Professional Documents
Culture Documents
Manifold Application
®
ASTEC offers a variety range of 2, 3 & 5 Valve Instrument Manifold, which are designed for safety, reliability and positive LEAK TIGHT sealing of process
fluid, static Pressure and for differential pressure application in a wide range of Instrumentation. These Manifold gives the user greater flexibility, because
these offers a variety of simple configuration of easy Block, Bleed and Calibration of Differential Pressure Transmitter, Pressure Switch and Gauges.
2 valve Manifolds are designed for static Pressure and Liquid level applications. 3 & 5 Valve Manifold are designed for Differential Pressure applications.
®
The flow through ASTEC Manifold is controlled by a series of Stainless Steel Needle Valve. Each Valve has specific function to block the pressure, to
bleed off the pressure or to equalize the pressure, depending on its location on the Manifold.
Isolation Valve
e
alv
ISOLATE
45
62
in V
Dra
Drain Valve
DRAIN
Close Height 84
Open Height 95
Isolation Valve
ISOLATE
32
56
Open Height 118
Close Height 107
Straight type 1, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Suitable for wall mounting using two 1/4” bolts (not supplied)
Instrument
Model 2VMS2 ½" NPT(F)
51
Ø8.4 HOLE, 2NOS.
37 32
=
Mounting Hole
=
Isola
Isolation Valve
Drain Valve
ISOLATE
tion V
DRAIN
63.5
60
49
alve
Drain Port
1/4" NPT(F)
MAX OPEN - 177
MAX CLOSE - 155
Process
½" NPT(F)
Straight type 2, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Suitable for wall mounting using two 5/16” bolts (not supplied).
Instrument Valve 9
2-Valve Manifold
Model 2VMS3
Drain Valve
e
Valv
Drain
IN
D RA
DRAIN
14
25
Instrument
½” NPT(F)
Isolation Valve
alve
½” NPT(F)
54
Process
ISOLATE
tion V
60
Isola
28
63.5 MAX OPEN - 91
MAX CLOSE - 80
Straight type 3, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Comfort design require Pen Space mounting holes provided for ¼” bolts (not Supplied).
Model 2VMS4
alve
tionV
Isola
E
LAT
ISOLATE ISO
DRAIN
76
= 35 = 32 Drain port
1/4” NPT(F)
55
M10 x 1.5
MAX OPEN - 118 2 nos. Mounting hole.
MAX CLOSE - 107
Straight type 4, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.Left Hand side drain Bonnet, Compact design, can be used
in control panel & small enclosures. Base mounting holes are provided for M10 x 1.5 bolts (not supplied).
Model 2VMS5
Isolation Valve
alve
ti on V
Isola
A TE
ISOL
ISOLATE
MAX CLOSE - 131
MAX OPEN - 140
Drain
Drain Valve
Instrument
DRAIN
½” NPT(F)
Valve
76
½” NPT(F)
60
Process
10 35 M10 x 1.5, 32
2NOS.
55 Mounting Hole Drain port
1/4” NPT (F)
MAX OPEN - 118
MAX CLOSE - 107
Straight type 5, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Right hand side Bonnet, Compact design, can be used in
control Panel & Small enclosures. Base mounting holes are provided for M10 x 1.5 Bolts (not supplied).
Instrument Valve 10
2-Valve Manifold
Model 2VMS6
Instrument
1/4" NPT(F)
51
Drain Valve
Dra
DRAIN
in V
50
Isolation Valve
Iso
alve
latio
ISOLATE
nV
59
alv
e
Ø7, 1NO.
Mounting Hole
Drain Port
14 27 1/4" NPT(F) 25
Straight type 6, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Available with ¼” NPT(F) Thread, Compact design.
reduced in thread size, body size is also reduced. Mounting hole are provided for 1/4” bolts (not provided).
Model 2VMS7
Instrument
½" NPT(F)
51 32
Drain Port
1/4" NPT(F)
Isolation Valve
Isola
Drain
=
Drain Valve
ISOLATE
DRAIN
tion V
45
60
Valve
76
alve
=
8
Ø8.4, 2nos.,
Mounting
Hole MAX OPEN - 114 MAX OPEN - 95
MAX CLOSE - 103 MAX CLOSE - 84
Process
½" NPT(F)
Straight type 7, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Available with ½” NPT(F) Thread & Features a position of the Drain/ Test port. Mounting hole are provided for 5/16” bolts (not supplied).
Model 2VMS8
Instrument
½" NPT(F)
Drain Valve
Drain Valve
DRAIN
114
Isolation Valve
Isolation Valve
ISOLATE
Ø7.0, 2NOS,
ON 39 c/c,
MOUNTING
HOLE
32
51
MAX OPEN - 95
Process MAX CLOSE - 84
½" NPT(F) Drain Port
1/4" NPT(F)
Straight type 8, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Simple line Valve Isolation for comfort.
Available with mounting hole for 1/4” bolts (not supplied).
Instrument Valve 11
2-Valve Manifold
Model 2VMA
Instrument
½" NPT(F)
Drain Valve
e
alv
½" NPT(F)
Process
DRAIN
nV
45
62
latio
Iso
7 Drain Port
½" NPT(F)
Ø7, 2NOS.
Mounting
Hole
Isolation Valve
MAX CLOSE 84
ISOLATE
MAX OPEN 95
Drain Valve
DRAIN
32
55
Angle type, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Standard type Angle design of process and instrument connection with ½”NPT(F) port. Suitable for wall mounting using two 1/4” bolts (not supplied)
Model 2VME
Drain Valve
DRAIN DRAIN
Drain Port
1/4" NPT(F)
Instrument
½”NPT(F)
32
ISOLATE ISOLATE
Isolation Valve
100
Extended type, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Sleek design for easy valve operation.
Extended type. with ½”NPT(F) ports.
Instrument Valve 12
2-Valve Manifold
Model 2VMT1
Drain Valve
Isolation Valve
1/2”NPT(F)
Instrum ent
Process
Flange
Drain Port 46 18
1/4" NPT(F)
90 44.5
Ø12
Mounting Hole
Drain Valve
32
41.3
60
‘O’Ring
10 Seal
ISOLATE Instrument
Flange
Isolation Valve
Direct Mounting 1, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Two valve single flange block & bleed
or calibration manifold designed for direct mounting to Static pressure transmitter. Can be mounted to mounting bracket providing or safe isolation
valve of reducing No. of fitting & space for installation. Supplied with 7/16” bolts 2 nos and Teflon Seal- 1 nos.
Model 2VMT2
MAX OPEN - 149
MAX CLOSE - 138
86
54 c/c
Instrument
Flange ‘O' Ring
Seal
Drain Port
1/4" NPT(F)
18
Drain Valve
DRAIN
Drain Valve
77
63.5
Isolation Valve
ISOLATE
MAX OPEN - 95
Process MAX CLOSE - 84
Ø7 HOLE, 2Nos.
Mounting Hole ½" NPT(F)
Direct Mounting 2, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Two valve single flange block & bleed
manifold design for direct mounting to static pressure transmitter. Single ½”NPT(F) process connection with 1/4”NPT(F) test connection available.
Supplied with 7/16” bolts 4 nos and Teflon Seal- 1 nos.
Instrument Valve 13
2-Valve Manifold
Model 2VMT3
Isolation Valve
45 18
ISOLATE
Ø7, 2Nos.
Mounting Hole
Instrument
1/2”NPT(F)
Process
Flange
54 c/c
54 c/c
86
ISOLATE
Drain Port X 2 Nos.
Isolation Valve 1/4" NPT(F)
86
Isolation Valve
41.3
32
60
Ø12, 4Nos.
70 Instrument Mounting Hole
Flange For Transmitter
Direct Mounting 3, 2 Isolation, threaded on Process / Drain port and Flange on Instrument. This 2 way valve manifold is designed for liquid level
application mounted on pressure vessel consist of 2 isolation valve operating is parallel to shut-off any one of two process line. In this type equalize
passage is not provided. Manifold supplied with 4 nos. 7/16” bolts & Teflon seal 2 nos.
‘O’Ring Seal
Model 2VMT-CP1
Isolation Valve
Instrument
Drain Valve
Flange
41.30
ISOLATE
DRA IN
Ø12 x 2Nos.
Mounting Hole
For Transmitter
Isolation Valve
Isola
Drain Valve
ISOLATE
tion V
DRA IN
60
alve
Direct Mounting coplanar 1, 1 Isolation and 1 Drain Valve, threaded on Process / Drain and Flange on Instrument.
Coplanar & Direct mounting type compact design. Supplied with 7/16” bolts 2 nos and Teflon seal - 1 nos.
Model 2VMT-CP2
IsolationValve
alve
ti on V
Isola
TE
ISOLA
MAX CLOSE - 131
ISOLATE
MAX OPEN - 140
15
14
Drain Valve
½”NPT (F)
Instrument
41.3
DRAIN
Flange
Process
76
Ø12 x 2Nos.
Mounting Hole
9 For Transmitter
‘O’ Ring
10 16 Seal
32
Drain Port 26.5 Mounting Hole
1/4” NPT(F) M10 x 1.5
60
Direct Mounting coplanar 2, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Coplanar& Direct mounting
type manifold. Suitable for gauge transmitter or one cell of a differential pressure transmitter. Supplied with 7/16” bolts 2 nos and Teflon Seal- 1 nos.
Base mounting is provided with pin and mounting hole for M10x1.5 bolt (not supplied)
Instrument Valve 14
2-Valve Manifold
Ordering Information
S6 2 VMS1 IT G RT DP
Material Code
(select one)
Use Material Designator provided on page1.
IT ISOT (BSPT)
IP ISOP (BSP)
NC NACE - MR - 01 - 75
DP Drain Plug
Instrument Valve 15
3-valve Manifold
Instrument
88
Ø7, 2Nos.
Mounting Hole 20
Drain Port
1/4" NPT(F) X 2Nos.
d/p
Isolation Valve
Equaliser Valve
Isolation Valve
88
ISOLATE
EQUALIZE
ISOLATE
Equaliser Valve Isolation Valve
60
32
54 c/c
MAX OPEN 95
MAX OPEN 216 MAX CLOSE 84
MAX CLOSE 194
Process
½" NPT(F)
Separately mounted, 2 isolation and 1 equalizer valve, thread on process/instrument/Drain port. This Manifold is designed for Compact & limited
space installation, separately Mounted with 54 mm c/c inlet & outlet port connection. Application on line instrument calibration. Avoids in used of
numerous valve , nipple & fitting. Mounting holes are provided for 1/4” Bolts (not supplied).
10 25
d/p
15
7
Isolation Valve
Equaliser Valve
Isolation Valve
ISOLATE
EQUALIZE
ISOLATE
Isolation Valve
60
Equaliser Valve
57
54 MAX OPEN - 88
Separately Mounted, 2 Isolation 1 Equalizer threaded on Process / Instrument / Drain port . Designed for smaller threaded connection, as reduction
in overall dimension. Downstream 1/4” NPT(F) Test/Bleed connection are provided as Std with 2 nos. vent plug. The Std inlet & outlet connection
is 1/4” NPT (F) with c/c 54 mm. One mounting hole are provided for 1/4” bolts (not supplied).
½" NPT(F)x2Nos.
MAX OPEN - 140
d/p
Process
Side
Instrument
½”NPT(F)
76
½”NPT(F)
Process
54
30 32
Drain Port
110 1/4" NPT(F) x 2Nos
½" NPT(F) x 2Nos.
2 Nos. Mounting
142 Hole M10 x 1.5
Separately Mounted, 2 Isolation and 1 Equalizer valve, threaded on Process / Instrument / Drain port.
Designed to use on threaded outlet connection on 54 cm c/c to suit the inlet center connection of Instruments. Mounting holes are provided for
M10 X 1.5 bolts (not supplied).
Note : - 1) End Connection of different size can be provided on request.
2) Dimension in millimeter are for reference only and are subject to change
Instrument Valve 16
3-Valve Manifold
Model 3VMS-CP2
Equaliser Valve
Process
Instrument
Process
½”NPT(F)
½”NPT(F)
Test
Test
76
Option
Option
30 32
Upstream
Option
54
M10 x 1.5,
2 Nos.
110 Mounting Hole
142
Separately Mounted, 2 Isolation and 1 Equalize valve, threaded on Process / Instrument port.
Designed to use on threaded outlet connection on 54 cm c/c to suit the inlet center connection of instruments. Optional upstream or downstream
test port 1/4” NPT(F) are available. Mounting holes are provided for M10 X 1.5 bolts (not supplied).
Model 3VM-DBB
Instrument
½”NPT(F)
½”NPT(F)
Process
Drain Valve
1/4" NPT(F) in V
alv
e
DR
AIN
Ø7,2Nos.
Mounting Hole
55
28.0
Isolation Valve Isolation Valve Isolation Valve
60 25
Process 76
1/2”NPT(F)
Double Block and Bleed, with 2 Isolation and 1 Drain valve, threaded on Process, Instrument and Drain port. This Manifold is designed for critical
service for Isolation / Testing of Pressure Transmitter, Gauges, Switches, etc..Two isolating valves are to ensure total isolation of measuring
devices during maintenance. Due to the compact nature of block, it is popular for selection where space is at premium and connection are easy.
Mounting holes are provided for panel installation for 1/4” bolting (not supplied).
Instrument Valve 17
3-valve Manifold
Model 3VMT
Isolation Valve
45 18
ISOLATE
Ø7, 2Nos.
Mounting Hole
Instrument
½”NPT(F)
Eq
Process
54 c/c
54 c/c
Flange
al
88
is
er
V al
ve
d/p
ISOLATE
Drain Port
Isolation Valve 1/4" NPT(F) X 2Nos.
88
Equaliser Valve
‘O'Ring
MAX CLOSE 84
10 54 c/c
MAX OPEN 95
EQUALIZE Seal
Isolation Valve
41.3
32
60
Ø12, 4Nos.
77 Instrument Mounting Hole
Flange For Transmitter
Directly Mounted,2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. This 3 Valve, single flanged
manifold bolts directly to the differential pressure transmitter having 54 mm c/c connection with center line bolting features.
Supplied with 4 nos. 7/16” bolts and 2 nos.
Teflon seal.
Model 3VMT-CP1
Equaliser Valve
Drain Port
1/4" NPT(F) x 2Nos
Instrument
Side
30
142 M10 x 1.5, 2Nos.
Mounting Hole
Equaliser Valve
‘O’Ring
Seal
Process
Side
41.3
Instrument
½”NPT(F)
76
Process
Flange
54 32
110 Ø12, 4Nos.
Mounting Hole
½” NPT(F) x 2Nos. For Transmitter
142
Directly Mounted , 2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. This 3 Valve, Co planer manifold bolts
directly to the differential pressure transmitter having 54 mm c/c connection with center line bolting features. Supplied with 4 nos. 7/16” bolts
and 2 nos.Teflon seal. Base mounting holes are provided for M10 X 1.5 bolts (not supplied).
Instrument Valve 18
3- Valve Manifold
Model 3VMT-CP2
Equaliser Valve
Instrument
Side
d/p
30
Test
Test
142 Option
Option
Upstream
Isolation Valve Isolation Valve Option
ISOLATE
MAX CLOSE - 145
EQUALIZE ISOLATE
ISOLATE
MAX OPEN - 156
‘O'Ring
Seal
Process
Side
41. 3
½" NPT(F)
Process
76
Instrument
Flange
54 32
½"NPT(F) x 2Nos. 110
Ø12, 4Nos.
Mounting Hole
For Transmitter
Directly Mounted, 2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. Coplanar design suitable for direct
mounting to a differential pressure transmitter having a 54mm c/c connection with centerline bolting features. Optional upstream & downstream
Test port 1/4” NPT (F) are available. Manifolds are supplied with 2nos. Teflon seal & 4 nos. 7/16” bolt. Base mounting holes are provided for
M10 X 1.5 bolts (not supplied).
Model 3VMT-CP3
MAX OPEN - 234
MAX CLOSE - 212
108
Equaliser Valve
MAX CLOSE - 126
MAX OPEN - 136
EQUALIZE IZE
EQUAL
d/p
Process ‘O'Ring
Seal
Isolation Valve
Side
Isola
Isolation Valve
Instrument
½" NPT(F)
Process
ISOLATE
ISOLATE
tion V
60
Flange
42
76
a
lve
30
Ø12, 4Nos. 32
Mounting Hole M10 x 1.5, 2Nos.
For Transmitter 38 Mounting Hole
54
Directly Mounted Type, with 2 Isolation, 1 Equalizer threaded on Process / Drain / Flange on Instrument. Coplanar design with compact manifold for
direct mounting to a differential pressure transmitter having 54mm c/c connection with centerline bolting features. Supplied with 2 nos.
Teflon sealing ring & 4 nos. 7/16” bolts. Base mounting holes are provided for M10 X 1.5 bolts (not supplied).
Instrument Valve 19
3- Valve Manifold
Model 3VMH
Isolation Valve
61 18
ISOLATE
Ø7, 2Nos.
Mounting Hole
Instrument
Flange
ve
Process
Flange
54 c/c
V al
88
er
lis
ua
Eq
88 d/p
7/16" UNEF x 20TPI
54 c/c Mounting Hole , 4Nos.
ISOLATE
41.3 c/c
Isolation Valve
Drain Port
60
1/4" NPT(F)
Equaliser Valve
Process
‘O’Ring
MAX CLOSE 98
Flange
Seal
Process
Flange
Isolation Valve
Instrument
Ø12, 4Nos.
Flange
Mounting Hole
For Transmitter
97 Instrument
Flange ‘O'Ring
Seal
Directly Mounted, 2 Isolation and 1 Equalizer valve, threaded on Drain / Flange on both Process and Instrument.
Manifold suitable for direct mounting to a differential pressure transmitter having 54mm c/c connection with centerline bolting features. It also permits
the Transmitter Oval Flange to connect the Process line to the manifold directly with either ½”Pipe or Tubing connection.
Manifold are supplied with 4 nos. Teflon seal for Instrument & Process Flange.
Instrument Valve 20
3- Valve Manifold
Ordering Code
S6 3VMS1 IT G RT NC
Material Code
(select one)
Use Material Designator provided on page 1.
IT ISOT (BSPT)
IP ISOP (BSP)
NC NACE - MR - 01 - 75
DP Drain Plug
Instrument Valve 21
5-Valve ManiFold
Equaliser Valve
7
Dr
ain
EQUALIZE DRAIN d/p
Va
lve
Equaliser Valve
Instrument
½”NPT(F)
½”NPT(F)
Process
54 C/C
MAX CLOSE 84
88
20
MAX OPEN 95
Isolation Valve
lve
Va
ain
Dr
MAX CLOSE 194
MAX OPEN 216
88
Front View
ISOLATE
Ø7, 2 Nos.
Mounting Hole
Isolation Valve
Top View
Separately Mounted, 2 Isolation,1 Equalizer and 2 Instrument Drain Valve, threaded on Process / Instrument and Drain Port. Design for mounting
to a differential pressure transmitter where double bleed function is required having two vent / test port 1/4” NPT(F) for ease of venting and field
calibration of the Instrument.
Model 5VMS-2E
Isolation Valve
Drain Port
1/4" NPT(F), 2Nos.
ISOLATE
Drain Port
1/4" NPT(F) Drain Valve
7
MAX CLOSE 100
MAX OPEN 111
Equalizer Valve
Eq
ua
EQUALIZE
zli
DRAIN
er
Va
lv
Drain Valve
Instrument
½”NPT(F)
½”NPT(F)
54 C/C
MAX CLOSE 84
Process
88
20
MAX OPEN 95
d/p
e
Isolation Valve
alv
rV
lize
ua
Eq
MAX CLOSE 194
MAX OPEN 216
88
Front View
ISOLATE
Ø7, 2 Nos.
Mounting Hole
Isolation Valve
Top View
Separately Mounted, 2 Isolation,2 Equalizer and 1 Drain Valves, threaded on Process / Instrument and Drain Port. Design for mounting to a
differential pressure transmitter where as double equalizing function are required for metering system or for gas flow measurement.
Supplied with 2 nos. 1/4” NPT(F) vent plug. Mounting hole are provided for 1/4” bolt (not supplied)
Instrument Valve 22
5-Valve ManiFold
Model 5VMS-PD
Drain Valve
DRAIN
Equaliser Valve
7
Isolation Valve
d/p
EQUALIZE ISOLATE
Equaliser Valve
Instrument
½”NPT(F)
½”NPT(F)
Process
54 C/C
MAX CLOSE 84
20
88
MAX OPEN 95
Isolation Valve
Drain Valve
10
MAX CLOSE 192
MAX OPEN 214
88
Ø7, 2Nos.
Mounting Hole Front View Static Vent
DRAIN
1/4" NPT(F)
Drain Port with plug, 2Nos.
1/4" NPT(F) 2Nos.
Drain Valve
Top View
Separately Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument and Drain port. Design for
mounting to a differential pressure transmitter where as process drain function is required.
Model 5VMS-CP1
Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169
d/p
MAX CLOSE - 129
MAX OPEN - 140
Drain Valve
Drain Valve
Drain
½”NPT(F)
Instrument
½”NPT(F)
Process
DRAIN
DRAIN
Valve
76
30 32
54 Drain Port
75 1/4" NPT(F), 2Nos.
Front View
110 M10 x 1.5,
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246
Top View
Separately Mounted coplanar 1, 2 Isolation, 1 Equalizer and 2 Drain Valves for draining or test facilities, threaded on Process / Instrument
and Drain Port. Design for mounting to a differential pressure transmitter by including outlet threaded connection which are on c/c 54mm to suit
the inlet connection on the Instrument. Base mounting hole are provided for M10 x 1.5 bolts (not supplied).
Instrument Valve 23
5-Valve Manifold
Model 5 VMS-CP1-2E
Drain Valve
d/p
MAX CLOSE - 129
MAX OPEN - 140
Equaliser Valve
Equaliser Valve
Eq ua
EQUALIZE
Instrument
EQUALIZE
½”NPT(F)
½”NPT(F)
lis
Process
er Va
76
lve
30 32
54
Drain Port
75 1/4" NPT(F), 2Nos.
Separately Mounted coplanar 1, 2 Isolation,2 Equalizer and 1 Drain Valves, threaded on Process / Instrument and drain port.
Design for mounting to a differential pressure transmitter where as double equalizing function are required for metering system
or for gas flow measurement. Supplied with 2 Nos. 1/4” NPT plug. Base Mounting hole are Provided for M10 x 1.5 bolts (not supplied).
Model 5 VMS-CP1-PD
Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169
Drain Valve
Drain Valve
Drain
1/2" NPT(F)
Instrument
Process
1/2" NPT(F)
DRAIN
DRAIN
Valve
76
32
30
Drain Port
54 1/4" NPT(F), 2Nos.
75 M10 x 1.5,
110 2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246
Separately Mounted coplanar 1, 2 Isolation,1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument / Drain Port. Design for
mounting to a differential pressure transmitter where as process drain function is required. Base mounting hole are provided for M10 x 1.5 bolts
(not supplied).
Instrument Valve 24
5-Valve ManiFold
Model 5 VMS-CP2
Equaliser Valve
d/p
MAX CLOSE - 129
MAX OPEN - 140
Isolation Valve
Isolation Valve
lve
Instrument
½”NPT(F)
a
½”NPT(F)
ISOLATE
tion V
ISOLATE
Process
Isola
76
30
32
54
Drain Port
75
1/4" NPT(F), 2Nos.
110 M10 x 1.5,
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246
Separately Mounted coplanar 2, 2 Isolation,1 Equalizer and 2 Drain Valves, threaded on Process / Instrument/ Drain port. Design for
mounting to a differential pressure transmitter by Including outlet threaded connection which are on c/c 54mm to suit the inlet connection on the
instrument. Isolation valves are placed on left and right side of the body. Base mounting holes are provided for M10 x 1.5 bolts (not supplied).
Model 5 VMS-CP2-2E
Drain Valve
MAX CLOSE - 158
MAX OPEN - 169
d/p
MAX CLOSE - 129
MAX OPEN - 140
Isolation Valve
Isolation Valve
e
n Valv
ISOLATE
ISOLATE
Instrument
½”NPT(F)
½”NPT(F)
Process
o
Isolati
76
30
54 32
Drain Port
75 1/4" NPT(F), 2Nos.
Separately Mounted coplanar 2, 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Instrument/Drain port. Design for mounting
to a differential pressure transmitter where as double equalizing function are required for metering system or for gas flow measurement.
Isolation valve are placed on left and right side of the body. Base mounting are provided for M10x1.5 bolt(not supplied )
Instrument Valve 25
5-Valve Manifold
Model 5VMS-CP2-PD
Equaliser Valve
Isolation Valve
Isolation Valve
lve
on Va
Instrument
ISOLATE
ISOLATE
½”NPT(F)
½”NPT(F)
Process
ti
Isola
76
30 32
54 Drain Port
75
1/4" NPT(F), 2Nos.
Front View
M10 x 1.5,
110
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246
Top View
Separately Mounted coplanar 2, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument and Drain Port. Design for
mounting to a differential pressure transmitter where as process drain function is required. Provided with two mountinghole for M10 x 1.5 bolts
(not supplied).
Instrument Valve 26
5-Valve Manifold
Model 5 VMT
Instrument Instrument
Flange Flange
88
Ø12, 4Nos. 60
‘O'Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3
10
24
Drain Port
1/4" NPT(F), 18
2Nos.
d/p
Drain Valve
D
Isolation Valve
lve
ra
105
Isolation Valve
DRAIN
in
Va
Va
Is
in
lve
ol
ra
Equaliser Valve
D
at
ISOLATE
ISOLATE
io
EQUALIZE
n
Va
Equaliser Valve
lve
54 C/C MAX OPEN - 95
MAX CLOSE - 84
MAX OPEN - 214 MAX OPEN - 124
MAX CLOSE - 192 MAX CLOSE - 113
Process Process
1/2" NPT(F) 1/2" NPT(F)
Directly Mounted, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, threaded on Process / Drain Port / Flange on Instrument. These
five valves manifold bolts directly to the differential pressure transmitter having 54mm c/c connection with center line bolting features where
as required for double bleed functions and field callibration of the Instrument by test port. Provided with 2 nos. Teflon seal and 4 nos. 7/16”
bolts.
Model 5 VMT-2E
Instrument Instrument
Flange Flange
88 Ø12, 4Nos. 60
‘O'Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3 d/p
10
24
Static Vent
1/4" NPT(F)
18
ua
EQUALIZE
Isolation Valve
Va
Isolation Valve
105
lis
er
er
lis
Is
Va
ua
ol
lve
Drain Valve
ISOLATE
ISOLATE
Eq
at
io
n
DRAIN
Drain Valve
Va
lve
Directly Mounted with 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Drain Port / Flange on Instrument. Design for
bolting directly to the differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizer
function is required for metering system or for gas flow measurement. Supplied with 2 nos. 1/4” NPT drain plug, 2 nos. Teflon seal and
4 nos. 7/16” bolts.
Instrument Valve 27
5-Valve Manifold
Model 5 VMT-PD
d/p
Instrument Instrument
Flange Flange
88 Ø12, 4Nos. 60
‘O' Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3
10
24
Static Vent
1/4" NPT(F)
18
with plug, 2Nos.
Is
Isolation Valve
ol
lve
at
io
ISOLATE
Va
105
n
n
Va
Drain Valve
Drain Valve
tio lve
ola
lve
Equaliser Valve
DRAIN
Is
DRAIN
Va
in
EQUALIZE
ra
Equaliser Valve
D
54 C/C MAX OPEN - 95
MAX CLOSE - 84 Drain Port
MAX OPEN - 214 MAX OPEN - 124 1/4" NPT(F),
MAX CLOSE - 192 MAX CLOSE - 113 2Nos.
Process
1/2" NPT(F) Process
1/2" NPT(F)
Directly Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Flange on Instrument. Design for bolting
directly to differential pressure transmitter having 54mm c/c with center line bolting feature where as the process drain function is required.
supplied with 2 nos Teflon seals and 4 nos 7/16” bolts.
Model 5 VMT-CP1
Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169
d/p
MAX CLOSE - 129
MAX OPEN - 140
Drain Valve
Drain Valve
Drain
Instrument
Process
½”NPT(F)
41.3
DRAIN
DRAIN
Flange
Valve
76
30 32
Drain Port
Ø12, 4Nos. 54 1/4" NPT(F), 2Nos.
Mounting Hole
For Transmitter 75 M10 x 1.5,
110 2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246
Directly Mounted coplaner 1, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, threaded on Process / Drain port/Flange on Instrument.
Design for direct bolting to the differential pressure transmitter having 54mm c/c connection with center line bolting feature. Base mounting
hole are provided for M10 x 1.5 bolt (not supplied).Supplied with 2 nos Teflon seals and 4 nos 7/16” bolts.
Instrument Valve 28
5-Valve Manifold
Model 5 VMT-CP1-2E
Drain Valve
Equaliser Valve
Equaliser Valve
Equa
Instrument
Process
½”NPT(F)
EQUALIZE
EQUALIZE
41.3
liser
Flange
alveV
76
Static Vent 32
1/4" NPT(F)
with plug, 2Nos. 54 Drain Port
Ø12, 4Nos. 1/4" NPT(F)
Mounting Hole 110
For Transmitter
MAX OPEN - 268
MAX CLOSE - 246
Directly Mounted coplanar 2, 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Flange on Instrument. Design for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizing function
is required for metering system or gas flow measurement. supplied with 2 nos. Teflon seal and 4 nos. 7/16” bolts.
Model 5 VMT-CP1-PD
Equaliser Valve
d/p
MAX CLOSE - 158
Drain Valve
Drain Valve
Drain
Instrument
Process
½”NPT(F)
41.3
DRAIN
DRAIN
Flange
Valve
76
30 32
54 Drain Port
75 1/4" NPT(F), 2Nos.
Ø12, 4Nos.
Mounting Hole 110 M10 x 1.5,
For Transmitter 2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246
Directly Mounted coplaner, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Drain Port / Flange on Instrument.
Design suitable for direct mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as
process drain function is required supplied with 2 nos. Teflon seal and 4 nos. 7/16” bolt. Base mounting holes are provided for M10 x 1.5
bolt (not supplied).
Instrument Valve 29
5-Valve Manifold
Model 5 VMH
Instrument
Flange Instrument
Flange
88
41.3
54 ‘O’ Ring
Seal
Mounting Hole
For Transmitter
Drain Port
Ø12, 4Nos. .
1/4" NPT(F)
18
x 2Nos.
10
d/p
Drain Valve
D
lve
ra
89
DRAIN
in
Va
Va
in
Isolation Valve
lve
ra
Isolation Valve
Equaliser Valve
D
125
lve
ISOLATE
ISOLATE
EQUALIZE
Va
Equaliser Valve
n
io
7/16" UNEFx20TPI
10
Ø7, 2Nos.
Mounting Hole
41.3
54
‘O’Ring
60
Seal
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
MAX CLOSE - 98
Process
Flange MAX OPEN - 138
MAX CLOSE - 127
Directly Mounted, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, Flange on both Process and Instrument. Design suitable for
direct mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature it also permits the transmitter,
Oval Flange to connect the process line to the manifold directly with either ½”Pipe or Tube Connection. Supplied with 4nos. Teflon
seal for Instrument and Process Flange.
Model 5 VMH-2E
Instrument
Flange Instrument
Flange
88
41.3
54 ‘O'Ring
Seal
Mounting Hole
For Transmitter
Ø12, 4Nos. .
Drain Port
18
Drain Port
Equaliser Valve
Eq
ve
EQUALIZE
ua
al
89
lis
er
er
lis
Isolation Valve
V
ua
alv
Isolation Valve
Eq
Dra in Valve
125
e
lv e
ISOLATE
ISOLATE
Va
DRAIN
Drain Valve
io
at
7/16" UNEFx20TPI
10
Ø7, 2Nos.
Mounting Hole 41.3
54
‘O'Ring
Seal 60
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
MAX CLOSE - 98
Process
Flange MAX OPEN - 138
MAX CLOSE - 127
Directly Mounted, 2 Isolation, 2 Equalizer and 1 Drain Valves, Flange on both Process and Instrument. Design suitable for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizing function
is required for metering system or for gas flow measurement. It also permits the transmitter, Oval Flange to connect the process line to the
manifold directly with either ½”Pipe or Tube Connection. Supplied with 4 nos. Teflon seal for Instrument and Process Flange.
Instrument Valve 30
5-Valve Manifold
Model 5 VMH-PD
Instrument
Flange Instrument
Flange
88
41.3
54 ‘O'Ring
Seal
d/p
Drain Port
Mounting Hole
18
For Transmitter
1/4" NPT(F)
Ø12, 4Nos.
1/4" NPT(F)
x 2Nos.
10
Drain Port
Isolation Valve
lve
Is
ol
Va
ISOLATE
89
at
n
io
io
n
at
Va
ol
Drain Valve
Equaliser Valve
Drain Valve
lve
125
Is
lve
EQUALIZE
DRAIN
DRAIN
Va
Equaliser Valve
7/16" UNEFx20TPI
10
Ø7, 2Nos.
Mounting Hole 41.3
54
‘O'Ring 60
Seal
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
Process MAX CLOSE - 98
Flange MAX OPEN - 138
MAX CLOSE - 127
Directly Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, Flange on both Process and Instrument. Design suitable for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as process drain function
is required. It also permits the transmitter Oval Flange to connect the process line to the manifold directly with either
½” Pipe or Tube connection. Supplied with 4 nos. Teflon seal for Instrument and Process Flange.
Instrument Valve 31