Ensures high 36 Parameters Supports geriatric and
accuracy with Enhanced paediatric samples
Tri-angle Laser patient care
Flowcytometry
KEY FEATURES
36 Parameters including
WBC Diff- world
NLR, NRBC, CWBC,
best technology
Mentzer index and RDW I
Ensure accurate and precision P-LCR, P-LCC, PDW-SD & PDW-CV aids in
differential diagnosis of cases with abnormal
Intensity of light scattered from semiconductor
platelet counts supports clinical investigation
laser beam on the blood cells reflects cell size
and intra cellular density RDW-SD, RDW-CV & MCV aids in screening for
Precision
Low angle scatter shows cell size, while the causes of anemia
Advanced Software
middle and high angle display intracellular NLR: Novel prognostic marker for predicting and Accuracy
information (nucleus and cytoplasmic content). short and long-term mortality in patients with
Data thus captured plots 4 2D scattergrams COVID-19, cancer, sepsis, CVD, and Excellent short and long-term precision within
Provision to include microscopic investigations such as
post-operative complications. An NLR >3 is 2% bands segment, blast, etc. in the printed report
Three reagent system for cost-effective
indicative of disease Consolidated patient reports can be generated for
operations (DIL, LYSE 1, LYSE 2 and cleaner) *ALY% 0.7 % Highly accurate results correlating with
severity *LIC# 0.05 10^3/uL customized parameters such as blood type, Rh blood
Independent WBC / Baso channel uses special *LIC% 0.8 % microscopic examination and clinical findings
NRBC - To rule out *NRBC# 0.022 10^3/uL group, ESR, reticulocyte, CRP along with other
hemolytic agent that extracts Basophils *NRBC% 0.33 % Specific flagging for microscopic slide review
Leuckemia, anemia or *cWBC 6.70 10^3/uL
reportable parameters
spleen disorder *NLR 1.98 of clinically relevant parameters
Legend: RBC 5.58 10^6/uL
QR code scanner facilitates direct inputs of QC values
Neutrophils CWBC - To obtain accurate HGB 16.6 g/dL
HCT 49.7 %
WBC count for better Sample
Analysis Review QC Reagent
Management
LIS
Lymphocytes
clinical treatment. QC Type L-J Print Delete Outliers
Basophils
QC Settings QC Analysis QC Graph QC Table
Microscopic Exam. Settings
Mentzer index and RDW I -
File No.: 1 QC Mode: Whole Blood-CBC+DIFF Lot No.: DH 1901
Existing / Total: 5/500 Exp. Date: 05-05-2019 Level: Low
Editor: service QC Sample ID:
48.2 40.20
5 Eosinophil
Lym%
39.9
39.2 0.73
6 Basophil
Convenient
Mon% 0.43
5.4
4.7
0.8 8.2 8 Atypical Lymph
impedance 9 Blast
5
5
Next Sample: 62160 Mode: VWB-CBC+DIFF
Sampel Count User.admin 06-03-2019 18:25:47
121939 H clean 4 x 50
HEM/H 560/06-2022/V-005/Dom/4pg/Bro