Weishaupt dual fuel burners

Sizes 30 to 70
Version NR (NOX-reduction on gas operation)
Description

Weishaupt burners of sizes 30 to 70 were specially designed and developed for capable of overcoming high combustion
industrial applications. The Monoblock-Burners are characterized with multiple chamber pressure, they are most com-
excellent features such as: patible with modern high performance
boilers.
• Big firing range and wide area of applications
• Stable air fan performance – excellent combustion characteristics Fuels
• Burner casing can be swung opened Oil section
• Easy to install, setup and maintenance Light oil (#2 oil), viscosity 6mm2/s at
• Air damper closed off during burner stop 68F (20°C)
• Oil pump and electric oil heater is standard for heavy oil burners Medium to heavy oil (#4 to #6) with vis-
cosity up to 50mm2/s at 212F (100°C)
Control Sizes 40 to 70 Gas section
Control of air and fuel is performed Burner models GL, RGL and RGMS: Natural gas
according to the fuel type, burner size Pressure side air regulation via ratio Propane (LPG)
and requirement: controlled sliding sleeve in the mixing
head Installation location
• Two and three stage The burners are designed for indoor
The oil part of the dual fuel burner Heavy oil burners operation with temperature of 5F
has a nozzle head with two or three Heavy oil burners are equipped with oil (–15°C) up to 100F (+40°C) and rela-
nozzles. The capacity regulation is preheaters, which keep the oil at tive humidity of max. 80%
achieved by opening or closing the oil required temperature to guarantee
solenoid valves 2 and 3 with corres- proper viscosity for good atomization. Certification
ponding changes in air amount. A temperature monitored sequence The burners are in compliance with most
program circulates the preheated oil applicable European and North
• Sliding two stage to the nozzle head before start and American standards
On sliding two stage regulation, the therefore keeps the nozzles at the same
low fire and high fire points are as- temperature. Excellent service
signed within the control range. The Weishaupt has a high density sales and
burner slides depending on heat re- Gas train service network all over the world. The
quirement between both operating As standard, Weishaupt gas and dual customer service is available every day
points. There is no sudden increase or fuel burners are always equipped with around the clock. Optimum in house
decrease of supplied fuel amount. two main gas valves. training conditions ensure high quality of
Gas train can be built according to most service personnel.
• Modulating applicable North American codes and
Modulating burners operate according standards.
to the heat requirement at any operat-
ing point within the control range. Digital combustion manager
W-FM100 and W-FM200 combustion
Reduced starting capacity manager control all essential burner
The burner starts at ignition position via functions, e.g. fuel and air supply and
separated pilot line. This way only a monitor the flame with digital precision.
small amount of gas flows into the com- The target is optimization of operating
bustion chamber. After a certain delay conditions, maximization of economical
time the burner operates in low fire. aspect and minimizing the emissions.
Thanks to the digital combustion tech-
Controlled shutdown from low fire nology, such optimization is available
Controlled shutdown of the burner is today at reasonable cost. Expenses for
performed only at low fire. Sudden pres- installation and maintenance are even
sure surge in the gas supply line can be clearly lower than with conventional
avoided. technologies. For example, a separate
remote panel is no longer required for
Fuel – air ratio burner control. Furthermore, remote
The regulation of fuel to air ratio varies operation, remote diagnostic and remote
depending on the burner model: monitoring of the appliances are now
realizable. This increases the safety and
Size 30 comfort for operator.
Burner models RGL and RGMS:
Pressure side air regulation via ratio con- Applications
trolled sliding sleeve in the mixing head The burners can be used with heat
Burner model GL: Pressure side air reg- exchanger such as boilers, air heaters
ulation via adjustable flame tube accord- and for certain process applications.
ing to the firing rate Due to the fact that the burner is
2
versions
Digital combustion manager
Digital combustion manager
Digital combustion manager (W-FM100)
(W-FM100)
(W-FM100) with modulating controller
with modulating controller
and speed control

standard

optional

Capacity regulation

Two stage (ZM) HF Sliding two stage HF


Oil part (ZM)

LF LF

IP

ON OFF ON OFF

Three stage (TM) HF Modulating HF


Oil part (ZM)
S2 LF
HF =High fire
LF LF = Low fire
IP
IP = Ignition Position
S2 = Stage 2 (TM) ON OFF
ON OFF

Burner designation

RGL 40/1 – B, Vers. ZM-NR GL 40/1 – B, Vers. TM-NR


NOx-reduction NOx-reduction
ZM =Gas/Oil: sliding two stage ZM =Gas: Sliding two stage or
or modulating modulating
Oil: Two stage
Index for Mixing head
TM = Gas: Sliding two stage or
Code for capacity range modulating
Oil: Three stage
Size
Index for mixing head
Fuel: Light oil
Code for capacity range
Fuel: Gas
Size
Modulating burner (oil part)
Fuel: Light oil (#2 oil)
Fuel: Gas

3
The advantages of
digital combustion management

Digital combustion management Integration with building management


means optimum combustion figures, For control and management functions,
continuous repeatability of setting Weishaupt offers ProGraf NT - a
values and ease of use. software product that provides a real
time solution to meet all requirements.
Weishaupt burners are equipped with
electronic ratio controller and digital The price advantage of the new
combustion management to satisfy the technology
requirements of modern combustion With improved technology and ease of
technology, which demand a precise and use, combustion plant is becoming even
continuously reproducible supply of fuel more economical than ever before.
and combustion air. Only in this way
optimal combustion figures can be • No additional burner controls are
ensured over extended periods of time. required, since this function is already
governed by the combustion manager.
If required, the burners can also be Fuses and burner motor starter are the
Control and Display Unit equipped with O2 trim* and variable only additional items required.
speed control.
• Less installation work means less
Error free operation via AZL display errors: the burners are tested as a
and control unit complete unit at the factory.
Setting and control of the burner func-
tions are achieved using a control and • If required, the W-FM 100 is available
display unit, the AZL, which is equipped with an integrated modulating con-
with an LCD display. The AZL is con- troller and variable speed module. No
nected to the combustion manager via a separate equipment is required. The
safety bus system and can be posi- modulating controller and variable
tioned anywhere according to the user’s speed module are included as stan-
preferences within 325 ft. (100 m) dis- dard with the W-FM 200.
tance from the burner.
• Commissioning and service work
Flexible communication possibilities takes less time. The initial presetting
The integrated communication interface of the burner is carried out at the fac-
enables all necessary information and tory. On site, only the site specific
functions to be transmitted to a BMS operating points have to be adjusted.
system. If required, remote operation and
remote diagnosis functions, which are • To facilitate O2 trim, only an O2 probe
accessible via modem, can be installed and O2 module have to be installed
(e.g. oil/gas change-over, adjustment of and connected with the W-FM 200
setting values). via the internal safety BUS.

Communication with external systems


via BUS
If data has to be exchanged between
burners and other heating systems with
PLC devices, the information can be
accessible via eBUS or MODBUS
communication system.

* In conjunction with W-FM 200 combustion


manager

4
O2 probe*
O2 module*

Gas butterfly

Sliding sleeve Stepping


motors

Oil regulator

Air damper

Frequency Impulse sender


converter

CAN-BUS

W-FM 200 combustion


manager

CAN-BUS

eBUS/
Control and MODBUS BMS
Display Unit visualization
AZL ProGraf NT

Example of O2 trim and speed control with W-FM 200


5
Proven quality in detail

Increased safety via shut off


assembly with solenoid
valve
The electromagnetic actuated safety
shut off device isolates the oil supply and
return on burner models RGL40 to 70
and RGMS30 to 70 when the burner
shuts down. Oil shut off directly at the
nozzle ensures a drip free burner shut
down. (Burner type RGL30 uses a
system without nozzle shut off).

Cut-away view of a nozzle shut of assembly

Considerable noise
reduction due to sound
absorbing air inlet
By utilizing sound absorbing materials on
the fan suction side it has been possible
to reduce operational noise considerably.

Cut-away view of the fan housing

Pressure side air regulation


via mixing head with ratio
controlled sliding sleeve
The forward and reverse movements of
the regulating sleeve in the mixing head
ensure that the air supply gap is correct
at every operating point throughout the
capacity range. This results in optimum
velocities over the whole range of
regulation. With this system, the mixing
pressure is increased at low fire,
improving the mixing effect of fuel and air. Turn down ratio up to 1:5
This results in a reduction in excess air
and improved combustion efficiency due
to the constant air/fuel ratio.

Turn down ratio up to 1:3

Burner sizes 40 to 70 with pressure side ratio controlled sliding sleeve


Burner without pressure side sliding sleeve
Example of turn down ratio for different burner models

6
RGL70/2-A ZM NR dual fuel burner

Burner with integrated AZL Control and Display Unit

7
RGMS30/2-A ZM NR dual fuel burner complete with burner mounted oil preheater

Burner with inbuilt Control and Display Unit

8
Dual fuel burner selection

Models GL, RGL and RGMS30, NR version


[“WC ] Burner model GL30/2-A, vers. ZM-NR Comb. head open [“WC] Burner model RGL30/2-A, vers. ZM-NR RGMS30/2-A, vers. ZM-NR
GL30/2-A, vers. TM-NR Combustion head G30/2-NR 190x65 G30/2-NR 190x65
Comb. head closed
Combustion head G30/2-NR 190x65 MBH Nat. Gas/LPG 1,000 – 7,850 1,000 – 7,850
MBH Nat. Gas/LPG 1,000 – 7,850 GPH Light oil #2 12– 56 –
GPH Light oil #2 12 – 56 Heavy oil #6 – 17 – 52
5 6

4 5

4
3
3
2
2
1 1
Gas/LPG

Gas/LPG

Nat. Gas

Heavy oil
Propane
Light oil

Light oil

Light oil
0 0

-1 -1
[MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 [MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000

[GPH] #2 0 10 20 30 40 50 [GPH] #2 0 10 20 30 40 50

[GPH] #6 0 10 20 30 40 50

Models GL, RGL and RGMS40, NR version


[“WC ] Burner model GL40/1-B, vers. TM-NR [“WC] Burner model RGL40/1-B, vers. ZM-NR RGMS40/1-B, vers. ZM-NR
Combustion head G30/2-NR 190x58 Combustion head G30/2-NR 190x58 G30/2-NR 190x58
MBH Nat. Gas/LPG 1,535 – 9,215 MBH Nat. Gas/LPG 1,535 – 9,215 1,535 – 9,215
GPH Light oil #2 13 – 66 GPH Light oil #2 13– 66 –
Heavy oil #6 – 19 – 62
7 7
6 6
5 5
4 4
3 3
2 2
Heavy oil
Gas/LPG
Gas/LPG

1 1
Light oil
Light oil

0 0
-1 -1
[MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 [MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000

[GPH] #2 0 10 20 30 40 50 60 [GPH] #2 0 10 20 30 40 50 60

[GPH] #6 0 10 20 30 40 50 60

[“WC ] Burner model GL40/2-A, vers. TM-NR [“WC] Burner model RGL40/2-A, vers. ZM-NR RGMS40/2-A, vers. ZM-NR
Combustion head G40/2-NR 217x75 Combustion head G40/2-NR 217x75 G40/2-NR 217x75
MBH Nat. Gas/LPG 1,700 – 11,800 MBH Nat. Gas/LPG 1,700 – 11,800 1,700 – 11,800
GPH Light oil #2 16 – 84 GPH Light oil #2 16 – 84 –
Heavy oil #6 – 25 – 79
7 7
6 6
5 5
4 4
3 3
2 2
Heavy oil
Gas/LPG

Gas/LPG

1 1
Light oil

Light oil

0 0
-1 -1
[MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000 [MBH] 0 1,000 2,000 3,000 4,000 5,000 6,000 7,000 8,000 9,000 10,000 11,000 12,000

[GPH] #2 0 10 20 30 40 50 60 70 80 GPH] #2 0 10 20 30 40 50 60 70 80

[GPH] #6 0 10 20 30 40 50 60 70 80

9
Dual fuel burner selection

Models RGL and RGMS50, NR version


[“WC] Burner model RGL50/1-B, vers. ZM-NR RGMS50/1-B, vers. ZM-NR [“WC ] Burner model RGL50/2-A, vers. ZM-NR RGMS50/2-A, vers. ZM-NR
Combustion head G40/2-NR 217x75 G40/2-NR 217x75 Combustion head G50/2-NR 290x185 G50/2-NR 290x185
MBH Nat. Gas/LPG 1,875 – 13,650 1,875 – 13,650 MBH Nat. Gas 2,050 – 18,450 2,730 – 18,450
GPH Light oil #2 16 – 97 – LPG 2,730 – 18,450 2,730 – 18,450
Heavy oil #6 – 28 – 91 GPH Light oil #2 27 – 131 –
Heavy oil #6 – 36 – 123
8 8
7 7
6 6
5 5
4 4
3 3
2 2
Heavy oil

Heavy oil
Gas/LPG

Propane
Light oil

Light oil
1 1

Gas
0 0
-1 -1
[MBH] 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 [MBH] 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000

[GPH] #2 0 10 20 30 40 50 60 70 80 90 [GPH] #2 0 20 40 60 80 100 120

[GPH] #6 0 10 20 30 40 50 60 70 80 90 [GPH] #6 0 20 40 60 80 100 120

Models RGL and RGMS60, NR version


[“WC ] Burner model RGL60/2-A, vers. ZM-NR RGMS60/2-A, vers. ZM-NR The ratings given are based on fuel with low calorific value,
Combustion head G60/2-NR 345x230 G60/2-NR 345x230
MBH Nat. Gas/LPG 2,730 – 20,800 2,730 – 20,800 an air temperature of 68F (20°C) and an installation altitude
GPH Light oil #2 32 – 148 – of 1,640 ft. (500 m).
Heavy oil #6 – 44 – 139

8
The stated oil throughputs are based on a calorific value of
7 140,000 BTU/Gal for light oil and 150,000 BTU/Gal for heavy
6 oil
5
4 Voltages and frequencies:
3 As standard, the burners are suitable for three phase alternating
2 current with voltages available between 208 - 600V, 60Hz.
Heavy oil
Gas/LPG

Different voltages and frequency available on request.


Light oil

1
0
-1 Standard burner motor:
[MBH] 0 2,000 4,000 6,000 8,000 10,000 12,000 14,000 16,000 18,000 20,000 22,000
Isolation class F, IP 54 protection
[GPH] #2 0 20 40 60 80 100 120 140

[GPH] #6 0 20 40 60 80 100 120 140

10
Dual fuel burner selection

Models RGL and RGMS70, NR version


[“WC] Burner model RGL70/1-B, vers. ZM-NR RGMS70/1-B, vers. ZM-NR [“WC] Burner model RGL70/2-A, vers. ZM-NR RGMS70/2-A, vers. ZM-NR
Combustion head G60/2A-NR 345x230 G70/2A-NR 345x230 Combustion head G70/2A-NR 425x295 G70/2A-NR 425x290
MBH Nat. Gas/LPG 2,730 – 25,250 2,730 – 25,250 MBH Nat. Gas 3,400 – 35,850 3,400 – 35,850
GPH Light oil #2 29 – 179 – LPG 4,750 – 35,850 4,750 – 35,850
Heavy oil #6 – 48 – 168.5 GPH Light oil #2 46 – 255 –
Heavy oil #6 – 52 – 239
9 9
8 8
7 7
6 6
5 5
4 4
3 3
2 2

Heavy oil
Heavy oil

Propane
Gas/LPG

Light oil
Light oil

1 1

Gas
0 0
-1 -1
[MBH] 0 4,000 8,000 12,000 16,000 20,000 24,000 [MBH] 0 6,000 12,000 18,000 24,000 30,000 36,000

[GPH] #2 0 20 40 60 80 100 120 140 160 180 [GPH] #2 0 30 60 90 120 150 180 210 240 270

[GPH] #6 0 20 40 60 80 100 120 140 160 [GPH] #6 0 30 60 90 120 150 180 210 240

The ratings given are based on fuel with low calorific value,
an air temperature of 68F (20°C) and an installation altitude
of 1,640 ft. (500 m).

The stated oil throughputs are based on a calorific value of


140,000 BTU/Gal for light oil and 150,000 BTU/Gal for heavy
oil

Voltages and frequencies:


As standard, the burners are suitable for three phase alternating
current with voltages available between 208 - 600V, 60Hz.
Different voltages and frequency available on request.

Standard burner motor:


Isolation class F, IP 54 protection

11
Scope of delivery

Description GL30-ZM GL30-TM RGL30 RGMS30 GL40-TM RGL40 RGMS40 RGL60 RGMS60
RGL50 RGMS50 RGL70 RGMS70
Burner housing, hinged flange, housing cover,
Weishaupt burner motor, air intake housing, fan
wheel, combustion head, ignition unit, ignition cable,
ignition electrodes, nozzle assembly with oil nozzle(s),
combustion manager with control unit, flame sensor,
flange gasket, limit switch on hinged flange,
fixing bolts ● ● ● ● ● ● ● ● ●
W-FM 100 combustion manager ● ● ● ● ● ● ● ● ●
Double main gas valves ● ● ● ● ● ● ● ● ●
Gas butterfly valve ● ● ● ● ● ● ● ● ●
Pilot valves ● ● ● ● ● ● ● ● ●
Connection piece ● ● ● ● ● ● ● ● ●
Air pressure switch ● ● ● ● ● ● ● ● ●
Oil pressure switch in return ● ● ● ● ● ● ●
Gas pressure switch ● ● ● ● ● ● ● ● ●
Adjustable regulating sleeve
in the mixing head ● ●
Ratio controlled sliding sleeve
in the mixing head ● ● ● ● ● ● ●
Servomotor for fuel/air ratio
regulation via W-FM 100
Servomotor for air damper ● ● ● ● ● ● ● ● ●
Servomotor for gas butterfly ● ● ● ● ● ● ● ● ●
Servomotor for oil regulator ● ● ● ● ● ●
Servomotor for regulating sliding sleeve ● ● ● ● ● ● ●
Oil pump ● ● ● ●➀ ● ● ●➀ ● ●➁
Oil preheater ●➀ ●➀ ●➁
Oil hoses ● ● ● ● ● ● ● ● ●
2 oil solenoid valves, 1 safety valve,
two stage nozzle assembly without shut off ●
2 oil solenoid valves, 1 safety valve, three
stage nozzle assembly with solenoid shut off ● ● ●
3 oil solenoid valves, 1 safety valve, three stage
nozzle assembly without shut off ● ●
2 solenoid valves in flow and return,
nozzle assembly without shut off ●
1 solenoid valve in flow and return,
nozzle assembly with solenoid shut off ● ●
Electromagnetic clutch ● ● ● ● ● ● ● ● ●

➀ Heavy oil burners, sizes 30 to 50, are equipped as standard with integral oil pump and electric oil preheater. If required, an additional
medium oil preheater can be supplied as an option (refer to special equipment).
➁ For heavy oil burners, sizes 60 and 70 remote pump and preheater stations are required.

12
Special equipment

Description Size 30 Size 40 Size 50 Size 60 Size 70

Vertically firing burner version standard standard standard standard standard

Air intake flange for connection of an air duct 280 003 47 280 001 68 280 000 92 280 000 38 280 000 13

Combustion head extension by 6” (150 mm) GL../2-A, vers. ZM-NR 290 005 15 – – – –
GL../1-B, vers. TM-NR – 290 005 27 – – –
GL../2-A, vers. TM-NR 290 005 17 290 005 07 – – –
RGL../1-B, vers. ZM-NR – 290 005 29 290 005 09 – 290 011 40
RGL../2-A, vers. ZM-NR 290 005 19 290 005 09 290 004 99 290 004 19 290 004 85
RGMS../1-B, vers. ZM-NR – 290 011 25 290 009 42 – 290 011 42
RGMS../2-A, vers. ZM-NR * 290 011 27 290 011 30 290 011 32 290 011 34

by 12” (300 mm) GL../2-A, vers. ZM-NR 290 005 16 – – – –


GL../1-B, vers. TM-NR – 290 005 28 – – –
GL../2-A, vers. TM-NR 290 005 18 290 005 08 – – –
RGL../1-B, vers. ZM-NR – 290 005 30 290 005 10 – 290 011 41
RGL../..-A, vers. ZM-NR 290 005 20 290 005 10 290 005 00 290 004 20 290 004 86
RGMS../1-B, vers. ZM-NR – 290 011 26 290 011 29 – 290 011 43
RGMS../2-A, vers. ZM-NR * 290 011 28 290 011 31 290 011 33 290 010 96

W-FM 100 with internal modulating controller 290 010 60 290 010 60 290 010 60 290 010 60 290 010 60

Burner controller
Mechanical linkage with LFL in lieu of W-FM 100 -price reduction- 290 011 02 290 011 02 290 011 02 290 011 02 290 011 02
Mechanical linkage with LGK in lieu of W-FM 100 -price reduction- 290 011 03 290 011 03 290 011 03 290 011 03 290 011 03

Solenoid valve for air pressure switch test


for continuous run fan or post purge 290 004 29 290 004 29 290 000 31 290 000 31 290 000 31

Oil preheater
WEV2.2 in lieu of EV2D on RGMS 30 and 40 RGMS../1-B, vers. ZM-NR – 290 001 68 290 002 26 – –
WEV3/01 in lieu of WEV2.2/01 on RGMS50 RGMS../2-A, vers. ZM-NR 290 001 68 290 001 68 290 002 26 – –

MV9C oil preheater (medium) in addition to standard integral electric oil preheater
RGMS../1-B, vers. ZM-NR – 280 003 34 280 002 98 – –
RGMS../2-A, vers. ZM-NR 280 003 60 280 003 34 280 001 17 – –

Fittings type for medium preheater station in conjunction with electric preheater
screwed for warm water up to 230F (110°C) 120 001 70 120 001 70 120 001 70 – –
flanged for warm water up to 230F (110°C) 120 001 78 120 001 78 120 001 78 – –
flanged for hot water from 230F (110°C) 120 001 79 120 001 79 120 001 79 – –
up to 355F (180°C)

screwed for low pressure steam from 7.2 PSI (0.5 bar) 280 001 18 280 001 18 280 001 18 – –
up to 21.7 PSI (1.5 bar)
screwed for high pressure steam from 21.7 PSI (1.5 bar) 280 001 19 280 001 19 280 001 19 – –
up to 217.5 PSI (15 bar)

flanged for high pressure steam from 174 PSI (12 bar) 280 001 21 280 001 21 280 001 21 – –
up to 290 PSI (20 bar)
flanged for high pressure steam from 290 PSI (20 bar) 280 001 22 280 001 22 280 001 22 – –
up to 362.5 PSI (25 bar)

flanged for thermal fluid up to 480 F (250°C) 120 001 75 120 001 75 120 001 75 – –
flanged for thermal fluid up to 570 F (300°C) 120 001 77 120 001 77 120 001 77 – –

* on request

13
Technical data
Sizes 30 and 40

Description GL30/2-A RGL30/2-A RGMS30/2-A

Burner motor Model D112/110-2 D112/110-2 D112/110-2


Motor rating HP (kW) 6.7 (5.0) 6.7 (5.0) 6.7 (5.0)
Full Load Amps (FLA) at 460 V A 8.2 8.2 8.2
Speed (60 Hz) rpm 3510 3510 3510
Fan wheel colour / ø red / 248 x 100 red / 248 x 100 red / 248 x 100
Combustion manager Model W-FM100 W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45 SQM 45
Integral pump Model J6 TA3 TA3
Oil preheater Model – – EV2D
Oil throughput GPH (kg/h) – – 72 (270)
Heating capacity kW – – 13.2
Oil solenoid valve 110V 1/4” 20 W Model 121 K 6220
110V 1/8” 19 W Model 121 K 2423 – –
55V 1/4” (supply) 20 W Model – 121 K 6220 –
55V 1/8” (return) 20 W Model – 121 K 2423 –
55V 3/8” (supply) 20 W Model – – 321 H 2322
55V 3/8” (return) 20 W Model – – 121 G 2320
Oil pressure switch 1 - 10 bar (light oil return - 5 bar) Model – DSA 46 F001
1 - 10 bar (heavy oil return - 7 bar) Model – – DSA 46 F001
Oil hoses DN / Length 13/40” (1000mm) 20/40” (1000mm) –
(High pressure metal hoses for RGMS) DN / Length – – 20/51” (1300mm)
Burner weight lbs (kg) 297 (135) 319 (145) 385 (175)

Description GL40/1-B RGL40/1-B RGMS40/1-B


GL40/2-A* RGL40/2-A* RGMS40/2-A*
Burner motor Model D112/140-2 D112/140-2 D112/140-2
Motor rating HP (kW) 10.5 (7.8) 10.5 (7.8) 10.5 (7.8)
Full Load Amps (FLA) at 460 V A 11.5 11.5 11.5
Speed (60 Hz) rpm 3450 3450 3450
Fan wheel colour / ø red / 275 x 100 red / 275 x 100 red / 275 x 100
Combustion manager Model W-FM100 W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45 SQM 45
Integral pump Model J6➀ TA3 TA3
Oil preheater Model – – EV2D➁
Oil throughput GPH (kg/h) – – 72 (270)
Heating capacity kW – – 13.2
Oil solenoid valve 110V 1/8” 19 W Model 121 K 2423 – –
110V 1/4” (safety valve) 20 W Model 121 K 6220 – –
55V 3/8” (supply) 20 W Model – 321 H 2322 321 H 2322
55V 3/8” (return) 20 W Model – 121 G 2320 121 G 2320
Oil pressure switch 1 - 10 bar (light oil return - 5 bar) Model – DSA 46 F001 –
1 - 10 bar (heavy oil return - 7 bar) Model – – DSA 46 F001
Oil hoses DN / Length 13/40” (1000mm) 20/40” (1000mm) –
(High pressure metal hoses for RGMS) DN / Length – – 20/51” (1300mm)
Burner weight lbs (kg) 352 (160) 352 (160) 418 (190)

➀ Light oil burners > 60 GPH (200 kg/h): oil pump J7 in lieu of J6 (refer to Special Equipment for additional cost)
Light oil burners > 72 GPH (250 kg/h): oil pump TA2 in lieu of J6 (refer to Special Equipment for additional cost)
➁ Heavy oil burners > 74 GPH (270 kg/h): oil preheater WEV2.2 in lieu of EV2D (refer to Special Equipment for additional cost)
* Burner types …/2-A with burner motor type 112/140-2; nominal capacity 7 kW; nominal load 13.4 A; motor prefuse 25 A

14
Technical data
Size 50

Description RGL50/1-B RGL50/2-A

Burner motor Model D132/170-2a D132/170-2


Motor rating HP (kW) 14 (10.5) 20 (15)
Full Load Amps (FLA) at 460 V A 17.2 23.2
Speed (60 Hz) rpm 3500 3500
Fan wheel colour / ø red / 330 x 100 red / 330 x 100
Combustion manager Model W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45
Integral pump Model TA4C T2C
Oil solenoid valve 55V 3/8” (supply) 20W Model 321 H 2322 321 H 2322
55V 3/8” (return) 20W Model 121 G 2320 121 G 2320
Oil pressure switch 1 - 10 bar (light oil return - 5 bar) Model DSA 46 F001 DSA 46 F001
1 - 10 bar (heavy oil return - 7 bar) Model – –
Oil hoses DN / Length 25/51” (1300mm) 25/51” (1300mm)
Burner weight lbs (kg) 517 (235) 528 (240)

Description RGMS50/1-B RGMS50/2-A

Burner motor Model D132/170-2 D132/170-2


Motor rating HP (kW) 14 (10.5) 20 (15)
Full Load Amps (FLA)at 460 V A 17.2 23.2
Speed (60 Hz) rpm 3500 3500
Fan wheel colour / ø red / 330 x 100 red / 330 x 100
Combustion manager Model W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45
Oil preheater Model WEV2.2/01➂ WEV3/01
Oil throughput GPH (kg/h) 80 (300) 133 (500)
Heating capacity kW 13.8 22.4
Integral pump Model TA4C T2C
Oil solenoid valve 55V 3/8” (supply) 20W Model 321 H 2322 321 H 2322
55V 3/8” (return) 20W Model 121 G 2320 121 G 2320
Oil pressure switch 1 - 10 bar (heavy oil return - 7 bar) Model DSA 46 F001 DSA 46 F001
Oil hoses DN / Length 25/59” (1500mm) 25/59” (1500mm)
Burner weight lbs (kg) 605 (275) 616 (280)

➂ Heavy oil burners > 80 GPH (300 kg/h): oil preheater WEV3 in lieu of WEV2.2 (refer to Special Equipment for extra cost)

15
Technical data
Sizes 60 and 70

Description RGL60/2-A RGMS60/2-A

Burner motor Model D132/170-2 D132/170-2


Motor rating HP (kW) 20 (15) 20 (15)
Full Load Amps (FLA) at 460 V A 23.2 23.2
Speed (60 Hz) rpm 3500 3500
Fan wheel colour / ø red / 465 x 103 red / 465 x 103
Combustion manager Model W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45
Integral pump Model T2C –
Oil solenoid valve 55V 3/8” (supply) 20W Model 321 H 2322 321 H 2322
55V 3/8” (return) 20W Model 121 G 2320 121 G 2320
110V 3/8” (Bypass) 19W Model – 322 H 7306
Oil pressure switch 2 – 40 bar (supply 18 bar) Model – DSA 58 F001
1 - 10 bar (light oil return - 5 bar) Model DSA 46 F001 –
1 - 10 bar (heavy oil return - 7 bar) Model – DSA 46 F001
Oil hoses DN / Length 25/51” (1300mm) –
(High pressure metal hoses for RGMS) DN / Length – 16/59” (1500)
Burner weight lbs (kg) 726 (330) 671 (305)➀

➀ Weight excluding pump station and preheater station

Description RGL70/1-B RGL70/2-A RGMS70/1-B RGMS70/2-A

Burner motor Model D160/215-2B D160/215-2 D160/215-2B D160/215-2


Motor rating HP (kW) 25 (19) 29.5 (22) 25 (19) 29,5 (22)
Full Load Amps (FLA) at 460 V A 32.2 36 32.2 36
Speed (60 Hz) rpm 3400 3500 3400 3500
Fan wheel colour / ø green / 530 x 120 green / 530 x 120 green / 530 x 120 green / 530 x 120
Combustion manager Model W-FM100 W-FM100 W-FM100 W-FM100
Ignition unit Model W-ZG02/2 W-ZG02/2 W-ZG02/2 W-ZG02/2
Servomotor Model SQM 45 SQM 45 SQM 45 SQM 45
Integral pump Model T2C (< 175 GPH) T2C (< 175 GPH) – –
(< 600 kg/h) (< 600 kg/h)
Model T3C (> 175 GPH) T3C (> 175 GPH) – –
(> 600 kg/h) (> 600 kg/h)
Oil solenoid valve 55V 1/2” (supply) 20W Model 321 H 2522 321 H 2522 321 H 2522 321 H 2522
55V 1/2” (return) 20W Model 121 G 2520 121 G 2520 121 G 2520 121 G 2520
110V 3/8” (Bypass) 19W Model – – 322 H 7306 322 H 7306
Oil pressure switch2 – 40 bar (supply - 18 bar) Model – – DSA 58 F001 DSA 58 F001
1 - 10 bar (light oil return - 5 bar) Model DSA 46 F001 DSA 46 F001 – –
1 - 10 bar (heavy oil return - 7 bar) Model – – DSA 46 F001 DSA 46 F001
Oil hoses DN / Length 25/51” (1300mm) 25/51” (1300mm) – –
(High pressure metal hoses for RGMS) DN / Length – – 20/59” (1500mm) 20/59” (1500mm)
Burner weight lbs (kg) 957 (435) 957 (435) 902 (410)➀ 902 (410)➀

➀ Weight excluding pump station and preheater station

16
Burner fuel systems

Model GL30Z (oil part) Models GL30T / GL40T (oil part) Models RGL30 (oil part)
10 13 13a 16a 10 13 13a 16a 10 12 12 16a

55V 55V

55V 55V
P M

13a 13a 13a 12a 14 15 12a

Models RGL40 to RGL70 (oil part) Models 30 to 70 (gas part) Legend

1 Isolating cock
10 17 11 18 14 12 16 6 7 4b 4b 9 2 Main gas pressure regulator
ϑ P
3 Low gas pressure switch
4 Double main gas valve
55V 4b Pilot gas valve
5 High gas pressure switch
6 Isolating valve (pilot)
55V 7 Pilot gas pressure regulator
ϑ P M 8 Gas butterfly valve
9 Burner
P P
10 Oil pump
11 Oil filter
12b 12a 18 14a 15 2 3 4 1 5 8
12 Normally closed oil solenoid valve (55 V,
electrically connected in series with 12a)
12a Normally closed oil solenoid valve (55 V,
Models RGMS30 to RGMS50 (oil part) Models RGMS60 and RGMS70 (oil part) electrically connected in series with 12,
Integral pump and preheater With separate pump and preheater stations installed against the direction of flow)
12b Normally open bypass oil solenoid valve
10 11 12 17 18 16 10 17 11 18 14 12 16
13 Normally closed oil solenoid valve
ϑ ϑ P 13a Normally closed oil solenoid valve for
stages 1, 2 and 3
55V 55V
14 Oil pressure switch in supply line
14a Oil pressure switch in return line
15 Oil regulator
55V 55V
P ϑ P
16 Nozzle assembly with shut off device
M M
(solenoid valve)
16a Nozzle assembly without shut off device
17 Oil preheater
12a 14 15 12b 12a 18 14a 15
18 Pt100 temperature sensor (to monitor
minimum oil temperature

17
Pump and preheater stations
Description

Scope of delivery - pump stations If operating steam at more than 110 PSI General instructions
Pump unit (screw spindle pump with (7.5 bar) or hot water between 355F When starting a boiler from a cold
motor), pressure gauge, vacuum gauge, (180°C) and 390F (200°C) is condition with residual oil, the capacity of
pressure regulating valve, ball valves, continuously available, then an electric electric oil preheater must be at least
suction flange, pressure flange including preheater is not required. This is also 30% of the boiler rating. On hot water
counter flanges, screws and washers, possible if plant with the above minimum boilers up to 265F (130°C) operating
suction-side filter. All parts fully pressures or temperatures to be temperature, the electric oil preheaters
assembled on an oil drip tray. operated with light oil or gas. must be able to produce the full boiler
output without utilizing medium
The pump station is available in two If the medium temperature is not preheaters. Use of a medium preheater is
different versions - either as a single sufficient to adequately preheat the fuel not suitable for medium temperatures
station unit with one pump, or as a twin oil, then the electric oil preheater inputs below 212F (100°C). The number of
station unit with two pumps, one pump the additional heat required. The electric media oil preheaters to be selected
being a backup unit. Should one of the oil preheater heats the oil for the start up depends on the oil throughput and can
pump fail, it is possible to quickly switch of the plant. If the required medium be taken from the capacity charts (see
over to the other one. temperature is available then the station the technical brochure “Weishaupt
switches over to the medium oil electric and media oil preheaters”).
Only proven makes of pump are used. preheater thus saving on electricity.
The pumps are carefully matched to the Planning and installation instructions
capacity of the burner. Suitable connection types for medium oil Air /Gas separator, circulation tank,
preheaters can be selected, depending pump station and oil preheater station
Scope of delivery - preheater stations on the medium available. If medium oil must be installed close to the burner as
Preheater stations are supplied fully preheaters are provided without electric possible.
assembled on an oil drip tray. The oil preheaters, a mechanical temperature
preheater ensures a constant oil regulator must be used with the medium On RGMS type burners, sizes 60 and
temperature and as result, the connection fittings. 70, the time required for oil circulation
appropriate viscosity of the fuel oil. during start sequence depends on the
Air / gas separators or oil circulation length of the pipework between the
There are two basic versions of the tanks burner and the air gas separator or
preheater station available: Patented air / gas separators or circulation tank.
circulation tanks are always required and
1. Electric preheating (model WEV...) must be quoted with the burner. The shorter the pipeline, the shorter the
2. Medium preheating (model MV...) period between call for heat and oil
By using an air / gas separator or release / burner start after a controlled
MV.. medium oil preheater circulation tank, it is possible for the shutdown.
Medium preheaters are high capacity, preheated oil from the burner return to be
forced circulation heat exchangers. High mixed with oil from the burner supply line.
capacity is achieved with a compact, This results in an energy saving, as it is
space saving construction. Hot water, only necessary to partially heat the fuel
steam or thermo fluid can be used as oil.
heating medium. The oil preheaters
guarantee substantially stable oil Where one burner is operating on light
temperatures and thus good combustion oil, it is then possible to use a two pipe
figures. The oil temperature achieved system so long as the suction vacuum
depends on the heating medium used. does not exceed 6 PSI (0.5 bar). If
several burners with air / gas separators
When selecting and sizing, please refer or oil circulation tanks are being supplied
to the oil temperature diagrams in by a ring main system, then it is a good
chapter 5.3 of the technical brochure idea to provide a manually actuated
“Weishaupt electric and medium oil double shut off device with limit switch
preheaters”, print No. 18. Weishaupt immediately after the air / gas separator
medium oil preheaters can be used or circulation tank. The air / gas
universally. It is possible to change the separator or circulation tank must be
medium at any time. The medium selected according to the ring main
preheater can be used either as stand pump rating and the burner size. When
alone unit or in conjunction with an choosing ring main pump units, please
electric oil preheater. ensure that the capacity is around 1.5 - 2
times of the nozzle rating.

18
Pump and preheater stations
Types

Pump stations - 60 Hz frequency


Burner Technical data - pump Version with 1 pump Version with 2 pumps
capacity Supply at Speed Motor at Pump type Order No. Pump type Order No.
in GPH 150 mm2/s rpm 450 mm2/s
GPH (l/h) HP (kW)
74 – 115 270 (1020) 3400 3 (2.2) SPF 10-38 170 003 09 SPZ 10-38 170 003 11
115 – 215 540 (2050) 3400 3.5 (2.6) SPF 20-38 170 003 10 SPZ 20-38 170 003 12
215 – 265 720 (2720) 3400 5.3 (4.0) SPF 20-46 170 003 13 SPZ 20-46 170 003 14
Preheater stations
Type Number Medium preheater Electric preheater Order No.
lbs/h (kg/h) at ∆t = 135F (75°C)
WEV3.1/01 1 – 100 GPH (375 kg/h) 170 003 55
WEV3.1/01 2 – 200 GPH (750 kg/h) 170 003 52
WEV3/01 1 – 133 GPH (500 kg/h) 170 002 23
WEV3/01 2 – 266 GPH (1000 kg/h) 170 002 24
MV9C with temperature contr. 1 1100 (500) – 170 001 03
MV9C without temperature contr. 1 1100 (500) – 170 001 04
MV10A with temperature contr. 1 2200 (1000) – 170 000 94
MV10A without temperature contr. 1 2200 (1000) – 170 002 30
Connection fittings for preheater stations with 1 oil preheater
Description Order No.
Fittings for MV9C medium preheater station (with electric preheater stations)
– screwed for warm water up to 230F (110°C) 120 001 70
– screwed for high pressure steam up to 21.75PSI (1.5 bar) 170 003 59
– screwed for high pressure steam from 21.75PSI (1.5 bar) up to 217.5PSI (15 bar) 170 003 60
– flanged for warm water up to 230F (110°C) 120 001 78
– flanged for hot water from 230F (110°C) up to 355F (180°C) 120 001 79
– flanged for high pressure steam up to 21.75PSI (1.5 bar) 170 003 61
– flanged for high pressure steam from 87PSI (6 bar) up to 290PSI (20 bar) 170 003 62
– flanged for high pressure steam from 290PSI (20 bar) up to 363PSI (25 bar) 170 003 67
– flanged for thermal fluid up to 480F (250°C) 120 001 75
– flanged for thermal fluid up to 570F (300°C) 120 001 77
Fittings for MV9C medium preheater station (with thermostat valve. without electric preheater)
– flanged for hot water from 355F (180°C) up to 390F (200°C) 120 001 81
– flanged for high pressure steam from 109PSI (7.5 bar) up to 188.5PSI (13 bar) 170 003 63
– flanged for high pressure steam from 188.5PSI (13 bar) up to 290PSI (20 bar) 170 003 64
– flanged for high pressure steam from 290PSI (20 bar) up to 363PSI (25 bar) 170 003 65
– flanged for thermal fluid from 390F (200°C) up to 480F (250°C) 120 001 84
– flanged for thermal fluid from 480F (250°C) up to 570F (300°C) 120 001 85
Fittings for MV10A medium preheater station (with electric preheater stations)
– screwed for warm water up to 230F (110°C) 170 001 35
– screwed for high pressure steam up to 21.75PSI (1.5 bar) 170 001 47
– screwed for high pressure steam from 21.75PSI (1.5 bar) up to 217.5PSI (15 bar) 170 001 53
– flanged for warm water up to 230F (110°C) 170 001 38
– flanged for hot water from 230F (110°C) up to 355F (180°C) 170 001 44
– flanged for high pressure steam up to 21.75PSI (1.5 bar) 170 001 50
– flanged for high pressure steam from 87PSI (6 bar) up to 290PSI (20 bar) 170 001 56
– flanged for high pressure steam from 290PSI (20 bar) up to 363PSI (25 bar) 170 002 00
– flanged for thermal fluid up to 480F (250°C) 170 001 59
– flanged for thermal fluid up to 570F (300°C) 170 001 62
Fittings for MV10A medium preheater station (with thermostat valve, without electric preheater)
– flanged for hot water from 355F (180°C) up to 390F (200°C) 170 001 68
– flanged for high pressure steam from 109PSI (7.5 bar) up to 188.5PSI (13 bar) 170 001 71
– flanged for high pressure steam from 188.5PSI (13 bar) up to 290PSI (20 bar) 170 001 74
– flanged for high pressure steam from 290PSI (20 bar) up to 363PSI (25 bar) 170 001 85
– flanged for thermal fluid from 390F (200°C) up to 480F (250°C) 170 001 77
– flanged for thermal fluid from 480F (250°C) up to 570F (300°C) 170 001 80

19
Pump and preheater stations
Connection fittings

Pump station (with 2 pumps) Medium preheater station Electric preheater station

Possible connections of medium


preheater

HW outlet

HW inlet
Medium Electric
Hot water preheater preheater

HW outlet
Thermo fluid outlet Brenner-
Anschluß

HW inlet Mechanically connected shut off


Thermo fluid inlet assembly with limit switch and
Hot water and thermo fluid safety valve
Mechanically
connected
shut off
Condensate outlet assembly
with limit
switch and
safety valve
Description
Steam inlet The connection fittings are to be
Low pressure steam up to 22PSI (1.5 bar) Air/gas separator chosen depending on the available
medium and the number of preheaters.
Condensate outlet
Included with pump station Preheater (not included Condensate sight glass
in delivery)
Included with preheater Steam trap
Accessories Ball valve Filter
HPS inlet
Lines shown in black to be Regulator Pressure gauge
High pressure steam up to 217.5PSI (15 bar) provided on site

Diagram - separate pump and preheater stations

20
Dimensions
Sizes 30 and 40

Size Dimensions in inches (mm)


l1 l2 l3 l5 l6 l7 l8 l9 l10 l11 l12 l13 b1 b2 b3 b4
30/2-A 42.6 9.6 10.7 0.3 13.9 11.8 2.3 9.4 4.8 1.3 12.1 7.7 35.2 14.6 8.2 27.6
(1083) (245) (272) (8) (354) (300) (58) (238) (123) (32) (308) (195) (895) (371) (208) (700)
40/1-B 44.4 10.6 10.7 0.3 16.3 12.6 2.3 9.4 4.8 1.3 12.9 7.7 37.4 15.8 9.5 29.7
(1128) (270) (272) (8) (414) (320) (58) (238) (123) (32) (328) (195) (950) (401) (242) (755)
40/2-A 45.2 10.6 13.1 0.3 16.3 13.4 2.6 10.2 5.2 1.7 13.7 7.7 37.4 15.8 9.5 29.7
(1148) (270) (332) (8) (414) (340) (67) (258) (133) (42) (348) (195) (950) (401) (242) (755)
b5 b6 h1 h2 h3 h4 h5 h6 d1 d2 d4 d5 d6 d7 d8➀ r1➂ r2
30/2-A 16.5 13.0 22.5 8.1 16.0 8.1 8.3 13.0 11.0 9.8 8.6 14.2 11.2 38.2 35.0
(418) (330) (572) (207) (407) (207) (210) (330) (280) (250) (218) M12 (360) (285) DN50 (970) (890)
40/1-B 18.2 13.0 23.9 8.3 16.6 8.1 8.3 13.0 11.0 9.8 8.6 14.2 11.2 41.3 38.2
(462) (330) (607) (211) (422) (207) (210) (330) (280) (250) (218) M12 (360) (285) DN50 (1050) (970)
40/2-A 18.2 14.6 23.9 8.3 16.6 8.9 8.3 14.6 12.6 11.4 8.6 15.7 12.8 41.3 38.2
(462) (370) (607) (211) (422) (227) (210) (370) (320) (290) (218) M12 (400) (325) DN65 (1050) (970)

➀ Gas butterfly valve with flange connection


➁ Pilot line connection either side
➂ With electromagnetic clutch

All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments.

21
Dimensions
Size 50

Size Dimensions in inches (mm)


l1 l2 l3 l5 l6 l7 l8 l9 l10 l11 l12 l13 b1 b2 b3 b4 b5
50/1-B 47.0 12.4 13.1 0.3 16.6 14.3 2.6 10.2 5.2 1.7 14.5 10.0 41.7 17.3 10.9 32.3 21.7
(1195) (315) (332) (8) (422) (363) (67) (258) (133) (42) (368) (254) (1060) (440) (277) (820) (550)
50/2-A 49.0 12.4 13.1 0.3 16.6 16.3 2.8 12.1 6.2 2.6 15.3 12.4 43.3 18.3 10.9 33.9 21.7
(1245) (315) (332) (8) (422) (413) (72) (308) (158) (65) (388) (314) (1100) (465) (277) (860) (550)
b6 h1 h2 h3 h4 h5 h6 d1 d2 d4 d5 d6 d7 d8➀ r1➂ r2
50/1-B 14.6 28.7 10.4 20.2 8.9 7.2 14.6 12.6 11.4 10.2 15.7 12.8 46.5 39.4
(370) (730) (263) (513) (227) (183) (370) (320) (290) (258) M12 (400) (325) DN65 (1180) (1000)
50/2-A 16.9 28.7 10.4 20.2 10.1 7.8 16.9 15.0 13.8 10.2 18.9 15.4 46.5 40.4
(430) (730) (263) (513) (257) (197) (430) (380) (350) (258) M16 (480) (390) DN80 (1180) (1025)

➀ Gas butterfly valve with flange connection


➁ Pilot line connection either side
➂ With electromagnetic clutch

All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments.

22
Dimensions
Sizes 60 and 70

d5

d7
d6

Size Dimensions in inches (mm)


l1 l2 l3 l5 l6 l7 l8 l9 l10 l11 b1 b2 b3 b4 b5 b6
60/2-A 58.2 15.9 14.1 0.3 20.7 17.5 3.5 13.7 7.0 3.3 47.8 19.2 11.0 38.0 26.4 20.5
(1478) (405) (357) (8) (520) (440) (89) (348) (178) (85) (1215) (487) (280) (966) (670) (520)
70/1-B 64.6 19.9 14.1 0.3 24.2 20.1 3.5 13.7 7.0 3.4 55.5 23.7 13.4 44.3 29.9 20.5
(1640) (485) (357) (8) (614) (510) (89) (348) (178) (85) (1410) (602) (340) (1125) (760) (520)
70/2-A 65.4 19.9 14.3 0.3 24.2 20.9 4.0 14.5 7.4 3.4 55.5 23.7 13.4 44.3 29.9 23.6
(1660) (485) (362) (8) (614) (530) (102) (368) (188) (87) (1410) (602) (340) (1125) (760) (600)
h1 h2 h3 h4 h5 d1 d2 d4 d5 d6 d7 d8➀ r1➁ r2
60/2-A 36.6 14.2 26.4 11.9 20.5 17.0 15.7 10.2 18.5 17.1 53.1 44.9
(930) (360) (670) (302) (520) (432) (400) (258) M16 (470) (435) DN100 (1350) (1140)
70/1-B 42.3 16.5 30.5 11.9 20.5 17.0 15.7 12.2 18.5 17.1 59.1 51.6
(1075) (420) (775) (302) (520) (432) (400) (310) M16 (470) (435) DN100 (1500) (1310)
70/2-A 42.3 16.5 30.5 12.4 23.6 18.5 18.9 12.2 21.7 19.7 59.1 51.6
(1075) (420) (775) (315) (600) (470) (480) (310) M16 (550) (500) DN100 (1500) (1310)

➀ Gas butterfly valve with flange connection


➁ Pilot line connection either side
➂ With electromagnetic clutch

All measurements are approximate. Weishaupt reserves the right to make alterations in light of future developments.

23
Product and customer service Weishaupt Corporation
6280 Danville Road
Mississauga, ON L5T 2H7

the complete Weishaupt range Ph.: (905) 564 0946, Fax.: (905) 564 0949
www.weishaupt-corp.com

Print No. 83201316, October 2008


Printed in Germany. All rights reserved.

Regular maintenance reduces heating Weishaupt customer service is there for


costs and environmental pollution. Only a you all year round. Whenever you need
properly adjusted burner can save energy help, be it the supply of spare parts,
and be environmentally friendly. Behind technical advice or a site visit. We are
each Weishaupt burner stands the whole there when you need us.
Weishaupt customer service organization.
The outstanding efforts made in
maintenance and service justify the
enormous trust placed in Weishaupt’s
burners, for at Weishaupt product and
customer service belong together.