You are on page 1of 1

Footing PCC Footing Concrete Steel

L B L B h
F1 7'0" 5'0" 6'6" 4'6" 24" 12 Ø @ 6" C/C Both Way
F2 7'0" 5'0" 6'6" 4'6" 27" 12 Ø @ 5" C/C Both Way
F3 8'0" 6'0" 7'6" 5'6" 30" 12 Ø @ 4" C/C Both Way
CF1 9'0" 7'0" 8'6" 6'6" 21" 12 Ø @ 5" C/C Both Way
CF1 12'7" 9'2" 12'1" 9'8" 24" 12 Ø @ 5" C/C Both Way

STP ARRANGEMRNT
General Notes:- Column 24 Nos
1. SBC Assumed is 16 T/Sqm.
2. Column Links Shall be 8Ø Only.
3. Concrete Grade Shall be of M-25.
4. Footings & Columns are Designed for G+4 Only.
5. Grid Dimensions shall be Conformed at Site Only.
6. Footing Shall be Laid at Depth of 5'0" from BL or Rest on Firm Soil.
7. Clear Cover from Main Steel in Footing-2", Beam & Colunn-1", Slab-1/2".
8. Reinforcement Lap Shall be in Column 42D, Beam & Slab 52D.
9. Do Not Scale The Drawing Refer Written Dimensions Only.
10. Read This Drawing with Relevant Architectural Drawing if any Discrepancy
Shall be Brought to Our Notice Before Execution.

Column
Column Bars
Column Stps
3"

GL GL
B

H(6'0")

1'6" 1'6" h
3"
4"
L

Footing Cross Section Footing Details

Client:-
R Dimension:- (80' X 30') Consultant:-
E Foundation Details Asian Surveys & Consultants
Mr. Munni Laal V Date:- 21.06.2023
Proposed Residential Building Foundation Details Site Area:- 2400 Sft
(Survey, Architect & Project Managements)
E-mail:- omsingh512@gmail.com
Gatkanhalli, Bangalore. 0 Engineer:- O.P.Singh Ph:- 96864-42777