EC-2502
1. SAFETY AND USAGE CONDITIONS
Prior to the installation please read the following instruction.
Electric installation should be done in accordance with PN-IEC-60364-1 norm by the authorized
person. Installation should not be directly exposed to atmospheric electrostatic discharge.
It is forbidden to connect the panel to other installations, with exception of the application
recommended by the producer.
Electronic cassette should not be exposed to high temperature or humidity.
Self maintenance is only permitted for qualified persons. Device maintenance by unauthorized
persons may result in the lost of warranty.
It is forbidden to connect power supply from sources with different parameters than recommended
by the producer to panel clamps. The producer is not responsible for any lost occurred due the
usage of improper power supplies.
Signals from the digital entry phone system should not be directly connected to RTV sets,
because of risk of devices and system damages.
Do not clean the electronic cassette with gasoline, solvents or strong detergents as it may cause
damage of the device surface.
coil
Page 3
LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ód, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
EC-2502
Electronic cassette EC-2502 can control electro-catch (by default setting). It is also a possibility to
control electromagnetic lock (or reverse
electro-catch). The selection of control method enables jumper ZT1.If electromagnetic lock is used
jumper should be put on joint J3 and operation frequency (parameter FrY) should be set on 0! (see
figure 2).In case electro-catch is used jumper should be removed from joint J3.
a) b)
SW2
P2 P3
X
P1
J3 ZT1 J3 ZT1
ZT1 A) Electro-catch J3 demagnetizing on
ZT1 B) Electromagnetic lock J3 demagnetizing off
4. ADJUSTMENT
Elements of entry phone system are preliminarily adjusted and position of internal
potentiometers should not be changed without necessity.
Electronic cassette EC-2502 has the following adjustment elements (see dwg. 3):
P2 P1 P3
+ - + - - +
MICROPHONE BALANCE
LOUDSPEAKER
Kaseta elektroniki
0.8A
+12V
+13V
0.5A
0.8 A
+7V
1A
CP-2500
PR/CS
GZA
AC1
AC2
AC3
AC4
VZA
A/B
GS
VS
GP
GZ
VP
KZ
+B
VZ
K1
K2
K3
K4
K5
K6
J3
L+
-B
L-
A detailed description of the regulation of electronic cassette EC-2502 is in the installation, service
and programming instruction of digital entry phone system CD-2502.
Page 4
LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ód, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
EC-2502
5. PROGRAMMING OF ENTRY PHONE
Entering programming mode
ENTER 5x KEY AND ENTER SUCCESSIVELY 4 DIGITS OF CODE
OR
1 2 3 4
1 3 1 2 C
EtyP (0,1) 0 U,H Operation mode of el. cassette; 0 - subordinate (U), 1 - main(H)
tOc 10...255 30 U,H Waiting time for picking up the receiver in seconds
tro 10...255 120 U,H Time of conversation
t1d 10...255 100 U,H Time of signal generation
tPA 20...255 150 U,H Pause time
trY 1...31 5 U,H Time of electro-catch operation in seconds
FrY 0...200 50 U,H Frequency of electro-catch supply voltage in Hz
CAin 0...1234 0 U Video inputs of CVP-x switch serviced by the CD system
CAtP 1...10 3 U Time interval of switching video signal in seconds
nbL 0...9998 0 U Block number
Pnu 0...9998 0 U Range shift
LPi 0...100 0 U Amount of rooms on the floor
LLo 1...240 1 U Range of serviced numbers - low value
LHi 1...240 240 U Range of serviced numbers - high value
LdP 0...9998 0 U,H Redirecting of not serviced numbers
NbP 0...9998 0 H Block number for redirecting of not serviced numbers
Un 0...9998 0 U Additional number not included in the serviced range
3 0 1 2 C
Page 6
LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ód, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
EC-2502
6. RESTORE THE INITIAL SETTINGS
NOTE!
Restoring the default settings results in the loss of information stored in EEPROM memory of
electronic cassette (changed codes of coded lock, numbers of electronic keys, individual settings
etc.). Prior to this operation one should get acquainted with the content of this chapter.
Restoring the default operation parameters for electronic cassette can be done in two ways: globally
(refers to parameters set by procedures P-1, P-2, P-5, P-6 and P-10) or selectively (default values
defined by individual procedures are restored).
Global restoration of default parameters. Reset of electronic cassette.
In order to restore default parameters of electronic cassette operation pushbutton INIT (SW2) should
be pressed and while still pressing it pushbutton RESET (SW1, see dwg. 2) should be pressed for
a while and released. After approx. 2 seconds pushbutton INIT (SW2) can be released, at that time
on the display of the external panel quickly changing digits will appear.
When the countdown visible on the display stops, all default settings will be restored in the cassette:
default codes of coded locks, code of installing specialist, main unit operation parameters defined
in procedures P-1, P-2, P-3 and P-5.
NOTE!
It pushbutton INIT after having initiated remains pushed in for longer than 10 s, electronic cassette
will start resetting all recorded iButton and/or RFID keys.
Operation mode of electronic cassette will not be changed i.e. if before restoring default settings the
cassette was configured as EC-2502/H, after finishing of this operation the cassette will still operate
in this mode.
Pushbutton RESET is used for momentary stopping the operation of a processor. Its pressing makes
that the processor stops working, while the release causes the operation resumption; the processor
starts the operation from the program beginning.
The pushbutton is used in the case of main unit hang-up (it does not react to key selection and
random signs appear on the display) and restoring default settings.
Pressing pushbutton INIT is information for the processor that the default settings should be restored
- main unit checks if this pushbutton was pressed just after switching on the supply or pressing and
releasing of RESET pushbutton. That is why the sequence of operations is important during restoring
the default values. SW1
RESET
INIT
SW2
P2 P3
X
P1
8. FAULTS MESSAGES
CD-2502 entry phone can signal the following faults:
EC: Means that two or more infrared beams in keyboard are damaged or covered. Clean the
surface and sides of keyboard out of eventually dirt.
E2: Means short-circuit of uniphone line. Installation should be checked, short-circuit should
be eliminated or damaged uniphones should be replaced. By measuring current input on
uniphone line, the nature of fault can be determined.
E0: This message means that system EEPROM memory is damaged in the electronic cassette.
For repairs contact the service.
EEr:Means an error in recording or in reading memory with system settings or codes of coded
lock. For repairs contact the service.
9. TECHNICAL DATA
ZS-K-25/01 or TSZZM 25/021M power supply feeder of el. cassette - description of wires
white
brown USEC1
red UPRI = ~230V
USEC2 USEC1 = 12,5V / 0,8A
UPRI brown USEC1 + USEC2 = 14,5V / 0,8A
brown USEC3 = 12V / 1A
USEC3
blue
brown
Page 8
LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ód, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
EC-2502
10. DESCRIPTION OF TERMINALS
AC1 el. cassette supply 14,5V AC K1 (VS)* ext. panel supply (stabilized voltage +12V)
AC2 el. cassette supply 14,5V AC K2 (T)* digital data from/to ext. panel
AC3 electro-catch supply 12V AC K3 (GS)* digital mass
AC4 electro-catch supply 12V AC K4 (SP)* loudspeaker
GP mass of non-stabilized voltage K5 (GA)* analogue mass
VP non-stabilized voltage output K6 (MC)* microphone
GZA mass of electro-catch supply L+ uniphone line + (if works as EC-2502U)
VZA electro-catch supply communication line between cassette H and U
KZ output of key switching on el.-catch (if works as EC-2502H)
VZ electro-catch supply L- uniphone line - (if works as EC-2502U)
GZ mass of key switching on el.-catch LM master line (to connect main electronic cassette)
GS' mass of stabilized voltage NC free terminals (e.g. to connect segments of wire)
VS' stabilized voltage +12V X input of electronic key reader
PR door opening pushbutton B+ connection of accumulator (+)
CS selection of video signal source B- connection of accumulator (-)
AC1 VP
stabilizer
+12V
VS
AC2
GS
GP
MC
L+
SP
L- GA
AC3 1,85 A
VZA
AC4
GZA
el.catch
ZT1 VZ
A switching
NC
uP lock
B key KZ
JP3
NC
demagnetizing
GZ
X
PR
CS
T
GD
MON1
MON2
MON3
MON4
C+
L+
C-
L-
SUBORDINATE ENTRANCE
CVR-x
12 V AC 14,5 V AC
1A 0,8 A
power supply
of electronic
230 V AC cassette
Brown
AC3 Brown
Brown
AC2 White
AC4
AC1
GZA
NC1
NC2
VZA
GS
GS
VS
LM
GZ
CS
VZ
KZ
K6
K5
K4
K2
K3
K1
L+
L-
EC-2502/U
GX
C+
K6
K5
K4
K2
K3
K1
C-
CP-xxxx
Electro-catch
C2+
C1+
LM
C2-
C1-
L-
CS
V+
X+
X-
CVP-1
12 V AC 14,5 V AC
1A 0,8 A
power supply
NOTE! of electronic
! Terminals GZ, GZA and VZ, VZA
are connected permanently
230 V AC cassette
MAIN ENTRANCE
Brown
AC2 White
AC1
GZA
NC1
NC2
AC4
VZA
GS
GP
LM
GZ
VP
VZ
KZ
K6
K5
K4
K2
K3
K1
L+
L-
EC-2502/H
GX
C+
K6
K5
K4
K2
K3
K1
C-
CP-xxxx
Electro-catch
to another
Distance CVR-M
CVR
Clamps <30m
L+,L-,C+,C- 0,5mm
VC,GV/GC 0,5mm
YTKSY,UTP
CVR-1 6 MON1
MON4
MON3
M
MON2 MV-645x 15V DC
MON4 MON3
CVR-2
Distance CVR-M
Clamps <15m <30m
6 L+,L-,C+,C- 0,5mm
Distance
2 +15V,GND 0,5mm 2x0,5mm
Clamps <15m
YTKSY,UTP
+15V, GND 1mm2
any
MON2
15V DC /4A
MVC-6x50
M
Distance U-E
Clamps <50m <150m 4 MON1
4
L+,L-, 0,5mm 2x0,5mm
C+,C- 0,5mm Distance
MVC-6x50 13,5V DC
YTKSY,UTP,LAN T11, XzTKMXpw CVR-M
Clamps <30m
L+,L-,C+,C- 0,5mm
YTKSY,UTP
Staircase 1
DISTRIBUTION
CABINET U power supply
of electronic
cassette
EC-2502/U 4
Note!
10 In panels CP-250xxR
0,5mm
YTKSY,UTP,LAN T11,
XzTKMSpw
6 (LM,L+,L-,
V+,G,CS) CP-25xx ! should be increase the
number of wires connected
CVP-1 to terminal K3.
2 (C+,C-)
Clamps Distance
CP EC <15m <30m
Note!
to another 4 K1,K4 K1,K4 0,5mm 2x 0,5mm
In panels 250xxR
staircases K2, K6 K2, K6 0,5mm 0,5mm GX clamp leave
K3 K3 3x 0,5mm 5x 0,5mm unconnected
K5 K5 2x 0,5mm 2x 0,5mm
X, GX X, GS 0,5mm 0,5mm
YTKSY,UTP,LAN T11,XzTKMXpw
4
Figure 8: Selection of wires for entry phone CD-2502 in video version - part 1
Page 11
LASKOMEX PPUH, ul. D¹browskiego 249, 93-231 £ód, tel. (42) 671 88 00, fax (42) 671 88 88, e-mail: laskomex@laskomex.com.pl, http://www.laskomex.com.pl
A
Full installation, usage
and programming
manual is available on
www.laskomex.com.pl
Distance H-U
Clamps <50m <150m <250m
EC/H CVP-1
L+,L- LM,L- 0,5mm 2x0,5mm 3x0,5mm
Note!
In panels CP-250xxR
OPTION H NC1,NC2 C+,C-
YTKSY,UTP,LAN T11, XzTKMXpw
0,5mm
Accumulator 2 4
! should be increase the
number of wires connected
12V/6Ah (B+,B-)
0,5mm
EC-2502/H
power supply
of electronic
to terminal K3. <1m Distance cassette
Clamps Distance Clamps <15m
Note! CP EC <15m <30m AC1,AC2, 1mm2
In panels 250xxR K1,K4 K1,K4 0,5mm 2x 0,5mm AC3,AC4
GX clamp leave K2, K6 K2, K6 0,5mm 0,5mm any
12
unconnected K3 K3 3x 0,5mm 5x 0,5mm
K5 K5 2x 0,5mm 2x 0,5mm
Distance
X, GX X,GS 0,5mm 0,5mm 2 Clamps <15m
C+, C- NC1, NC2 0,5mm 0,5mm
GZ,KZ 1mm2
YTKSY,UTP,LAN T11, XzTKMXpw
2(K1,K3) any
Distance
List of CP-25xx 2 Clamps <15m
occupants GS,PR 0,5mm
any
Electro-catch Dooropen
button
Figure 9: Selection of wires for entry phone CD-2502 in video version - part 2
Remember!
Selective collection and recycling of used electronic and electric equipment
considerably contributes to the protection of human health and life as well as protection
of natural environment.
Return of packaging materials for the material recycling saves raw materials and
reduces generating of wastes.