The document provides information on routine maintenance, spare parts, and disposal of pump parts. It lists spare part designations and numbers for various pump components. It describes draining the pump before dismantling, checking that the shaft is not jammed before restarting, and ensuring proper sealing when reassembling. Special instructions are given for pumps with IP 55 protection to always maintain the degree of protection. The document stresses disposing of devices through specialized companies and following local regulations to protect the environment.
The document provides information on routine maintenance, spare parts, and disposal of pump parts. It lists spare part designations and numbers for various pump components. It describes draining the pump before dismantling, checking that the shaft is not jammed before restarting, and ensuring proper sealing when reassembling. Special instructions are given for pumps with IP 55 protection to always maintain the degree of protection. The document stresses disposing of devices through specialized companies and following local regulations to protect the environment.
The document provides information on routine maintenance, spare parts, and disposal of pump parts. It lists spare part designations and numbers for various pump components. It describes draining the pump before dismantling, checking that the shaft is not jammed before restarting, and ensuring proper sealing when reassembling. Special instructions are given for pumps with IP 55 protection to always maintain the degree of protection. The document stresses disposing of devices through specialized companies and following local regulations to protect the environment.
10.1. Spare-parts request OFF When ordering spare parts, please quote their efore B every maintenance operations designation, position number in the cross section disconnect the power supply and make sure drawing and rated data from the pump name plate EN that the device could not accidentally operate. (type, date and serial number). In the case of water containing chloride The spare parts request shall be sent to CALPEDA (chlorine, sea water), the risk of corrosion S.p.A. by phone, fax, e-mail. increases in stagnant water condictions (also 11. ESIGNATION OF PARTS with an increase in temperature and decrease Nr. Designation of pH value). In these cases, if the pump 14.00 Pump casing remains inactive for long periods, it must be 14.04 Plug (filling) emptied completely and, preferably, dried. 14.06 O-ring For good measure, as in the case of temporary 14.12 Plug (draining) operation with dirty liquids, run the pump 14.16 O-ring briefly with clean water to remove deposits. 14.20 O-ring When the pump remains inactive it must be 14.24 Screw emptied completely if there is a risk of freezing 14.28 Square nut (par. 12.3 fig. 5). 14.54 Wear ring (1) Before restarting the unit, check that the shaft is not 25.01 First stage casing jammed and fill the pump casing completely with liquid. 25.02 Stage casing 25.03 Stage casing with bearing (2) 8.2. Dismantling the system 25.05 Last stage casing Close the suction and delivery gate valves and drain 25.10 Washer for missing impeller the pump casing before dismantling the pump. 25.11 First stage spacer 28.00 Impeller 8.3. Dismantling the pump 28.04 Impeller nut 28.08 Washer OFF 32.00 Lantern bracket 34.00 Casing cover Close the suction and delivery gate valves and drain 34.12 Screw the pump casing before dismantling the pump (par. 36.00 Mechanical seal 12.3 fig. 5). 36.51 Retaining ring, split For dismantling and re-assembly see construction 36.52 Shoulder ring in the cross section drawing. 46.00 Deflector By removing the screws (14.24) and the square nuts 64.10 Bearing sleeve (2) (14.28 for MXH 2,4,8) the motor can be taken out 64.13 Spacer sleeve complete, with all internal parts of the pump, without 64.14 Spacer sleeve removing the pump casing (14.00) and the pipes. 64.15 Spacer sleeve 64.19 Spacer sleeve, bearing stage (2) 8.4. Pumps with IP 55 protection (Special con- 70.00 Lantern bracket struction) 70.18 Screw 70.20 Screw OFF 73.00 Pump-side bearing 76.00 Motor casing with winding To always assure IP 55 degree of protection, it is 76.04 Cable gland necessary to check the following points: 76.16 Support - Before starting the motors, carefully control the 76.54 Terminal box, set position of the gasket between terminal box and 78.00 Shaft with rotor packet its cover. For cable of small size, use a protective 81.00 Fan-side bearing covering between cable and cable gland. 82.00 Motor end shield, fan side - When disassembling the end shields of the motors, 82.04 Compensating spring restore the existing joint using the sealing glue 82.08 Screw LOCTITE type 510 or other equivalent sealing 88.00 Motor fan system, if any, and check the perfect assembly of the 88.04 Compensating spring sealing ring on the shaft. 90.00 Fan cover 90.04 Screw 9. DISPOSAL 92.00 Tie-bolt 94.00 Capacitor
OFF European Directive 94.02 Capacitor gland 2012/19/EU (WEEE) 98.00 Terminal box cover 98.04 Screw The final disposal of the device must be done by 98.08 Gasket specialized company. Make sure the specialized company follows the (1) Inserted in the stage casing classification of the material parts for the separation. (2) Only for MXH 805 Observe the local regulations and dispose the device accordingly with the international rules for environment Changes reserved. protection.