium Static For High Static UTD-GXTC-W (for ARGD24, ARGK24) For Medium Static Pressure Duct type
Pressure Duct type Pressure Duct type
For Slim Duct type /
UTY-XWZXZ8
Mini Duct type
UTY-XWZXZA
Function
Input
Indoor unit Operation / Stop
950 z UTY-XWZXZB
Forced Stop
z UTY-XWZXZD
Air Outlet Shutter Plate Air Outlet Shutter Plate z UTY-XWZXZB
UTR-YDZB UTR-YDZK Emergency z UTY-XWZXZD z UTY-XWZXZ7 z *2
z UTY-XWZXZ6
Stop z UTY-XWZXZB z UTY-XWZXZ8 z *2
For Compact Cassette type For Cassette type
Forced z UTY-XWZXZE
Shuts the air outlet when only using as 3 blow out. Shuts the air outlet when only using as 3 blow out. Thermostat off z UTY-XWZXZ7
Low Noise
Mode Operation z UTY-XWZXZ6
Cooling/
Heating Priority z UTY-XWZXZ6
Outdoor Unit
Operation Peak z UTY-XWZXZ6
Control
Power Usage
z *2
Information from z UTY-XWZXZF
Electricity Meter z *2
For Ceiling type
Output
Auxiliary
Heater Output
z UTY-XWZXZC
*2: Touch Panel Controller has these functions for Dry contact and Apply voltage, however, above External Connect Kit is not necessary V-III Tropical : AJ½___LN½: AJG___LNL, AJH___LNT
because Touch Panel Controller has an external input terminal block. V-II Tropical : AJH___LN½AH½ : AJH___LNTAH, AJH___LNLAHU
OPTIONAL PARTS
Total cooling capacity of indoor unit (kW) 19.6 or less 28.0 or less 28.1 to 56.0 56.1 or more
Gas Pipe Liquid Pipe Gas Pipe Liquid Pipe
Header
3-6 Branches UTR-H0906L UTR-H1806L
Model name
3-8 Branches UTR-H0908L UTR-H1808L
UTP-AX180A UTP-AX567A Total cooling capacity of indoor unit (kW) 28.0 or less 28.1 to 56.0
2 outdoor units 1
Number of Outdoor unit
3 outdoor units 2
UTP-LX180A
For DX-Kit
EV Kit
Model name UTR-EV09XB UTR-EV14XB
ASGE07GACH ASGE12GACH
Application Model
ASGE09GACH ASGE14GACH
Header
124 125
ABOUT US
Since we began our air conditioning business in 1971,
our products have been popular around the world
and we continue to improve them.
OUR HISTORY
GLOBAL NETWORK
HIGH QUALITY DEVELOPMENT & PRODUCTION FACILITIES
PROJECT REFERENCE
126 127
About Us
For LARG
GE BUILDING
2001 2007 2009 2012 2013 2015 2016
10HP / Heat recovery & Heat pump 8 to 42HP / Heat pump High efficiency and Compact design model High efficiency and Compact design model Tropical spec model High efficiency and large capacity model. Tropical spec model
Extensive lineup from 8HP to 48HP 8 to 48HP / Heat Recovery Extensive lineup from 8HP to 42HP in 2HP Extensive lineup from 8HP to 54HP in Extensive lineup from 8HP to 54HP in 2HP
2003 in 2HP increment / Heat pump increment / Heat pump 2HP increment / Heat pump increment / Heat pump
10HP / Heat recovery 8,10HP / Heat pump
& Cooling
1936 Established
as Yaou Shouten Ltd. - 2016
2017
Certification Acquisition of New Product Initiatives RoHS Compliant DC Inverter Compressors
1936 Fujitsu introduced inverter technology Restriction of Hazardous Substances (ROHS) is Use of 100% inverter driven
Established as Yaou Shouten Ltd. which used R410A refrigerant. an EU directive on the restriction of the use of certain DC compressors.
hazardous substances in all consumer electrical and
1971 electronic equipment.
Air conditioner exports to Middle East.
128 129
About Us
GLOBAL NETWORK
Fujitsu General’s air conditioning business has acquired a major share of the overseas market.
We have many production and sales facilities overseas, and we continue to develop and sell products
that are accepted around the world by their “easy-to-use and environmentally-friendly technology”.
• Fujitsu General Air Conditioning (UK) Limited • Fujitsu General Central Air-conditioner (Wuxi) Co., Ltd.
• Fujitsu General (U.K.) Co., Limited
11
• Fujitsu General Do Brasil Ltda.
&
Overseas • Fujitsu General (Aust.)
FGA (Thailand) Co., Ltd.
6
• Fujitsu General
New Zealand
• Head Office
• Sales Companies
Overseas Limited
• Manufacturing Companies
Manufacturing Companies Fujitsu General (Thailand) Co., Ltd.
3
• R&D Center
• Fujitsu General Fujitsu General Engineering (Thailand) Co., Ltd.
(Asia) Pte. Ltd.
R&D Center
• Fujitsu General
(Middle East) FZE • Fujitsu General (Thailand) Co., Ltd.
• Fujitsu General Engineering (Thailand) Co., Ltd.
- R&D Center
• FGA (Thailand) Co., Ltd.
• TCFG Compressor (Thailand) Co., Ltd. TCFG Compressor (Thailand) Co.,Ltd.
130 131
About Us
ISO 9001
Reliability
Testing
High Product Quality Receiving inspections
Parts & Material
• Pressure resistance
Receiving inspection inspection
Parts procurement requires a supplier’s test • Primary leak
Transportation report. European regulation RoHS inspection is inspection • Assembly visual
inspection
also performed by special test department
& Handling in-house. Total number inspection is performed • Heat run inspection
• Secondary leak inspection
especially on main parts to remove defectives.
Testing Laboratory
Practical Test Room visual inspection
Shipping
132 133
About Us
PROJECT REFERENCE
Our product is popular because of its high quality, energy saving, and easy installation, and
so has been installed in a wide range of building types including high-rise office buildings,
stores, hotels, public facilities, schools, hospitals and residential.
Hotel in U.S.A.
134 135
SUPPORT
Our know-how supports you not only during the
product release but also from guiding implementation
to product maintenance.
AIRSTAGE™ SUPPORT
AIRSTAGE™ / RAC SUPPORT TOOL
QUICK SERVICE & MAINTENANCE
SERVICE TOOL
WEB MONITORING TOOL
Product news
Brochures
Operating Manual
Certificate Data
2D CAD Data
Installation Manual
Service Manual
CFD Simulation
Mobile Technician
Product Training
Model Selection
Design
Verification
Installation
136 137
Support
AIRSTAGE™ SUPPORT
Fujitsu General provides a variety of product and technical information to engineers and
consultants, and also conducts new product research and design support activities.
We provide a wide range of support to maintain high quality from design to installation.
Product information
New product information is provided in the form of documents
and movies for every new model released. These can be
downloaded from a private section of our website. To access this
website, please contact your Fujitsu representative.
Features
Head Office Training Center: Japan • Product News
• Brochures & All Manuals
• Feature Promotion Movie
Technical support
Technical support is provided at every stage from design to
Europe Training Center: Germany Europe Training Center: U.K. installation to assist in providing the most suitable air
conditioning solution.
Features
• CFD Simulation
• Guide line
• Commissioning Support 52.000
47,750
43.500
39.250
China Training Center: China Asia Training Center: Singapore CFD Simulation
35.000
America Training Center: U.S.A. Middle East Training Center: UAE Oceania Training Center: Australia
Commissioning Support
138 139
Support
Fujitsu General provides the Building Information Modeling (BIM) object models and contents for our VRF system and some products to the architect,
Automatically create designer and contractor using Autodesk® Revit® technology from our Website and Autodesk® Seek Website, etc.
model selection information
• Each unit can be automatically set by entering the required
performance, type, and temperature conditions for each indoor
unit and then dragging and dropping into the outdoor unit. 3D and 2D product data
• Piping and wiring diagrams can be created automatically and We provide 3D data that closely resemble the actual product
it is easy to set branches, grouping, and options. appearance. 2D CAD design operations are supported and 2D
• The additional refrigerant charging amount is automatically display is also provided. The data can also be output in other
calculated when the pipe length is entered. formats, such as DXF and DWG, which are used by other design
• It is also easy to set the remote controller groups, central CAD.
controller and converters.
• The equipment list including the equipment information is
created automatically.
Installation limitation
The equipment installation limitation range is shown.
Installation requirements, such as distance from the wall, is
automatically displayed to make it easy to produce highly
Output the format that reliable layout designs.
140 141
Support
Mobile troubleshooting tool for iPhone & Android Easy maintenance & monitoring
Unit number
Transmission line
• Operation status/control
We will release an App of troubleshooting tool for iPhone, iPod
• Monitoring operating condition
touch and other Apple products. This application is a trouble-
• Monitoring sensor data
shooting tool for Fujitsu General air conditioner (RAC/PAC, VRF)
• Indication of trend graph
• Error history
It helps you to check air conditioner condition. Error code check, Indoor unit
• Indication of refrigerant circuit diagram
Troubleshooting, and Sensor check are available.
• Automatic operation check for refrigeration cycle (Locally purchased)
Service Tool
USB adaptor UTY-ASGXZ1
(Locally purchased) Software
Remote monitoring
VRF system operating status and trouble status details can be
constantly and remotely monitored over the Internet, etc. Remote Monitoring
Rapid cooperation with the service personnel are also possible. Internet Web
or Monitoring
Public Telephone Tool
Line UTY-AMGXZ1
Software
142 143
Support
Transmission line
Whether each sensor value is normal is
Web Monitoring Tool
judged automatically.
Discharge temperature normal value OK
K
Super heat volume normal value OK Internet
High pressure pipe normal value OK
Low pressure pipe normal value OK
…etc. USB adapter
[Note] Use only as a guide and judge for yourself finally.
(Locally purchased)
Indoor unit
to support on site staff. USB adaptor (max. 4 adaptors per PC) permit, monitoring of up to
1,600 indoor units.
An error occurs at local system. Suitable for large-scale buildings or hotels.
Distant place
ERROR
VRF Network VRF Network VRF Network VRF Network
System 1 System 2 System 3 System 4
Internet Max. 400 Max. 400 Max. 400 Max. 400
Indoor unit Indoor unit Indoor unit Indoor unit
• Microsoft® Windows® 7 Professional (32-bit or 64-bit) SP1 • Microsoft® Windows® 7 Professional (32-bit or 64-bit) SP1
• Microsoft® Windows® 8.1 Pro (32-bit or 64-bit) • Microsoft® Windows® 8.1 Pro (32-bit or 64-bit)
Operating system Operating system
• Microsoft® Windows® 10 Pro (32-bit or 64-bit) • Microsoft® Windows® 10 Pro (32-bit or 64-bit)
CPU 1 GHz or higher CPU 1 GHz or higher
• 1 GB or more (for Windows Vista®, Windows® 7 [32-bit], Windows® 8.1 [32-bit], and Windows® 10 [32-bit]) • 1 GB or more (for Windows Vista®, Windows® 7 [32-bit], Windows® 8.1 [32-bit], and Windows® 10 [32-bit])
Memory Memory
• 2 GB or more (for Windows® 7 [64-bit], Windows® 8.1 [64-bit], and Windows® 10 [64-bit]) • 2 GB or more (for Windows® 7 [64-bit], Windows® 8.1 [64-bit], and Windows® 10 [64-bit])
HDD 40 GB or more of free space HDD 40 GB or more of free space
Display 1366 x 768 or higher resolution Display 1366 x 768 or higher resolution
• 2 USB ports • USB port (for 10 USB Network Interface Max.4, Software protection key)
Interface - 1 USB port is required for software protection key connection Interface • Either of the following interface is required for remote connection:
- 1 USB port is required for Echelon® U10 USB Network Interface - Internet using LAN: Ethernet port is required
Software Internet Explorer® 11 or Microsoft Edge / Adobe® Reader® 9.0 or later Software Internet Explorer® 11 or Microsoft Edge / Adobe® Reader® 9.0 or later
•Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.) •Echelon® U10 USB Network Interface – TP/FT-10 Channel (Model number: 75010R) (Required for each VRF Network.)
144 145
ISO 9001 ISO 14001 ISO 9001 ISO 14001 ISO 9001 ISO 14001
Certified number: 01 100 89394 Certified number: 01 104 9245/01 Certified number: 01 100 79269 Certified number: CNBJ311153-UK Certified number: 1591
14Q10065R4M
4 Certified number: 15912E10022R3M
Fujitsu General (Thailand) Co., Ltd. Fujitsu General (Shanghai) Co., Ltd. Fujitsu Gene
eral Central Air-conditioner (Wuxi) Co., Ltd.
“ ” is a worldwide trademark of FUJITSU GENERAL LIMITED and is a registered trademark in Japan and other countries or areas.
• Specifications and design are subject to change without notice for future improvement.
• For further details, please check with our authorised dealer.
• iPhone and iPad are trademarks of Apple Inc., registered in the U.S. and other countries.
• Other company and product names mentioned herein may be registered trademarks, trademarks or trade names of their respective owners.
• Actual products’ colors may be different from the colors shown in this printed material.