AAMA 501.2
The AAMA 501.2 (Quality Assurance and Diagnostic Water Leakage Field Check of
Installed Storefronts, Curtain Walls, and Sloped Glazing Systems) is designed to aid in
the water-tight testing of large glass areas meant to be permanently closed, such as
store fronts, curtain walls, and sloped glazing systems.

If you are looking for a test that measures water resistance in extreme weather
conditions, refer to the AAMA 502, AAMA 503, or the ASTM E 1105.

Testing overview: A project architect or another representative (specifier) will select


the area to be tested. This area should represent typical construction for the project.
A test is normally performed over a minimum area of 100 ft² and includes the edge of
the glass surface and places where the frame is horizontal, vertical, or intersecting.

It’s best to perform this test while the interior walls are unfinished so any moisture is
visible during the test and amendments can be made before the building is
completed. If test area is enclosed by interior finishes, the contractor should expect
additional costs of exposing the wall(s) and refinishing them after testing is complete.

The guide for testing is very specific. A constant pressure of between 30-35 psi is
applied from a ¾” (19 mm) diameter hose fitted with a nozzle. This ½” diameter brass
nozzle is to be part B-25 #6.030, sourced only from Monarch Manufacturing, to 

standardize test results. It is recommended to fit the nozzle with a gauge to measure
distance from the test surface.
www.bdg-usa.com/aama-501.2.html 1/4
7/8/2021 AAMA 501.2 | Hose Nozzle Water Spray Testing

For the actual test, a 5-foot section is chosen that bears both the frame and a joint in
the glass. The nozzle is held 1-foot away from the glass and slowly moved back and
forth for the duration of the 5-minute test. The chosen area is soaked from the lowest
horizontal brace to any adjacent vertical framing. During the test, a member of the
testing team will be inside to monitor the wallsand check for any leakage. Any amount
of water greater that ½ ounce over the course of 5 minutes will be deemed a failure.

Water Leakage “Water leakage is defined as any uncontrolled water that appears on
any normally exposed interior surfaces, that is not contained or drained back to the
exterior, or that can cause damage to adjacent materials or finishes.” (From AAMA
501.2-03)

If a leak is found, the wall must first dry completely, be sealed, and be re-tested. To
pinpoint the weak spots in construction, a waterproof tape can be used to completely
seal the area. All joints, gaskets, and framing elements are covered from the outside
and removed in 5-foot sections to retest for the exact spot of leakage. If no leaks
occur, the area stays uncovered, and the test goes on. Any areas that have been
taped due to leaking will have to be examined, repaired based on the
recommendation of the architect, and re-tested.

BDG utilizes professional testing equipment that is calibrated to each specific testing
standard for accurate results. Our field consultants are properly trained and
knowledgeable of all testing standards. BDG has extensive knowledge of most
building systems and specializes in forensic water intrusion investigations. This allows
us to not only properly test fenestrations on new construction projects, but also
pinpoint the cause of any test failures and provide accurate recommendations to
achieve successful testing results. Failures during quality assurance (new
construction) testing can result in unnecessary delays that can impact your bottom
line.

If you are looking for a reputable second or third-party testing company to perform
accurate professional testing, provide concise reports, and help you through the
entire process, contact BDG today. We provide testing services throughout the United
States from our headquarters located in Atlanta, GA.

Give us a call to discuss your next AAMA 501.2 Hose Nozzle Testing Project.

www.bdg-usa.com/aama-501.2.html 2/4
7/8/2021 AAMA 501.2 | Hose Nozzle Water Spray Testing

WATER PENETRATION TESTING

ASTM / AAMA Testing

Storefront / Curtain Wall Testing

Forensic Water Intrusion Testing

Masonry Wall Drainage Testing

Wall Penetration Testing

ASTM & AAMA TESTING SERVICES

ASTM E331

ASTM E547

ASTM E783

ASTM E1105

ASTM C 1601

ASTM C 1715

AAMA 501.2

AAMA 502

AAMA 503

DIAGNOSTIC WATER INTRUSION TESTING

ASTM E2128

AAMA 511

VIEW OUR BROCHURE

www.bdg-usa.com/aama-501.2.html 3/4
7/8/2021 AAMA 501.2 | Hose Nozzle Water Spray Testing

Click Here to View


Our Company Brochure

© Copyright 2021 - Building Diagnostics Group | Sitemap

www.bdg-usa.com/aama-501.2.html 4/4

You might also like