You are on page 1of 49

N330-17.

75/540/540 CONDENSING STEAM TURBINE

PERFORMANCE DESIGN DATA

N17AS25.RTE

Beijing BEIZHONG Steam Turbine Generator Co.,Ltd

July 2012
N330-17.75/540/540
Beijing BEIZHONG Steam
Turbine Generator Co.,Ltd N17AS25.RTE
Condensing Steam Turbine
3 1

CONTENTS

1—Calculation of through flow


1) The technical data sheets of typical operating conditions ·················· 1~3

2) Calculation of through flow of typical operating conditions ·············· 4~5

2—Gland sealing steam system


1) Gland sealing steam system sketch map ·············································· 6

2) The gland leak-off flow (HP front) curves ············································ 7

3) The gland leak-off flow (HP rear) curves ············································· 8

4) The gland leak-off flow (IP front) curves ············································· 9

5) The gland leak-off flow (IP rear) curves············································· 10

6) The gland leak-off flow (LP rear) curves ············································ 11

3—Calculation of steam distributing


1) Calculation of steam distributing (governing stage data) ···················· 12

4—Calculation of heat balance


1) The thermal process graph of(TMCR) ·············································· 13

2) The thermal process graph of (VWO) ··············································· 14

3) Heat balance diagrams ······························································· 15~25

Derived From Prepared 王博 20120720 Authorized


Checked 吴向云 20120720
Verified 任蕾 20120721
Std. Exam. Date
Approved
Mark Number Document No. Signature Date Duty Signature
Beijing BEIZHONG Steam N330-17.75/540/540 N17AS25.RTE
Turbine Generator Co.,Ltd Condensing Steam Turbine 3 2

—Characteristic curves
5—
1) HP governing valve opening - STG output curve·································26

2) Main steam mass flow - STG output curve ·········································27

3) Heat rate - STG output curve ····························································28

4) Steam rate - STG output curve ··························································29

5) Final feed water temperature-STG output curve·································30

6) Cylinder efficiency - STG output curves ·············································31

7) Pressure after governing stage - STG output curve ·····························32

8) Pressure at extraction point - STG output curves (1) ···························33

9) Pressure at extraction point - STG output curves (2) ···························34

10) Condenser back pressure variation - STG output variation curve·······35

11) Mechanical and electric loss - STG output curve ·······························36

—Calculation of steam velocity


6—
1) Calculation of steam velocity (1) ························································37

2) Calculation of steam velocity (2) ························································38

—Characteristic/Performance data and curves


7—
1) Main steam temperature correction curves ········································39

2) Main steam pressure correction curves ··············································40

3) Reheat steam temperature correction curves ······································41

4) Reheat steam pressure drop correction curves ····································42

5) Condenser back pressure correction curves ········································43

6) Exhaust volume flow-Exhaust loss curve ············································44

7) Exhaust volume flow-LP casing efficiency curve ·································45


Beijing BEIZHONG Steam N330-17.75/540/540 N17AS25.RTE
Turbine Generator Co.,Ltd Condensing Steam Turbine 3 3

EXPLANATION OF ABBREVIATION:
(1): HP——High Pressure (cylinder)
(2): IP——Intermediate Pressure (cylinder)
(3): LP——Low Pressure (cylinder)
(4): HPH——High Pressure feed-water Heater
(5): LPH——Low Pressure feed-water Heater
(6): DE——Deaerator
(7): H.E. ——High pressure cylinder Exhaust
(8): GSH——Gland Steam Heater
(9): STG——Steam Turbine Generator
(10): FP——Feed-water Pump
(11): DP——Drain Pump
(12): CP——Circulating water Pump
(13): CW——Circulating Water
(14): T——Temperature
(15): X——Dryness
(16): CW temp——Circulating Water temperature
(17): SPO——Sliding Pressure Operation
(18): THO——The HPHs out of service condition
N17AS25.RTE
The technical data sheets of typical operating conditions
45 1

The technical data sheets of typical operating conditions (1)

VWO VWO* TMCR TMCR*

STG output kW 346369 344599 330092 330322

Main steam pressure MPa(a) 17.75 17.75 17.75 17.75

Main steam temperature ℃ 540 540 540 540

Main steam mass flow t/h 1028 1028 972 979

Reheat steam pressure MPa(a) 4.1473 4.1302 3.9322 3.9438

Reheat steam temperature ℃ 540 540 540 540

Reheat steam mass flow t/h 931.95 929.17 882.76 886.33

Back pressure MPa(a) 0.0095 0.0095 0.0095 0.0095

Exhaust dryness / 0.9127 0.9128 0.9153 0.9151

Exhaust mass flow t/h 692.00 682.34 659.62 654.62

Calculated Heat Rate kJ/kW.h 7958.7 8002.1 7970.7 8013.5

Calculated steam rate kg/ kW.h 2.9679 2.9832 2.9446 2.9638

HP efficiency / 0.8350 0.8350 0.8284 0.8279

IP efficiency / 0.9153 0.9155 0.9154 0.9156

LP efficiency / 0.8943 0.8947 0.8965 0.8966

Internal efficiency / 0.9000 0.9002 0.8988 0.8988

Final feed-water temperature ℃ 259.66 259.41 256.44 256.62

Boiler blow down % 0 3 0 3

—boiler blowdown 3%(make up 3%)


Note: the operating conditions marked with “ * ”—
N17AS25.RTE
The technical data sheets of typical operating conditions
45 2

The technical data sheets of typical operating conditions (2)


80%
80% 60% 50%
TMCR
TMCR TMCR TMCR
(SPO)
STG output kW 264080 198121 165279 264136

Main steam pressure MPa(a) 17.75 17.75 17.75 14.906

Main steam temperature ℃ 540 540 540 540

Main steam mass flow t/h 769 576 488 773

Reheat steam pressure MPa(a) 3.1495 2.3891 2.0369 3.1663

Reheat steam temperature ℃ 540 540 540 540

Reheat steam mass flow t/h 703.59 531.12 451.89 707.91

Back pressure MPa(a) 0.0095 0.0095 0.0095 0.0095

Exhaust dryness / 0.9294 0.9492 0.9618 0.9291

Exhaust mass flow t/h 539.16 418.84 361.99 541.40

Calculated Heat Rate kJ/kW.h 8132.8 8399.7 8642.2 8162.3

Calculated steam rate kg/ kW.h 2.9120 2.9073 2.9526 2.9265

HP efficiency / 0.7697 0.7114 0.6572 0.8139

IP efficiency / 0.9096 0.9023 0.8965 0.9096

LP efficiency / 0.8974 0.8878 0.8778 0.8974

Internal efficiency / 0.8801 0.8533 0.8282 0.8935

Final feed-water temperature ℃ 243.46 228.14 219.72 243.83

Boiler blow down % 0 0 0 0


N17AS25.RTE
The technical data sheets of typical operating conditions
45 3

The technical data sheets of typical operating conditions (3)


60% 50%
TMCR TMCR THO
(SPO) (SPO)
STG output kW 198296 165086 330552

Main steam pressure MPa(a) 11.376 9.611 17.75

Main steam temperature ℃ 540 540 540

Main steam mass flow t/h 586 494 892

Reheat steam pressure MPa(a) 2.4325 2.0647 4.0409

Reheat steam temperature ℃ 540 540 540

Reheat steam mass flow t/h 541.50 458.56 887.52

Back pressure MPa(a) 0.0095 0.0095 0.0095

Exhaust dryness / 0.9481 0.9609 0.9154

Exhaust mass flow t/h 425.21 365.81 696.04

Calculated Heat Rate kJ/kW.h 8488.0 8729.7 8216.3

Calculated steam rate kg/ kW.h 2.9552 2.9924 2.6985

HP efficiency / 0.7990 0.7872 0.8034

IP efficiency / 0.9023 0.8965 0.9110

LP efficiency / 0.8883 0.8783 0.8930

Internal efficiency / 0.8840 0.8755 0.8905

Final feed-water temperature ℃ 229.27 220.64 187.20

Boiler blow down % 0 0 0


N17AS25.RTE
Calculation of through flow of VWO
45 4

(VWO: Main steam mass flow - 1028 t/h, Condenser pressure - 0.0095 MPa(a))

specific
steam pressure temp degree isentropic
stage volume velocity stage
mass after after of enthalpy
after ratio efficiency
flow stage(N0) stage(N0) reaction drop
N0 stage(N0)

t/h MPa(a) ℃ m3/kg / / kJ/kg /


1 1027.76 14.7105 512.71 0.0218 / 0.4360 51.007 0.7970
2 1021.28 13.4703 499.06 0.0234 0.2727 0.5398 27.988 0.7912
3 1021.28 12.3634 485.67 0.0251 0.2834 0.5538 26.820 0.8266
4 1021.28 11.2650 471.31 0.0271 0.2380 0.5385 28.632 0.8356
5 1021.28 10.2038 456.26 0.0294 0.2491 0.5403 29.915 0.8412
6 1021.28 9.0964 439.17 0.0322 0.1747 0.5207 34.050 0.8427
7 1021.28 8.0373 421.19 0.0357 0.1955 0.5199 35.895 0.8451
8 1021.28 7.0341 402.36 0.0397 0.1861 0.5210 37.754 0.8446
9 1021.28 6.1320 383.32 0.0444 0.1945 0.5236 37.916 0.8597
10 1021.28 5.3238 364.22 0.0499 0.2122 0.5267 38.046 0.8663
11 1021.28 4.6081 345.72 0.0560 0.2395 0.5328 37.798 0.8717
12 931.90 3.6859 525.40 0.0973 0.2756 0.5636 35.386 0.8006
13 930.16 3.3256 509.53 0.1057 0.2619 0.5779 36.486 0.8730
14 930.16 2.9748 492.16 0.1156 0.2497 0.5849 38.730 0.9014
15 930.16 2.6276 473.11 0.1277 0.2533 0.5833 42.097 0.9054
16 930.16 2.2872 452.22 0.1426 0.2643 0.5809 45.794 0.9121
17 876.97 1.9738 430.58 0.1604 0.2594 0.5939 47.244 0.9121
18 876.97 1.6703 406.87 0.1833 0.2480 0.5907 51.820 0.9078
19 876.97 1.3872 381.20 0.2125 0.2453 0.5946 55.615 0.9129
20 876.97 1.1240 353.17 0.2512 0.2789 0.5918 60.517 0.9119
21 831.44 0.8972 324.03 0.3003 0.2685 0.6098 61.942 0.9230
22 831.44 0.6947 292.22 0.3673 0.2998 0.6111 66.901 0.9291
23 831.44 0.5324 260.67 0.4528 0.3279 0.6318 65.827 0.9318
24/29 386.19 0.2855 198.86 0.7441 0.2220 0.5339 136.195 0.8696
25/30 386.19 0.1465 136.39 1.2549 0.3568 0.5622 131.653 0.9053
26/31 373.83 0.0750 X=0.9891 2.1852 0.3843 0.6459 114.857 0.9314
27/32 359.07 0.0306 X=0.9507 4.8635 0.5907 0.6532 139.708 0.8977
28/33 345.69 0.0095 X=0.9102 13.9045 0.5640 0.7031 163.498 0.8516
X——Dryness
N17AS25.RTE
Calculation of through flow of TMCR
45 5

(TMCR: Main steam mass flow - 972 t/h, Condenser pressure - 0.0095 MPa(a))

specific
steam pressure temp degree isentropic
stage volume velocity stage
mass after after of enthalpy
after ratio efficiency
flow stage(N0) stage(N0) reaction drop
N0 stage(N0)

t/h MPa(a) ℃ m3/kg / / kJ/kg /


1 971.76 13.8747 504.84 0.0230 / 0.3730 69.503 0.7480
2 965.62 12.7077 491.37 0.0246 0.2735 0.5426 27.706 0.7913
3 965.62 11.6661 478.16 0.0264 0.2850 0.5567 26.545 0.8266
4 965.62 10.6310 463.97 0.0285 0.2392 0.5409 28.376 0.8356
5 965.62 9.6316 449.12 0.0309 0.2499 0.5429 29.628 0.8413
6 965.62 8.5891 432.26 0.0339 0.1759 0.5233 33.703 0.8429
7 965.62 7.5923 414.53 0.0375 0.1972 0.5227 35.510 0.8452
8 965.62 6.6482 395.98 0.0418 0.1880 0.5240 37.331 0.8447
9 965.62 5.8002 377.24 0.0467 0.1959 0.5270 37.429 0.8600
10 965.62 5.0407 358.45 0.0523 0.2147 0.5304 37.516 0.8665
11 965.62 4.3691 340.31 0.0587 0.2414 0.5371 37.202 0.8720
12 882.72 3.4952 525.47 0.1027 0.2759 0.5635 35.394 0.8005
13 881.06 3.1543 509.66 0.1116 0.2616 0.5781 36.470 0.8731
14 881.06 2.8222 492.33 0.1221 0.2493 0.5849 38.727 0.9014
15 881.06 2.4936 473.37 0.1348 0.2526 0.5836 42.056 0.9054
16 881.06 2.1714 452.54 0.1505 0.2649 0.5811 45.753 0.9121
17 831.67 1.8740 430.94 0.1693 0.2591 0.5935 47.313 0.9119
18 831.67 1.5861 407.26 0.1934 0.2479 0.5904 51.874 0.9079
19 831.67 1.3176 381.63 0.2242 0.2452 0.5944 55.647 0.9129
20 831.67 1.0680 353.66 0.2649 0.2788 0.5918 60.517 0.9119
21 789.17 0.8527 324.54 0.3166 0.2683 0.6094 62.026 0.9230
22 789.17 0.6604 292.74 0.3871 0.2997 0.6108 66.956 0.9292
23 789.17 0.5063 261.22 0.4770 0.3279 0.6317 65.836 0.9319
24/29 366.95 0.2715 199.37 0.7839 0.2216 0.5334 136.456 0.8696
25/30 366.95 0.1393 136.82 1.3221 0.3566 0.5617 131.911 0.9053
26/31 355.34 0.0713 X=0.9906 2.2955 0.3814 0.6454 115.030 0.9321
27/32 341.49 0.0291 X=0.9523 5.0983 0.5897 0.6546 139.093 0.8990
28/33 329.50 0.0095 X=0.9130 13.9549 0.5463 0.7176 156.931 0.8579
X——Dryness
Gland sealing steam system sketch map
High Pressure cylinder Intermediate Pressure cylinder Low Pressure cylinder

after governing stage

Atmosphere
Atmosphere
Atmosphere

Atmosphere
Atmosphere
2nd extraction
Atmosphere

IP front

LP rear
IP rear
HP rear
4 3 2 1 1 2 3 4 5 5 4 3 2 1 1 2 3 3 2 1 1 2 3

to LPH 4 to LPH 1

GSH
condensing water

N17AS25.RTE
45
two HP main stop value
four HP governing value

6
N17AS25.RTE
The gland leak-off高压缸前汽封漏汽量曲线
flow (HP front) curves

漏汽量(t/h)
45 7
7

6
The gland leak-off flow (HP front) curves
5
Steam flow of leak-off (t/h)

7.00

4
6.00

3
5.00

2
4.00

1
3.00
0
100 300 500 700 900 1100
2.00
总漏汽量 漏到高排汽量 进汽量(t/h)
漏入DJ4汽量 供自密封汽量
1.00

0.00
400 500 600 700 800 900 1000 1100
The total To H.E Main steam mass flow (t/h)
To LPH4 Sealing steam
To GSH

The gland leak-off flow (HP front) data


Main steam The total To H.E. To LPH4 Sealing To GSH
mass flow steam
t/h t/h t/h t/h t/h t/h
1028 6.4819 4.6068 1.5035 0.3254 0.0462
972 6.1342 4.3495 1.4308 0.3075 0.0464
718 4.5513 3.1935 1.0893 0.2215 0.0471
488 3.1035 2.1592 0.7635 0.1334 0.0475
442 2.8117 1.9536 0.6966 0.1140 0.0475
N17AS25.RTE
The gland leak-off flow (HP rear) curves
45 8

The gland leak-off flow (HP rear) curves


Steam flow of leak-off (t/h)

3.00

2.50

2.00

1.50

1.00

0.50

0.00
400 500 600 700 800 900 1000 1100

The total To LPH4 Main steam mass flow (t/h)


Sealing steam To GSH

The gland leak-off flow (HP rear) data


Main steam The total To LPH4 Sealing To GSH
mass flow steam
t/h t/h t/h t/h t/h
1028 2.4621 1.9938 0.4073 0.0610
972 2.3422 1.8952 0.3857 0.0612
718 1.7730 1.4203 0.2908 0.0618
488 1.2256 0.9894 0.1742 0.0620
442 1.1124 0.9018 0.1487 0.0619
N17AS25.RTE
The gland leak-off flow (IP front) curves
45 9

The gland leak-off flow (IP front) curves


Steam flow of leak-off (t/h)

2.00

1.80

1.60

1.40

1.20

1.00

0.80

0.60

0.40

0.20

0.00
400 500 600 700 800 900 1000 1100
The total From the 16th stage Main steam mass flow (t/h)
To LPH4 Sealing steam
To GSH

The gland leak-off flow (IP front) data


Main steam The total From the To LPH4 Sealing To GSH
mass flow 16th stage steam
t/h t/h t/h t/h t/h t/h
1028 1.7488 0.4478 1.8747 0.2526 0.0694
972 1.656 0.4277 1.7786 0.2358 0.0693
718 1.2344 0.3313 1.3382 0.1584 0.0691
488 0.8474 0.2369 0.9327 0.0827 0.0689
442 0.7692 0.2169 0.8508 0.0664 0.0689
N17AS25.RTE
The gland leak-off flow (IP rear) curves
45 10

The gland leak-off flow (IP rear) curves


Steam flow of leak-off (t/h)

0.45

0.40

0.35

0.30

0.25

0.20

0.15

0.10

0.05

0.00
400 500 600 700 800 900 1000 1100

The total Sealing steam To GSH Main steam mass flow (t/h)

The gland leak-off flow (IP rear) data


Main steam The total Sealing To GSH
mass flow steam
t/h t/h t/h t/h
1028 0.4063 0.3217 0.0845
972 0.3850 0.3005 0.0845
718 0.2859 0.2020 0.0839
488 0.1896 0.1063 0.0832
442 0.1690 0.0859 0.0831
N17AS25.RTE
The gland leak-off flow (LP rear) curves
45 11

The gland leak-off flow (LP rear) curves


Steam flow of leak-off (t/h)

0.60

0.50

0.40

0.30

0.20

0.10

0.00
400 500 600 700 800 900 1000 1100

To LP cylinder Sealing steam To GSH Main steam mass flow (t/h)

The gland leak-off flow (LP rear) data


Main steam To LP Sealing To GSH
mass flow cylinder steam
t/h t/h t/h t/h
1028 0.3065 0.5593 0.2527
972 0.3065 0.5593 0.2527
718 0.3065 0.5593 0.2527
488 0.3065 0.5593 0.2527
442 0.3065 0.5593 0.2527
N17AS25.RTE
Calculation of steam distributing
45 12

Calculation of steam distributing

(governing stage data)


degree of admission nozzle area the number of nozzle
Governing
ε Σε FP ΣFP ZP ΣZP
valve N0
/ / cm2 cm2 / /

Ⅰ 9 9
0.450 0.450 51.9748 103.9695
Ⅱ 9 18

Ⅲ 0.275 0.725 63.5369 167.5065 11 29

Ⅳ 0.275 1 63.5369 231.0434 11 40

Note: Ⅰ and Ⅱ governing valve open at the same time

Sketch map of nozzle block arrangement


(View from turbine to generator)

Ⅲ# Ⅱ#

Ⅰ# Ⅳ#
N17AS25.RTE
The thermal process graph (TMCR)
45 13

32
3.9 35 37.1

750
17 .
)
3 390 .6 a(a
MP
s sure
e
pr
e nt ha lp y k J/ kg
71
875 2. 1 temperature ℃
1 3.
33 62. 2
6#
333 8.6 4 52.5
50 4.8
hs= 398.8 kJ/kg
hi= 330.3 kJ/kg

hs= 603.0 kJ/kg


hi= 552.0 kJ/kg
68
1 .0
316 6.0
CY
35 3.7

69
4 .3
306 0.3
7# 06
34 0.3 0.5
29 85.1
4#
26 1.2

39
0.1
2 747 .1
3#
136 .8

71
0.0
263 9.9
TMCR CONDITION 90 .4
2#

Main steam temperature = 540 ℃


hi= 604.9 kJ/kg
hs= 674.7 kJ/kg

Reheat steam temperature = 540 ℃


Main steam mass flow = 972.0 t/h 0.0
29
25 14.8
HP cylinder efficiency = 82.84 % 6 8.5
1#

IP cylinder efficiency = 91.54 %


LP cylinder efficiency = 89.65 %
095
STG output = 330092 kW 0.0
23 80. 2
4 4.8
N17AS25.RTE
The thermal process graph (VWO)
45 14

48
4.1 35 34.9

75 0
17.
)
3 390 .6 a(a
MP
su re
p res
e nt ha lp y k J/ kg
87
711 2. 2 te mp era tu re ℃
1 4.
33 59. 9
6#
335 0.0 4 52.2
51 2.7
hs= 385.9 kJ/kg
hi= 322.2 kJ/kg

hs= 602.8 kJ/kg


hi= 551.7 kJ/kg
24
1 .1
316 3.8
CY
35 3.2

08
4 .6
306 8.4
7# 32
34 5.7 0.5
29 83.2
4#
26 0.7

47
0.1
2 745 .5
3#
136 .4

75
0.0
263 8.6
VWO CONDITION 91 .8
2#

Main steam temperature = 540 ℃


hi= 609.3 kJ/kg
hs= 681.3 kJ/kg

Reheat steam temperature = 540 ℃


Main steam mass flow = 1028.0 t/h 0.0
31
25 13.1
HP cylinder efficiency = 83.5 % 6 9.6
1#

IP cylinder efficiency = 91.53 %


LP cylinder efficiency = 89.43 %
095
STG output = 346369 kW 0.0
23 73. 9
4 4.8
1028.00 1110.0 1028.00 1131.9 0.00
锅炉
boiler
255.00 259.66
△T=2.0

7#
A
91.45 3068.4
△ T=8.0 4.4699
GSH
1028.00 921.7

3 45.7 2 4 .60 81
9 31.9 5 3 068 .4
S
213.66 D

221 .66
540 .00 17. 750
1 028 .00 339 0.6

A
91.45 3068.4
0.0 0

91 .45 951 .9
△T=4.0 345.72 4.6081

B
HP
s

52.72 2931.8

6#
2.2186

452.22
△ T=8.0 1028.00 802.9

52.72 3359.9
186.71 H.E.

temp ℃
flow t/ h
1028.00 780.0 D

1 94. 71
183.68 S

C
GSH

1 44. 17 8 29. 1
DE
45.54 3163.8

FP
1.0903
838.29 642.1
5 40.0 0 4 .14 73
9 31.9 5 3 534 .9

entha lpy kJ/kg


pr essure Mpa(a)

GSH
152.08
S

5.3 7
△T=1.0
D
B

D
64.03 3009.7 0.45

4#
B

0.5164
△ T=8.0 53.17 3359.9
838.29 449.0 452.22 2.2872
B

11 4.74
106.74
IP

△T=3.0 45.54 3163.8

6 4.03 48 1.5
353.17 1.1240
E
C

24.71 2745.5
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1421 58.66 2983.2
△ T=8.0 838.29 373.9 260.67 0.5324
D

S
720.02 370.1 GSH

95.9 6
346369 kW

87.96

88.7 4 4 02.0
2.9679 kg/kW.h
7958.7 kJ/kW.h

11 8.3 396 .7

DP △T=3.0
260 .67 0.53 24
772 .38 298 3.2

GSH
F
S

29.53 2638.6
2#

9 0.96

0.0727
720.02 277.5 29.53 2638.6
2 9.53 38 1.0

65.86 91.77 0.0750


LP

0. 76

△T=3.0
VWO(CW temp 33℃

24.71 2745.5
G

1#

27.52 2520.4 136.39 0.1465


E

0.0296
LP

720.02 192.2 26.76 2513.1


45.92 69.56 0.0306
68 .86
G
℃,Make up 0%)

0.77 2922.1
GSH
27 .52 288 .2
0 .00

0.0951
S
make up

720.02 189.5 GSH


45.28 720.31 187.7 692.00 2373.9
9 8.21

44.84 44.84 0.0095


45

0.29
S
0.77 41 1.6
CP
15

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
1058.84 1108.8 1058.84 1130.8 30.84
锅炉
boiler
254.75 259.41
△T=2.0

7#
A
94.26 3067.6
△ T=8.0 4.4514
GSH
1058.84 920.3

3 45.2 1 4 .58 91
9 29.1 7 3 067 .6
S
213.36 D

221 .36
540 .00 17. 750
1 028 .00 339 0.6

A
94.26 3067.6
0.0 0

94 .26 950 .5
△T=4.0 345.21 4.5891

B
HP
s

54.36 2931.6

6#
2.2055

451.97
△ T=8.0 1058.84 801.3

54.36 3359.5
186.35 H.E.

temp ℃
flow t/ h
1058.84 778.4 D

1 94. 35
183.31 S

C
GSH

1 48. 63 8 27. 4
DE
46.93 3162.9

FP
1.0814
863.28 640.4
5 40.0 0 4 .13 02
9 29.1 7 3 535 .1

entha lpy kJ/kg


pr essure Mpa(a)

GSH
151.68
S

5.3 6
△T=1.0
D
B

D
65.88 3007.6 0.44

4#
B

0.5110
△ T=8.0 54.80 3359.5
863.28 447.5 451.97 2.2737
B

11 4.37
106.37
IP

△T=3.0 46.93 3162.9

6 5.88 48 0.0
352.67 1.1149
E
C

25.44 2744.2
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1403 60.53 2981.8
△ T=8.0 863.28 372.3 259.94 0.5268
D

S
741.58 368.6 GSH

95.6 0
344599 kW

87.60

91.3 3 4 00.5
2.9832 kg/kW.h
8002.1 kJ/kW.h

12 1.7 395 .2

DP △T=3.0
259 .94 0.52 68
764 .71 298 1.8

GSH
F
S

30.38 2637.2
2#

9 0.60

0.0717
741.58 276.1 30.38 2637.2
3 0.38 37 9.5

65.52 91.41 0.0740


LP

0. 74

△T=3.0
VWO(CW temp 33℃

25.44 2744.2
G

1#

27.90 2518.8 135.68 0.1447


E

0.0292
LP

741.58 192.1 27.16 2511.8


45.90 69.22 0.0301
68 .52
G
℃,Make up 3%)

0.77 2921.9
GSH
27 .90 286 .8
3 0.84

0.0951
S
make up

741.58 189.5 GSH


45.28 741.86 187.7 682.34 2374.1
9 8.21

44.84 44.84 0.0095


45

0.28
S
0.77 41 1.6
CP
16

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
972.00 1094.9 972.00 1116.8 0.00
锅炉
boiler
251.78 256.44
△T=2.0

7#
A
84.86 3060.3
△ T=8.0 4.2380
GSH
972.00 909.8

3 40.3 1 4 .36 91
8 82.7 6 3 060 .3
S
210.99 D

218 .99
540 .00 17. 750
972 .00 339 0.6

A
84.86 3060.3
0.0 0

84 .86 939 .6
△T=4.0 340.31 4.3691

B
HP
s

48.97 2927.9

6#
2.1063

452.54
△ T=8.0 972.00 793.0

48.97 3362.2
184.43 H.E.

temp ℃
flow t/ h
972.00 770.1 D

1 92. 43
181.42 S

C
GSH

1 33. 83 8 18. 8
DE
42.50 3166.0

FP
1.0359
795.68 634.0
5 40.0 0 3 .93 22
8 82.7 6 3 537 .1

entha lpy kJ/kg


pr essure Mpa(a)

GSH
150.19
S

5.1 0
△T=1.0
D
B

D
59.98 3011.5 0.43

4#
B

0.4912
△ T=8.0 49.40 3362.2
795.68 442.8 452.54 2.1714
B

11 3.25
105.25
IP

△T=3.0 42.50 3166.0

5 9.98 47 5.2
353.66 1.0680
E
C

23.23 2747.1
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1351 54.88 2985.1
△ T=8.0 795.68 368.2 261.22 0.5063
D

S
684.77 364.5 GSH

94.6 2
330092 kW

86.62

83.2 1 3 96.3
2.9446 kg/kW.h
7970.7 kJ/kW.h

11 0.9 391 .1

DP △T=3.0
261 .22 0.50 63
733 .91 298 5.1

GSH
F
S

27.69 2639.9
2#

8 9.62

0.0691
684.77 272.9 27.69 2639.9
2 7.69 37 5.3

64.75 90.42 0.0713


LP

0. 67

△T=3.0
TMCR(CW temp 33℃

23.23 2747.1
G

1#

24.65 2521.8 136.82 0.1393


E

0.0282
LP

684.77 192.3 23.98 2514.8


45.95 68.45 0.0291
67 .75
G

0.77 2921.3
℃,Make up 0%)

GSH
24 .65 283 .6
0 .00

0.0951
S
make up

684.77 189.5 GSH


45.28 685.04 187.7 659.62 2380.2
9 8.21

44.84 44.84 0.0095


45

0.27
S
0.77 41 1.6
CP
17

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
1008.37 1095.8 1008.37 1117.7 29.37
锅炉
boiler
251.96 256.62
△T=2.0

7#
A
88.30 3061.1
△ T=8.0 4.2505
GSH
1008.37 910.0

3 40.7 5 4 .38 19
8 86.3 3 3 061 .1
S
211.04 D

219 .04
540 .00 17. 750
979 .00 339 0.6

A
88.30 3061.1
0.0 0

88 .30 939 .8
△T=4.0 340.75 4.3819

B
HP
s

50.98 2928.3

6#
2.1082

452.24
△ T=8.0 1008.37 792.7

50.98 3361.5
184.37 H.E.

temp ℃
flow t/ h
1008.37 769.8 D

1 92. 37
181.36 S

C
GSH

1 39. 28 8 18. 6
DE
44.19 3164.7

FP
1.0344
824.89 633.3
5 40.0 0 3 .94 38
8 86.3 3 3 537 .0

entha lpy kJ/kg


pr essure Mpa(a)

GSH
150.03
S

5.1 2
△T=1.0
D
B

D
62.24 3009.2 0.42

4#
B

0.4892
△ T=8.0 51.41 3361.5
824.89 442.0 452.24 2.1734
B

11 3.09
105.09
IP

△T=3.0 44.19 3164.7

6 2.24 47 4.5
353.08 1.0664
E
C

24.11 2745.6
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1343 57.12 2983.5
△ T=8.0 824.89 367.4 260.41 0.5043
D

S
709.82 363.7 GSH

94.4 4
330322 kW

86.44

86.3 5 3 95.6
2.9638 kg/kW.h
8013.5 kJ/kW.h

11 5.1 390 .3

DP △T=3.0
260 .41 0.50 43
731 .52 298 3.5

GSH
F
S

28.72 2638.4
2#

8 9.44

0.0686
709.82 272.1 28.72 2638.4
2 8.72 37 4.6

64.56 90.24 0.0708


LP

0. 66

△T=3.0
TMCR(CW temp 33℃

24.11 2745.6
G

1#

25.34 2520.1 136.05 0.1385


E

0.0280
LP

709.82 192.2 24.68 2513.3


45.93 68.26 0.0289
67 .56
G

0.77 2921.3
℃,Make up 3%)

GSH
25 .34 282 .8
2 9.37

0.0951
S
make up

709.82 189.5 GSH


45.28 710.09 187.7 654.62 2379.6
9 8.21

44.84 44.84 0.0095


45

0.27
S
0.77 41 1.6
CP
18

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
769.00 1035.0 769.00 1056.5 0.00
锅炉
boiler
238.79 243.46
△T=2.0

7#
A
61.84 3043.6
△ T=8.0 3.3945
GSH
769.00 861.8

3 25.0 3 3 .49 95
7 03.5 9 3 043 .6
S
200.15 D

208 .15
540 .00 17. 750
769 .00 339 0.6

A
61.84 3043.6
0.0 0

61 .84 889 .9
△T=4.0 325.03 3.4995

B
HP
s

35.98 2912.1

6#
1.6946

454.51
△ T=8.0 769.00 752.9

35.98 3372.0
175.17 H.E.

temp ℃
flow t/ h
769.00 730.0 D

1 83. 17
172.30 S

C
GSH

97. 82 7 77. 5
DE
31.83 3176.9

FP
0.8370
639.36 600.9
5 40.0 0 3 .14 95
7 03.5 9 3 545 .0

entha lpy kJ/kg


pr essure Mpa(a)

GSH
142.51
S

4.1 0
△T=1.0
D
B

D
45.44 3022.3 0.35

4#
B

0.3986
△ T=8.0 36.33 3372.0
639.36 418.2 454.51 1.7470
B

10 7.41
99.41
IP

△T=3.0 31.83 3176.9

4 5.44 45 0.4
356.99 0.8628
E
C

18.17 2758.8
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1104 41.34 2996.4
△ T=8.0 639.36 344.9 265.24 0.4109
D

S
554.62 341.4 GSH

89.1 1
264080 kW

81.11

63.6 0 3 73.2
2.9120 kg/kW.h
8132.8 kJ/kW.h

8 4.7 367 .9

DP △T=3.0
265 .24 0.41 09
592 .41 299 6.4

GSH
F
S

21.13 2649.0
2#

8 4.11

0.0558
554.62 253.9 21.13 2649.0
2 1.13 35 2.2

60.21 84.88 0.0575


LP

0. 33

△T=3.0
18.17 2758.8
G
80%TMCR(CW temp 33℃

1#

14.90 2531.0 141.46 0.1138


E

0.0231
LP

554.62 193.0 14.57 2525.6


46.11 63.88 0.0238
63 .21
G

0.77 2920.2
GSH
14 .90 264 .6
0 .00

0.0951
℃ ,Make up 0%)

S
make up

554.62 189.5 GSH


45.28 554.84 187.7 539.16 2413.8
9 8.21

44.84 44.84 0.0095


45

0.22
S
0.77 41 1.6
CP
19

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
576.00 965.7 576.00 986.7 0.00
锅炉
boiler
223.52 228.14
△T=2.0

7#
A
42.05 3026.3
△ T=8.0 2.5749
GSH
576.00 805.6

3 08.6 6 2 .65 45
5 31.1 2 3 026 .3
S
187.32 D

195 .32
540 .00 17. 750
576 .00 339 0.6

A
42.05 3026.3
0.0 3

42 .05 831 .9
△T=4.0 308.66 2.6545

B
HP
s

24.63 2892.5

6#
1.2916

456.69
△ T=8.0 576.00 705.5

24.63 3381.9
164.14 H.E.

temp ℃
flow t/ h
576.00 682.7 D

1 72. 14
161.44 S

C
GSH

66. 68 7 28. 8
DE
22.31 3188.4

FP
0.6410
487.02 561.6
5 40.0 0 2 .38 91
5 31.1 2 3 552 .4

entha lpy kJ/kg


pr essure Mpa(a)

GSH
133.31
S

3.1 4
△T=1.0
D
B

D
32.37 3033.9 0.27

4#
B

0.3068
△ T=8.0 24.90 3381.9
487.02 387.9 456.69 1.3316
B

10 0.20
92.20
IP

△T=3.0 22.31 3188.4

3 2.37 42 0.0
360.85 0.6608
E
C

13.11 2771.0
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.0852 29.23 3008.6
△ T=8.0 487.02 317.7 269.93 0.3163
D

S
426.38 314.4 GSH

82.6 7
198121 kW

74.67

45.4 8 3 46.1
2.9073 kg/kW.h
8399.7 kJ/kW.h

6 0.6 340 .9

DP △T=3.0
269 .93 0.31 63
453 .43 300 8.6

GSH
F
S

15.17 2660.0
2#

7 7.67

0.0431
426.38 231.4 15.17 2660.0
1 5.17 32 5.2

54.83 87.94 0.0444


LP

0. 00

△T=3.0
13.11 2771.0
G
60%TMCR(CW temp 33℃

1#

6.93 2538.5 146.58 0.0878


E

0.0180
LP

426.38 194.0 6.93 2538.5


46.36 58.48 0.0186
57 .83
G

0.77 2919.0
GSH
6 .93 242 .1
0 .00

0.0951
℃ ,Make up 0%)

S
make up

426.38 189.5 GSH


45.28 426.55 187.7 418.84 2461.4
9 8.21

44.84 44.84 0.0095


45

0.17
S
0.77 41 1.6
CP
20

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
488.00 928.2 488.00 948.8 0.00
锅炉
boiler
215.14 219.72
△T=2.0

7#
A
33.52 3031.9
△ T=8.0 2.1954
GSH
488.00 774.9

3 06.3 6 2 .26 32
4 51.8 9 3 031 .9
S
180.26 D

188 .26
540 .00 17. 750
488 .00 339 0.6

A
33.52 3031.9
0.1 8

33 .52 800 .3
△T=4.0 306.36 2.2632

B
HP
s

19.85 2881.3

6#
1.1046

458.14
△ T=8.0 488.00 679.5

19.85 3387.3
158.04 H.E.

temp ℃
flow t/ h
488.00 656.7 D

1 66. 04
155.45 S

C
GSH

53. 37 7 02. 0
DE
18.21 3195.2

FP
0.5497
416.42 539.9
5 40.0 0 2 .03 69
4 51.8 9 3 555 .8

entha lpy kJ/kg


pr essure Mpa(a)

GSH
128.21
S

2.6 9
△T=1.0
D
B

D
26.62 3042.1 0.24

4#
B

0.2638
△ T=8.0 20.09 3387.3
416.42 371.2 458.14 1.1388
B

9 6.22
88.22
IP

△T=3.0 18.21 3195.2

2 6.62 40 3.2
363.42 0.5667
E
C

10.87 2779.3
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.0735 23.94 3016.1
△ T=8.0 416.42 302.7 273.09 0.2720
D

S
366.52 299.5 GSH

79.1 2
165279 kW

71.12

37.4 9 3 31.2
2.9526 kg/kW.h
8642.2 kJ/kW.h

4 9.9 326 .0

DP △T=3.0
273 .09 0.27 20
388 .60 301 6.1

GSH
F
S

12.41 2667.7
2#

7 4.12

0.0371
366.52 219.7 12.41 2667.7
1 2.41 31 0.3

52.05 91.43 0.0383


LP

0. 00

△T=3.0
10.87 2779.3
G
50%TMCR(CW temp 33℃

1#

3.95 2548.0 150.33 0.0757


E

0.0158
LP

366.52 194.8 3.95 2548.0


46.53 55.69 0.0163
55 .05
G

0.77 2920.5
GSH
3 .95 230 .4
0 .00

0.0951
℃ ,Make up 0%)

S
make up

366.52 189.5 GSH


45.28 366.70 187.7 361.99 2491.5
9 8.21

44.84 44.84 0.0095


45

0.18
S
0.77 41 1.6
CP
21

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
773.00 1035.3 773.00 1057.4 0.00
锅炉
boiler
239.09 243.83
△T=2.0

7#
A
61.60 3081.8
△ T=8.0 3.4125
GSH
773.00 860.7

3 40.5 6 3 .51 81
7 07.9 1 3 081 .8
S
200.36 D

208 .36
540 .00 14. 906
773 .00 342 2.5

A
61.60 3081.8
0.0 0

61 .60 890 .9
△T=4.0 340.56 3.5181

B
HP
s

37.12 2912.5

6#
1.7021

454.33
△ T=8.0 773.00 749.0

37.12 3371.5
174.81 H.E.

temp ℃
flow t/ h
773.00 730.8 D

1 82. 81
172.48 S

C
GSH

98. 72 7 76. 0
DE
32.10 3176.5

FP
0.8407
642.18 601.6
5 40.0 0 3 .16 63
7 07.9 1 3 544 .8

entha lpy kJ/kg


pr essure Mpa(a)

GSH
142.66
S

4.0 7
△T=1.0
D
B

D
45.65 3024.3 0.35

4#
B

0.4003
△ T=8.0 37.47 3371.5
642.18 418.7 454.33 1.7547
B

10 7.53
99.53
IP

△T=3.0 32.10 3176.5

4 5.65 45 1.0
356.85 0.8667
E
C

18.26 2758.5
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1109 41.58 2996.1
△ T=8.0 642.18 345.4 265.11 0.4127
D

S
557.01 341.8 GSH

89.2 2
264136 kW

81.22

63.9 1 3 73.6
2.9265 kg/kW.h
8162.3 kJ/kW.h

8 5.2 368 .4

DP △T=3.0
265 .11 0.41 27
595 .08 299 6.1

GSH
F
S

21.25 2648.8
2#

8 4.22

0.0561
557.01 254.2 21.25 2648.8
2 1.25 35 2.7

60.30 85.00 0.0578


LP
(CW temp 33℃

0. 28

△T=3.0
18.26 2758.5
G

1#

15.07 2530.0 141.36 0.1143


E

0.0232
LP

557.01 193.0 14.78 2525.3


℃ ,Make up 0%)

46.10 63.97 0.0239


63 .30
G
80% TMCR Sliding Pressure Operation

0.77 2925.7
GSH
15 .07 265 .0
0 .00

0.0951
S
make up

557.01 189.5 GSH


45.28 557.23 187.7 541.40 2413.1
9 8.21

44.84 44.84 0.0095


45

0.22
S
0.77 41 1.6
CP
22

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
586.00 967.2 586.00 989.2 0.00
锅炉
boiler
224.48 229.27
△T=2.0

7#
A
41.76 3118.2
△ T=8.0 2.6217
GSH
586.00 804.5

3 47.8 4 2 .70 27
5 41.5 0 3 118 .2
S
188.06 D

196 .06
540 .00 11. 376
586 .00 346 0.6

A
41.76 3118.2
0.1 6

41 .76 835 .3
△T=4.0 347.84 2.7027

B
HP
s

26.48 2893.9

6#
1.3127

456.39
△ T=8.0 586.00 698.9

26.48 3381.0
163.77 H.E.

temp ℃
flow t/ h
586.00 685.4 D

1 71. 77
162.07 S

C
GSH

68. 24 7 27. 2
DE
22.90 3187.6

FP
0.6513
494.87 563.9
5 40.0 0 2 .43 25
5 41.5 0 3 552 .0

entha lpy kJ/kg


pr essure Mpa(a)

GSH
133.84
S

3.1 1
△T=1.0
D
B

D
32.95 3039.2 0.28

4#
B

0.3116
△ T=8.0 26.75 3381.0
494.87 389.6 456.39 1.3533
B

10 0.62
92.62
IP

△T=3.0 22.90 3187.6

3 2.95 42 1.7
360.52 0.6714
E
C

13.36 2770.4
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.0865 29.84 3007.8
△ T=8.0 494.87 319.3 269.61 0.3212
D

S
433.08 316.0 GSH

83.0 5
198296 kW

75.05

46.3 1 3 47.7
2.9552 kg/kW.h
8488.0 kJ/kW.h

6 1.8 342 .5

DP △T=3.0
269 .61 0.32 12
460 .73 300 7.8

GSH
F
S

15.47 2659.5
2#

7 8.05

0.0437
433.08 232.6 15.47 2659.5
1 5.47 32 6.8

55.13 87.71 0.0451


LP
(CW temp 33℃

0. 00

△T=3.0
13.36 2770.4
G

1#

7.30 2537.8 146.31 0.0892


E

0.0183
LP

433.08 194.0 7.30 2537.8


℃ ,Make up 0%)

46.34 58.79 0.0188


58 .13
G
60% TMCR Sliding Pressure Operation

0.76 2932.0
GSH
7 .30 243 .3
0 .00

0.0951
S
make up

433.08 189.5 GSH


45.28 433.27 187.7 425.21 2458.6
9 8.21

44.84 44.84 0.0095


45

0.19
S
0.76 41 1.6
CP
23

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
494.00 927.2 494.00 949.1 0.00
锅炉
boiler
215.84 220.64
△T=2.0

7#
A
32.95 3138.3
△ T=8.0 2.2253
GSH
494.00 771.4

3 52.6 5 2 .29 41
4 58.5 6 3 138 .3
S 540 .00 9.6 11
180.76 D

188 .76
494 .00 347 9.1

A
32.95 3138.3
0.3 2

32 .95 802 .6
△T=4.0 352.65 2.2941

B
HP
s

21.45 2882.4

6#
1.1170

457.79
△ T=8.0 494.00 669.7

21.45 3386.4
157.27 H.E.

temp ℃
flow t/ h
494.00 658.5 D

1 65. 27
155.86 S

C
GSH

54. 40 6 98. 7
DE
18.58 3194.4

FP
0.5557
421.02 541.4
5 40.0 0 2 .06 47
4 58.5 6 3 555 .5

entha lpy kJ/kg


pr essure Mpa(a)

GSH
128.57
S

2.6 4
△T=1.0
D
B

D
26.92 3048.6 0.24

4#
B

0.2667
△ T=8.0 21.69 3386.4
421.02 372.4 457.79 1.1516
B

9 6.51
88.51
IP

△T=3.0 18.58 3194.4

2 6.92 40 4.4
363.05 0.5729
E
C

11.01 2778.7
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.0742 24.28 3015.3
△ T=8.0 421.02 303.8 272.75 0.2749
D

S
370.50 300.6 GSH

79.3 7
165086 kW

71.37

37.9 3 3 32.3
2.9924 kg/kW.h
8729.7 kJ/kW.h

5 0.5 327 .1

DP △T=3.0
272 .75 0.27 49
392 .93 301 5.3

GSH
F
S

12.59 2667.2
2#

7 4.37

0.0375
370.50 220.5 12.59 2667.2
1 2.59 31 1.4

52.25 91.19 0.0387


LP
(CW temp 33℃

0. 00

△T=3.0
11.01 2778.7
G

1#

4.13 2547.4 150.04 0.0765


E

0.0159
LP

370.50 194.7 4.13 2547.4


℃ ,Make up 0%)

46.52 55.88 0.0164


55 .25
G
50% TMCR Sliding Pressure Operation

0.76 2935.5
GSH
4 .13 231 .2
0 .00

0.0951
S
make up

370.50 189.5 GSH


45.28 370.70 187.7 365.81 2489.3
9 8.21

44.84 44.84 0.0095


45

0.21
S
0.76 41 1.6
CP
24

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
892.00 805.0 892.00 805.0 0.00
锅炉
boiler
187.20 187.20

7#
A
0.00

GSH
892.00 805.0

3 46.9 5 4 .48 98
8 87.5 2 3 074 .5
S
187.20 D

0 .00
540 .00 17. 750
892 .00 339 0.6

A
0.00
0.0 0

B
HP
s

0.00

6#
0.00
892.00 805.0
187.20 H.E.

temp ℃
flow t/ h
892.00 782.2 D

0. 00
184.15 S

C
GSH

DE
48.65 3176.0

FP
1.1021
843.35 644.1
5 40.0 0 4 .04 09
8 87.5 2 3 536 .0

entha lpy kJ/kg


pr essure Mpa(a)

GSH
152.53
S

5.2 9
△T=1.0
D
B

D
64.13 3019.8 0.55

4#
B

0.5226
△ T=8.0 0.55
843.35 451.2
B

11 5.26
107.26
IP

△T=3.0 48.65 3176.0

6 4.13 48 3.7
359.01 1.1362
E
C

25.19 2756.3
Calculated Steam Ra te=
Calculated Heat Ra te=
STG output =

3#
0.1446 58.84 2994.4
△ T=8.0 843.35 374.8 266.17 0.5387
D

S
724.37 371.0 GSH

96.1 8
330552 kW

88.18

89.3 2 4 02.9
2.6985 kg/kW.h
8216.3 kJ/kW.h

11 9.0 397 .7

DP △T=3.0
266 .17 0.53 87
777 .35 299 4.4

GSH
F
S

29.66 2647.0
2#

9 1.18

0.0733
724.37 278.3 29.66 2647.0
2 9.66 38 1.9
(CW temp 33℃

66.03 91.99 0.0756


LP

0. 77

△T=3.0
25.19 2756.3
G

1#

27.85 2528.0 141.78 0.1490


E

0.0299
℃,Make up 0%)

LP

724.37 192.2 27.08 2521.0


The HPHs out of service operation

45.91 69.73 0.0308


69 .03
G

0.77 2922.9
GSH
27 .85 289 .0
0 .00

0.0951
S
make up

724.37 189.5 GSH


45.28 724.65 187.7 696.04 2380.5
9 8.21

44.84 44.84 0.0095


45

0.29
S
0.77 41 1.6
CP
25

GE NERAT OR

T= 33 ℃
N17AS25.RTE

CONDENSER
HP governing valve opening – STG output curve
HP governing valve opening-STG output curve

350
STG output(MW)

300

250

200

150

100

50

0
0 1 2 3 4

N17AS25.RTE
45
HP governing valve opening

26
Main steam mass flow-STG output curve

Main steam mass flow – STG output curve


STG output(MW)

350

300

250

200

150

100
400 500 600 700 800 900 1000 1100

N17AS25.RTE
45
Main steam mass flow(t/h)

27
Heat rate-STG output curve
Heat rate(kJ/kW.h)

9000

Heat rate – STG output curve


8800

8600

8400

8200

8000

7800

N17AS25.RTE
120 160 200 240 280 320 360

45
STG output(MW)

28
Steam rate-STG output curve

2.99
Steam rate(kg/kW.h)

Steam rate – STG output curve


2.98

2.97

2.96

2.95

2.94

2.93

2.92

2.91

2.90
120 160 200 240 280 320 360

N17AS25.RTE
45
STG output(MW)

29
Final feed water temperature – STG output curve
Final feedwater temperature-STG output curve
Final feedwater temperature(℃)

260

250

240

230

220

210
140 160 180 200 220 240 260 280 300 320 340 360

N17AS25.RTE
45
STG output(MW)

30
Cylinder efficiency-STG output curves

Cylinder efficiency – STG output curves


Cylinder efficiency(%)

95

85

75

65

55
140 160 180 200 220 240 260 280 300 320 340 360

N17AS25.RTE
45
HP efficiency IP efficiency LP efficiency
STG output(MW)

31
Pressure after governing stage – STG output curve
Pressure after governing stage-STG output curve
Pressure after governing stage (MPa(a))

16

14

12

10

4
100 150 200 250 300 350 400

N17AS25.RTE
45
STG output(MW)

32
Pressure at extraction point – STG output curves (1)
Pressure at extraction point-STG ouput curves(1)
Pressure at extraction point(MPa(a))

5.0

4.0

3.0

2.0

1.0

0.0
130 150 170 190 210 230 250 270 290 310 330 350

N17AS25.RTE
45
7# 6# 5# 4# STG output(MW)

33
Pressure at extraction point – STG output curves (2)
Pressure at extraction point-STG ouput curves(2)
Pressure at extraction point(MPa(a))

0.18

0.15

0.13

0.10

0.08

0.05

0.03

0.00
140 160 180 200 220 240 260 280 300 320 340 360

N17AS25.RTE
45
3# 2# 1# STG output(MW)

34
Condenser back pressure variation - STG output variation curve
Condenser back pressure variation-STG output variation curve
STG output variation(kW)

8000

6000

4000

2000

-2000

-4000

-6000

-8000

-10000

-12000

N17AS25.RTE
-14000

45
-5 -4 -3 -2 -1 0 1 2 3 4 5 6 7
condenser back pressure variation(kPa)

35
Mechanical and electric loss - STG output curve
Mechanical and electric loss-STG output curve
Mechanical and electric loss(kW)

5500

5000

4500

4000

3500

3000

N17AS25.RTE
2500

45
145 170 195 220 245 270 295 320 345 370
STG output(MW)

36
N17AS25.RT
Calculation of steam velocity (1)
45 37

Calculation of steam velocity (1)

Inside Mass Specific


Area Pressure Velocity
Steam pipe diameter
cm2
flow
MPa(a)
volume
m/s
mm t/h m3/kg
HP main steam pipe
φ270.0
2×φ 1145.11 1028.00 17.7500 0.0186 46.39
(front of valve)
HP main steam pipe
φ165.0
4×φ 855.30 1028.00 17.2175 0.0192 64.04
(rear of valve)
H.E. pipe (High Pressure
φ530.0
2×φ 4412.37 1021.28 4.6081 0.0563 36.21
cylinder Exhaust pipe)
IP main steam pipe
φ460.0
2×φ 3323.80 931.95 4.1473 0.0880 68.56
(front of valve)
IP main steam pipe
φ500.0
2×φ 3926.99 931.95 4.0644 0.0899 59.23
(rear of valve)
IP and LP interconnecting
φ1000.0
2×φ 15707.96 772.38 0.5324 0.4548 62.12
pipe
Low Pressure (cylinder) 6320×7500.0 474000.0 692.00 0.0095 14.0559 57.00
exhaust pipe
Steam extraction pipe 91.45 4.6081 0.0563
(To 7#)
Steam extraction pipe
φ260.0
1×φ 530.93 53.17 2.2872 0.1429 39.76
(To 6#)
Steam extraction pipe
φ444.5
1×φ 1551.79 48.65 1.1362 0.2520 21.95
(To DE) *
Steam extraction pipe
φ546.0
1×φ 2341.40 58.66 0.5324 0.4552 31.68
(To 4#)
Steam extraction pipe
φ438.0
1×φ 1506.74 24.71 0.1465 1.2719 57.94
(To 3#)
Steam extraction pipe
φ488.9
2×φ 3754.57 29.53 0.0750 2.1931 47.91
(To 2#)
Steam extraction pipe
φ539.8
4×φ 9154.10 26.76 0.0306 4.8845 39.66
(To 1#)

NOTE:
1. The calculation of steam velocity is based on VWO condition;
2. The diameter of steam extraction pipe is of turbine side.
3. The calculation of steam velocity marked with (*)is based on THO condition
N17AS25.RT
Calculation of steam velocity (2)
45 38

Calculation of steam velocity (2)-The steam pipe of gland seal


Inside Mass Specific
Area Pressure Velocity
Steam pipe diameter flow volume
cm2 MPa(a) m/s
mm t/h m3/kg
To H.E. 4.607 4.6081

To LPH4 φ102.3
1×φ 82.13 1.504 0.5324 0.6122 31.13
HP
front
Sealing steam φ128.2
1×φ 129.08 0.325 0.1150 2.8356 19.86

To GSH φ94.4
1×φ 69.99 0.046 0.0951 3.4291 6.29

To LPH4 φ102.3
1×φ 82.13 1.994 0.5324 0.4924 33.20

HP
Sealing steam φ128.2
1×φ 129.08 0.407 0.1150 2.2818 20.00
rear
To GSH φ94.4
1×φ 69.99 0.061 0.0951 2.7595 6.68

To LPH4 φ102.3
1×φ 82.13 1.875 0.5324 0.6768 42.91

IP
Sealing steam φ102.3
1×φ 82.13 0.253 0.1150 3.1338 26.77
front
To GSH φ78.9
1×φ 48.89 0.069 0.0951 3.7898 14.94

Sealing steam φ102.3


1×φ 82.13 0.322 0.1150 2.1096 22.95
IP
rear
To GSH φ102.3
1×φ 82.13 0.085 0.0951 2.5512 7.29

Sealing steam φ107.1


2×φ 180.18 -0.559 0.1150 1.6785 25.94
LP
rear
To GSH φ107.1
2×φ 180.18 0.253 0.0951 2.0297 19.62

NOTE:
1. The calculation of steam velocity is based on VWO condition;
2. The negative steam mass flow is referred to leak-in flow.
3. The diameter of steam extraction pipe is of turbine side.
Main steam temperature correction curves
Main steam temperature correction curves

1.0
correction rate(%)

0.8

0.6

0.4

0.2

0.0

-0.2

-0.4

-0.6

N17AS25.RTE
-0.8

45
-1.0
-40 -30 -20 -10 0 10 20 30 40
heat rate STG output main steam temperature variation(℃)

39
Main steam pressure correction curves

Main steam pressure correction curves


8
correction rate(%)

-2

-4

-6

N17AS25.RTE
45
-8
-7 -5 -3 -1 1 3 5 7
heat rate STG output
rate of main steam pressure variation(%)

40
Reheat steam temperature correction curves
Reheat steam temperature correction curves

3
correction rate(%)

-1

-2

N17AS25.RTE
45
-3
-40 -30 -20 -10 0 10 20 30 40
heat rate STG output reheat steam temperature variation(℃)

41
Reheat steam pressure drop correction curves
Reheat steam pressure drop correction curves

2.0
correction rate(%)

1.5

1.0

0.5

0.0

-0.5

-1.0

-1.5

N17AS25.RTE
45
-2.0
4 5 6 7 8 9 10 11 12 13 14 15 16
heat rate STG output reheat steam pressure drop(%)

42
Condenser back pressure correction curves

Condenser back pressure correction curves


correction rate(%)

5.0

4.0

3.0

2.0

1.0

0.0

-1.0

-2.0

-3.0

N17AS25.RTE
45
-4.0
5 6 7 8 9 10 11 12 13 14 15 16
STG output heat rate condenser back pressure(kPa(a))

43
Exhaust volume flow - Exhaust loss curve

Exhaust volume flow - Exhaust loss curve


the last stage exhaust loss(kJ/kg)

40

35

30

25

20

15

N17AS25.RTE
45
10
1500 2000 2500 3000 3500 4000

the last stage exhaust volume flow(m3/s)

44
Exhaust volume flow - LP casing efficiency curve
Exhaust volume flow - LP casing efficiency curve
LP casing efficiency(%)

90.5

90.0

89.5

89.0

88.5

88.0

87.5

87.0

N17AS25.RTE
45
86.5
1550 1800 2050 2300 2550 2800 3050 3300 3550 3800 4050

Exhaust volume flow(m3/s)