2-Valve Manifold

Manifold Application
®
ASTEC offers a variety range of 2, 3 & 5 Valve Instrument Manifold, which are designed for safety, reliability and positive LEAK TIGHT sealing of process
fluid, static Pressure and for differential pressure application in a wide range of Instrumentation. These Manifold gives the user greater flexibility, because
these offers a variety of simple configuration of easy Block, Bleed and Calibration of Differential Pressure Transmitter, Pressure Switch and Gauges.
2 valve Manifolds are designed for static Pressure and Liquid level applications. 3 & 5 Valve Manifold are designed for Differential Pressure applications.
®
The flow through ASTEC Manifold is controlled by a series of Stainless Steel Needle Valve. Each Valve has specific function to block the pressure, to
bleed off the pressure or to equalize the pressure, depending on its location on the Manifold.

Seperately mounted Two Valve Manifold


2VMS - series

Ø7, 2NOS. Instrument


Mounting Hole ½" NPT(F)
Model 2VMS1

Isolation Valve
e
alv

ISOLATE
45
62

in V
Dra

Drain Port 7 Process


½" NPT(F) ½" NPT(F)

Drain Valve

DRAIN
Close Height 84
Open Height 95

Isolation Valve
ISOLATE
32

56
Open Height 118
Close Height 107

Straight type 1, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Suitable for wall mounting using two 1/4” bolts (not supplied)

Instrument
Model 2VMS2 ½" NPT(F)
51
Ø8.4 HOLE, 2NOS.
37 32
=
Mounting Hole
=
Isola
Isolation Valve
Drain Valve

ISOLATE

tion V
DRAIN

63.5
60

49

alve

Drain Port
1/4" NPT(F)
MAX OPEN - 177
MAX CLOSE - 155
Process
½" NPT(F)

Straight type 2, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Suitable for wall mounting using two 5/16” bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 9
2-Valve Manifold

Model 2VMS3

Drain Valve
e
Valv
Drain

IN
D RA
DRAIN

MAX CLOSE - 107


MAX OPEN - 118
Drain Port
1/4" NPT(F)
Ø7, 2NOS. 9 35

14

25
Instrument
½” NPT(F)

Isolation Valve
alve

½” NPT(F)
54

Process

ISOLATE
tion V

60
Isola
28
63.5 MAX OPEN - 91
MAX CLOSE - 80

Straight type 3, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Comfort design require Pen Space mounting holes provided for ¼” bolts (not Supplied).

Model 2VMS4
alve
tionV
Isola

E
LAT
ISOLATE ISO

MAX CLOSE - 131


MAX OPEN - 140
Drain Valve

DRAIN

76

= 35 = 32 Drain port
1/4” NPT(F)
55
M10 x 1.5
MAX OPEN - 118 2 nos. Mounting hole.
MAX CLOSE - 107

Straight type 4, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.Left Hand side drain Bonnet, Compact design, can be used
in control panel & small enclosures. Base mounting holes are provided for M10 x 1.5 bolts (not supplied).

Model 2VMS5
Isolation Valve

alve
ti on V
Isola

A TE
ISOL
ISOLATE
MAX CLOSE - 131
MAX OPEN - 140
Drain
Drain Valve

Instrument
DRAIN

½” NPT(F)
Valve

76
½” NPT(F)
60

Process

10 35 M10 x 1.5, 32
2NOS.
55 Mounting Hole Drain port
1/4” NPT (F)
MAX OPEN - 118
MAX CLOSE - 107

Straight type 5, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Right hand side Bonnet, Compact design, can be used in
control Panel & Small enclosures. Base mounting holes are provided for M10 x 1.5 Bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 10
2-Valve Manifold

Model 2VMS6

Instrument
1/4" NPT(F)
51

Drain Valve

Dra
DRAIN

in V
50

Isolation Valve
Iso

alve
latio

ISOLATE
nV
59

alv
e
Ø7, 1NO.
Mounting Hole

Drain Port
14 27 1/4" NPT(F) 25

MAX OPEN - 114 MAX OPEN - 88


MAX CLOSE - 104 MAX CLOSE - 78
Process
1/4" NPT(F)

Straight type 6, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Available with ¼” NPT(F) Thread, Compact design.
reduced in thread size, body size is also reduced. Mounting hole are provided for 1/4” bolts (not provided).

Model 2VMS7
Instrument
½" NPT(F)

51 32
Drain Port
1/4" NPT(F)
Isolation Valve

Isola
Drain
=

Drain Valve
ISOLATE

DRAIN

tion V
45

60
Valve

76
alve
=

8
Ø8.4, 2nos.,
Mounting
Hole MAX OPEN - 114 MAX OPEN - 95
MAX CLOSE - 103 MAX CLOSE - 84
Process
½" NPT(F)

Straight type 7, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Available with ½” NPT(F) Thread & Features a position of the Drain/ Test port. Mounting hole are provided for 5/16” bolts (not supplied).

Model 2VMS8
Instrument
½" NPT(F)
Drain Valve
Drain Valve

DRAIN

114
Isolation Valve

Isolation Valve

ISOLATE

Ø7.0, 2NOS,
ON 39 c/c,
MOUNTING
HOLE

32
51
MAX OPEN - 95
Process MAX CLOSE - 84
½" NPT(F) Drain Port
1/4" NPT(F)

Straight type 8, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Simple line Valve Isolation for comfort.
Available with mounting hole for 1/4” bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 11
2-Valve Manifold

Model 2VMA
Instrument
½" NPT(F)

Drain Valve
e
alv
½" NPT(F)
Process

DRAIN
nV
45
62

latio
Iso
7 Drain Port
½" NPT(F)
Ø7, 2NOS.
Mounting
Hole
Isolation Valve

MAX CLOSE 84
ISOLATE

MAX OPEN 95

Drain Valve
DRAIN
32
55

MAX OPEN 118


MAX CLOSE 107

Angle type, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port.
Standard type Angle design of process and instrument connection with ½”NPT(F) port. Suitable for wall mounting using two 1/4” bolts (not supplied)

Model 2VME
Drain Valve

DRAIN DRAIN
Drain Port
1/4" NPT(F)

Closed Height 138


Open Height 158
1/2”NPT(F)
Process

Instrument
½”NPT(F)

32

ISOLATE ISOLATE

Isolation Valve

100

Extended type, 1 Isolation and 1 Drain Valve, threaded on Process / Instrument / Drain port. Sleek design for easy valve operation.
Extended type. with ½”NPT(F) ports.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 12
2-Valve Manifold

Directly mounted Two Valve Manifold


2VMT - series

Model 2VMT1
Drain Valve

DRAIN Ø7, 2Nos.

Open Height 108


Close Height 97
Mounting Hole

Isolation Valve
1/2”NPT(F)

Instrum ent
Process

Flange
Drain Port 46 18
1/4" NPT(F)
90 44.5

Ø12
Mounting Hole
Drain Valve
32

41.3
60
‘O’Ring
10 Seal
ISOLATE Instrument
Flange

Isolation Valve

Direct Mounting 1, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Two valve single flange block & bleed
or calibration manifold designed for direct mounting to Static pressure transmitter. Can be mounted to mounting bracket providing or safe isolation
valve of reducing No. of fitting & space for installation. Supplied with 7/16” bolts 2 nos and Teflon Seal- 1 nos.

Model 2VMT2
MAX OPEN - 149
MAX CLOSE - 138
86

54 c/c

Instrument
Flange ‘O' Ring
Seal
Drain Port
1/4" NPT(F)
18

Drain Valve

DRAIN

Drain Valve
77
63.5
Isolation Valve

ISOLATE

MAX OPEN - 95
Process MAX CLOSE - 84
Ø7 HOLE, 2Nos.
Mounting Hole ½" NPT(F)

Direct Mounting 2, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Two valve single flange block & bleed
manifold design for direct mounting to static pressure transmitter. Single ½”NPT(F) process connection with 1/4”NPT(F) test connection available.
Supplied with 7/16” bolts 4 nos and Teflon Seal- 1 nos.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 13
2-Valve Manifold

Model 2VMT3
Isolation Valve
45 18
ISOLATE

Ø7, 2Nos.
Mounting Hole

MAX CLOSE 190


MAX OPEN 212

Instrument
1/2”NPT(F)
Process

Flange
54 c/c
54 c/c
86
ISOLATE
Drain Port X 2 Nos.
Isolation Valve 1/4" NPT(F)

86

10 54 c/c ‘O' Ring


Seal

Isolation Valve

41.3
32

60
Ø12, 4Nos.
70 Instrument Mounting Hole
Flange For Transmitter

Direct Mounting 3, 2 Isolation, threaded on Process / Drain port and Flange on Instrument. This 2 way valve manifold is designed for liquid level
application mounted on pressure vessel consist of 2 isolation valve operating is parallel to shut-off any one of two process line. In this type equalize
passage is not provided. Manifold supplied with 4 nos. 7/16” bolts & Teflon seal 2 nos.

‘O’Ring Seal

Model 2VMT-CP1

Isolation Valve
Instrument
Drain Valve

Flange
41.30

ISOLATE
DRA IN

Ø12 x 2Nos.
Mounting Hole
For Transmitter
Isolation Valve

Isola
Drain Valve

ISOLATE

tion V
DRA IN

60
alve

Drain Port 74 Process Port 32


1/4" NPT(F) ½" NPT(F)
MAX OPEN 200
MAX CLOSE 178

Direct Mounting coplanar 1, 1 Isolation and 1 Drain Valve, threaded on Process / Drain and Flange on Instrument.
Coplanar & Direct mounting type compact design. Supplied with 7/16” bolts 2 nos and Teflon seal - 1 nos.

Model 2VMT-CP2
IsolationValve

alve
ti on V
Isola

TE
ISOLA
MAX CLOSE - 131

ISOLATE
MAX OPEN - 140

15
14
Drain Valve

½”NPT (F)

Instrument
41.3
DRAIN

Flange
Process

76

Ø12 x 2Nos.
Mounting Hole
9 For Transmitter
‘O’ Ring
10 16 Seal
32
Drain Port 26.5 Mounting Hole
1/4” NPT(F) M10 x 1.5
60

MAX OPEN - 123


MAX CLOSE - 112

Direct Mounting coplanar 2, 1 Isolation and 1 Drain Valve, threaded on Process / Drain port and Flange on Instrument. Coplanar& Direct mounting
type manifold. Suitable for gauge transmitter or one cell of a differential pressure transmitter. Supplied with 7/16” bolts 2 nos and Teflon Seal- 1 nos.
Base mounting is provided with pin and mounting hole for M10x1.5 bolt (not supplied)

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 14
2-Valve Manifold

Ordering Information

S6 2 VMS1 IT G RT DP
Material Code
(select one)
Use Material Designator provided on page1.

Basic Model Number


Refer Dimensional Tables of required Product.

End Connection (select one)


Standard available NPT.

IT ISOT (BSPT)

IP ISOP (BSP)

SW Socket Weld Pipe

BW Butt Weld Pipe

Packing Material (select one)


Standard available is PTFE. Use G (Grafoil ®) for high temperatures

Tip Options (select one)


Standard Tip available is shut-off type. Use Code

RT for Regulating Tip

ST for Soft Tip (for Gas application)

Other Options (add one or more..)


ATI Anti Tamper Valve (Isolation)
OR
LI Locking Valve (Isolation)

ATD Anti Tamper Valve (Drain)


OR
LD Locking Valve (Drain)

NC NACE - MR - 01 - 75

MB Mounting Bolt & Nut (set of 2)

DP Drain Plug

Instrument Valve 15
3-valve Manifold

Seperately mounted Three Valve Manifold


3VMS - series

Instrument

Model 3VMS1 ½" NPT(F)

88
Ø7, 2Nos.
Mounting Hole 20
Drain Port
1/4" NPT(F) X 2Nos.

d/p

Isolation Valve

Equaliser Valve
Isolation Valve

88
ISOLATE

EQUALIZE
ISOLATE
Equaliser Valve Isolation Valve

60
32
54 c/c
MAX OPEN 95
MAX OPEN 216 MAX CLOSE 84
MAX CLOSE 194

Process
½" NPT(F)

Separately mounted, 2 isolation and 1 equalizer valve, thread on process/instrument/Drain port. This Manifold is designed for Compact & limited
space installation, separately Mounted with 54 mm c/c inlet & outlet port connection. Application on line instrument calibration. Avoids in used of
numerous valve , nipple & fitting. Mounting holes are provided for 1/4” Bolts (not supplied).

Model 3VMS2 Ø7, 1Nos.


Mounting
Hole Instrument
1/4" NPT(F)
Drain Port 1/4"NPT(F)
2Nos,, With Plug. 51

10 25

d/p
15
7

Isolation Valve

Equaliser Valve
Isolation Valve

ISOLATE

EQUALIZE
ISOLATE

Isolation Valve
60

Equaliser Valve

57
54 MAX OPEN - 88

102 MAX CLOSE - 77

MAX OPEN - 228


MAX CLOSE - 206
Process
1/4" NPT(F)

Separately Mounted, 2 Isolation 1 Equalizer threaded on Process / Instrument / Drain port . Designed for smaller threaded connection, as reduction
in overall dimension. Downstream 1/4” NPT(F) Test/Bleed connection are provided as Std with 2 nos. vent plug. The Std inlet & outlet connection
is 1/4” NPT (F) with c/c 54 mm. One mounting hole are provided for 1/4” bolts (not supplied).

Model 3VMS-CP1 Equaliser Valve

Isolation Valve Isolation Valve


MAX CLOSE - 145
MAX OPEN - 156

ISOLATE EQUALIZE ISOLATE


ISOLATE
MAX CLOSE - 129

½" NPT(F)x2Nos.
MAX OPEN - 140

d/p

Process
Side
Instrument
½”NPT(F)
76

½”NPT(F)
Process

54

30 32
Drain Port
110 1/4" NPT(F) x 2Nos
½" NPT(F) x 2Nos.
2 Nos. Mounting
142 Hole M10 x 1.5

Separately Mounted, 2 Isolation and 1 Equalizer valve, threaded on Process / Instrument / Drain port.
Designed to use on threaded outlet connection on 54 cm c/c to suit the inlet center connection of Instruments. Mounting holes are provided for
M10 X 1.5 bolts (not supplied).
Note : - 1) End Connection of different size can be provided on request.
2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 16
3-Valve Manifold

Model 3VMS-CP2
Equaliser Valve

MAX CLOSE - 157


MAX OPEN - 168
Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE ISOLATE


d/p

Process

MAX CLOSE - 128


MAX OPEN - 139
Side

Instrument
Process

½”NPT(F)
½”NPT(F)
Test
Test

76
Option
Option

30 32
Upstream
Option
54
M10 x 1.5,
2 Nos.
110 Mounting Hole
142

Separately Mounted, 2 Isolation and 1 Equalize valve, threaded on Process / Instrument port.
Designed to use on threaded outlet connection on 54 cm c/c to suit the inlet center connection of instruments. Optional upstream or downstream
test port 1/4” NPT(F) are available. Mounting holes are provided for M10 X 1.5 bolts (not supplied).

Model 3VM-DBB

Instrument
½”NPT(F)

½”NPT(F)
Process

Drain Port Dra

Drain Valve
1/4" NPT(F) in V
alv
e
DR
AIN

Ø7,2Nos.
Mounting Hole
55

28.0
Isolation Valve Isolation Valve Isolation Valve

60 25

Process 76
1/2”NPT(F)

Double Block and Bleed, with 2 Isolation and 1 Drain valve, threaded on Process, Instrument and Drain port. This Manifold is designed for critical
service for Isolation / Testing of Pressure Transmitter, Gauges, Switches, etc..Two isolating valves are to ensure total isolation of measuring
devices during maintenance. Due to the compact nature of block, it is popular for selection where space is at premium and connection are easy.
Mounting holes are provided for panel installation for 1/4” bolting (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 17
3-valve Manifold

Directly mounted Three Valve Manifold


3VMT - series

Model 3VMT
Isolation Valve
45 18
ISOLATE

Ø7, 2Nos.
Mounting Hole

MAX CLOSE 190


MAX OPEN 212

Instrument
½”NPT(F)

Eq
Process

54 c/c
54 c/c

Flange
al
88

is
er
V al
ve
d/p

ISOLATE
Drain Port
Isolation Valve 1/4" NPT(F) X 2Nos.

88
Equaliser Valve
‘O'Ring

MAX CLOSE 84
10 54 c/c

MAX OPEN 95
EQUALIZE Seal

Isolation Valve

41.3
32

60
Ø12, 4Nos.
77 Instrument Mounting Hole
Flange For Transmitter

Directly Mounted,2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. This 3 Valve, single flanged
manifold bolts directly to the differential pressure transmitter having 54 mm c/c connection with center line bolting features.
Supplied with 4 nos. 7/16” bolts and 2 nos.
Teflon seal.

Model 3VMT-CP1
Equaliser Valve

Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE

Drain Port
1/4" NPT(F) x 2Nos
Instrument
Side

30
142 M10 x 1.5, 2Nos.
Mounting Hole
Equaliser Valve

Isolation Valve Isolation Valve d/p


MAX CLOSE - 145
MAX OPEN - 156

ISOLATE EQUALIZE ISOLATE


ISOLATE
MAX CLOSE - 129
MAX OPEN - 140

‘O’Ring
Seal
Process
Side
41.3

Instrument
½”NPT(F)
76

Process

Flange

54 32
110 Ø12, 4Nos.
Mounting Hole
½” NPT(F) x 2Nos. For Transmitter
142

Directly Mounted , 2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. This 3 Valve, Co planer manifold bolts
directly to the differential pressure transmitter having 54 mm c/c connection with center line bolting features. Supplied with 4 nos. 7/16” bolts
and 2 nos.Teflon seal. Base mounting holes are provided for M10 X 1.5 bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 18
3- Valve Manifold

Model 3VMT-CP2
Equaliser Valve

Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE

Instrument
Side

d/p

30
Test
Test
142 Option
Option

M10 x 1.5, 2Nos.


Mounting Hole
Equaliser Valve

Upstream
Isolation Valve Isolation Valve Option

ISOLATE
MAX CLOSE - 145

EQUALIZE ISOLATE
ISOLATE
MAX OPEN - 156

MAX CLOSE - 129


MAX OPEN - 140

‘O'Ring
Seal
Process
Side

41. 3

½" NPT(F)
Process
76

Instrument
Flange
54 32
½"NPT(F) x 2Nos. 110
Ø12, 4Nos.
Mounting Hole
For Transmitter
Directly Mounted, 2 Isolation and 1 Equalizer valve, threaded on Process / Drain / Flange on Instrument. Coplanar design suitable for direct
mounting to a differential pressure transmitter having a 54mm c/c connection with centerline bolting features. Optional upstream & downstream
Test port 1/4” NPT (F) are available. Manifolds are supplied with 2nos. Teflon seal & 4 nos. 7/16” bolt. Base mounting holes are provided for
M10 X 1.5 bolts (not supplied).

Model 3VMT-CP3
MAX OPEN - 234
MAX CLOSE - 212
108

Equaliser Valve
MAX CLOSE - 126
MAX OPEN - 136

EQUALIZE IZE
EQUAL

d/p

Process ‘O'Ring
Seal
Isolation Valve

Side
Isola
Isolation Valve

Instrument
½" NPT(F)
Process
ISOLATE

ISOLATE

tion V
60

Flange
42

76
a
lve

30
Ø12, 4Nos. 32
Mounting Hole M10 x 1.5, 2Nos.
For Transmitter 38 Mounting Hole
54

Directly Mounted Type, with 2 Isolation, 1 Equalizer threaded on Process / Drain / Flange on Instrument. Coplanar design with compact manifold for
direct mounting to a differential pressure transmitter having 54mm c/c connection with centerline bolting features. Supplied with 2 nos.
Teflon sealing ring & 4 nos. 7/16” bolts. Base mounting holes are provided for M10 X 1.5 bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 19
3- Valve Manifold

Model 3VMH
Isolation Valve

61 18
ISOLATE

Ø7, 2Nos.
Mounting Hole

MAX CLOSE 190


MAX OPEN 212

Instrument
Flange
ve
Process
Flange

54 c/c
V al

88
er
lis
ua
Eq
88 d/p
7/16" UNEF x 20TPI
54 c/c Mounting Hole , 4Nos.

ISOLATE

41.3 c/c
Isolation Valve
Drain Port

60
1/4" NPT(F)
Equaliser Valve

Process
‘O’Ring

MAX OPEN 109


EQUALIZE

MAX CLOSE 98
Flange
Seal
Process
Flange

Isolation Valve

Instrument
Ø12, 4Nos.

Flange
Mounting Hole
For Transmitter

97 Instrument
Flange ‘O'Ring
Seal

Directly Mounted, 2 Isolation and 1 Equalizer valve, threaded on Drain / Flange on both Process and Instrument.
Manifold suitable for direct mounting to a differential pressure transmitter having 54mm c/c connection with centerline bolting features. It also permits
the Transmitter Oval Flange to connect the Process line to the manifold directly with either ½”Pipe or Tubing connection.
Manifold are supplied with 4 nos. Teflon seal for Instrument & Process Flange.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 20
3- Valve Manifold

Ordering Code

S6 3VMS1 IT G RT NC

Material Code
(select one)
Use Material Designator provided on page 1.

Basic Model Number


Refer Dimensional Tables of required Product.

End Connection (select one)


Standard available NPT, Not applicable for direct mounting Flange connections

IT ISOT (BSPT)

IP ISOP (BSP)

SW Socket Weld Pipe

Packing Material (select one)


Standard available is PTFE. Use G (Grafoil ®) for high temperatures

Tip Options (select one)


Standard Tip available is shut-off type. Use Code

RT for Regulating Tip

ST for Soft Tip (for Gas application)

Other Options (add one or more..)


ATI Anti Tamper Valve (both Isolation)
OR
LI Locking Valve ( both Isolation)

ATE Anti Tamper Valve (Equalizer)


OR
LE Locking Valve (Equalizer)

NC NACE - MR - 01 - 75

MB Mounting Bolt (set of 2)

DP Drain Plug

Instrument Valve 21
5-Valve ManiFold

Seperately mounted Five Valve ManiFold


5VMS - series
Purpose
Five Valve ManiFold are Design for Single and Double Equalizing function, for mounting to a Differential Pressure Transmitter providing Isolation,
Equalizing for zero adjustment of Instrument and drain for test or calibration.
For Double Equalizing, this ManiFold are used for the function of metering system or for the gas flow measurement.

Model 5VMS Isolation Valve


Drain Port
1/4" NPT(F), 2Nos.
ISOLATE

Equaliser Valve
7

MAX CLOSE 100


MAX OPEN 111
Drain Valve

Dr
ain
EQUALIZE DRAIN d/p

Va
lve
Equaliser Valve

Instrument
½”NPT(F)

½”NPT(F)
Process

54 C/C

MAX CLOSE 84
88
20

MAX OPEN 95

Isolation Valve
lve
Va
ain
Dr
MAX CLOSE 194
MAX OPEN 216

88

Front View
ISOLATE

Ø7, 2 Nos.
Mounting Hole
Isolation Valve

Top View

Separately Mounted, 2 Isolation,1 Equalizer and 2 Instrument Drain Valve, threaded on Process / Instrument and Drain Port. Design for mounting
to a differential pressure transmitter where double bleed function is required having two vent / test port 1/4” NPT(F) for ease of venting and field
calibration of the Instrument.

Model 5VMS-2E
Isolation Valve
Drain Port
1/4" NPT(F), 2Nos.
ISOLATE

Drain Port
1/4" NPT(F) Drain Valve
7
MAX CLOSE 100
MAX OPEN 111

Equalizer Valve
Eq
ua

EQUALIZE
zli

DRAIN
er
Va
lv
Drain Valve

Instrument
½”NPT(F)

½”NPT(F)
54 C/C

MAX CLOSE 84
Process

88
20

MAX OPEN 95

d/p
e

Isolation Valve
alv
rV
lize
ua
Eq
MAX CLOSE 194
MAX OPEN 216

88

Front View
ISOLATE
Ø7, 2 Nos.
Mounting Hole
Isolation Valve

Top View

Separately Mounted, 2 Isolation,2 Equalizer and 1 Drain Valves, threaded on Process / Instrument and Drain Port. Design for mounting to a
differential pressure transmitter where as double equalizing function are required for metering system or for gas flow measurement.
Supplied with 2 nos. 1/4” NPT(F) vent plug. Mounting hole are provided for 1/4” bolt (not supplied)

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 22
5-Valve ManiFold

Model 5VMS-PD
Drain Valve

DRAIN

Equaliser Valve
7

MAX CLOSE 100


MAX OPEN 111
Isolation Valve

Isolation Valve
d/p
EQUALIZE ISOLATE

Equaliser Valve

Instrument
½”NPT(F)

½”NPT(F)
Process

54 C/C

MAX CLOSE 84
20
88

MAX OPEN 95
Isolation Valve

Drain Valve

10
MAX CLOSE 192
MAX OPEN 214

88

Ø7, 2Nos.
Mounting Hole Front View Static Vent
DRAIN
1/4" NPT(F)
Drain Port with plug, 2Nos.
1/4" NPT(F) 2Nos.

Drain Valve

Top View

Separately Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument and Drain port. Design for
mounting to a differential pressure transmitter where as process drain function is required.

Model 5VMS-CP1

Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169

Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE ISOLATE

d/p
MAX CLOSE - 129
MAX OPEN - 140

Drain Valve

Drain Valve

Drain
½”NPT(F)

Instrument
½”NPT(F)
Process
DRAIN

DRAIN

Valve
76

30 32
54 Drain Port
75 1/4" NPT(F), 2Nos.
Front View
110 M10 x 1.5,
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246

Top View

Separately Mounted coplanar 1, 2 Isolation, 1 Equalizer and 2 Drain Valves for draining or test facilities, threaded on Process / Instrument
and Drain Port. Design for mounting to a differential pressure transmitter by including outlet threaded connection which are on c/c 54mm to suit
the inlet connection on the Instrument. Base mounting hole are provided for M10 x 1.5 bolts (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 23
5-Valve Manifold

Model 5 VMS-CP1-2E
Drain Valve

MAX CLOSE - 158


MAX OPEN - 169 Isolation Valve Isolation Valve

ISOLATE DRAIN ISOLATE


ISOLATE

d/p
MAX CLOSE - 129
MAX OPEN - 140

Equaliser Valve
Equaliser Valve

Eq ua
EQUALIZE

Instrument
EQUALIZE

½”NPT(F)

½”NPT(F)
lis
Process

er Va
76

lve
30 32
54
Drain Port
75 1/4" NPT(F), 2Nos.

110 M10 x 1.5,


2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246

Separately Mounted coplanar 1, 2 Isolation,2 Equalizer and 1 Drain Valves, threaded on Process / Instrument and drain port.
Design for mounting to a differential pressure transmitter where as double equalizing function are required for metering system
or for gas flow measurement. Supplied with 2 Nos. 1/4” NPT plug. Base Mounting hole are Provided for M10 x 1.5 bolts (not supplied).

Model 5 VMS-CP1-PD
Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169

Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE


ISOLATE d/p
MAX CLOSE - 129
MAX OPEN - 140

Drain Valve
Drain Valve

Drain
1/2" NPT(F)

Instrument
Process

1/2" NPT(F)
DRAIN
DRAIN

Valve
76

32
30
Drain Port
54 1/4" NPT(F), 2Nos.
75 M10 x 1.5,
110 2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246

Separately Mounted coplanar 1, 2 Isolation,1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument / Drain Port. Design for
mounting to a differential pressure transmitter where as process drain function is required. Base mounting hole are provided for M10 x 1.5 bolts
(not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 24
5-Valve ManiFold

Model 5 VMS-CP2

Equaliser Valve

MAX CLOSE - 158


MAX OPEN - 169

Drain Valve Drain Valve

DRAIN DRAIN DRAIN


EQUALIZE

d/p
MAX CLOSE - 129
MAX OPEN - 140

Isolation Valve

Isolation Valve

lve

Instrument
½”NPT(F)
a
½”NPT(F)
ISOLATE

tion V
ISOLATE

Process

Isola
76
30
32
54
Drain Port
75
1/4" NPT(F), 2Nos.
110 M10 x 1.5,
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246

Separately Mounted coplanar 2, 2 Isolation,1 Equalizer and 2 Drain Valves, threaded on Process / Instrument/ Drain port. Design for
mounting to a differential pressure transmitter by Including outlet threaded connection which are on c/c 54mm to suit the inlet connection on the
instrument. Isolation valves are placed on left and right side of the body. Base mounting holes are provided for M10 x 1.5 bolts (not supplied).

Model 5 VMS-CP2-2E

Drain Valve
MAX CLOSE - 158
MAX OPEN - 169

Equalizer Valve Equalizer Valve

EQUALIZE DRAIN EQUALIZE EQUALIZE

d/p
MAX CLOSE - 129
MAX OPEN - 140

Isolation Valve

Isolation Valve

e
n Valv
ISOLATE

ISOLATE

Instrument
½”NPT(F)

½”NPT(F)
Process

o
Isolati
76

30
54 32
Drain Port
75 1/4" NPT(F), 2Nos.

110 M10 x 1.5,


2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246

Separately Mounted coplanar 2, 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Instrument/Drain port. Design for mounting
to a differential pressure transmitter where as double equalizing function are required for metering system or for gas flow measurement.
Isolation valve are placed on left and right side of the body. Base mounting are provided for M10x1.5 bolt(not supplied )

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 25
5-Valve Manifold

Model 5VMS-CP2-PD

Equaliser Valve

MAX CLOSE - 158


MAX OPEN - 169
d/p
Drain Valve Drain Valve

DRAIN EQUALIZE DRAIN DRAIN

MAX CLOSE - 129


MAX OPEN - 140

Isolation Valve

Isolation Valve

lve
on Va

Instrument
ISOLATE
ISOLATE

½”NPT(F)

½”NPT(F)
Process

ti
Isola
76
30 32
54 Drain Port
75
1/4" NPT(F), 2Nos.
Front View
M10 x 1.5,
110
2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246

Top View

Separately Mounted coplanar 2, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Instrument and Drain Port. Design for
mounting to a differential pressure transmitter where as process drain function is required. Provided with two mountinghole for M10 x 1.5 bolts
(not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 26
5-Valve Manifold

Directly Mounted Five Valve Manifold


5VMT - series

Model 5 VMT

Instrument Instrument
Flange Flange
88
Ø12, 4Nos. 60
‘O'Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3

10
24
Drain Port
1/4" NPT(F), 18
2Nos.

d/p

Drain Valve
D

Isolation Valve
lve

ra

105
Isolation Valve

DRAIN
in
Va

Va

Is
in

lve

ol
ra

Equaliser Valve
D

at
ISOLATE
ISOLATE

io
EQUALIZE

n
Va
Equaliser Valve

lve
54 C/C MAX OPEN - 95
MAX CLOSE - 84
MAX OPEN - 214 MAX OPEN - 124
MAX CLOSE - 192 MAX CLOSE - 113
Process Process
1/2" NPT(F) 1/2" NPT(F)

Top View Front View

Directly Mounted, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, threaded on Process / Drain Port / Flange on Instrument. These
five valves manifold bolts directly to the differential pressure transmitter having 54mm c/c connection with center line bolting features where
as required for double bleed functions and field callibration of the Instrument by test port. Provided with 2 nos. Teflon seal and 4 nos. 7/16”
bolts.

Model 5 VMT-2E

Instrument Instrument
Flange Flange
88 Ø12, 4Nos. 60
‘O'Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3 d/p
10

24
Static Vent
1/4" NPT(F)
18

with plug, 2Nos.


E qualiser Valve
Eq
lve

ua

EQUALIZE
Isolation Valve
Va
Isolation Valve

105
lis
er

er
lis

Is
Va
ua

ol
lve

Drain Valve
ISOLATE
ISOLATE

Eq

at
io
n
DRAIN

Drain Valve
Va
lve

54 C/C MAX OPEN - 95


MAX CLOSE - 84
MAX OPEN - 214 MAX OPEN - 124
MAX CLOSE - 192 MAX CLOSE - 113 Drain Port
Process 1/4" NPT(F),
Process 1/2" NPT(F)
1/2" NPT(F)

Top View Front View

Directly Mounted with 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Drain Port / Flange on Instrument. Design for
bolting directly to the differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizer
function is required for metering system or for gas flow measurement. Supplied with 2 nos. 1/4” NPT drain plug, 2 nos. Teflon seal and
4 nos. 7/16” bolts.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 27
5-Valve Manifold

Model 5 VMT-PD

d/p
Instrument Instrument
Flange Flange
88 Ø12, 4Nos. 60
‘O' Ring 54 Ø7, 2Nos. Mounting Hole
Seal Mounting Hole For Transmitter 41.3

10
24
Static Vent
1/4" NPT(F)

18
with plug, 2Nos.

Is

Isolation Valve
ol

lve
at
io

ISOLATE
Va

105
n

n
Va
Drain Valve

Drain Valve
tio lve
ola

lve
Equaliser Valve
DRAIN

Is

DRAIN

Va
in
EQUALIZE

ra
Equaliser Valve

D
54 C/C MAX OPEN - 95
MAX CLOSE - 84 Drain Port
MAX OPEN - 214 MAX OPEN - 124 1/4" NPT(F),
MAX CLOSE - 192 MAX CLOSE - 113 2Nos.

Process
1/2" NPT(F) Process
1/2" NPT(F)

Directly Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Flange on Instrument. Design for bolting
directly to differential pressure transmitter having 54mm c/c with center line bolting feature where as the process drain function is required.
supplied with 2 nos Teflon seals and 4 nos 7/16” bolts.

Model 5 VMT-CP1
Equaliser Valve
MAX CLOSE - 158
MAX OPEN - 169

Isolation Valve Isolation Valve

ISOLATE EQUALIZE ISOLATE


‘O’ Ring E
ISOLAT
Seal

d/p
MAX CLOSE - 129
MAX OPEN - 140

Drain Valve
Drain Valve

Drain

Instrument
Process
½”NPT(F)
41.3

DRAIN
DRAIN

Flange
Valve
76

30 32
Drain Port
Ø12, 4Nos. 54 1/4" NPT(F), 2Nos.
Mounting Hole
For Transmitter 75 M10 x 1.5,
110 2 Nos.
Mounting Hole
MAX OPEN - 268
MAX CLOSE - 246

Directly Mounted coplaner 1, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, threaded on Process / Drain port/Flange on Instrument.
Design for direct bolting to the differential pressure transmitter having 54mm c/c connection with center line bolting feature. Base mounting
hole are provided for M10 x 1.5 bolt (not supplied).Supplied with 2 nos Teflon seals and 4 nos 7/16” bolts.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 28
5-Valve Manifold

Model 5 VMT-CP1-2E

Drain Valve

MAX CLOSE - 158


MAX OPEN - 169
d/p
Isolation Valve Isolation Valve

ISOLATE DRAIN ISOLATE ‘O’Ring ISOLATE


Seal
MAX CLOSE - 129
MAX OPEN - 140

Equaliser Valve
Equaliser Valve

Equa

Instrument
Process
½”NPT(F)
EQUALIZE
EQUALIZE

41.3

liser

Flange
alveV
76
Static Vent 32
1/4" NPT(F)
with plug, 2Nos. 54 Drain Port
Ø12, 4Nos. 1/4" NPT(F)
Mounting Hole 110
For Transmitter
MAX OPEN - 268
MAX CLOSE - 246

Directly Mounted coplanar 2, 2 Isolation, 2 Equalizer and 1 Drain Valves, threaded on Process / Flange on Instrument. Design for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizing function
is required for metering system or gas flow measurement. supplied with 2 nos. Teflon seal and 4 nos. 7/16” bolts.

Model 5 VMT-CP1-PD

Equaliser Valve
d/p
MAX CLOSE - 158

Isolation Valve Isolation Valve


‘O’Ring
ISOLATE EQUALIZE ISOLATE Seal ISOLATE
MAX CLOSE - 129
MAX OPEN - 140

Drain Valve
Drain Valve

Drain

Instrument
Process
½”NPT(F)
41.3
DRAIN

DRAIN

Flange
Valve
76

30 32
54 Drain Port
75 1/4" NPT(F), 2Nos.
Ø12, 4Nos.
Mounting Hole 110 M10 x 1.5,
For Transmitter 2 Nos.
MAX OPEN - 268 Mounting Hole
MAX CLOSE - 246

Directly Mounted coplaner, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, threaded on Process / Drain Port / Flange on Instrument.
Design suitable for direct mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as
process drain function is required supplied with 2 nos. Teflon seal and 4 nos. 7/16” bolt. Base mounting holes are provided for M10 x 1.5
bolt (not supplied).

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 29
5-Valve Manifold

Model 5 VMH

Instrument
Flange Instrument
Flange
88
41.3
54 ‘O’ Ring
Seal

Mounting Hole
For Transmitter
Drain Port

Ø12, 4Nos. .
1/4" NPT(F)

18
x 2Nos.

10
d/p

Drain Valve
D
lve

ra
89

DRAIN
in
Va

Va
in

Isolation Valve
lve
ra
Isolation Valve

Equaliser Valve
D

125
lve
ISOLATE
ISOLATE

EQUALIZE

Va
Equaliser Valve

n
io

Mounting Hole x 4Nos..


at
ol
Is

7/16" UNEFx20TPI
10
Ø7, 2Nos.
Mounting Hole
41.3
54
‘O’Ring
60
Seal
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
MAX CLOSE - 98
Process
Flange MAX OPEN - 138
MAX CLOSE - 127

Directly Mounted, 2 Isolation, 1 Equalizer and 2 Instrument Drain Valves, Flange on both Process and Instrument. Design suitable for
direct mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature it also permits the transmitter,
Oval Flange to connect the process line to the manifold directly with either ½”Pipe or Tube Connection. Supplied with 4nos. Teflon
seal for Instrument and Process Flange.

Model 5 VMH-2E
Instrument
Flange Instrument
Flange
88
41.3
54 ‘O'Ring
Seal
Mounting Hole
For Transmitter
Ø12, 4Nos. .

Drain Port
18

1/4" NPT(F) d/p


x 2Nos.
1/4" NPT(F)
10

Drain Port
Equaliser Valve
Eq
ve

EQUALIZE
ua
al
89

lis
er

er
lis

Isolation Valve
V
ua

alv
Isolation Valve

Eq

Dra in Valve

125
e

lv e
ISOLATE
ISOLATE

Va
DRAIN

Drain Valve
io
at

Mounting Hole x 4Nos..


ol
Is

7/16" UNEFx20TPI
10

Ø7, 2Nos.
Mounting Hole 41.3
54
‘O'Ring
Seal 60
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
MAX CLOSE - 98
Process
Flange MAX OPEN - 138
MAX CLOSE - 127

Directly Mounted, 2 Isolation, 2 Equalizer and 1 Drain Valves, Flange on both Process and Instrument. Design suitable for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as double equalizing function
is required for metering system or for gas flow measurement. It also permits the transmitter, Oval Flange to connect the process line to the
manifold directly with either ½”Pipe or Tube Connection. Supplied with 4 nos. Teflon seal for Instrument and Process Flange.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 30
5-Valve Manifold

Model 5 VMH-PD

Instrument
Flange Instrument
Flange
88
41.3
54 ‘O'Ring
Seal
d/p
Drain Port

Mounting Hole
18

For Transmitter
1/4" NPT(F)

Ø12, 4Nos.
1/4" NPT(F)
x 2Nos.

10

Drain Port
Isolation Valve
lve

Is
ol
Va

ISOLATE
89

at
n

io
io

n
at

Va
ol

Drain Valve

Equaliser Valve
Drain Valve

lve

125
Is

lve
EQUALIZE
DRAIN

DRAIN

Va
Equaliser Valve

Mounting Hole x 4Nos.


ai
Dr

7/16" UNEFx20TPI
10
Ø7, 2Nos.
Mounting Hole 41.3
54
‘O'Ring 60
Seal
Process
MAX OPEN - 212 Flange
MAX CLOSE - 190 MAX OPEN - 109
Process MAX CLOSE - 98
Flange MAX OPEN - 138
MAX CLOSE - 127

Directly Mounted, 2 Isolation, 1 Equalizer and 2 Process Drain Valves, Flange on both Process and Instrument. Design suitable for direct
mounting to differential pressure transmitter having 54mm c/c connection with center line bolting feature where as process drain function
is required. It also permits the transmitter Oval Flange to connect the process line to the manifold directly with either
½” Pipe or Tube connection. Supplied with 4 nos. Teflon seal for Instrument and Process Flange.

Note : - 1) End Connection of different size can be provided on request.


2) Dimension in millimeter are for reference only and are subject to change

Instrument Valve 31

You might also like