RecurDyn is integrated multi-discipline dynamics CAE software based on MFBD (Multi-Flexible Body Dynamics). RecurDyn consists of
RecurDyn/Professional and Toolkits. The Toolkits are divided between Interdisciplinary, Communicator, and Application Toolkits.
Contents
FLOW CHART FOR USING INSTALLATION GUIDE ............................................................................ 5
CHAPTER 1 - GETTING STARTED.............................................................................................. 6
ROADMAP FOR USING THIS MANUAL .......................................................................................................6
WHAT YOU NEED ...................................................................................................................................6
INSTALLATION PROCESS..........................................................................................................................8
GETTING HELP ........................................................................................................................................9
CHAPTER 2 - UPGRADING RECURDYN ..................................................................................... 10
THE VERSION NUMBERS ........................................................................................................................10
INSTALLING THE MULTIPLE VERSIONS ...................................................................................................10
INSTALLING THE SERVICE PACK VERSION ..............................................................................................10
UPGRADING THE RECURDYN LICENSE SERVER ......................................................................................10
CHAPTER 3 – CHECKING PRE-REQUIREMENTS ........................................................................... 12
CHAPTER 4 - INSTALLING FUNCTIONBAY LICENSE SERVER ............................................................ 17
SOLVING PROBLEM ................................................................................................................................21
LICENSING CONTROL TO AUTOMATIC CHECK-IN FUNCTION...............................................................25
CHAPTER 5 - INSTALLING RECURDYN ..................................................................................... 27
STARTING THE INSTALLATION...............................................................................................................27
PREPARING TO LAUNCH THE INSTALLSHIELD ........................................................................................28
LICENSING, REQUIREMENTS, INFORMATION ..........................................................................................29
INSTALLING THE FILES ...........................................................................................................................32
RESULTS OF THE INSTALLATION ............................................................................................................42
REGISTRATION OF LICENSES..................................................................................................................43
INSTALL WITHOUT .NET 3.5 ................................................................................................................47
SILENT INSTALL.....................................................................................................................................48
SILENT UNINSTALL ................................................................................................................................49
CHAPTER 6 - CONFIGURING RECURDYN NETWORK SERVER .......................................................... 50
RUNNING RECURDYN ON NETWORK CLIENT ........................................................................................56
MODIFYING SETTINGS ON NETWORK CLIENT........................................................................................57
CHAPTER 7 - CONFIGURING RECURDYN LINUX NETWORK SERVER .................................................. 59
RUNNING RECURDYN ON NETWORK CLIENT ........................................................................................68
MODIFYING SETTINGS ON NETWORK CLIENT........................................................................................69
CHAPTER 8 - USING THREE-SERVER REDUNDANCY..................................................................... 71
STEP TO INSTALL THE REDUNDANT LICENSE........................................................................................72
CHAPTER 9 - FINISHING TOUCHES.......................................................................................... 74
PROCESSNET INITIALIZATION ................................................................................................................74
CHECKING WINDOWS FIREWALL ............................................................................................................76
CHAPTER 10 - SETTING TOOL .............................................................................................. 77
WHEN TO USE .......................................................................................................................................77
INITIALIZATION PROBLEMS ....................................................................................................................78
REGISTRATION PROBLEMS .....................................................................................................................79
PROCESSNET PROBLEMS .......................................................................................................................80
Copyright © 2021 FunctionBay, Inc. All rights reserved
User and training documentation from FunctionBay, Inc. is subjected to the copyright laws of the Republic of
Korea and other countries and is provided under a license agreement that restricts copying, disclosure, and
use of such documentation. FunctionBay, Inc. hereby grants to the licensed user the right to make copies in
printed form of this documentation if provided on software media, but only for internal/personal use and in
accordance with the license agreement under which the applicable software is licensed. Any copy made shall
include the
FunctionBay, Inc. copyright notice and any other proprietary notice provided by FunctionBay, Inc. This
documentation may not be disclosed, transferred, modified, or reduced to any form, including electronic
media, or transmitted or made publicly available by any means without the prior written consent of
FunctionBay, Inc. and no authorization is granted to make copies for such purpose.
Information described herein is furnished for general information only, is subjected to change without notice,
and should not be construed as a warranty or commitment by FunctionBay, Inc. FunctionBay, Inc. assumes no
responsibility or liability for any errors or inaccuracies that may appear in this document.
The software described in this document is provided under written license agreement, contains valuable trade
secrets and proprietary information, and is protected by the copyright laws of the Republic of Korea and other
countries. UNAUTHORIZED USE OF SOFTWARE OR ITS DOCUMENTATION CAN RESULT IN CIVIL DAMAGES AND
CRIMINAL PROSECUTION.
Edition Note
This document describes the installation procedures of RecurDyn V9R5.
Revision History
First printed, August 2021
FLOW CHART FOR USING INSTALLATION GUIDE
Chapter 3
Chapter 6
Chapter 5
Distribute RecurDyn
NetworkClient.bat
Automatically setting
Run RecurDyn
and running RecurDyn
On Client Computer
There are two processes for installing RecurDyn as General or RecurDyn Server Client.
They are decided by license type. To see more each chapter’s roadmap in the above flow
chart, refer to Roadmap for using this manual section of Chapter1.
5
GETTING STARTED
◼ HARDWARE REQUIREMENTS
⚫ 64-bit
Minimum Recommended
CPU 2.4GHz 3.4GHz, Quad Core
Memory (RAM) 8GB 32GB
Free Disk Space 10GB 1TB
Display Adapter OpenGL OpenGL 4.0
Screen Resolution 1024*768 1920*1080
ODD DVD-R (DL) or above
6
GETTING STARTED
• RecurDyn only supports 100% size of apps and text on the display.
Please check that your computer meets the hardware and OS requirements.
Note: The system requirements above are for FlexNet 11.14.0. The
system requirements for other versions of FlexNet related to the
RecurDyn License server are as follows.
- 11.15.0
Process Type Operating System
Microsoft Windows Windows Server 2008
X86
32-bit
Windows 10
Windows Server 2016
Windows Server 2012 R2
Microsoft Windows
X64 Windows Server 2012
64-bit
Windows Server 2008
Windows 8.1
Windows 7 SP1
7
GETTING STARTED
INSTALLATION PROCESS
1. Send a Purchase Order to your RecurDyn sales representative.
2. Send your computer hardware information to your RecurDyn sales
representative.
3. Receive a RecurDyn DVD and RecurDyn license file.
8
GETTING STARTED
GETTING HELP
If you have questions or problems installing RecurDyn, review the contents of this
model. For additional help, contact your local FunctionBay representative.
9
GETTING STARTED
10
GETTING STARTED
in that release. The existing license server will not recognize the request for the new
module type.
If users have further questions as to whether they need to upgrade the license server,
they can contact their local RecurDyn support organization or distributor.
Note: Before uninstalling the existing license server, a backup can be made of the
current license file which resides in the license server’s installation directory (usually
“C:\Program Files\FunctionBay, Inc\FunctionBay License Server”). Then during
installation of the new license server, the user can easily locate the license file.
11
CHECKING PRE-REQUIREMENTS
12
CHECKING PRE-REQUIREMENTS
2. The Check Pre-Requirements dialog is shown up, the user can figure out what
programs are required to install RecurDyn.
If some requirements are not checked, press Install button to setup the programs. Then
the installation processes will be executed one by one.
Note2: This rarely happens, but ribbon menu icons can be inactive because VS2015
Redistributable x64 was not installed correctly. It is recommended to reinstall the
VS2015 Redistributable x64 again to fix the issue.
13
CHECKING PRE-REQUIREMENTS
Note3: Problem might occur when installing .NET Framework 3.5 with exe file. It might
not be installed in Windows 10. To install the .NET Framework 3.5, follow the below
processes. Internet connection is necessary in this process.
2. Check .NET Framework 3.5 (include .NET 2.0 and 3.0), select OK, and reboot
your computer if prompted.
14
CHECKING PRE-REQUIREMENTS
Note4: To install .NET Framework 3.5 follow the below process. You need Windows
Installation Media such as DVD, ISO image or USB.
1. Insert the Windows Installation DVD, or double-click your ISO image, or insert
USB drive, according to what you have.
2. Open 'This PC' and note the drive letter of the Windows installation media.
15
CHECKING PRE-REQUIREMENTS
3. Open Command Prompt as Admin (Press Win + X and click Command Prompt
(Admin)) and type the following command:
Be sure to replace the Y with the drive letter of the Installation media.
Dism /online /enable-feature /featurename:NetFX3 /All /Source:Y:\sources\sxs
/LimitAccess
Note5: From V9R5 version, users using DriveTrain toolkit must have the Window Media
Feature Pack installed on their computer. This has been added as a Requirement in the
2020 version of KISSsoft. You can download it with link below:
https://www.microsoft.com/en-us/software-download/mediafeaturepack
16
INSTALLING FUNCTIONBAY LICENSE SERVER
1. The Install License Server is installed using the option from the RecurDyn DVD
Installation screen as shown in the figure.
17
INSTALLING FUNCTIONBAY LICENSE SERVER
2. The Destination Location for the FunctionBay license server must be defined. The
default location is typical for a Windows application.
18
INSTALLING FUNCTIONBAY LICENSE SERVER
5. A browser window appears. The location of the RecurDyn license file that was
provided by the local RecurDyn sales representative should be set.
6. The License Server files will be copied to the installation directory. If you want to
stop the FunctionBay License Server installation, click the Cancel button.
19
INSTALLING FUNCTIONBAY LICENSE SERVER
8. The Licenser Server software should be running now. You can go to the Program
Folder of the FunctionBay License Server (accessed from the Start button, then
selecting All Programs) and run the FLEXlm Utility in order to check the status of
the License Server.
9. The FLEXlm Utility provides capabilities to start and stop the License Server, as well
as perform diagnostics. The FLEXlm End Users Guide provides valuable information
about the License Server.
Note: Using the license server version offered with the RecurDyn version is required.
20
INSTALLING RECURDYN
◼ If you use the previous license server version, it might have some problems to
confirm the RecurDyn license.
SOLVING PROBLEM
FlexNet Version v11.14.0 is required. From v11.13.1, the logon user of the service
created via lmtools.exe has been changed from LOCAL SYSTEM to LOCAL SERVICE.
Please refer to following contents copied from FlexNet Publisher v11.13.1 Release
Notes.
❖ If it takes a long time to start the license server and the below message is shown at
the bottom of the Start / Stop / Reread tab, the license server is not started
correctly.
– “VD is starting, please check vendor daemon's status in debug log”.
21
INSTALLING RECURDYN
3) Below the Service/License File tab in LMTOOLS, there is option “LMTOOLS ignores
license file path environment variables”. Make sure to click it and try to restart the
service
4) Or, change the user account that the service can use to log on as Local System
account.
② Click Start, click in the Start Search box, type services.msc, and then press
22
INSTALLING RECURDYN
ENTER.
③ In Services window select License Manager Service > right-click and select
Properties
23
INSTALLING RECURDYN
❖ It will take a long time to start the service automatically when a computer is
started. Because the default Startup type is changed to Automatic (Delayed
Start) since FlexNet Version v11.13.1 as the following figure. If you want to
set the previous type, please change the Startup type as Automatic manually.
24
INSTALLING RECURDYN
❖ The default port number in the license file supported from FunctionBay is 11800. If
other services are stopped by starting FunctionBay License Server, they maybe use
same port number. In order to resolve it, we recommend specifying port number in
the SERVER line for FunctionBay License Server.
Since V9R1, FlexNet Version v11.14.0 is officially used. Later versions are additionally
distributed in the install directory. FunctionBay supports up to FlexNet Version
v11.16.5.1. FlexNet install path is as follows.
✓ 11.14.0
<Install Package >\FunctionBay LicenseServer\11.14.0\
✓ 11.15.0
< Install Package >\FunctionBay LicenseServer\11.15.0\
✓ 11.16.0
< Install Package >\FunctionBay LicenseServer\11.16.0\
✓ 11.16.5.1
< Install Package >\FunctionBay LicenseServer\11.16.5.1\
✓ 11.17.2.0
< Install Package >\FunctionBay LicenseServer\11.17.2.0\
25
INSTALLING RECURDYN
This function can be activated by setting the system environment variable. Setting the
'FBLMD_AUTO_CHECK_IN_MAXIMUM_TIME_MINUTE' variable as shown below will
activate the function.
If the function is successfully activated, you can check the log window as shown
below.
The function is set up in minutes, and if the value is less than 0, the function is
deactivated.
26
INSTALLING RECURDYN
2. Insert the RecurDyn DVD into your DVD-ROM drive. The RecurDyn installation
program should automatically begin to run, bring up the window shown in the
figure.
27
INSTALLING RECURDYN
2. Notification is given that the InstallShield wizard is being prepared. The window will
put itself away after the wizard preparation is complete.
28
INSTALLING RECURDYN
2. The Next button will no longer be grayed out. Click the Next button to continue.
29
INSTALLING RECURDYN
3. The computer hardware and software system requirements are presented. This
information is also provided in Chapter 1 of this manual.
30
INSTALLING RECURDYN
31
INSTALLING RECURDYN
32
INSTALLING RECURDYN
4. The RecurDyn installation offers two setup types. To use the Complete type which is
the default is recommended to user. Click Next to accept the setup type.
33
INSTALLING RECURDYN
5. Program Folder can be customized. This is the folder that RecurDyn appears in,
under the All Programs list. Click Next to accept the Program Folder.
34
INSTALLING RECURDYN
6. The RecurDyn files will be installed. A status bar will show the progress. The window
is put away when all of the files are loaded.
7. Note that the installation window for pre-requirement softwares will appear as
shown in the figure.
35
INSTALLING RECURDYN
Note2: When RecurDyn is installed with the keyword of this function set to False, the
following functions cannot be used.
◼ ProcessNet using VSTA
◼ MEHD
◼ TNO
Note3: This function is available only when the full version is installed.
36
INSTALLING RECURDYN
8. A new window will appear when all files are installed. Click the Finish button to
acknowledge the completion of the file installation.
9. After finishing the installation, RecurDyn License Manager will appear. Refer to
Registration of License.
37
INSTALLING RECURDYN
Note: At the end of the installation, RecurDyn License Manager window opens for your
convenience. However, some users do not need to do this. A Install_Preference.dat file
has been added to the packaging file to assist these users. (This file can be opened
using a text editor.)
In this file, there is a line "License Manager Execution Automatically = True". In this line,
you cannot open RecurDyn License Manager window from opening by changing the True
keyword to False as follows:
◼ License Manager Execution Automatically = False
38
INSTALLING RECURDYN
◼ Modify: Install the selected Feature, uninstall the unselected Feature and no
changes if the feature selection status is same as the installation.
◼ Repair: Reinstall the Features that were selected during the installation.
◼ Remove: Uninstall the all installed Features.
Note2: At the end of the installation, There is a function to execute the batch file
defined by the user. Define the file as *.bat file format as user want. And after define the
file according to the syntax of the window batch command, put it in the location where
setup.exe is located. The batch file will be executed after the installation is finished.
Example
We will copy and paste some files and folder into the install location. The folders and
files to be copied are shown in the figure below.
39
INSTALLING RECURDYN
In the preceding figure, ProgramSettings.xml is an existing file and the file has the path
of online help. We change the html path like bellow figures for testing.
◼ XML file is defined as below. Change the path of Official online help for testing.
◼ Move this file to the location where setup.exe is and define the batch file.
40
INSTALLING RECURDYN
41
INSTALLING RECURDYN
Tip: If the RecurDyn icon appears as a generic icon, place the cursor in the
background of the installation window, click the right mouse button and select
Refresh from the pop-up menu.
42
INSTALLING RECURDYN
REGISTRATION OF LICENSES
To register licenses, you can use a license file by selecting one of two types as On
Premise or Cloud.
◼ On Premise is to run RecurDyn when a license file enables a License Server
43
INSTALLING RECURDYN
somewhere on the network. So, you should install FunctionBay License Server on
the License Server computer before registering the license.
◼ Cloud is that a set of valid user ID and password is needed. In this case, Internet
should be connected and there is no need to install any local license server for
connection. This service is available only for users who contracted Cloud license
server service with official RecurDyn dealers. For more information, please
contact RecurDyn dealers through (https://functionbay.com/en/contact-form).
1. You can access the RecurDyn License Manager from the Windows Start menu from
the FunctionBay folder.
Note:
o If you log in using a Standard User account (not an administrator account),
then the RecurDyn License Manager must be run using standard user
privileges. In other words, do not run the RecurDyn License Manager using
Administrator Privileges. The RecurDyn License Manager requires the same
privilege level as the account that will be used to run RecurDyn.
2. The RecurDyn License Manager window appears.
On Premise
a. Click Add button to add a row to the table.
b. Enter the License Server name in the License column when the using a Floating
License.
c. Click OK button in the RecurDyn License Manager window.
Note: Multiple license servers can be registered. However, regardless of the order
in which they are registered, the license is obtained first from the server where
the connection was successful before. If you want the licenses to be imported in
44
INSTALLING RECURDYN
Cloud
a. Enter the ID and Password.
b. Click OK button in the RecurDyn License Manager window.
3. An alert box appears to indicate that the license was registered successfully.
4. In RecurDyn License Manager, you can set the license for 3rd party supported in
RecurDyn.
45
INSTALLING RECURDYN
When you register with the Floating License, you must make sure that you
have used the correct License Server name and the License Server is
operating properly before you execute RecurDyn.
If the server or your network is not operating properly, you will see an error
message. You then click the Cancel button, make sure the server and
network are operating correctly, and restart RecurDyn.
◼ The environment variable is set in User Variable. So, RecurDyn License Manager
should be executed for each user account.
◼ If you want the license information to be shared for all users, delete the
information in the User Variable and enter the environment variable in the
System Variable.
46
INSTALLING RECURDYN
1. Without .NET 3.5, in the start of installation, you will be given the warning dialog as
below. To install RecurDyn without .NET 3.5, click ‘No’.
3. Click ‘Yes’ to install without .NET 3.5. Keep in mind that you cannot use ProcessNet
(VSTA) in this case.
47
INSTALLING RECURDYN
SILENT INSTALL
Silent installations are installations that run without an end-user interface. If you want
your installation to run silently, follow the below process.
2. Open the Install_Preference.dat file and change the value of License Manager
Execution Automatically to False
4. Execute setup.exe file with command-line argument ‘-s’. You can make shortcut of
setup.exe file and add ‘-s’ at the end of Target Path.
5. After Silent Install, you may have to register the license information manually at
48
INSTALLING RECURDYN
Note
You can use silent install without changing the file name of iss file with custom
command-line below.
Setup.exe /s /f1"C:\Temp\Setup_install.iss"
(Path of iss file should be changed to correct value.)
SILENT UNINSTALL
1. Change the name of the file setup_uninstall.iss to setup.iss.
3. After Silent Uninstall, it may be required to restart the computer to complete the
uninstallation process.
Note
You can use silent install without changing the file name of iss file with custom
command-line below.
Setup.exe /s /f1"C:\Temp\Setup_uninstall.iss"
(Path of iss file should be changed to correct value.)
49
CONFIGURING RECURDYN NETWORK SERVER
Before starting this step, you should install RecurDyn on the Network Server
computer.
2. Insert the RecurDyn DVD into your DVD-ROM drive. The RecurDyn installation
program should automatically begin to run, bring up the window shown in the
figure.
50
CONFIGURING RECURDYN NETWORK SERVER
51
CONFIGURING RECURDYN NETWORK SERVER
52
CONFIGURING RECURDYN NETWORK SERVER
53
CONFIGURING RECURDYN NETWORK SERVER
54
CONFIGURING RECURDYN NETWORK SERVER
• Load
Load the toolkit related DLLs when the RecurDyn starts.
The License Control displays the Toolkit License. User can turn the license ON / OFF.
• Check
Load the toolkit related License when the RecurDyn starts.
The License Control did not display the Toolkit License. User cannot turn the license ON /
OFF.
8. The RecurDynNetworkClient.bat file will be created as shown in the figure. This file
is located in the following file path:
C:/Program Files/FunctionBay, Inc/<RecurDyn
Version>/NetworkServer/NetworkClient
55
CONFIGURING RECURDYN NETWORK SERVER
3. After installing the pre-requirement software, the batch file will set the registry
key about RecurDyn, License and VSTA configuration.
56
CONFIGURING RECURDYN NETWORK SERVER
57
CONFIGURING RECURDYN NETWORK SERVER
58
CONFIGURING RECURDYN LINUX NETWORK SERVER
There are some preparations before starting this step. There should be Linux
Network Server and Installer Computer. Installer Computer is used for
configuring the RecurDyn on the Linux Network Server. You should install
RecurDyn on Installer Computer before starting this step. Also, Installer
Computer should be able to access the target folder of Network Server where
RecurDyn should be installed.
2. Insert the RecurDyn DVD into your DVD-ROM drive. The RecurDyn installation
program should automatically begin to run, bring up the window shown in the
figure.
59
CONFIGURING RECURDYN LINUX NETWORK SERVER
60
CONFIGURING RECURDYN LINUX NETWORK SERVER
61
CONFIGURING RECURDYN LINUX NETWORK SERVER
6. Enter the Linux Host PC Name, RecurDyn Folder Name, Common Folder Name in the
following dialog box.
7. Click OK if the following folders are shared, accessible and are where RecurDyn is to
be installed.
62
CONFIGURING RECURDYN LINUX NETWORK SERVER
63
CONFIGURING RECURDYN LINUX NETWORK SERVER
64
CONFIGURING RECURDYN LINUX NETWORK SERVER
65
CONFIGURING RECURDYN LINUX NETWORK SERVER
• Load
Load the toolkit related DLLs when the RecurDyn starts.
The License Control displays the Toolkit License. User can turn the license ON / OFF.
• Check
Load the toolkit related License when the RecurDyn starts.
The License Control did not display the Toolkit License. User can not turn the license ON
/ OFF.
11. After installer creates necessary batch files, it copies the RecurDyn and Common
folder to the user designated shared folder from Step 5. It copies the RecurDyn
folder which is 7GB+. Therefore, it might take several minutes,
12. The RecurDynNetworkClient.bat file will be created as shown in the figure. This file
is located in the following file path :
<Installer Computer InstallDir>\NetworkServer/NetworkClient
<Network Server InstallDir>\NetworkServer/NetworkClient
66
CONFIGURING RECURDYN LINUX NETWORK SERVER
67
CONFIGURING RECURDYN LINUX NETWORK SERVER
3. After installing the pre-requirement software, the batch file will set the registry
key about RecurDyn, License and VSTA configuration.
68
CONFIGURING RECURDYN LINUX NETWORK SERVER
69
CONFIGURING RECURDYN LINUX NETWORK SERVER
70
USING THREE-SERVER REDUNDANCY
71
USING THREE-SERVER REDUNDANCY
The user should input the port number in the license file before setting up the
redundant license. The following is an example of the license file configured for three-
server redundancy.
And the user should enter the three servers installed in the RecurDyn License Manager
window as the right example.
72
USING THREE-SERVER REDUNDANCY
If the installation of the redundant license is failed, please check the Windows Firewall
in Control Panel. (Start->Settings->Control Panel->Windows Firewall) or (Start-
>Settings->Control Panel->Security Center->Windows Firewall)
1. Make sure the radio button and select the Off option.
2. Press the Browse button.
3. Find the FunctionBay License Server folder.
4. Add ‘fblmd.exe’ and ‘lmgrd.exe’
5. Click the OK button.
73
FINISHING TOUCHES
3. A new window appears with the heading ProcessNet – RecurDyn, as shown below.
74
FINISHING TOUCHES
4. RecurDyn is now ready to for use with account without administrative privileges as
well as with administrative privileges.
Note
If the following error message appears, re-installing the VSTA and Visual Studio 2015
Redistributable should fix the problems. The VSTA(Pre-Requirement
SW\vsta\vsta_aide.msi) and Visual Studio 2015 Redistributable(Pre-Requirement
SW\VS2015Redistributable) install package is in the Pre-Requirement SW folder in
Installation Disk.
75
FINISHING TOUCHES
76
SETTING TOOL
77
SETTING TOOL
INITIALIZATION PROBLEMS
You can use this option to initialize User Settings and License Information.
a. You can use this option to delete dump files which are created when
RecurDyn crashes. RecurDyn saves these dump files in User Setting folder.
b. You can use this option to initialize the location of Tool Bar and customized
layout. (In this case, you have to use it with User Settings Registry Key
option.)
78
SETTING TOOL
b. You can use this option to initialize the location of Tool Bar and customized
layout. (In this case, you must use it with User Settings Folder option.)
a. You can use this option to delete all your license information registered in
RecurDyn License Manager.
REGISTRATION PROBLEMS
You can use this option to solve registration issues by re-register some of registries
related to RecurDyn.
1. Solver
a. You can use this option when Solver is not working because Solver
registration is failed.
a. You can use this option when RecurDyn tab is disappeared in RecurDyn
Model file properties.
79
SETTING TOOL
a. You can use this option to open *.rdyn file with target version.
4. KISSsoft COM
5. CoLink
PROCESSNET PROBLEMS
You can use this option when ProcessNet related problems occur.
1. VSTA Initialize
a. You can use this option when ProcessNet is not working because information
registered to VSTA Host is not correct about RecurDyn.
80
SETTING TOOL
2. Template Project
a. You can use this option to initialize VSTA Template Project to Default state.
3. Assembly Registration
a. You can use this option when ProcessNet is not working because registration
of ProcessNet Assembly is failed
a. You can use this option to clear the VSTA project list in Run dialog. Also, you
can use this option when ProcessNet is not working with below error
message.
81
SETTING TOOL
Note
RecurDyn must be turned off for below options to work properly.
• User Settings Folder
• User Settings Registry Key
• VSTA Initialize
• Template Project
• VSTA Project List in Run Dialog
82