You are on page 1of 6

Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.

31
Date : 52023/9/
Page : 1/6

CALCULATION SHEET FOR SPIT ANCHORS


Company : Phone number :
Carried out by : Mail address :
Company : Project name :
Contact name : Location :
Phone number : Fastening point :
Mail address :

Comment :

Recommended anchors
FIX Z XTREM max. anchorage M10x90/30-10 Product Code: 057769
Effective embedment : 60 mm
ETA-15/0388 issued 2020/10/05

Base material
Concrete resistance : C25/30 - fck,cyl = 25 N/mm²
Cracking of concrete : Cracked concrete
Thickness of concrete : 200 mm
Reinforcement type : Wide concrete reinforcement
Edge reinforcement : No edge reinforcement

Conditions
Installation conditions : Dry concrete
Short term temperature : 40 °C
Long term temperature : 24 °C

Anchor plate
Thickness of part to be fixed : 10 mm
Recommended plate thickness : The base plate thickness has not been checked

Clearance diameter : 12 mm
Profile : RHS80x40x2
Profile position : Ex = 0 mm ; Ey = 0 mm
Stand-off : None

Design method : EN 1992-4 for static, quasi-static loading

Design Actions :

Action [kN] / [kNm] Action type

Combination 1 standard 2.38 0 2.25 0 0 0

Specifications :
Static
Sustained Load : False
Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.31
Date : 52023/9/
Page : 2/6

Other actions (not decisive) :

Action type Specifications


Static
Combination 2 standard -2.38 0 -2.25 0 0
Sustained Load : False

Geometry :

Calculation Hypothesis :
- The anchoring plate is assumed to be sufficient to resist deformation imposed by the load actions.
- Connection between profile and base plate has not been checked
- The calculation is done acc. to expert judgement, based on EN 1992-4

- SPIT can only be held responsible if the calculation examples exactly reflect the application and if the installation is carried out
according to the instruction given in the SPIT specifications. The calculation is correct for SPIT anchors only. The
contractor or specifier should make sure that the base material is able to support the loads especially in the case of a group of
anchors. SPIT cannot be held responsible if this software package is modified without its written approval.
Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.31
Date : 52023/9/
Page : 3/6

Resulting anchors forces

Loads on anchors

Anchor Tensile Shear[x] Shear[y]


1 1.19 kN 0 kN 1.12 kN
2 1.19 kN 0 kN 1.12 kN

2.38 1.19 0 0

2.25 1.12

Utilization

Tension load Tension force [kN] Strength [kN]


Pull out failure 1.19 6.27 19.0
Concrete cone failure 2.38 16.57 14.4
Splitting failure / / /
Steel failure 1.19 19.8 6.0

Shear load Shear force [kN] Strength [kN]


Concrete Edge failure / / /
Pryout failure 2.25 33.14 6.79
Steel failure 1.12 12.6 8.93

Combined tension and shear loads

THE APPLICATION IS SAFE


Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.31
Date : 52023/9/
Page : 4/6

CALCULATION DETAILS
Tension load - Pull out failure

Tension load - Concrete cone failure

Tension load - Splitting failure


Failure mode not decisive.
Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.31
Date : 52023/9/
Page : 5/6

Tension load - Steel failure

Shear load - Concrete edge failure


Failure mode not decisive.

Shear load - Pryout failure

Shear load - Steel failure


Ref : 5‫ ﺹ‬7:13:30 - 2023/9/ / Version 2023.03.31
Date : 52023/9/
Page : 6/6

INSTALLATION DATA

FIX Z XTREM max. anchorage M10x90/30-10


Product Code: 057769
Effective embedment : 60 mm
ETA-15/0388 issued 2020/10/05
Effective embedment : 60 mm
Minimum thickness of base material : 120 mm
Hole diameter in the base material : 10 mm
Hole depth in the base material : 75 mm
Installation torque : 45.00 Nm
Base plate thickness : 10 mm
Profile family (section type) : RHS80x40x2
Clearance diameter : 12 mm

INSTALLATION Method