Professional Documents
Culture Documents
00%")
Text3 Actual Physical Format(IIf([Cost1]=0,0,[Cost2]/[Cost1]),"0.00%")
Text4 Schedule Financial NO FORMULA
Text5 Schedule Physical NO FORMULA
B7a/1
1
#REF!
BILL NO. 6 -
H PILING WORKS
1 H110 Provision of all necessary piling plant and equipment, sum -
transportation to the Site, handling, assembling, and
removal off the Site after completion of operation.
2 H120 Moving and handling of all piling plant and equipment sum -
within the Site and from location to location as often as is,
and whenever necessary for the execution of the whole
piling operation.
3 H241.1 Boring in earth, up to [10m] for [14] nos. of pile points for m 0 340.00 -
Vertical hole.
4 H241.2 Boring in earth, up to [11m] for [14] nos. of pile points for m 0 360.00 -
Inclined hole (Raking 1H:4V).
5 H242 Boring through rock, up to [10m] for [14] nos. of pile m 0 460.00 -
points. Rate to include natural and artificial hard material
for Vertical hole.
6 H242 Boring through rock, up to [10m] for [14] nos. of pile m 0 490.00 -
points. Rate to include natural and artificial hard material
for Inclined hole (Raking 1H:4V).
13 H530 Pile integrity test (sonic echo test) on [300 mm] diameter nr 0 600.00 -
micropile
Carried Forward: -
B6/3
#REF!
BILL NO. 6 -
Bring Forward: -
STEEL SUPERSTRUCTURE
Item for supply and erection of structural members shall
be deemed to include delivery, protective and/or
decorative surface treatment, fabrication, handling,
hoisting, welded connections, bolted connections and
nondestructive testing.
Carried Forward: -
B6/4
#REF!
BILL NO. 6 -
Bring Forward: -
1 I111 Grade C15, Mass concrete blinding, [50 mm] thick. m2 0 19.00 -
2 I145 Grade C30, Reinforced concrete to bridge deck and run- m3 0 550.00 -
on-slab
3 I430 F3: Smooth finish to walls m2 0 70.00 -
4 I523 High tensile bars, nominal diameter: 12mm t 0 5,500.00 -
5 I524 High tensile bars, nominal diameter: 16mm. t 0 5,500.00 -
6 I615 Sealed [25mm] thick 'Expandite' or approved equivalent m 0 60.00 -
natural bonded cork filler
7 I616 Dowels – plain, [16mm diameter x 1100mm long] hot-dip nr 0 50.00 -
galvanised m.s. dowel bar
8 P320 Outlet drains; 100 mm diameter UPVC pipe including m 0 90.00 -
fittings
9 T414 [200mm x 6mm thick] rubber bearing strip m 0 200.00 -
EXPANSION JOINT
11 I613 Expansion joints, Fosroc Fosflex bridge joint F250 or m 0 2,000.00 -
approved equivalent expansion joint
BRIDGE BEARING
Supply and fix in position 'PSC Freyssinet' or approved
equivalent bridge bearings including dowel bars, grout,
mortared plinths including everything necessary all in
accordance with the specifications and drawings as
directed by the S.O.;
CONCRETE WALL
14 F131 Excavate in earth material m3 0 18.00 -
15 I125 Grade C20, Mass concrete to walls m3 0 480.00 -
16 I414 F1: Rough finish to walls m2 0 60.00 -
Carried Forward: -
B6/5
#REF!
BILL NO. 6 -
Bring Forward: -
SURFACE PROTECTION
Gunite Face
1 G410 [75 mm] thick [G20] guniting. Rate shall be deemed to m2 0 100.00 -
include steel fabric mesh.
GABION
3 G211.1 [1.0m wide x 1.0m high x 3.0m long] rock-filled gabion m3 0 #REF! #REF!
with PVC-coated wire gauge size of [2.7 mm] as per
Specification clause (3.6) and as shown in the drawings.
B6/6
#REF!
BILL NO. 6 -
H PILING WORKS
1 H110 Provision of all necessary piling plant and equipment, sum -
transportation to the Site, handling, assembling, and
removal off the Site after completion of operation.
2 H120 Moving and handling of all piling plant and equipment sum -
within the Site and from location to location as often as is,
and whenever necessary for the execution of the whole
piling operation.
3 H241.1 Boring in earth, up to [10m] for [14] nos. of pile points for m 0 340.00 -
Vertical hole.
4 H241.2 Boring in earth, up to [11m] for [14] nos. of pile points for m 0 360.00 -
Inclined hole (Raking 1H:4V).
5 H242 Boring through rock, up to [10m] for [14] nos. of pile m 0 460.00 -
points. Rate to include natural and artificial hard material
for Vertical hole.
6 H242 Boring through rock, up to [10m] for [14] nos. of pile m 0 490.00 -
points. Rate to include natural and artificial hard material
for Inclined hole (Raking 1H:4V).
13 H530 Pile integrity test (sonic echo test) on [300 mm] diameter nr 0 600.00 -
micropile
Carried Forward: -
B6/7
#REF!
BILL NO. 6 -
Bring Forward: -
STEEL SUPERSTRUCTURE
Item for supply and erection of structural members shall
be deemed to include delivery, protective and/or
decorative surface treatment, fabrication, handling,
hoisting, welded connections, bolted connections and
nondestructive testing.
Carried Forward: -
B6/8
#REF!
BILL NO. 6 -
Bring Forward: -
1 I111 Grade C15, Mass concrete blinding, [50 mm] thick. m2 0 19.00 -
2 I145 Grade C30, Reinforced concrete to bridge deck and run- m3 0 550.00 -
on-slab
3 I430 F3: Smooth finish to walls m2 0 70.00 -
4 I523 High tensile bars, nominal diameter: 12mm t 0 5,500.00 -
5 I524 High tensile bars, nominal diameter: 16mm. t 0 5,500.00 -
6 I615 Sealed [25mm] thick 'Expandite' or approved equivalent m 0 60.00 -
natural bonded cork filler
7 I616 Dowels – plain, [16mm diameter x 1100mm long] hot-dip nr 0 50.00 -
galvanised m.s. dowel bar
8 P320 Outlet drains; 100 mm diameter UPVC pipe including m 0 90.00 -
fittings
9 T414 [200mm x 6mm thick] rubber bearing strip m 0 200.00 -
EXPANSION JOINT
11 I613 Expansion joints, Fosroc Fosflex bridge joint F250 or m 0 2,000.00 -
approved equivalent expansion joint
BRIDGE BEARING
Supply and fix in position 'PSC Freyssinet' or approved
equivalent bridge bearings including dowel bars, grout,
mortared plinths including everything necessary all in
accordance with the specifications and drawings as
directed by the S.O.;
CONCRETE WALL
14 F131 Excavate in earth material m3 0 18.00 -
15 I125 Grade C20, Mass concrete to walls m3 0 480.00 -
16 I414 F1: Rough finish to walls m2 0 60.00 -
Carried Forward: -
B6/9
#REF!
BILL NO. 6 -
Bring Forward: -
SURFACE PROTECTION
Gunite Face
1 G410 [75 mm] thick [G20] guniting. Rate shall be deemed to m2 0 100.00 -
include steel fabric mesh.
GABION
3 G211.1 [1.0m wide x 1.0m high x 3.0m long] rock-filled gabion m3 0 #REF! #REF!
with PVC-coated wire gauge size of [2.7 mm] as per
Specification clause (3.6) and as shown in the drawings.
B6/10
BILL 2e.3
BRIDGE 3 (15 METER)
Item No. Code No. Description Unit Qty. Rate Amount (RM)
Temporary Work
3 A529.1 Construct temporary works and remove and make good sum
all works after completion; fixed charge.
F100 EXCAVATION
H PILING WORKS
1 H110 Provision of all necessary piling plant and equipment, sum 50,000.00
transportation to the Site, handling, assembling, and
removal off the Site after completion of operation.
2 H120 Moving and handling of all piling plant and equipment sum 10,000.00
within the Site and from location to location as often as
is, and whenever necessary for the execution of the
whole piling operation.
3 H241.1 Boring in earth, up to [10m] for [14] nos. of pile points m 140 340.00 47,600.00
for Vertical hole.
4 H241.2 Boring in earth, up to [11m] for [14] nos. of pile points m 154 360.00 55,440.00
for Inclined hole (Raking 1H:4V).
5 H242 Boring through rock, up to [10m] for [14] nos. of pile m 140 460.00 64,400.00
points. Rate to include natural and artificial hard
material for Vertical hole.
6 H242 Boring through rock, up to [10m] for [14] nos. of pile m 140 490.00 68,600.00
points. Rate to include natural and artificial hard
material for Inclined hole (Raking 1H:4V).
7 H243 Supply and install [177.8mm OD x 10.4mm thick Grade m 574 500.00 287,000.00
N-80 API pipe].
8 H247 Grouting with non-shrink cement grout Grade [C30] as m3 21 3,000.00 63,000.00
specified into drilled hole. Rate shall include excess
cement required when the grout volume exceeded the
theoretical volume.
10 H510.1 Initial static load test on 300 mm diameter micropile up nr 1 40,000.00 40,000.00
to two times working load of 800 kN (Test load of
1,600kN).
13 H530 Pile integrity test (sonic echo test) on [300 mm] diameter nr 24 600.00 14,400.00
micropile
3 I145 Grade C30, Reinforced concrete to abutment and m3 120 600.00 72,000.00
wingwall
4 I414 F3: Smooth finish to walls m2 230 70.00 16,100.00
5 I523 High tensile bars, nominal diameter: 12mm t 1 6,000.00 6,000.00
6 I524 High tensile bars, nominal diameter: 16mm. t 5 6,000.00 30,000.00
7 I525 High tensile bars, nominal diameter: 20mm. t 2 6,000.00 12,000.00
8 I526 High tensile bars, nominal diameter: 25mm. t 14 6,000.00 84,000.00
9 F410 Supply and lay 'Polyfelt TS20' or approved equivalent m2 195 18.50 3,607.50
filter cloth for abutment and wingwall
10 F314.1 Filling with approved filter material m3 23 90.00 2,070.00
11 F314.2 Filling with approved granular backfill m3 80 130.00 10,400.00
12 I652 [150 mm DN, PN 15] perforated uPVC pipe including nr 36 150.00 5,400.00
450mm x 450mm gravel pocket and filter cloth 'Polyfelt
TS20'
13 N631.3 Supply and paint two coats of tar based waterproofing m2 180 45.00 8,100.00
paint to the back of the abutments and wingwall
STEEL SUPERSTRUCTURE
14 L110 Supply and erection of structural members for frames; t 28 16,000.00 448,000.00
steel to [BS:4360] (Grade 50B)
15 L161 HSFG bolts to [BS 4604], nominal diameter [16 mm] nr 192 45.00 8,640.00
(Grade 10.9)
16 L162 HSFG bolts to [BS 4604], nominal diameter [20 mm] nr 96 50.00 4,800.00
(Grade 10.9)
17 L163 HSFG bolts to [BS 4604], nominal diameter [24 mm] nr 1,016 65.00 66,040.00
(Grade 10.9)
18 L312 [102 mm x 51 mm x 10.42 kg/m] C-channel shear studs m 62 100.00 6,200.00
to [BS:4360] (Grade 43A)
1 I111 Grade C15, Mass concrete blinding, [50 mm] thick. m2 100 26.00 2,600.00
2 I145 Grade C30, Reinforced concrete to bridge deck and run- m3 95 600.00 57,000.00
on-slab
3 I414 F3: Smooth finish to walls m2 325 70.00 22,750.00
4 I523 High tensile bars, nominal diameter: 12mm t 7 6,000.00 42,000.00
5 I524 High tensile bars, nominal diameter: 16mm. t 9 6,000.00 54,000.00
6 I615 Sealed [25mm] thick 'Expandite' or approved equivalent m 33 60.00 1,980.00
natural bonded cork filler
7 I616 Dowels – plain, [16mm diameter x 1100mm long] hot- nr 22 50.00 1,100.00
dip galvanised m.s. dowel bar
8 P320 Outlet drains; 100 mm diameter UPVC pipe including m 20 90.00 1,800.00
fittings
9 T414 [200mm x 6mm thick] rubber bearing strip m 20 200.00 4,000.00
10 L240 Galvanised mild steel handrail with fixing accessories as m 50 300.00 15,000.00
shown on the drawing.
EXPANSION JOINT
11 613 Expansion joints, Fosroc Fosflex bridge joint F250 or m 21 2,000.00 42,000.00
approved equivalent expansion joint
BRIDGE BEARING
CONCRETE WALL
SURFACE PROTECTION
Gunite Face
1 G410 [75 mm] thick [G20] guniting. Rate shall be deemed to m2 750 100.00 75,000.00
include steel fabric mesh as shown in Drawing No. (….).
GABION
3 G211.1 [1.0m wide x 1.0m high x 3.0m long] rock-filled gabion m3 200 530.00 106,000.00
with PVC-coated wire gauge size of [2.7 mm] as per
Specification clause (3.6) and as shown in the drawings.
1.Turbidity;
2.pH;
3.Total Suspended Solids (TSS);
4.Biochemical Oxygen Demand (BOD);
5.Chemical Oxygen Demand (COD);
6.Dissolved Oxygen (DO);
7.Oil & Grease;
8.E. Coli;
9.Ammoniacal Nitrogen (NH3-N)
1.Turbidity;
2.pH;
3.Total Suspended Solids (TSS);
4.Biochemical Oxygen Demand (BOD);
5.Chemical Oxygen Demand (COD);
6.Dissolved Oxygen (DO);
7.Oil & Grease;
8.E. Coli;
9.Ammoniacal Nitrogen (NH3-N)
e) Noise Monitoring
Conduct quarterly noise monitoring (12 hours average) Sum 8 120.00
including Leq, L10 and L90 as specified or as directed
by the S.O. through out the contract period.
f) Vibration Monitoring
Conduct vibration monitoring as specified or as directed Sum 1 300.00
by the S.O. through out the contract period .
9.4.3 Training
i)Local Training
Conduct environmental training on site for JKR Nr
personnel once a year.
PHYSICAL WORK
15,000.00
9,000.00
12,000.00
36,000.00
36,000.00
2,160.00
2,160.00
2,880.00
960.00
300.00
44,460.00
44,460.00
7,500.00
6,600.00
NIL
NIL
NIL
20,000.00
78,560.00