HU DONG & ZHONGHUA SHIPBUILDING (GROUP) CO.,LTD. PROJECT NO. DWG. NO.

9000700S
H1786A-H1787A
( ) SHEET 143

36.VACUUM PUMPS

1. GENERAL
A. Particular
· Maker : MAPRO
· Type : Sliding rotary vane vaccum pump P100 Sv type
· Performance data :

2. Procedure of test and confirmation item


In order to ensure satisfactory operation, various tests and checks to be carried out carefully.
A. Prior to the commissioning, following works to be checked.
a) Check whether the unit is suitably linked, and alignment between motor and vacuum pump.
b) Check the oil level (Front End Cover of pump).
c) Check the electric parts.
d) Check the fresh water system.
e) Check the Suction & Discharge line.
B. Safety device test
Check the safety device test (trip or alarms) shown on following pages
C.Running test
Before running test, following item to be confirmed.
a) Vacuum pump alignment
b) Rotation of driving motor
c) Installation condition of coupling and bulkhead seal
d) Fresh water system

CHECK LIST FOR No.1 VACUUM PUMP


A. Safety Device Test
HU DONG & ZHONGHUA SHIPBUILDING (GROUP) CO.,LTD. PROJECT NO. DWG. NO. 9000700S
H1786A-H1787A
( ) SHEET 144

No. Check item(Setting Point) Result Remark

2 Suction Temp Low (-55 )


3 Discharge Temp High (190 )
4 Cooling Water Out Flow Low(0.5m3/h)
5 Common Suction Press Low (-800mBar)
6 Motor High Temp(130 )
7 Low level for L.O oil TK(210mm)

How to test
1)
2) Disconnect the electric cable from the suction temperature switch.
3) Disconnect the electric cable from the discharge temperature switch.
4) Disconnect the electric cable from the cooling water flow switch.
5) Disconnect the electric cable from the pressure switch.
6) Disconnect the electric cable from motor.
7) Disconnect the electric cable from level switch.

B. Running Test

Check item Setting Value 10 Min 20 Min 30 Min


Inlet pressure kPa
Outlet pressure kPa
Inlet temperature
Outlet temperature
Cool. water inlet temperature
(portable gauge)
Cool. water outlet temperature
Cool. water inlet pressure kPa
Normal/
Oil level condition
Abnormal
Motor temp.(portable gauge)

CHECK LIST FOR No.2 VACUUM PUMP


A. Safety Device Test

No. Check item(Setting Point) Result Remark

2 Suction Temp Low (-55 )


3 Discharge Temp High (190 )
4 Cooling Water Out Flow Low(0.5m3/h)
5 Common Suction Press Low (-800mBar)
6 Motor High Temp(130 )
7 Low level for L.O oil TK(210mm)