Chequeo Cartuchos Pirotécnicos 26-21-00-602
Chequeo Cartuchos Pirotécnicos 26-21-00-602
C. Consumable Materials
None
E. Cartridges check
(1) - Check that cartridge service life has not expired (see MSM).
- Check cartridge resistance.
Connect test set, Squib [ ICO 90.50.00.08.50] cables and carry out tests as per the
following table :
1 Painted steel bottle (PRE MOD 0726050)
NOTE
Connect the milliohmmeter [ Not listed in the ICO] directly to cartridge. For the same
cartridge reference and same terminals, the values to be obtained are identical to
those given in table above. Disregard cable numbers and selector, Squib, Fire [ ICO
90.50.00.11.50] positions.
F. Extinguisher weighing
NOTE
(2) Make sure that the weight of the bottle does not differ by more than ± 20 grams from the
Manufacturer original weight indicated on the FM (log card).
(3) Replace the bottle if the weight is out of tolerance.