You are on page 1of 30

ST

AG
E
D
C
G

D C

G
G
D
C

SOUNDSTORM 2023
ORG
S T 0
A E -8 'x '4

CONT
2 0
' OF E
ORG
S T 0
A E -8 'x '4

A
I E
R
N
C
I
COUT NRE COUT NRE COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

BIG BEAST STAGE


STRUCTURAL DRAWINGS
DRAWING LIST
SHEET NUMBER DRAWING TITLE
M9307-RBG-PS007-ZZ-DR-ST-00001 BIG BEAST STAGE - COVER SHEET
M9307-RBG-PS007-ZZ-DR-ST-00002 BIG BEAST STAGE COVER GENERAL NOTES SHEET 1
M9307-RBG-PS007-ZZ-DR-ST-00003 BIG BEAST STAGE COVER GENERAL NOTES SHEET 2
M9307-RBG-PS007-ZZ-DR-ST-00004 BIG BEAST STAGE BASIS OF DESIGN AND PERFORMANCE CRITERIA
M9307-RBG-PS007-ZZ-DR-ST-00005 BIG BEAST STAGE RIGGING/LOADING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12001 BIG BEAST STAGE FOUNDATION PLAN
M9307-RBG-PS007-ZZ-DR-ST-12002 BIG BEAST STAGE GROUND FLOOR PLAN
M9307-RBG-PS007-ZZ-DR-ST-12003 BIG BEAST STAGE LOWER ROOF BOTTOM CHORD STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12004 BIG BEAST STAGE LOWER ROOF TOP CHORD STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12005 BIG BEAST STAGE UPPER ROOF BOTTOM CHORD STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12006 BIG BEAST STAGE UPPER ROOF TOP CHORD STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12007 BIG BEAST STAGE CONNECTION DETAILS OPTION A
M9307-RBG-PS007-ZZ-DR-ST-12008 BIG BEAST STAGE CONNECTION DETAILS OPTION B
M9307-RBG-PS007-ZZ-DR-ST-12009 TYPICAL FOUNDATION DETAILS
M9307-RBG-PS007-ZZ-DR-ST-12010 BIG BEAST STAGE VIB LEVEL 1 STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12011 BIG BEAST STAGE VIB LEVEL 2 STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12012 BIG BEAST STAGE MEP LEVEL 3 STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-12013 BIG BEAST STAGE MEP BRIDGE LEVEL 4 STEEL FRAMING PLAN
M9307-RBG-PS007-ZZ-DR-ST-14001 BIG BEAST STAGE ELEVATION ALONG GRID 1
M9307-RBG-PS007-ZZ-DR-ST-14002 BIG BEAST STAGE ELEVATION ALONG GRID 2
M9307-RBG-PS007-ZZ-DR-ST-14003 BIG BEAST STAGE ELEVATION ALONG GRID 4
M9307-RBG-PS007-ZZ-DR-ST-14004 BIG BEAST STAGE ELEVATION ALONG GRID 5
M9307-RBG-PS007-ZZ-DR-ST-14005 BIG BEAST STAGE ELEVATION ALONG GRID 6
M9307-RBG-PS007-ZZ-DR-ST-14006 BIG BEAST STAGE ELEVATION ALONG GRID 7
M9307-RBG-PS007-ZZ-DR-ST-14007 BIG BEAST STAGE ELEVATION ALONG GRID A
M9307-RBG-PS007-ZZ-DR-ST-14008 BIG BEAST STAGE ELEVATION ALONG GRID B
M9307-RBG-PS007-ZZ-DR-ST-14009 BIG BEAST STAGE ELEVATION ALONG GRID C
M9307-RBG-PS007-ZZ-DR-ST-14010 BIG BEAST STAGE ELEVATION ALONG GRID D
M9307-RBG-PS007-ZZ-DR-ST-14011 BIG BEAST STAGE ELEVATION ALONG GRID E
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
M9307-RBG-PS007-ZZ-DR-ST-14012 BIG BEAST STAGE SECTIONS
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
STEEL COLUMN QUANTITIES STEEL FRAMING QUANTITIES terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
SIZE WEIGHT* SIZE WEIGHT* licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.
UC152x152x51 20065 kg UKCHS244.5x10 3002 kg
DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC152x152x23 18889 kg FABRICATED BEAM (REFER TO TABLES FOR DIMENSIONS) 57204 kg
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC203x203x86 7954 kg FABRICATED BEAM (REFER TO TABLES FOR DIMENSIONS) 14850 kg
Structural, Civil & Construction
UC203x203x71 27604 kg FPS100x10 183 kg Engineering Consultant
UC203x203x60 2365 kg UB178x102x19 24256 kg
UC203x203x46
UC254x254x89
45635 kg
68570 kg
UB254x146x31
UB356x171x45
300 kg
13582 kg
Robert BirdGroup
Member of the Surbana Jurong Group
UC254x254x73 45944 kg UB457x191x82 9039 kg
DUBAI OFFICE
UC305x305x137 23464 kg UB457x152x52 13579 kg
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
UC305x305x118 24973 kg UC152x152x51 13164 kg Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
UC305x305x97 29130 kg UC152x152x44 3351 kg
Jebel Ali, Dubai
UC356x368x177 34302 kg UC152x152x37 8196 kg PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
UC152x152x30 31074 kg UC152x152x30 22163 kg
UC152x152x23 13406 kg Client

UC203x203x86 5326 kg MDLBEAST


UC203x203x71 5321 kg
*STEEL QUANTITIES DO NOT INCLUDE THE UC203x203x60 21637 kg
WEIGHT OF THE CONNECTIONS UC203x203x52 3367 kg
UC203x203x46 26173 kg
UC254x254x89 47957 kg
UC254x254x73 18562 kg Project
UC305x305x137 12017 kg
UC305x305x118 9612 kg
SOUNDSTORM 2023
UC305x305x97 16805 kg
UC356x368x177 30082 kg
70 DIA BAR OR MACALLOY 460 M76 (OR EQUIVALENT) 16097 kg
80 DIA BAR OR MACALLOY 460 M76 (OR EQUIVALENT) 8680 kg
Title

BIG BEAST STAGE - COVER SHEET


*STEEL QUANTITIES DO NOT INCLUDE THE
WEIGHT OF THE CONNECTIONS

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:04 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-00001 A02


ST
1.0 GENERAL NOTES

AG
E
D
C
6. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE DESIGN AND VERIFICATION OF ALL ADDITIONAL CONNECTION REQUIRED FOR
G

8.1 CONNECTIONS
D
C

G
G
G
G
D
C

LIFTING OF THE STRUCTURE AS PER THEIR CHOSEN METHOD STATEMENT


1. RELEVANT DOCUMENTS TO BE READ IN CONJUNCTION WITH THE STRUCTURAL DRAWINGS ARE:
7. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ANY DAMAGES TO ARCHITECTURAL FINISHES AND/OR STRUCTURAL MEMBERS THAT 1. CONNECTION/GUSSET PLATES SHALL NOT BE LESS THAN 16MM THK UNLESS NOTED OTHERWISE. ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
a. BASIS OF DESIGN AND PERFORMANCE CRITERIA (BY RBG).
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

OCCUR DURING LIFT/ INSTALLATION


2. THE DESIGN STRENGTH OF CONNECTION PLATES SHALL BE TAKEN AS THE FOLLOWING:
b. SPECIFICATIONS. 8. THE CONTRACTOR SHALL SUBMIT THE DESIGN DOCUMENTATION AND METHOD STATEMENT FOR ERECTION PROCEDURES TO THE t ≤ 16 fy = 355 MPa
CLIENT FOR REVIEW AND COMMENT. THE CLIENT AND/OR CLIENT'S ENGINEERS SHALL COMMENT ON THE DESIGN FOR ERECTION 16 < t ≤ 40 fy = 345 MPa KEY PLAN
c. ARCHITECTS DRAWINGS AND SPECIFICATIONS. AND METHOD STATEMENT WITHOUT RELIEVING THE CONTRACTOR OF THEIR SOLE RESPONSIBILITY FOR THE TEMPORARY DESIGN 40 < t ≤ 60 fy = 335 MPa
FOR TRANSPORTATION AND ARCHITECTURAL FINISHES.
d. EXISTING SITE INFORMATION.
9. IT IS RESPONSIBILITY OF ERECTION CONTRACTOR TO REMOVE ALL TEMPORARY MEMBERS FROM THE STRUCTURE AFTER
e. SURVEY DRAWINGS. INSTALLATION. 8.2 STRUCTURAL WELDING
f. ADDITIONAL DOCUMENTS (IF AVAILABLE), INCLUDING BUT NOT LIMITED TO: 1. ALL WELDING SHALL BE IN ACCORDANCE WITH AISC 360/AWS.



SERVICE ENGINEERS DRAWINGS AND SPECIFICATION.
APPROVED BUILDERS WORKS DRAWINGS.
5.0 TRANSPORT ("CONTRACTOR" IN THIS SECTION REFERS TO THE CONTRACTOR RESPONSIBLE FOR
TRANSPORTATION OF THE STRUCTURES)
2. ALL WELDS ARE ELECTRODE E70XX, WITH MINIMUM TENSILE STRENGTH OF 480 MPa.

• APPROVED SUB-CONTRACTORS DRAWINGS. 3. CHIP ALL WELDS FREE OF SLAG AFTER EVERY RUN.
• OTHER SPECIALISTS DRAWINGS AND SPECIFICATIONS.
1. DEFLECTION TOLERANCES DURING TRANSPORTATION TO BE LIMITED TO THE ALLOWABLE DEFLECTIONS OF ARCHITECTURAL 4. ALL BUTT WELDS ARE FULL PENETRATION BUTT WELDS UNO.
FINISHES.
2. IN CASES OF CONFLICT BETWEEN DRAWINGS AND/OR SPECIFICATIONS AND OTHER DISCIPLINES OR EXISTING CONDITIONS, THE CONTRACTOR
SHALL NOTIFY RBG AND OBTAIN CLARIFICATION. 5. ALL FILLET WELDS ARE A MINIMUM OF 8mm CONTINUOUS FILLET WELDS BOTH SIDES ALL AROUND UNO.
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TEMPORARY STABILITY OF THE STRUCTURE DURING TRANSPORTATION,
INCLUDING SERVICEABILITY DESIGN VERIFICATION.
3. THESE ENGINEERING DRAWINGS HAVE BEEN PREPARED FROM INFORMATION AVAILABLE AT THE TIME OF ISSUE. AS THIS INFORMATION MAY BE
SUBJECT TO CHANGE PRIOR TO OR DURING CONSTRUCTION, THE CONTRACTOR IS TO ADVISE THE ENGINEER WHERE DISCREPANCIES OCCUR.
3. THE CONTRACTOR SHALL BE RESPONSIBLE FOR DAMAGES TO ARCHITECTURAL FINISHES THAT OCCUR DURING TRANSPORTATION.
8.2.1 WELDING SYMBOLS AND THEIR LOCATION SIGNIFICANCE
THE CONTRACTOR SHALL SUBMIT THE DESIGN DOCUMENTATION AND METHOD STATEMENT FOR ALL TRANSPORTATION
4. ANY TEMPORARY WORKS REQUIRED FOR THE ERECTION OF THE STEELWORK IS THE RESPONSIBILITY OF THE STEELWORK PLUG OR BUTT WELDS
4. PROCEDURES TO THE CLIENT FOR REVIEW AND COMMENT. THE CLIENT AND/OR CLIENT'S ENGINEERS SHALL COMMENT ON THE LOCATION
CONTRACTOR. THE STEELWORK CONTRACTOR MAINTAINS RESPONSIBILITY OF THE TEMPORARY WORKS FOR THE STRUCTURE UNTIL FILLET SLOT
DESIGN FOR TRANSPORTATION AND METHOD STATEMENT WITHOUT RELIEVING THE CONTRACTOR OF THEIR SOLE SIGNIFICANCE SQUARE VEE BEVEL U I
THE STRUCTURE IS ERECTED IN ITS ENTIRETY IN ACCORDANCE WITH THE DESIGN DRAWINGS. THE TEMPORARY WORKS SHALL BE
RESPONSIBILITY FOR THE TEMPORARY DESIGN FOR TRANSPORTATION AND ARCHITECTURAL FINISHES.
DESIGNED BY A SUITABLY QUALIFIED STRUCTURAL ENGINEER AND DESIGN DRAWINGS AND CALCULATIONS SHALL BE PROVIDED TO
THE ENGINEER FOR REVIEW AND APPROVAL. ARROW SIDE

5. SHOP DRAWING AND FABRICATION DRAWING DEVELOPMENT TO BE PERFORMED BY CONTRACTOR.


OTHER SIDE
6. CLASH DETECTION AND COORDINATION OF TEMPORARY WORKS AND PERMANENT WORKS TO BE PERFORMED BY CONTRACTOR.

7. THE CONTRACTOR SHALL CHECK OR OBTAIN ALL DIMENSIONS RELEVANT TO SETTING OUT OF SITE WORKS.
6.0 DETAILING AND FABRICATION BOTH SIDES NOT USED

8. WHERE STRUCTURAL CERTIFICATION IS REQUIRED, IT MAY BE REQUESTED AND PERFORMED BY A DULY APPOINTED INSPECTOR FROM 'ROBERT 1. FABRICATE & ERECT STRUCTURAL STEELWORK IN ACCORDANCE WITH AISC CODE OF PRACTICE AND THE PROJECT
SPECIFICATION FOR CONSTRUCTION OF STRUCTURAL STEEL. SUPPLEMENTARY SYMBOLS
BIRD GROUP' (RBG). THE INSPECTOR IS TO BE GIVEN A MINIMUM OF 5 DAYS NOTICE.
WELD ALL SITE WELD BACKING
9. ALL PROPRIETARY ITEMS ARE TO BE INSTALLED STRICTLY IN ACCORDANCE WITH MANUFACTURER SPECIFICATIONS. 2. THE CONTRACTOR SHALL SUBMIT DETAILED, ENGINEERED AND COORDINATED, SHOP DRAWINGS FOR ALL STRUCTURAL STEEL
ROUND STRIP
TO RBG FOR REVIEW PRIOR TO THE START OF FABRICATION AND/OR ERECTION. THE ENGINEER TO INSPECT AND APPROVE ALL
10. MEMBERS HAVE BEEN SIZED TO ACHIEVE MINIMUM CLEARANCE; THE STRUCTURAL ENGINEER’S PERMISSION IS REQUIRED PRIOR TO INTRODUCING FABRICATION WORKS.
BEAM CONNECTIONS WITH DEPTHS LARGER THAN THE STRUCTURAL BEAM DEPTHS.
3. THE CONTRACTOR SHALL SUBMIT TO RBG SURVEY DATA FOR ALL EXISTING CONCRETE CONDITIONS TO RECEIVE STRUCTURAL
11. DESIGN LIFE STEEL ELEMENTS, AND THE CONTRACTOR SHALL FIELD VERIFY ALL SUCH CONDITIONS PRIOR TO THE START OF STEEL
CONTOUR
INSTALLATION. IF EXISTING CONDITIONS DIFFER FROM THOSE ON THE DESIGN DRAWINGS, THE CONTRACTOR SHALL SUBMIT,
- THE STEEL STRUCTURE OF THE BIG BEAST STRUCTURE IS DESIGNED FOR 50 YEARS DESIGN LIFE. MAINTENANCE STRATEGY TO BE FOR REVIEW, REVISED SHOP DRAWINGS INDICATING REQUIRED MODIFICATIONS TO THE ORIGINAL DESIGN AND TO THE FLUSH CONVEX CONCAVE
DEVELOPED TO MAINTAIN THE DESIGN LIFE. CONTRACTOR'S ORIGINAL DRAWINGS.

2.0 STRUCTURAL DESIGN CODES, STANDARDS & REFERENCES 7.0 STRUCTURAL STEEL FINISH SYMBOLS PREPARATION ANGLE; INCLUDED
1. SBC 301-18: "SAUDI BUILDING CODE FOR LOADS & FORCE REQUIREMENTS" 2018. ANGLE OF COUNTERSINK FOR
1. UNLESS NOTED OTHERWISE, ALL STRUCTURAL STEEL SECTIONS, HOT ROLLED PLATES & FLATS SHALL BE GRADE S355 OR PLUG WELDS
CONTOUR SYMBOLS
2. SBC 306-18: "SAUDI BUILDING CODE FOR STEEL STRUCTURES" 2018. EQUIVALENT AS PER BRITISH STANDARDS.
ROOT GAP:DEPTH OF FILLING LENGTH OF WELD
3. ASCE 7-10: "MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES” 2010 BY AMERICAN SOCIETY OF CIVIL 2. STEEL PLATE SUBGRADES SHALL BE PER BS5950 AND EN 1993-1-10: 2005 OR EQUIVALENT.
FOR PLUG AND SLOT WELDS
ENGINEERS.
3. THE STEELWORK CONTRACTOR SHALL NOT SUBSTITUTE SPECIFIED STRUCTURAL STEEL SECTIONS WITHOUT THE APPROVAL OF F PITCH (CENTRE TO
4. AISC 360-10: "DESIGN SPECIFICATION FOR STRUCTURAL STEEL BUILDINGS" 2010 BY AMERICAN SOCIETY OF CIVIL THE STRUCTURAL ENGINEER. DESIGN THROAT THICKNESS
A CENTRE SPACING) OF WELD
ENGINEERS. ANY ADDITIONAL REQUIREMENTS PER LOCAL REGULATIONS FOR ALL WORK SHALL BE MET.
4. MEMBERS SHALL BE FABRICATED USING SINGLE LENGTH SECTIONS. MEMBERS FABRICATED USING SHORT LENGTHS OF SECTIONS DEPTH OF PREPARATION; SIZE OR R
5. ACI 318-11: "BUILDING CODE REQUIREMENTS FOR REINFORCED CONCRETE" 2008, BY THE AMERICAN CONCRETE INSTITUTE. SHALL NOT BE USED WITHOUT THE APPROVAL OF THE STRUCTURAL ENGINEER. STRENGTH FOR CERTAIN WELDS SITE WELDSYMBOL

ARROW OTHER
BOTH SIDES

SIDE SIDE
6. ASCE 37-02: "DESIGN LOADS ON STRUCTURES DURING CONSTRUCTION" 2014 BY AMERICAN SOCIETY OF CIVIL ENGINEERS. 5. HOT FORMED AND COLD FORMED SECTIONS ARE NOT DIRECTLY INTERCHANGEABLE. IT IS TO BE ASSUMED THAT ALL SECTIONS SPECIFICATION,PROCESS, } L-P
SPECIFIED ON THE CONTRACT DOCUMENTATION ARE HOT FORMED, UNLESS STATED OTHERWISE. PROCEDURE OR OTHER S(D) { A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
REFERENCE T ARROW CONNECTING
6. ANY FABRICATION COMPLETED PRIOR TO APPROVAL OF THE RELEVANT SHOP DRAWINGS IS AT THE STEELWORK CONTRACTORS { REFERENCE LINE TO ARROW Rev Revision Description By App Date
RISK. NO STEELWORK SHALL BE ERECTED WITHOUT APPROVAL OF THE RELEVANT SHOP DRAWINGS. } SIDE MEMBER OF JOINT SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
TAIL OMITTED WHEN accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
7. ALL STEEL WORK DETAILING, FABRICATION AND ERECTION TO BE IN ACCORDANCE WITH THE LATEST REVISION OF AISC 360 REFERENCE IS NOT USED (N) You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
8. ANY PAINTED STEEL TO BE SAND BLASTED AT NEW CONNECTION POINTS BEFORE WELDING. REFERENCE LINE or data supplied or transferred by electronic means and you release RBG from any liability for any loss or

3.0 DIMENSIONS AND LEVELS 9. ALL MEMBERS CENTROIDS AT JOINTS SHOULD BE COINCIDENT UNO.
BASIC WELD SYMBOLS
OR DETAIL REFERENCE NUMBER OF SPOTOR
damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
PROJECTION WELDS terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
1. SETTING OUT TO BE PERFORMED BY CONTRACTOR. 10. WHERE GRADE S355 IS SPECIFIED, THE PARTICULAR QUALITY GRADE FOR EACH ELEMENT SHALL BE AS FOLLOW: all intellectual property rights in any information supplied by RBG are owned by, or
NOTE: licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.
2. PRINTED DRAWINGS SHALL NOT BE SCALED TO OBTAIN DIMENSIONS, SIZES ETC. a. S355 JR FOR MATERIAL OF THICKNESS ≤ 25mm. a. THE LETTERS CP IN THE TAIL OF THE ARROW INDICATE A COMPLETE PENETRATION BUTT WELD.
DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
3. ALL DIMENSIONS ARE IN MILLIMETRES UNO. b. THE TAIL SHOULD BE OMITTED IF NO REFERENCE 'T' IS REQUIRED. REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
b. S355 JO FOR MATERIAL OF THICKNESS >25mm, ≤ 45mm.
Structural, Civil & Construction
4. ALL LEVELS ARE EXPRESSED IN METERS UNO. c. S355 J2G3 FOR MATERIAL OF THICKNESS >45mm, ≤ 100mm. c. THE SIZE OF A FILLET WELD SHALL BE TO THE LEFT OF THE SYMBOL. Engineering Consultant

5. ONLY WRITTEN DIMENSIONS SHALL BE FOLLOWED. IN CASE OF MISSING DIMENSIONAL INFORMATION, THIS SHALL BE PREFERABLY
DERIVED MATHEMATICALLY FROM OTHER AVAILABLE DATA AND CONFIRMATION SHALL BE SOUGHT FROM CONSULTANT. IN CASE
OF ABSENCE OF DATA, RBG SHALL BE CONTACTED FOR CONFIRMATION.
d. S355 JO FOR ROLLED HOLLOW SECTIONS OF THICKNESS ≤ 45mm. d. FOR AN INCOMPLETE PENETRATION BUTT WELD, THE DESIGN THROAT THICKNESS SHALL BE TO THE LEFT OF THE
SYMBOL. WHERE NO DESIGN THROAT THICKNESS IS SHOWN, A COMPLETE PENETRATION BUTT WELD IS ASSUMED REQUIRED.
Robert BirdGroup
11. NO SITE WELDING OR SITE CUTTING OF STEELWORK SHALL BE ALLOWED WITHOUT THE EXPRESS APPROVAL OF Member of the Surbana Jurong Group
THE ENGINEER, U.N.O. e. ARROW SIDE AND OTHER SIDE WELDS ARE MADE THE SAME SIZE UNLESS OTHERWISE DIMENSIONED. DUBAI OFFICE
6. FOR MAIN SETTING OUT LINES AND LEVELS REFER TO TOPO SURVEY.
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
12. ALL STRUCTURAL STEELWORK SHALL BE CORROSION PROTECTED IN ACCORDANCE WITH THE FOLLOWING PERFORMANCE f. SYMBOLS ONLY APPLY BETWEEN ABRUPT CHANGES IN DIRECTION OF WELDING UNLESS GOVERNED BY THE 'WELD ALL Ibn Battuta Gate Email: MENA@robertbird.com.au
7. FOR OBTAINING ACCURATE BARE STRUCTURAL LEVELS, REFER ARCHITECTURAL DETAILS AND NOTES REGARDING FINISHES, SCREEDS SPECIFICATION: ROUND' SYMBOL OR OTHERWISE DIMENSIONED. Level 4, Office Suite 415 Web: www.robertbird.com
ETC. Jebel Ali, Dubai
PO Box 118570
- CORROSIVITY CATEGORY C3 AS PER ISO 12944-2 TABLE 1. Dubai, United Arab Emirates TRADE LICENCE 597197
8. LEVELS WILL BE TAKEN CONSIDERING THE PROJECT DATUM. - LIFE TO FIRST MAINTENANCE TO BE MIN 20 YEARS.
- TESTING IS REQUIRED TO ISO 9223 TO CONFIRM CORROSIVITY CATEGORY EXTRACTED FROM ISO 12944-2 TABLE 1.
STEELWORK LEGEND Client

9. ALL DISCREPANCIES IN DIMENSIONS SHALL BE REFERRED TO RBG FOR A DECISION BEFORE PROCEEDING WITH THE WORK
- ANY DAMAGE TO PAINT SYSTEMS DURING INSTALLATION MUST BE TOUCHED UP ON SITE TO THE REQUIRED SPECIFICATION.
STEEL BEAM SCHEDULE KEY:
MDLBEAST
ALL EXPOSED STEELWORK TO BE RECEIVE CORROSION PROTECTION AS PER THE FOLLOWING REQUIREMENTS
END MOMENT PRE-CAMBER END MOMENT
10. THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROPER SETTING OUT OF WORKS, FOR CORRECTNESS OF POSITION, LEVELS AND 13. - PRIMER/ MIDCOAR MIN 100 - 150µm DFT (PENGUARD EXPRESS ZP OR SIMILAR) (LEFT) (RIGHT)
ALIGNMENTS OF ALL PARTS OF THE WORKS, QUALITY & FINISHES. 00
- TOP COAT MIN 80 - 100µm DFT (FUTURA CLASSIC OR SIMILAR). 000 BEAM REFERENCE 000
IF AT ANY TIME AN ERROR IS DETECTED, THE CONTRACTOR SHALL RECTIFY. THE CHECKING ENGINEER SHALL NOT RELIEVE THE - TOP COAT TO BE POLYURETHANE BASED COAT
CONTRACTOR FROM IS RESPONSIBILITY. - ALL STEELWORK TO BE PAINTED IN RAL 7024 COLOUR 00 000 00 Project
000
11. ANY DISCREPANCIES SHALL BE BROUGHT TO THE ATTENTION OF THE ENGINEER BEFORE PROCEEDING WITH THE PORTION OF WORK. SECONDARY STEELWORK: END REACTION PERMANENT ROBUST END REACTION SOUNDSTORM 2023
(LEFT) TIE FORCE TIE FORCE (RIGHT)
14. STEELWORK CURRENTLY NOT SHOWN, SUBJECT TO FURTHER COORDINATION & DETAILING WITH OTHER TRADES. THERE
WILL BE ITEMS WITHIN THE STEEL FABRICATOR SCOPE THAT ARE NOT IN THE RBG SCOPE INCLUDING DESIGN/ STEEL COLUMNS
4.0 ERECTION ("CONTRACTOR" IN THIS SECTION REFERS TO THE CONTRACTOR RESPONSIBLE FOR INSTALLATION COORDINATION/ FIXING OF OTHER TRADE CONTRACTORS ITEMS BACK TO THE PRIMARY STEEL FRAME, I.E.

??
OF THE STRUCTURES) ACADE/CLADDINGS, FACADE ACCESS, ARCHITECTURAL METALWORK ETC. THE STEELWORK TRADE CONTRACTOR SHALL DENOTES COLUMN NUMBER

HO C?-?
DENOTES COLUMN SECTION
??
CO C?-?

PROACTIVELY COORDINATE WITH OTHER TRADE CONTRACTORS TO UNDERSTAND THE PROVISIONS REQUIRES TO (COLUMN OVER, FROM TOP OF REFERENCE (HANGER OVER)

S
1. ERECTION TOLERANCES FOR STRUCTURAL STEELWORK TO BE AS PER AISC 360
S

ACCOMMODATE ELEMENTS THAT INTERFACE WITH THE PRIMARY STEEL. BEAM FLANGE) Title
DENOTES COLUMN SECTION
BIG BEAST STAGE COVER GENERAL

??
DENOTES COLUMN NUMBER

HU C?-?
2. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CONTROL OF ALL ERECTION PROCEDURES AND SEQUENCES ESPECIALLY WITH
??

SITE CONNECTIONS: REFERENCE (HANGER UNDER)


CU C?-?

(COLUMN CAPPED AT BEAM NOTES SHEET 1

S
RELATION TO TEMPERATURE DIFFERENTIALS AND ERECTION TOLERANCES.
S

SOFFIT LEVEL)
15. THE STEELWORK CONTRACTOR SHALL CLEARLY IDENTIFY THE LOCATION OF SITE CONNECTIONS ON THE MARKING PLANS
3. ALL ERECTION PROCEDURES, DESIGNS, AND CALCULATIONS SHALL BE PERFORMED BY A QUALIFIED STRUCTURAL ENGINEER AND TOGETHER WITH DETAILS OF, AND CALCULATIONS FOR, THOSE CONNECTIONS. DENOTES COLUMN NUMBER
??

SUBMITTED TO RBG FOR REVIEW AND APPROVAL. ANY REVIEW OF SUCH CALCULATIONS AND/OR DRAWINGS BY THE ENGINEER WILL (COLUMN OVER COLUMN
?-?

BE SOLELY LIMITED TO ANY EFFECTS ON THE INTEGRITY OF THE ELEMENTS SHOWN ON THESE DRAWINGS
SC

UNDER)
Date Drawn
DENOTES COLUMN NUMBER
??

4. VERTICAL DISPLACEMENT AND MOVEMENTS DURING ERECTION ARE TO BE LIMITED TO ENSURE THE STRUCTURE IS NOT SUBJECTED 02/06/23 Jo.Na
CC C?-?

TO LOADS OR MOVEMENTS CAUSING STRUCTURAL DISTRESS TO ANY ELEMENT WHILE THE STRUCTURE IS BEING TRANSPORTED OR (COLUMN CAPPED AT TOP OF Scale at A1 Designer
S

TEMPORARILY SUPPORTED. BEAM LEVEL)


As indicated Ma.Ch
STEELWORK Design Checker
5. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE TEMPORARY STABILITY DESIGN OF THE STRUCTURE DURING LIFT/INSTALLATION,
INCLUDING BUT NOT LIMITED TO STRUCTURAL DESIGN VERIFICATION, TEMPORARY STABILITY AND SERVICEABILITY DESIGN GENERAL ARRANGEMENT LEGEND: Ja.Hu
VERIFICATION. Approved
DENOTES MOMENT VB DENOTES VERTICAL Ra.Ma
CONNECTION BRACING ABOVE/BELOW

02/06/2023 6:21:05 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-00002 A02


7.3 STRUCTURAL BOLTS
c 100% OF ALL 100mm OR THICKER PLATES.

ST
AG
1. ALL BOLTS, NUTS AND WASHERS SHALL CONFIRM TO THE REQUIREMENTS OF ISO 898-1 OR BS

E
D
C
G

D
C

G
G
G
G
4190 FOR GRADE 10.9 METRIC BOLTS OF MATERIAL STEEL AISI 4140, QUENCHED AND TEMPERED
D
C

d. 20% OF EMBEDDED PLATES, SELECTED AT RANDOM, OVER THE FULL AREA.


(U) UNLESS NOTED OTHERWISE.
5. 100% OF ALL BOLTED CONNECTIONS SHALL BE VISUALLY INSPECTED, AND THEN TESTED WITH
2. BOLTS DESIGNATION - EXAMPLE: 4 M20 10.9/TB
ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
A CALIBRATED TORQUE WRENCH TO VERIFY A MINIMUM OF 25% OF BOLTS IN EACH
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

CONNECTION (2 BOLTS PER CONNECTION MINIMUM).


NUMBER OF BOLTS -4
SIZE M20 - 20mm DIA BOLT 6. THE REQUIRED SURFACE CONTACT CONDITIONS OF ALL SHEAR CONNECTIONS SHALL BE KEY PLAN
GRADE OF BOLTS - 10.9 VISUALLY INSPECTED IMMEDIATELY PRIOR TO BEAM ERECTION, ESPECIALLY AT ALL SHOP
TIGHTENING/S - SNUG TIGHTENING CLEANED, PRIMED SURFACES. THE CONTRACTOR SHALL BE RESPONSIBLE FOR ALL REMEDIAL
TIGHTENING PRE-LOADED - FULLY TENSIONED BEARING TYPE CONNECTION WORK REQUIRED TO CONTACT SURFACES.
3. ALL BOLTS SHALL BE INSTALLED IN ACCORDANCE WITH AISC STANDARDISED STRUCTURAL 7. THE STRUCTURAL STEEL FABRICATOR AND ERECTOR SHALL SCHEDULE ALL WORK TO ALLOW
CONNECTIONS PART A. THE ABOVE INSPECTION AND TESTING REQUIREMENTS TO BE COMPLETED.
4. UTILIZE GRADE 10.9 BOLTS TO BS 3692 OR BS 4190, MINIMUM DIAMETER 16mm UNLESS NOTED 8. CONTRACTOR IS REQUIRED TO SUBMIT ALL TESTING DOCUMENTATION AND CERTIFICATES TO
OTHERWISE, WITH A MINIMUM OF TWO BOLTS PER CONNECTIONS. THE CLIENT FOR REVIEW BY THE CLIENT ENGINEER PRIOR TO INSTALLATION AND HAND OVER
TO THE CLIENT.
5. STANDARD CLEARANCE HOLES TO BE USED UNLESS NOTED OTHERWISE.

6. ALL BOLT HOLES SHALL BE DRILLED (REAMED ONLY WHERE REQUIRED AND APPROVED BY THE
STRUCTURAL ENGINEER) EXCEPT WHERE NOTED.
PRE-LOADED BOLT INSTALLATION
1. MINIMUM BOLT TENSION 8.0 CONCRETE NOTES (FOR BALLAST BLOCKS)
IN THE COMPLETED CONNECTION, ONLY WHERE SPECIFIED ON THE DRAWINGS, ALL PRE-LOADED 1. UNLESS NOTED OTHERWISE, ALL CONCRETE SHALL HAVE A MINIMAL STRENGTH OF F’C = 25MPa.
BOLTS SHALL HAVE AT LEAST THE MINIMUM BOLT TENSION SPECIFIED IN THE TABLE BELOW WHEN
ALL BOLTS IN THE BOLT GROUP ARE TIGHTENED. THE TABLE BELOW IS BASED ON GRADE 8.8 AND 2. PROVIDED CONCRETE SHALL HAVE A NORMAL CONCRETE WEIGHT WITH A CURED DENSITY OF 23.5kN/m3+/- 0.5KN/m3.
10.9 BOLTS.
3. CONCRETE COVER OF 40MM UNLESS NOTED OTHERWISE.

MINIMUM BOLT TENSION 4. REINFORCEMENT TO BE GRADE MIN 460MPa.

NOMINAL DIAMETER OF BOLT MINIMUM BOLT TENSION 5. WHERE A 90-DEG, 135-DEG OR 180-DEG HOOK IS GRAPHICALLY INDICATED, PROVIDE CORRESPONDING ACI STANDARD HOOKS
UNLESS NOTED OTHERWISE.
M16 95kN
6. UNLESS OTHERWISE NOTED ALL LAP SPLICES MUST HAVE A MINIMUM LAP OF 50 x BAR DIAMETER.
M20 145kN
M24 210kN 7. ALL CONCRETE SHALL BE CURED IN ACCORDANCE WITH THE INTERNATIONAL AND LOCAL STANDARDS.
M30 335kN
M36 490kN 8. ALL CONCRETE SHALL BE SAMPLED AND TESTED IN ACCORDANCE WITH INERNATIONAL AND LOCAL STANDARDS.

2. METHODS OF TENSIONING PRE-LOADED BOLTS

DUE TO THE ROUGH SURFACE FINISH EXPECTED ON BOLTED STRUCTURAL ELEMENTS, TENSIONING
BASED ON TORQUE CONTROL METHOD IS NOT ACCEPTED ON THIS PROJECT. PRE-LOADED BOLTS
SHALL BE TENSIONED. USING DIRECTION TENSION INDICATORS SUCH AS DTI WASHERS AND/OR
HYDRAULIC TENSIONERS. 9.0 HEALTH AND SAFETY
TENSIONING BY USE OF DIRECT-TENSION 1. THE CONTRACTOR IS RESPONSIBLE FOR THE SAFETY OF THE WORKERS AT ALL TIMES, AND SHALL IMPLEMENT A SITE SAFETY
POLICY IN ACCORDANCE WITH LOCAL MUNICIPALITY REQUIREMENTS.
TENSIONING OF BOLTS USING A DIRECT-TENSION INDICATION DEVICE SHALL BE IN ACCORDANCE
WITH THE FOLLOWING PROCEDURE: 2. THE CONTRACTOR SHALL DEVELOP, IMPLEMENT AND ADMINISTER A WORKPLACE HEALTH AND SAFETY PROGRAM THAT WILL
ENSURE THAT ALL CONSTRUCTION ACTIVITIES ARE PERFORMED TO THE RELEVANT WORKPLACE HEALTH AND SAFETY
a. THE SUITABILITY OF THE DEVICE SHALL BE DEMONSTRATED BY TESTING A REQUIREMENTS AND ANY OTHER RELEVANT STATUTORY REQUIREMENTS.
REPRESENTATIVE SAMPLE OF NOT LESS THAN THREE BOLTS FOR EACH DIAMETER
AND GRADE OF BOLT IN A CALIBRATION DEVISE CAPABLE OF INDICATING BOLT 3. THE WORKPLACE HEALTH AND SAFETY PROGRAM MUST BE COORDINATED WITH ADJOINING PROPERTY OWNERS AND ALL
TENSION NOT LESS THAN 1.05 TIMES THE MINIMUM BOLT TENSION SPECIFIED IN ITEM 1. RELEVANT PARTIES AS NECESSARY TO ENSURE A SAFE BUILDING ENVIRONMENT AT ALL TIMES.

b. ON ASSEMBLY, ALL BOLTS AND NUTS IN THE CONNECTION SHALL BE FIRST TIGHTENED
TO A SNUG-TIGHT CONDITION.
10.0 UNITS
1. SI METRIC UNITS ARE USED THROUGHOUT THE DESIGN AND CALCULATION
c. AFTER COMPLETING SNUG-TIGHTENING, THE BOLT SHALL BE TENSIONED TO PROVIDE THE
MINIMUM BOLT TENSION SPECIFIED IN ITEM 1. THIS SHALL BE INDICATED BY THE
TENSION INDICATION DEVICE.

NOTE: A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
THE TENSIONING OF BOLTS USING A DIRECT-TENSION DEVICE SHALL ALSO BE IN ACCORDANCE Rev Revision Description By App Date
WITH THE MANUFACTURE'S SPECIFICATION. SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

7.4 TESTING AND INSPECTION You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
1. THE CONTRACTOR SHALL ENGAGE A QUALIFIED STRUCTURAL STEEL MATERIALS TESTING with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
AGENCY, ACCEPTABLE TO THE OWNER, TO CONTINUOUSLY PERFORM ALL REQUIRED SHOP terms of engagement for the project which must not be used for any other purpose. The
FABRICATION AND FIELD ERECTION TESTING AND INSPECTIONS, INCLUDING AT LEAST ALL OF information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
THE FOLLOWING ITEMS. IT IS REQUIRED THAT THE STRUCTURAL STEEL FABRICATOR AND licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
STRUCTURAL STEEL ERECTOR ARE BS CERTIFIED, OR CERTIFIED BY OTHER ACCEPTABLE licence to use the intellectual property rights for the express purpose.

INTERNATIONAL NORMS. THE OWNER'S STRUCTURAL STEEL TESTING AGENCY MAY ALSO MAKE DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
ADDITIONAL INSPECTIONS AND TESTS, AT THE DISCRETION OF THE OWNER, WITH SUCH TESTS REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
AND INSPECTIONS NOT RELIEVING THE CONTRACTOR OF HIS SOLE RESPONSIBILITY OF QUALITY
Structural, Civil & Construction
CONTROL AND QUALITY ASSURANCE OF ALL WORK. TESTING AND INSPECTION OF BOTH SHOP Engineering Consultant
AND FIELD STRUCTURAL STEEL FABRICATION AND ERECTION WORK, INCLUDING WELDED AND
BOLTED CONNECTIONS, SHALL BE AS FOLLOWS:

a. ALL STRUCTURAL STEEL FABRICATION AND ERECTION SHALL BE VISUALLY INSPECTED


Robert BirdGroup
Member of the Surbana Jurong Group
100%.
DUBAI OFFICE
b. ALL WELDERS SHALL BE AWS CERTIFIED, OR EQUIVALENT BRITISH STANDARD. Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
c. ALL WELDS SHALL BE BS OR AWS/AISC PRE QUALIFIED. Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
d. ALL WELDS SHALL BE VISUALLY INSPECTED 100% PER AWS D1.1. WELD SIZE AND
CONFIGURATION MEASUREMENTS SHALL BE PERFORMED FOR A MINIMUM OF 15% OF Client
ALL WELDS ON A RANDOM BASIS.
MDLBEAST
2. MAGNETIC PARTICLE TESTING IN ACCORDANCE WITH EQUIVALENT BRITISH STANDARD OR
ASTM E709,SHALL BE PERFORMED FOR A MINIMUM OF:

a. 10% OF ALL FILLET WELDS CHOSEN AT RANDOM, FINAL PASS ONLY.

b. 10% OF ALL SHEAR PLATE FILLET WELDS, CHOSEN AT RANDOM, FINAL PASS ONLY.
Project
c. 20% OF ALL CONTINUITY PLATE FILLET WELDS, CHOSEN AT RANDOM, FINAL PASS
ONLY. SOUNDSTORM 2023
d. 100% OF ALL OF THE FOLLOWING MEMBERS AND CONNECTIONS FOR FILLET/PARTIAL
PENETRATION WELDS, FOR ROOT AND FINAL PASSES:

• TENSION MEMBER CONNECTIONS.


• BUILT-UP MEMBER PARTIAL PENETRATION WELDS. Title
• BUILT-UP MEMBERS IN ZONES OF MOMENT CONNECTIONS.
• BASE PLATE ASSEMBLIES. BIG BEAST STAGE COVER GENERAL
3. ULTRASONIC TESTING IN ACCORDANCE WITH AWS D1.1 OR EQUIVALENT BRITISH STANDARD,
NOTES SHEET 2
SHALL BE PERFORMED FOR A MINIMUM OF:

a. 100% OF ALL FULL PENETRATION WELDS.


Date Drawn
b. 20% OF ALL SPLICE WELDS, CHOSEN AT RANDOM.
02/06/23 Jo.Na
Scale at A1 Designer
4 ULTRASONIC TESTING AND VISUAL INSPECTION IN ACCORDANCE WITH ASTM A435, OR
EQUIVALENT BRITISH STANDARD, SHALL BE UTILIZED TO VERIFY BASE MATERIALS FOR 1:1 Ma.Ch
LAMINATIONS, INCLUSIONS, OR OTHER DISCONTINUITIES IN THE FOLLOWING AREAS AS A Design Checker
MINIMUM: Ja.Hu
Approved
a. MOMENT CONNECTIONS WHERE ANY FLANGE EXCEEDS 40mm IN THICKNESS. THE Ra.Ma
TEST AREA SHALL EXTEND 150mm IN ANY DIRECTION FROM THE END OF EACH WELD

02/06/2023 6:21:06 PM
WITH 100% SCANNING OF THE TEST AREA.

b. BUILT-UP MEMBERS WITH FLANGE PLATES GREATER THAN 50mm IN THICKNESS. THE
FOR TENDER
TEST AREA SHALL INCLUDE THE MIDDLE ONE-THIRD OF THE BEAM OR COLUMN Drawing Number Revision
LENGTH AND A MINIMUM OF 900mm AT EACH END OF THE BEAM WITH 100%
SCANNING OF THE TEST AREA. M9307-RBG-PS007-ZZ- DR-ST-00003 A02
4.1.1 GRAVITY LOADS

ST
AG
E
BASIS OF DESIGN AND PERFORMANCE CRITERIA 1. GRAVITY LOADS SHALL INCLUDE SELF-WEIGHT OF THE STRUCTURE (WITH AN APPROPRIATE ALLOWANCE FOR ALL CONNECTIONS
6.0 STRUCTURAL PERFORMANCE REQUIREMENTS

D
C
G

D
C

G
G
G
G
D
C

AND FIXING DETAILS), SUPERIMPOSED DEAD LOADS (CLADDING MATERIALS, MEP EQUIPMENT, OR ANY OTHER PERMANENT
LOADS THAT WILL BE ATTACHED TO THE STRUCTURE), LIVE LOADS (CONSIDERING CROWD LOADS, SERVICES OR ANY SEMI-
1. THE FOLLOWING OUTLINES THE VARIOUS DESIGN AND LOADING CRITERIA THAT ARE CONSISTENT WITH THE CLIENT’S PERMANENT OR NON-PRECISELY DEFINED LOADS). 6.1 ULTIMATE LIMIT STATE CRITERIA ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
REQUIREMENTS. COUT NR
C
E IV E
S R
E COUT NR E
C
E IV E
S R
COUT NR
C
E IV E
S R
E

4.1.1.1 DEAD LOADS 1. ALL MEMBERS ARE DESIGNED FOR MAXIMUM 95% UTILIZATION RATIO.
1. SELF-WEIGHT OF THE STRUCTURE SHOULD BE BASED ON THE FOLLOWING MATERIAL DENSITIES:
A. STRUCTURAL STEEL – 7850 KG/M3 WITH 10% ALLOWANCE FOR CONNECTIONS AND SPLICES 6.2 SERVICEABILITY LIMIT STATE CRITERIA KEY PLAN
1.0 DESIGN LIFE B. CONCRETE (FOR BALLAST) – 2450 KG/M3
6.2.1 DEFLECTIONS AND DEFORMATIONS
1. DEFLECTION UNDER LIVE LOAD ALONE IS LIMITED TO MAXIMUN L/360.
1. EVEN THOUGH THE BIG BEAST STAGE STRUCTURE WILL HAVE TEMPORARY NATURE IN TERMS OF THEIR USAGE (AS THEY ARE
INTENDED TO BE USED FOR SPECIFIC EVENTS ACROSS THE YEAR), MATERIAL SPECIFICATIONS SHOULD BE DETERMINED 2. SUPERIMPOSED DEAD LOAD SHOULD BE CONSIDERED AS PER THE FOLLOWING:
CONSIDERING 50-YEAR DESIGN LIFE. A. ROOF CLADDING – 50 KG/M2
6.2.2 DIFFERENTIAL SETTLEMENT
B. SIDE CLADDING - 100 KG/M2. 1. MAXIMUM 25MM OR L/1000 (WHERE L IS THE DISTANCE TO THE ADJACENT COLUMN), WHICH EVER IS SMALLER, DIFFERENTIAL
2.0 DESIGN CODES AND REFERENCES 4.1.1.2 LIVE LOADS
SETTLEMENT IS ALLOWED IN THE DESIGN.

1. VIB AREAS LIVE LOAD – 5.0 KPA 6.2.3 VIBRATION


TEMPORARY DEMOUNTABLE STRUCTURES (GUIDANCE ON PROCUREMENT, DESIGN AND IT SHOULD BE NOTED THAT THE LIVE LOAD REDUCTION PROPOSED WITH ASCE 7-16 SHALL NOT BE APPLIED AS THE DESIGN
IStructE
USE) LOADS EXCEED 4.8KPA AND THE VIB AREAS ARE EXPECTED TO BE OVERCROWDED AT CERTAIN TIMES. 1. ACCORDING TO “DESIGN GUIDE 11: VIBRATIONS OF STEEL-FRAMED STRUCTURAL SYSTEMS DUE TO HUMAN ACTIVITY (SECOND
DEMOUNTABLE EDITION)”, THE STRUCTURE SUPPORTING THE VIB AND MEP AREAS ARE DESIGNED TO MINIMUM FUNDAMENTAL FREQUENCY FOR
STRUCTURES ANSI ENTERTAINMENT TECHNOLOGY - TEMPORARY STRUCTURES USED FOR TECHNICAL 2. MEP PLANT LIVE LOAD - 7.5KPA THE FLOOR OF 4HZ (TBC).
1.21-2013 PRODUCTION OF OUTDOOR ENTERTAINMENT EVENTS
3. BALUSTRADE LOAD – 2.0 KN/M
SBC 306-18 STEEL STRUCTURES
STEELWORK SPECIFICATION FOR STRUCTURAL STEEL BUILDING DESIGN FOR DESIGN OF STEEL NOTE: THESE LOADS ARE YET TO BE CONFIRMED ONCE THE FINISHES OF THE STRUCTURE ARE CONFIRMED BY THE CLIENT.
AISC 360-16
ELEMENTS, BY THE AMERICAN INSTITUTE OF STEEL CONSTRUCTION
6.2.4 ROBUSTNESS
SBC 301-18 SAUDI BUILDING CODE FOR LOADS & FORCE REQUIREMENTS 1. THE STRUCTURE IS DESIGNED TO ENSURE THAT NEITHER THE WHOLE BIG BEAST STAGE STRUCTURE NOR A SIGNIFICANT PART OF
4.1.1.2 WIND IT WILL COLLAPSE UNDER THE CASE OF LOCALISED FAILURE.
LOADS – GENERAL ASCE 07-16 MINIMUM DESIGN LOADS FOR BUILDINGS AND OTHER STRUCTURES
1. CONSIDERING THE NATURE OF THE BIG BEAST STAGE, TWO DIFFERENT SCENARIOS HAVE BEEN CONSIDERED FOR THE WIND LOAD
BD 37/01 APPLICATION. 6.2.5 DURABILITY
DESIGN MANUAL FOR ROADS AND BRIDGES – LOADS FOR HIGHWAY BRIDGES
(WHERE APPLICABLE)
1. THE EXTREME CLIMATE CONDITIONS IN THE GULF REGION AND THE PRESENCE OF CHLORIDES AND SULPHATES IN THE GROUND
A. TEMPORARY USAGE (DURING THE EVENT) - WHEN THE BIG BEAST STAGE IS TREATED AS MANAGED STRUCTURES (THE
MOMRA MINISTRY OF MUNICIPAL & RURAL AFFAIRS IN KSA BRIDGES, TUNNELS, CULVERTS AND AND THE ATMOSPHERE, CREATE ONEROUS REQUIREMENTS FOR CONCRETE DURABILITY WHICH WILL BE ACHIEVED BY ADOPTING
WIND IS COMBINED WITH THE RIGGING LOAD) – DESIGN WIND SPEED OF 25M/S (SERVICE) IS CONSIDERED (33M/S
PEDESTRIAN BRIDGES SPECIFICATIONS IN URBAN AREAS THE FOLLOWING MEASURES:
ULTIMATE WIND SPEED). FOR THIS CASE, FOLLOWING PARAMETERS ARE USED.
BRIDGE CODES - OCCUPANCY CATEGORY: III
DMRB DESIGN MANUAL FOR ROADS AND BRIDGES A. A MINIMUM LOCAL COATING THICKNESS OF 17 MICRONS.
- IMPORTANCE FACTOR = 1.0
(WHERE APPLICABLE) B. STEELWORK SHALL BE PAINTED WITH THE DOTAL DFT OF 325 MICRONS CONFORMING TO ISO 12944-5 TO ACHIEVE THE
ASHTO AMERICAN ASSOCIATION OF STATE OF HIGHWAY TRANSPORTATION OFFICIALS DESIGN LIFE.
B. PERMANENT INSTALLATION – WHICH CONSIDERS BIG BEAST STAGE LEFT IN THEIR PLACE ON SITE BUT NOT BEING
USED BY PUBLIC - DESIGN WIND SPEED OF 40M/S (SERVICE) IS CONSIDERED (54M/S ULTIMATE WIND SPEED).
BS 5400 STEEL, CONCRETE AND COMPOSITE BRIDGES - OCCUPANCY CATEGORY: III
- IMPORTANCE FACTOR = 1.0
1. ANY ADDITIONAL REQUIREMENTS PER LOCAL REGULATIONS FOR ALL WORK SHALL BE MET 7.0 RIGGING
2. OTHER GENERAL PARAMETERS FOR WIND LOAD CALCULATIONS ARE DEFINED AS PER BELOW:
- TOPOGRAPHICAL FACTOR, KZT = 1.00 1. ALL RIGGING MUST BE APPROVED BY ENGINEER OF RECORD.
2. ANY EQUIVALENT ALTERNATIVES TO SPECIFIED STANDARDS SHALL BE DOCUMENTED AND SUBMITTED TO THE ENGINEER FOR
- DIRECTIONALITY FACTOR, KD = 0.85 2. THE ROOF SYSTEM HAS BEEN DESIGNED FOR THE ATTACHED RIGGING LOADS ONLY. IF RIGGING LOADS EXCEED THOSE
APPROVAL.
- EXPOSURE CATEGORY = C INDICATION ON THE ATTACHED PLAN, PLEASE CONTACT MDL BEAST/PG PRODUCTION OR VENUE MANAGEMENT FOR APPROVAL
- GUST FACTOR = 1.0 (THIS IS A CONSERVATIVE APPROACH CONSIDERING THAT THE STRUCTURES WILL BE PROCEDURES.
QUITE FLEXIBLE / WILL HAVE HIGH NATURAL FREQUENCY. IF THE STRUCTURE IS RIGID, 0.85 COULD BE USED
3.0 STRUCTURAL SYSTEM INSTEAD.)
- MAIN WIND-FORCE RESISTING SYSTEM
1. THE BIG BEAST STAGE IS A STEEL STRUCTURE COMPOSED OF TOWER COLUMNS/BEAMS AND TRUSSES. THE STABILITY OF THE 4.1.1.3 SEISMIC
STRUCTURE (IN THE PERMANENT CASE) IS MAINTAINED BY A COMBINATION OF CROSS BRACING AND PORTAL FRAME ACTION. THE 1. THE BIG BEAST STAGE STRUCTURE HAVE NOT BEEN DESIGNED TO WITHSTAND SEISMIC ACTIONS DUE TO ITS TEMPORARY USE
FRONT OPENING OF THE STAGE IS BRIDGED BY A VIERENDEEL TRUSS WHICH ALSO SUPPORTS A 15m SPAN CANTILEVER CANOPY. AND NATURE AND IN ACCORDANCE WITH THE INSTITUTION OF STRUCTURAL ENGINEER'S PUBLICATION "TEMPORARY
DEMONTABLE STRUCTURES: GUIDANCE ON PROCUREMENT, DESIGN AND USE (FOURTH EDITION)".
OVERALL DIMENSIONS:
A. PLAN DIMENSIONS OF ONE SEGMENT = 2.4M X 2.4M. 4.1.1.4 TEMPERATURE
B. MAX. LENGTH OF ONE SEGMENT = 12.0M. 1. THE TEMPERATURE DESIGN PARAMETERS ARE ESTABLISHED WITH REFERENCE TO IAN009.
C. WIDTH OF STRUCTURE = 23.2M.
D. LENGTH OF STRUCTURE = 52M. 2. TEMPERATURE RANGE:
E. MAX. HEIGHT OF STRUCTURE = 34M. -TEMPERATURE INCREASE +25 ºC
F. SPAN OF CANTILEVER CANOPY = 15M. -TEMPERATURE DECREASE -25 ºC

4.1.1.5 RIGGING LOADS (LIVE LOAD) A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
3.1 MATERIALS AS INDICATED IN THE ATTACHED DRAWINGS A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
1. THE MAIN STRUCTURAL ELEMENTS OF THE BIG BEAST STAGE ARE STRUCTURAL STEEL MEMBERS. Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
4.2 LOAD COMBINATIONS accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
1. ULTIMATE LIMIT STATE (ULS) AND SERVICEABILITY LIMIT STATE (SLS) LOAD COMBINATIONS SHOULD BE IN ACCORDANCE WITH matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be

4.0 LOADS AND LOAD COMBINATIONS THE SAUDI BUILDING CODES AND OTHER RELEVANT INTERNATIONAL STANDARDS. liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
4.1 LOAD CASES RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
LOAD CASE SYMBOLS AND NOTATIONS ARE AS INCLUDED BELOW: information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
SYMBOL LOAD DEFINITION licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


DL DEAD LOAD INCLUDING SELF-WEIGHT AND SUPERIMPOSED DEAD LOAD
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
LL LIVE LOAD Structural, Civil & Construction
Engineering Consultant
W WIND LOAD
E
T
EARTHQUAKE LOAD
TEMPERATURE LOAD
Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST

Project

SOUNDSTORM 2023

Title

BIG BEAST STAGE BASIS OF DESIGN


AND PERFORMANCE CRITERIA

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:07 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-00004 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

C D E F G H KEY PLAN

A C K

1 UPPER ROOF
+706.885M

2
LOWER ROOF
+694.085M

3
GROUND FLOOR
+673.485M

TYPICAL ELEVATION
SCALE 1 : 500

4
5 LOADING LEGEND:

3.0x3.0m TRUSS GRID SYSTEM:

A) LOAD CAPACITY 1.0T PER METER PER


TRUSS LINE IN BOTH DIRECTIONS.
B) LOAD CAPACITY 2.10T PER METER PER
TRUSS LINE IN ONE DIRECTION EACH TIME.

UPPER ROOF LOADING PLAN 3.0x3.0m TRUSS GRID SYSTEM:


SCALE 1 : 200
A) LOAD CAPACITY 0.5T PER METER PER
TRUSS LINE IN BOTH DIRECTIONS.
B) LOAD CAPACITY 1.0T PER METER PER
TRUSS LINE IN ONE DIRECTION EACH TIME.

A B C D E F G H J K
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the

1 accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
2 damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

3 Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST
4
5

Project

SOUNDSTORM 2023

Title

BIG BEAST STAGE


6 RIGGING/LOADING PLAN

7
Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
LOWER ROOF LOADING PLAN Approved
SCALE 1 : 200 Ra.Ma

02/06/2023 6:21:22 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-00005 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

A B C D ISOLATION JOINT BETWEN E F SLAB ON GRADE G H J K


GROUND SLAB AND 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

FOUNDATION
3300 2400 8200 2400 3000 8200 3600 8200 3000 2400 8200 2400 3300
KEY PLAN
1000 1000
PF1 S1 PF1
2225

GENERAL NOTES
1 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.
2400

2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN


DIMENSIONS ARE TO BE FOLLOWED.

2 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

10000

10000
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
LOCALIZED DEMOLITION OF EXISTING FOOTINGS TO M9307-RBG-PS007-ZZ-DR-ST-0003.
ALLOW INSTALLATION OF ANCHORING SYSTEM.
1200 AREA TO BE RE-CAST WITH NEW CONCRETE 1200 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
SSL = +673.485m SSL = +673.485m FULLY WELDED AT CONNECTION POINTS.

4000

4000
PAD FOOTING SCHEDULE
5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
MARK LENGTH WIDTH DEPTH REINF. RATE
8900

ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.


PF1 AS PER PLAN 1500 110 Kg / m³
PF2 EXISTING FOOTING 1200 - 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

PF2 PF5 EXISTING FOOTING 1200 -


PF2 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
S1 AS PER PLAN 175 80 Kg / m³ TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
5600 2400 2400 5600 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
1500 1500

3525

3525
175
SSL = +673.485m SSL = +673.485m FOUNDATION LEGEND:
SSL = +673.485m

3 NEW FOUNDATION EXTENSION

28785

28785
EXISTING FOUNDATION
9000 2500
2500 9000 SLAB ON GRADE

NOTE:
THE CALIFORNIA BARING RATIO (CBR) FOR
THE SOAKED SAMPLE USED IN THE
9500

SUBGRADE SHALL NOT BE LESS THAN 25


% AND THE THICKNESS SHALL NOT BE
6625 LESS THAN 30 CENTIMETERS.

6625
1200 1200
SSL = +673.485m SSL = +673.485m
375

4
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23

375
PF5 PF5
2400

2025

2025
A01 PRELIMINARY ISSUE Jo.Na Ra.Ma 16/05/23
Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8

5 Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
3360

with your access to or use of that information or data.


RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


19300 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
19300 ALL SURFACES BETWEEN EXISTING AND NEW Structural, Civil & Construction
Engineering Consultant
FOUNDATION TO BE ROUGHENED AND
DOWEL BARS TO BE POST-INSTALLED TO
ENSURE TRANSFER OF LOADS Robert BirdGroup
OR DEMOLITION/ REMOVAL OF EXISTING Member of the Surbana Jurong Group
FOUNDATION AND REPLACE WITH NEW DUBAI OFFICE
8640

FOUNDATION Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST

6
2700

Project

SOUNDSTORM 2023
7

Title

BIG BEAST STAGE FOUNDATION


PLAN

Date Drawn

FOUNDATION PLAN 02/06/23


Scale at A1
Jo.Na
Designer
SCALE 1 : 100
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:22 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12001 A02


MEMBER
B ....... BEAM
SC ....... STEEL COLUMN

ST
AG
A B C D E F G H J K

E
VB ....... VERT CROSS BRACE

D
C
G

D
C

G
G
G
G
D
C

HB ....... HORIZ. CROSS BRACE

2400 8200 2400 11200 3600 11200 2400 8200 2400


ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

STEEL COLUMN SCHEDULE

MARK SIZE KEY PLAN


a UC152x152x51
c UC152x152x23
d UC203x203x86
e

e
j

j
j
e

SC

SC
SC

SC

SC

SC
SC
SC
e UC203x203x71
1 GENERAL NOTES
f UC203x203x60
g UC203x203x46 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
2400

j UC254x254x89 METERS UNLESS NOTED OTHERWISE.

e
k UC254x254x73

j
j

SC

SC
e

e 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

SC

SC
SC

SC
SC

SC
m UC305x305x137 DIMENSIONS ARE TO BE FOLLOWED.
2 n UC305x305x118
p UC305x305x97 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
q UC356x368x177 OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
r UC152x152x30 M9307-RBG-PS007-ZZ-DR-ST-0003.

4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER


SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.
8900

5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
STEEL FRAMING SCHEDULE ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
MARK SIZE
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
CHS244F UKCHS244.5x10

p
p
FIS_248A FABRICATED BEAM (REFER TO
p

SC
7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

SC

SC

SC
SC
1500
SC

1500 TABLES FOR DIMENSIONS) TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

p
175 FIS_248B FABRICATED BEAM (REFER TO LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
SSL = +673.485m SSL = +673.485m TABLES FOR DIMENSIONS)
SSL = +673.485m FPS100x10 FPS100x10
UB178A UB178x102x19
3 UB254C UB254x146x31
UB356D UB356x171x45
UB457F UB457x191x82

p
p
p

p
SC
SC

UB457N UB457x152x52
SC

SC
UC152A UC152x152x51
UC152B UC152x152x44
UC152C UC152x152x37
UC152D UC152x152x30
UC152E UC152x152x23
9500

UC203D UC203x203x86
p

SC
k

k
SC

UC203E UC203x203x71
SC

SC

p
UC203F UC203x203x60
UC203G UC203x203x52
UC203H UC203x203x46
UC254D UC254x254x89
UC254E UC254x254x73
UC305E UC305x305x137
UC305F UC305x305x118

SC

SC
q

UC305G UC305x305x97
SC

SC

q
4 UC356U UC356x368x177
VB1 70 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT)
2400

VB2 80 DIA BAR OR MACALLOY A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
q

SC

SC
460 M76 (OR EQUIVALENT)
SC

SC

A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

q
5 Rev Revision Description
SCALE 1 2 3 4 5 6
By App
7
Date
8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
12000

Engineering Consultant

Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST
6
2700

Project

7 SOUNDSTORM 2023

Title

BIG BEAST STAGE GROUND FLOOR


PLAN

GROUND FLOOR PLAN


SCALE 1 : 100
Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:24 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12002 A02


MEMBER
B ....... BEAM
SC ....... STEEL COLUMN

ST
AG
E
VB ....... VERT CROSS BRACE

D
C
G

D
C

G
G
G
G
D
C

A B C D E F G H J K HB ....... HORIZ. CROSS BRACE


THE GAPS BETWEEN STRUCTURAL
MEMBERS/SEGMENTS INDICATE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

LOCATION OF CONNECTIONS
(REFER TO DRAWING 2400 8200 2400 11200 3600 11200 2400 8200 2400 STEEL COLUMN SCHEDULE
M9307-RBG-PS007-ZZ-DR-ST-12001)
MARK SIZE KEY PLAN
a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
GENERAL NOTES

c
c
r

j
j
g

SC
SC

g
SC

r
SC
SC

c
j

c
c
f UC203x203x60

c
UC203H UC203H

c
UC203H

g
r
SC UC152D C r

c
SC

SC

SC
SC

SC
SC

SC
SC
UC152D

SC
SC
UC254D

SC
UC203H

SC
UC203H UC203H UC203H UC152E UC203H UC203H UC203H UC203H UC203H

SC

SC

SC

SC
UC152E S
S
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
1 g UC203x203x46
3H

UC254D
METERS UNLESS NOTED OTHERWISE.

SC UC152E

UC152E

UC152E
4D
g UC203H

UC152E

UC152E
j UC254x254x89

UC

UC152D
UC254D
UC152D
UC
UC203H

2D
UC152D

UC254D

UC254D

2D
2D
2D

UC152E

UC152D
UC203H

SC UC203H
20

UC
2D
UC254D

2D
UC

2E
25

3H
UC

UC
2D

UC
4D
UC
2D

15

2D

15
UC

15
k UC254x254x73

UC

15
15

15
UC152E

15
15
15
2400

15
UC

15

20
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

15

15

25
15
2D

15
2D
UC
15
15
UC

15

UC

UC
UC
UC

UC

UC
UC

15
2D
UC
UC

UC
2D
m UC305x305x137

UC
2D
DIMENSIONS ARE TO BE FOLLOWED.

2D
UC
UC

2D
r UC

2D
20

UC

25
15

20
2D
n UC305x305x118

25
3H

4D
2E
c

3H

g
UC152E UC254D
SC

UC203H UC203H

4D
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
2 UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H
p UC305x305x97

UC
H

OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

S C 4D
r

r
UC203H g

c
c

c
j

S r
g UC203H C g
q UC356x368x177

c
c
3

r
r
c

j
SC UC305G SC S UC254D
SC
SC

SC

j
j

UC254D
SC
SC

SC

SC
SC UC254D
SC

25
20

SC
SC

25

SC
SC
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

SC
SC

SC

SC
j UC254D SC

SC UC203H
SC
SC UC203H

r UC152x152x30

4D
UC

UC
M9307-RBG-PS007-ZZ-DR-ST-0003.

UC203H
UC203H

3H
UC
4D

UC
UC

20
g

25

20
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

25
20
SC

UC
j Cj
UC

3H
4D
3H

SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

a g
UC254D
SC g

UC254D UC203H PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE


c

c
j
c

c
UC203H UC203H

SC
SC
SC
UC203H FULLY WELDED AT CONNECTION POINTS.

j
SC
UC203H UC152A

c SC

SC
UC152A

SC
SC

SC
a

UC254D
SC

c
UC254D 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
SC

c UC305G
STEEL FRAMING SCHEDULE

SC

UC305G SC UC305G

UC203E C a
SC
UC305G j

UC203H
SC UC203E

A
SC
UC203E

UC203E
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
8900

UC

UC
UC203H

2
S
E

15
3
15

20
20
MARK SIZE

UC
2A

3E
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

UC
CHS244F UKCHS244.5x10

SC j

c
j
a

c
c

UC152A UC203H UC254D FIS_248A FABRICATED BEAM (REFER TO


SC

SC
SC
UC203H UC254D UC203H UC203H 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

a
SC

SC

UC152A

UC203E SC
TABLES FOR DIMENSIONS) TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
a
SC

UC203E a
c
FIS_248B FABRICATED BEAM (REFER TO LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
SC

SC UC305G
A

SC
SC
SC UC203E

UC203H

UC305G

UC203H
2

TABLES FOR DIMENSIONS)

UC
15

UC305G
UC203E

15
UC

FPS100x10 FPS100x10
UC

2A
3
20
UB178A UB178x102x19

20
3E

j
a

c
UC

a
c
j

UB254C UB254x146x31

j
SC

SC
UC152A UC203H UC203H UC203H UC152A
SC

SC

SC

SC
SC
3 UC203H UC254D
UB356D UB356x171x45
a

j
c

SC
SC

c
UB457F UB457x191x82
SC

UC203H

SC

2A
UC305G

UC203E

UC203E
3E

UB457N UB457x152x52
UC

UC305G
c UC305G
UC203H
UC203E

UC203E

UC305G

15
UC
20
15

UC
UC152A UC152x152x51

20
UC
2A

3E
UC152B UC152x152x44
UC152C UC152x152x37

c
UC152A

SC
a

c
UC203H UC203H
c

UC152D UC152x152x30
SC

UC203H UC203H UC254D UC152A

SC
SC

UC254D
SC

SC
SC

a UC203E C a
UC152E UC152x152x23

S
UC305G j
UC203E a

UC305G
SC

c
UC203E a
j
SC

UC203D UC203x203x86

SC
UC203H
E
SC

SC
SC UC305G
A

3
UC203H
SC UC203E

UC
2

UC

20
UC203E UC203x203x71
15

UC305G
9500

15
UC
20
UC

UC203F UC203x203x60

2A
3E

UC203G UC203x203x52
j

a
c

c
j
c

n j
c

SC
a

UC254D UC203H UC203H

SC
SC

SC

SC

SC
UC152A UC203H UC254D UC152A
SC

UC203H UC203x203x46
SC

UC203H
UC305F UC254D UC254x254x89
a

j
UC356U UC356U

q
UC305F

SC

C a
SC

SC C c

SC

SC UC356U SC UC254D SC
SC
UC254E UC254x254x73
UC203H

C
S

SC UC152A S
D

k UC254D q
2A
n

2A

4D
q

c UC152A n

UC203H
4

UC305E UC305x305x137
SC UC305F
SC

SC
25
UC254D

q UC254D

15

15
k UC305F

25
UC

UC

UC
UC305F UC305x305x118

UC
UC

UC
UC
UC305G UC305x305x97
UC

15

25
15
25

q
c

c
c

c
c

c
c
UC356U UC356x368x177
n

n
k

2A

4D
SC

SC
SC

SC

SC
SC

SC
SC

SC
n

2A

k
c
k

SC
4D

UC203H UC203H

q
SC
SC

SC
SC

UC254E UC254E UC254E UC356U


SC

SC
SC

UC356U UC305F UC305F UC305F

SC

SC
VB1 70 DIA BAR OR MACALLOY
SC

UC254E UC254E UC254E UC254E UC305F


4 460 M76 (OR EQUIVALENT)
2A
q

2E

UC
UC UC254D
UC305F
UC254D

UC305F

4E
SC

VB2 80 DIA BAR OR MACALLOY

4E
2E
4E

UCUC305F
2E

2E
UC152E
4E

2E
15
SC UC254E

2E

UC
15

UC
UC

A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


UC305F

SC UC254E
UC
UC

UC152E
SC UC152E
UC254D

UC

UC

25
2E
UC254E

UC254E

SC UC152E
UC

UC
UC
UC152E

c UC152E

UC152E

25
25
15
25

UC

15

UC152E
460 M76 (OR EQUIVALENT)

15
UC
15
25

UC152E

UC254E

UC254E
2400

15

25
15
15

4D
15

15
25

A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23


15

15

UC
4D

25

25

UC
UC

UC
UC

15
UC

2A

4D
UC

UC
UC
UC

UC
UC

4E
2E

2E

UC

2E
4E

2E

2E

15
25

4E

4E
15
15

2E

25
Rev Revision Description By App Date

UC
25

2A
UC

k
k

2A

k
UC356U

q
c
4D

15
SCALE 1 2 3 4 5 6 7 8
UC305F UC305F

c
UC356U

SC
5

2E
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
UC254E UC254E accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
e

UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E


n

n
UC305F

SC c
c

SC k
SC

SC
e UC254D C e
q

You are responsible for verifying that any information or data supplied or transferred by electronic means
UC203H k

q
c
SC

SC
SC

e
SC
SC k

SC

SC

SC
SC n
SC

SC
SC
SC

SC

g
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
UC254D n

SC

C
SC
UC203H

UC203H
UC203E UC203E

SC
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
UC203H

r UC203H

SC UC203E S

UC203H
UC203H

UC203E e
UC203H

UC203H
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UC203H
g

5G
damage however caused which you or any other party may directly or indirectly suffer in connection

UC
SC

with your access to or use of that information or data.


3E

30
UC

20
20

RBG provides this information for the express purpose contemplated by the underlying

UC
3E
30

terms of engagement for the project which must not be used for any other purpose. The
UC

information is not a contractual document. Unless otherwise agreed in writing by RBG,


5G

SC r
r

SC e
r
all intellectual property rights in any information supplied by RBG are owned by, or
r

r
r
SC

r
r

SC
SC
r
SC

UC254D
r
UC254D
SC
SC

UC254D UC254D UC203E UC254D UC254D UC254D UC254D UC254D UC254D UC203E UC254D licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable

SC
SC
SC
SC

SC

SC

SC

g
licence to use the intellectual property rights for the express purpose.

SC
DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC203H

UC203H

UC203H

r
UC254D e

SC r
UC203H

UC203H
SC UC254D

UC203E e

UC203H

SC
SC

SC
UC203H

UC203H

SC UC203E
3E
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE

5G
UC

20
UC

Structural, Civil & Construction

UC

30
20

Engineering Consultant
30

3E

UC
5G

e
e

r
SC r
r
r

Robert BirdGroup
r

UC254D
12000

r
r

SC
SC
UC254D UC254D UC203E
SC
SC

UC254D UC254D UC254D


SC

UC254D UC254D UC254D UC254D UC203E UC254D


SC

SC
SC

SC

g
SC
UC203H
r
UC203H

UC203H

SC r
SC g

UC203E e
UC203H

Member of the Surbana Jurong Group


r
r

e UC254D

UC203H

UC203H

UC203H

UC203H

SC
SC
UC254D e
SC

SC

SC UC203E

5G
SC

3E
r

SC

UC
ROOF CLADDING: KALZIP OR SIMILAR,
20

DUBAI OFFICE

30
UC

20
SPANNING BETWEEN ALL TRUSSES
UC

UC
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866

3E
30

Ibn Battuta Gate Email: MENA@robertbird.com.au


5G

Level 4, Office Suite 415 Web: www.robertbird.com

e
SC r

SC e
r

r
r
r
r

r
r
r
r

SC
SC
SC
SC

Jebel Ali, Dubai


SC

SC
UC254D UC203E UC254D UC254D UC254D UC254D UC254D
SC
SC

UC254D UC254D
SC

UC203E UC254D

g
SC
SC

PO Box 118570

SC
Dubai, United Arab Emirates TRADE LICENCE 597197
UC254E UC254E
g

SC SC e r

k
r
SC

SC
SC

SC

UC203H

g UC203H

UC203H

k UC254D C
UC203H

Client
UC203H
UC203H

S
k
k
UC254D
SC UC254D

5G
SC
SC

MDLBEAST

4E
k

UC254E
UC

30
UC

25
25

UC
UC
30

4E
5G

g
k

g
g

SC
k

g
g

UC254D
SC

SC
SC

UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E


SC
SC

SC

SC

SC

SC
SC

g
6

SC
UC254D
g

4E

3H
UC254D
SC

UC254D

4E
3H

5G
25

UC254D
UC254E
3H

3H
3H

20

UC
3H
3H

UC203H

UC203H

UC
UC
UC

25
UC203H
UC

UC
UC

UC

UC203H

30
20

UC
UC203H

UC203H

UC203H

20
20

20
2700

20
20

20

UC
UC203H

UC203H

UC203H
20

Project
20
30

20

20

g UC
20

UC

UC
UC
UC

UC
UC

3H
UC

3
5G

3H

SOUNDSTORM 2023
3

3H

H
3H

UC
25

UC

25
4E

SC
20
g

4E
7
SC

3H

UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254E


UC254D
g

g
g
g

g
k

k
g
g
k

SC

SC

SC

SC

SC

k
SC
SC

SC
SC

SC
SC
SC
SC

SC
Title

BIG BEAST STAGE LOWER ROOF


BOTTOM CHORD STEEL FRAMING
PLAN

LOWER ROOF BOTTOM CHORD STEEL FRAMING PLAN Date Drawn


SCALE 1 : 100
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:29 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12003 A02


MEMBER
B ....... BEAM
SC ....... STEEL COLUMN

ST
AG
E
VB ....... VERT CROSS BRACE

D
C
G

D
C

G
G
G
G
D
C

HB ....... HORIZ. CROSS BRACE

A B C D E F G H J K
ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

STEEL COLUMN SCHEDULE

MARK SIZE KEY PLAN


2400 8200 2400 11200 3600 11200 2400 8200 2400 a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
GENERAL NOTES
f UC203x203x60
g UC203x203x46 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
j UC254x254x89 METERS UNLESS NOTED OTHERWISE.
UC203H UC203H UC203H UC254D UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC254D UC203H UC203H UC203H
1 k UC254x254x73
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

UC203H
m UC305x305x137
UC203H

UC203H
UC152D
DIMENSIONS ARE TO BE FOLLOWED.

2D

2D
UC

2D

UC254D

UC254D

UC152D

UC152D
UC203H
2D
UC152D
UC

UC

UC
2D

UC
UC
2D

UC

UC

2D
UC
2D

2D
UC254D

UC152E

UC152E

UC152E
UC152E

UC152E
UC

UC152D
2D
UC152D
UC254D

UC152E

UC152E

UC152E

UC152E

UC152E
2400

n UC305x305x118

15

15

15
15

15
15

15
15
15

15
15
15

15

15
UC

15

15

15
15
15

2E

15

3H
UC
UC
4D
UC

4D
3H

UC
UC

UC

UC

UC
2D
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

2D

2D
2D

UC

2D
15
2D
UC

2D
15

2D

UC
UC

UC
p UC305x305x97

2D
2D

UC

20

20
25

25
20

25
20

25

UC

2E
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

UC

3H
UC

4D
3H

UC
UC

q UC356x368x177

4D
UC254D UC254D UC203H SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
2 UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H
r UC152x152x30 M9307-RBG-PS007-ZZ-DR-ST-0003.

UC254D
UC203H

UC203H

UC203H

UC203H
UC254D
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

UC203H
UC254D
UC254D
UC203H
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

UC
UC

3H
4D

4D
H

UC
UC
3

PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE

25
STEEL FRAMING SCHEDULE

20
25

25
20
20

20
25

4D

UC
UC

UC
UC

3H

FULLY WELDED AT CONNECTION POINTS.

3H
4D
UC203H UC254D UC254D UC203H MARK SIZE
UC203H UC203H UC203H UC203H CHS244F UKCHS244.5x10
5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
UC152A UC254D UC254D UC152A FIS_248A FABRICATED BEAM (REFER TO

UC203H

UC203E
TABLES FOR DIMENSIONS)

UC305G
UC203E

6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES


UC203E

UC203H

UC305G
8900

UC305G

UC

E
UC305G
A

UC203E
3
FIS_248B FABRICATED BEAM (REFER TO

UC
2

20
20
15

15
TABLES FOR DIMENSIONS) 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

UC
3E
UC

2A
FPS100x10 FPS100x10 TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
UC203H UC203H UC254D UC203H UC203H UC152A LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC254D UB178A UB178x102x19
UC152A UB254C UB254x146x31

UC305G

A
UB356D UB356x171x45

UC203H

UC203E

UC203E
UC203H
UC203E

UC203E

UC305G

UC305G

2
3

UC

15
UC

20

UC305G
UB457F UB457x191x82

UC
UC

20
15

UB457N UB457x152x52

3E
2A

UC152A UC152x152x51
UC203H UC203H UC254D UC254D UC203H UC203H UC152A
UC152B UC152x152x44
3 UC152A UC152C UC152x152x37
UC152D UC152x152x30

UC305G
UC305G

UC
2A

UC

UC203H

UC203E

UC203E
UC305G

UC305G
UC203H
UC203E

UC203E

3E
UC152E UC152x152x23

15
15

20

20
UC203D UC203x203x86

2A
UC

3E

UC
UC203E UC203x203x71
UC203H UC203H UC152A UC203F UC203x203x60
UC203H UC203H UC254D UC254D UC203G UC203x203x52
UC152A UC203H UC203x203x46
UC203E

UC305G

A
UC203E

UC203H

UC203E
E
UC203H

UC254D UC254x254x89
UC305G

2
3

UC305G

UC
UC

UC305G

15
UC203E
20
9500

UC254E UC254x254x73

UC
20
15

UC

3E
2A

UC305E UC305x305x137
UC203H UC203H UC203H UC152A UC305F UC305x305x118
UC152A UC203H UC254D UC254D
UC305G UC305x305x97
THE GAPS BETWEEN STRUCTURAL UC356U UC356x368x177
UC356U UC305F MEMBERS/SEGMENTS INDICATE UC305F UC356U VB1 70 DIA BAR OR MACALLOY
UC203H
UC356U

UC305F

UC305F

UC203H
UC305F

UC356U

UC356U
LOCATION OF CONNECTIONS 460 M76 (OR EQUIVALENT)
UC305F
UC356U

(REFER TO DRAWING VB2 80 DIA BAR OR MACALLOY

4D
2A
UC

2A
4D

UC

UC
M9307-RBG-PS007-ZZ-DR-ST-12001)

UC
460 M76 (OR EQUIVALENT)

25
15
25

15
25

15

25
15

UC
UC
4D

UC
UC

2A

4D
UC305F UC305F

2A
UC356U UC305F UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC305F UC356U A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
4 UC305F A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

UC152E
UC152E
UC305F
UC254E

UC152E

UC152E

UC152E

UC152E

UC152E
UC305F
4E

UC356U

UC356U
UC305F
UC152E
UC152E

UC254E

4E
UC
UC
UC254E
UC356U

UC254E
UC

UC

UC305F
UC152E

4E
Rev Revision Description By App Date

UC
25
UC356U

25
2E
2400

UC
2E
4E

2E

2E
UC

2E

25
25

2E
15

25
15

UC
UC SCALE 1 2 3 4 5 6 7 8

2A

4D
UC

UC

UC
4D

UC
2A

2E
UC

UC

15

UC
15

UC
15

15
25

25
15
15

15

4E
4E

2E

2E

UC
25

15
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the

15
15

15

25
15

15
25

15

15
25

2E
15

25
UC
UC

UC
UC

UC

4E
UC

accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

UC
4E

UC
2E
UC

UC
UC

2A

2E
UC

2E

2A
4D

4D
2E
You are responsible for verifying that any information or data supplied or transferred by electronic means
UC356U UC305F UC305F UC305F UC305F UC356U
5 UC254E UC254E UC254E
NOTES: matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
UC305F UC305F UC254E UC254E UC254E UC254E or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
*FPS100x10 TO BE TACK WELDED damage however caused which you or any other party may directly or indirectly suffer in connection
UC203E UC203E ON THE BOTTOM FLANGE OF
with your access to or use of that information or data.
UC203H

UC203H

RBG provides this information for the express purpose contemplated by the underlying
UC254D

UC203H
UC254D

UC203H

UC203H

UC203H

UC254D
UC254D
THE MAIN BEAMS

UC203H
UC203H

UC203H

UC203H
terms of engagement for the project which must not be used for any other purpose. The

3E
information is not a contractual document. Unless otherwise agreed in writing by RBG,
UC

20
all intellectual property rights in any information supplied by RBG are owned by, or

5G
UC

20

UC
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable

30
licence to use the intellectual property rights for the express purpose.
30

3E

UC
5G

UC254D UC254D UC254D UC254D UC254D UC203E UC254D UC254D DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC254D UC254D UC254D UC254D REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC203E
Structural, Civil & Construction
UC203H

UC203H

UC203H

UC203H

UC203H

UC254D
UC203H

UC203H
Engineering Consultant
UC254D

UC254D

UC203H
3E

UC254D
20

5G
UC

UC
ROOF CLADDING: KALZIP OR SIMILAR,
Robert BirdGroup
UC

30
20
30

SPANNING BETWEEN ALL TRUSSES

UC
3E
5G

UC254D
12000

UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC203E UC254D UC254D Member of the Surbana Jurong Group
UC203E DUBAI OFFICE
UC254D
UC203H

UC254D

UC254D
UC203H

Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
UC203H

UC203H

UC203H

UC203H
UC203H
UC254D

Ibn Battuta Gate Email: MENA@robertbird.com.au


UC

UC203H
UC

5G
Level 4, Office Suite 415 Web: www.robertbird.com
20

3E
30

Jebel Ali, Dubai

30
20
3E

PO Box 118570
5G

UC
UC
Dubai, United Arab Emirates TRADE LICENCE 597197

UC254D UC203E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC203E UC254D
Client

MDLBEAST
UC203H

UC254E
UC203H

UC254E
UC203H

UC203H

UC203H
UC254D

UC254D
UC203H
UC

UC254D

UC254D
4E

UC
30

5G
25

25
5G

30
UC

4E

UC
UC254D UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E UC254D
6 Project
UC203H

UC203H

UC254D
UC203H

UC203H
UC203H
UC254D

UC203H

UC203H
UC

3H

3H

3H

UC203H

5G
UC203H
UC254D
UC203H

SOUNDSTORM 2023
3H
UC254D

UC
UC

3H
3H
30

UC
20
2700

UC

20

30
20

UC
UC
20

20
20
UC

3H

4E
4E

UC
5G

UC

20

20
UC

UC
UC

UC

20
20

UC

20
20
3H
3

25
25

25

20

25
H

UC
20

UC
3H
3H

3H
3

UC
UC

4E

UC

4E
H
3H

UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E


7
Title

BIG BEAST STAGE LOWER ROOF


TOP CHORD STEEL FRAMING PLAN

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
LOWER ROOF TOP CHORD STEEL FRAMING PLAN Approved
Ra.Ma
SCALE 1 : 100

02/06/2023 6:21:33 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12004 A02


MEMBER
B ....... BEAM
SC ....... STEEL COLUMN

ST
AG
E
VB ....... VERT CROSS BRACE

D
C
G

D
C

G
G
G
G
D
C

HB ....... HORIZ. CROSS BRACE


A B C D E F G H J K
ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

STEEL COLUMN SCHEDULE


2400 8200 2400 11200 3600 11200 2400 8200 2400
MARK SIZE KEY PLAN
a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
GENERAL NOTES
f UC203x203x60

c
c

UC152E SC c

c
c

c
UC203H UC203F

SC

SC

SC
UC203F UC203H UC203H UC203H UC203H UC203H UC203H

SC

SC

SC
SC

SC

SC
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
1 g UC203x203x46
METERS UNLESS NOTED OTHERWISE.

3F
2E
UC152E
UC

UC152E
j UC254x254x89

UC152E

UC152E

UC203F
UC152E

UC

UC152E
UC203F

UC152E
UC

20
UC
15
UC

UC
UC203F

UC203F
UC152E
UC
20

2E
k UC254x254x73

2E
2E

UC
15

UC
2E

15
2400

3F

15
15

2E
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

15
2E
15
15

15
15
2E
15
3F

2E
2E
m UC305x305x137

2E

15

2E
15
2E
DIMENSIONS ARE TO BE FOLLOWED.

UC

UC
UC
20

UC
UC

UC
UC
UC
n UC305x305x118

UC

15

20
UC203F UC203H UC203H UC203H 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

2E
2 p UC305x305x97

3F
UC203H UC203H UC203H UC203H UC203F OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

UC
f

UC203F f
q UC356x368x177

c
c
c

c
c
SC

UC203H C c
SC

UC203F

UC203F
UC203H c

SC
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

SC
SC

SC

SC

F
UC
SC
SC
20

SC
SC

3
r UC152x152x30

20
M9307-RBG-PS007-ZZ-DR-ST-0003.

UC203F

20
3F

UC203H
UC203H

UC
UC203H
UC203H

3F
3F
20
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

f
UC
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

SC C f

SC

f
UC203F

SC
UC203F

S
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE

SC k

r
r

r
r

r
STEEL FRAMING SCHEDULE

r
UC254D UC254D UC254D UC254D FULLY WELDED AT CONNECTION POINTS.

SC
SC
UC254E UC254D UC254D

k
SC

SC
SC

SC

SC
f
UC254D

SC SC

SC
UC254E THE GAPS BETWEEN STRUCTURAL MARK SIZE

SC r
UC203H

UC203H

UC203H

UC203H

UC203H
5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

SC
UC
MEMBERS/SEGMENTS INDICATE

SC UC254E

UC254E
SC

UC254E k
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
8900

CHS244F UKCHS244.5x10

UC254E

E
UC203H
25
LOCATION OF CONNECTIONS

4
25
4E
(REFER TO DRAWING FIS_248A FABRICATED BEAM (REFER TO

UC
TABLES FOR DIMENSIONS) 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
M9307-RBG-PS007-ZZ-DR-ST-12001)

SC r

k
SC k
FIS_248B FABRICATED BEAM (REFER TO

r
r

r
SC
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

SC

SC
SC
SC

SC

SC
TABLES FOR DIMENSIONS)
TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
FPS100x10 FPS100x10 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).

r
k

SC r
UC254E

UC254E
SC
UC203H

UC203H

UC203H

UC203H

k
SC

SC
UC203H
UB178A UB178x102x19

4E

UC203H

UC
SC UC254E
UC254E

25
UB254C UB254x146x31

25
UC
UB356D UB356x171x45

4E
SC k
UB457F UB457x191x82

r
SC

k
r
r
r

k
SC

SC

r
3

SC

SC
SC
SC

SC

SC
UB457N UB457x152x52

SC
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E UC152A UC152x152x51

UC254E

UC254E
r
k

SC
UC152B UC152x152x44
SC

UC254E

4E
UC203H

UC203H

UC203H

UC203H

UC203H
UC

25
UC152C UC152x152x37

UC203H
UC254E

25

UC
ROOF CLADDING: KALZIP OR SIMILAR, UC152D UC152x152x30
4E

SPANNING BETWEEN ALL TRUSSES


UC152E UC152x152x23
k

SC r

k
r
r

r
UC203D UC203x203x86

SC
SC

UC254D UC254D UC254D UC254D UC254D UC254D

SC
SC
SC

SC

SC

SC
UC254D UC254E
SC

UC203E UC203x203x71
UC254E
k

UC203H

UC203H

r
UC203F UC203x203x60

r
UC203H

UC203H

SC
SC

UC254E
UC203H

UC203H
SC

k
E

UC254E
UC203G UC203x203x52

SC
4

UC
UC254E
9500

25

UC203H UC203x203x46

25
UC

4E
UC254D UC254x254x89
r
k

k
SC

UC254E UC254D UC254D UC254D UC254D UC254D UC254E UC254x254x73


SC

SC

SC

SC

SC

SC

SC
UC254D UC254D UC254E

SC
UC305E UC305x305x137

m
UC305E UC305E
k

r
m

SC SC r
SC

m k

UC305E SC
SC UC305F UC305x305x118

SC
SC
UC203H

UC203H

UC203H

UC203H
C
SC UC305E S
E

E
UC203H
UC305G UC305x305x97
UC305E m

UC203H
5

5
30

30
UC305E
SC

UC356U UC356x368x177
UC

UC
VB1 70 DIA BAR OR MACALLOY
UC

UC
460 M76 (OR EQUIVALENT)
30

30
m

m
SC

5E

5E
r

m
r

r
r

r
VB2 80 DIA BAR OR MACALLOY

SCr

r
r
UC356U UC305F UC152E UC305F UC305F UC305F UC356U

SC

SC

SC

SC
SC

SC

SC

UC305E UC305F UC305F

SC

C
SC
m

SC
4

UC152D S
460 M76 (OR EQUIVALENT)

UC203D
5E
UC203D

2D
5E

2D

C
UC305E

2D
UC

2D

30
2D

2D

UC305E
2D
UC305E

UC
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23

UC152D
UC152D

UC
UC

UC305E
UC

C
30

152
C

UC

UC152D
15
UC152D

UC
15
UC

UC152D
UC152D

UC152D

152
UC
UC152D

15
UC

UC152D
152

15
2400

15

15
UC

15
152

15
15
UC
15

152
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
15

UC

15
15
UC

UC

UC
UC

UC

UC
UC
152

2D
2D
2D

UC
2D
UC

2D
2D
30
C

UC
Rev Revision Description By App Date

UC

C
5E
C

30
15
SCALE 1 2 3 4 5 6 7 8

5E
2D
5 UC356U UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E UC356U
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means

r
m

r
r

r
NOTES:
m

m
r
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be

SC

SC

SC
r
SC

SC

SC

SC

SC
SC

SC
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
SC
SC

SC

SC
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
*FPS100x10 TO BE TACK WELDED damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
ON THE BOTTOM FLANGE OF RBG provides this information for the express purpose contemplated by the underlying
THE MAIN BEAMS terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,

CHS244F

CHS244F
all intellectual property rights in any information supplied by RBG are owned by, or
CHS244F

CHS244F

licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

Robert BirdGroup
12000

Member of the Surbana Jurong Group


DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST

6
2700

Project

SOUNDSTORM 2023
7

Title

BIG BEAST STAGE UPPER ROOF


BOTTOM CHORD STEEL FRAMING
PLAN

UPPER ROOF BOTTOM CHORD STEEL FRAMING PLAN Date Drawn

SCALE 1 : 100 02/06/23 Jo.Na


Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:36 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12005 A02


MEMBER
B ....... BEAM
SC ....... STEEL COLUMN

ST
AG
E
VB ....... VERT CROSS BRACE

D
C
G

D
C

G
G
G
G
A B C D E F G H J K
D
C

HB ....... HORIZ. CROSS BRACE


ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

STEEL COLUMN SCHEDULE

MARK SIZE KEY PLAN


a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
UC203H UC203F GENERAL NOTES
UC203F UC203H UC203H UC203H UC203H UC203H UC203H f UC203x203x60
1 g UC203x203x46 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN

3F

3F
2E

UC203F
2E
2E

2E
UC203F

2E
2E
20

20
UC152E
METERS UNLESS NOTED OTHERWISE.

15
2E
UC203F

UC152E

UC

UC
j UC254x254x89

UC

UC203F
UC152E
UC

UC

15
UC
15

15
UC

UC
15
15

UC

UC152E
15

UC152E
UC152E

UC152E

UC152E

UC152E

UC152E
15

15
15
k UC254x254x73

UC
15

UC

UC
15

UC
UC

15
UC
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

2E

2E
2E
2E

2E

UC

UC
2E
UC
m UC305x305x137 DIMENSIONS ARE TO BE FOLLOWED.

15

20
20
n UC305x305x118

2E

3F
2

3F
UC203F UC203H UC203H UC203H UC203H UC203H UC203H UC203H p UC305x305x97 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

F3
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

UC203F
20
UC203F

UC203F
q UC356x368x177

UC203F
UC203H

UC203H

UC203H

UC203H

UC203H
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

UC203H

UC
r UC152x152x30 M9307-RBG-PS007-ZZ-DR-ST-0003.

UC

UC
3F
20

20

20
UC

3F

3F
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
UC203F UC203F SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
UC254D UC254D UC254D UC254D UC254D UC254D UC254D STEEL FRAMING SCHEDULE PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.
UC254E UC254E MARK SIZE

UC203H

UC203H

UC203H

UC203H

UC203H

UC203H
UC254E

UC254E

UC254E
CHS244F UKCHS244.5x10 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

UC254E
E

UC
4
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

25
FIS_248A FABRICATED BEAM (REFER TO

25
UC
TABLES FOR DIMENSIONS)

4E
FIS_248B FABRICATED BEAM (REFER TO
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E TABLES FOR DIMENSIONS)
7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
FPS100x10 FPS100x10 TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

UC203H

UC203H

UC203H

UC203H

UC254E
UB178A UB178x102x19

4E
UC254E
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).

UC203H

UC203H
UC254E

UC254E
UC

25
UB254C UB254x146x31

25

UC
4E
UB356D UB356x171x45
UB457F UB457x191x82
3 UB457N
UC152A
UB457x152x52
UC152x152x51
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E
UC152B UC152x152x44

UC203H

UC203H

UC203H

UC203H

UC203H

UC203H

UC254E

UC254E
UC254E
UC254E

UC
4E

UC152C UC152x152x37

25
25

UC152D UC152x152x30

4E
UC

ROOF CLADDING: KALZIP OR SIMILAR, UC152E UC152x152x23


SPANNING BETWEEN ALL TRUSSES
UC203D UC203x203x86
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254E UC203E UC203x203x71
UC254D UC203F UC203x203x60

UC203H

UC203H

UC203H

UC203H

UC203H

UC203H
UC254E

UC254E

UC254E
UC203G UC203x203x52

E
UC254E
UC

4
25
UC203H UC203x203x46
25

UC
4E

UC254D UC254x254x89

E5
UC254E UC254x254x73

30
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E

UC
UC305E UC305x305x137
UC305E UC305F UC305x305x118
UC305E

UC203H

UC203H
E

UC203H

UC203H

UC203H
UC305G UC305x305x97

UC203H
5

UC305E

UC305E
30

UC305E
UC305E

UC356U UC356x368x177
UC

VB1 70 DIA BAR OR MACALLOY

E
UC

UC
5
460 M76 (OR EQUIVALENT)

30
30

30
UC
5E

5E
VB2 80 DIA BAR OR MACALLOY
UC356U UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E UC356U 460 M76 (OR EQUIVALENT)
4
UC

UC152D

5E
UC152D

UC152D
UC152D

UC152D

UC152D

UC305E
UC152D

UC305E
UC152D
UC305E

UC305E
30

UC

UC
UC152D

UC152D
UC

UC

UC

30
2D
UC

2D
2D

2D
2D
2D

2D
5E

UC
15
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
15

15
15

15

15
15

15
15

15
15
15

15
UC
2D

UC

2D
2D

2D

2D
2D

UC
UC

A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

UC
UC
UC

UC

UC
5E

15
30

Rev Revision Description By App Date

2D

30
UC356U UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC356U
UC

5E
SCALE 1 2 3 4 5 6 7 8

UC305E UC305E Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means

NOTES: matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
*FPS100x10 TO BE TACK WELDED damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
ON THE BOTTOM FLANGE OF RBG provides this information for the express purpose contemplated by the underlying
THE MAIN BEAMS terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST

Project

SOUNDSTORM 2023
7

Title

BIG BEAST STAGE UPPER ROOF TOP


CHORD STEEL FRAMING PLAN

UPPER ROOF TOP CHORD STEEL FRAMING PLAN


SCALE 1 : 100 Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:39 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12006 A02


NOTES:
STIFFENER TO HAVE THE SAME STIFFENER TO HAVE THE SAME

ST
AG
UNLESS NOTED OTHERWISE ALL TRUSS AND TOWER COLUMN

E
THICKNESS AS THE BEAM'S FLANGE THICKNESS AS THE BEAM'S FLANGE

D
C
G

D
C

G
G
G
G
D
C

CONNECTIONS TO BE STIFFENED UP WITH 2NO. STIFFENERS (ON


EACH SIDE) OF THICKNESS SIMILAR TO THE FLANGE THICKNESS
B1 OF THE LARGEST MEMBER CONNECTED TO IT. 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

- BEAM CONNECTIONS
TRUSS SEGMENT A TRUSS SEGMENT B CONNEC PLATE - PL1 (mm) PLATE - PL2 (mm) PLATE - PL3 (mm) PLATE - PL4 (mm) PLATE - PL5 (mm) HOLE PLATE PIN/BOLT
KEY PLAN
TION NO. DIA fy fu ADDITIONAL NOTES
a b Thk c d Thk c d Thk a b Thk e f Thk DIA(mm) GRADE
TYPE (mm) (N/mm²) (N/mm²)
TYPE-A 76 240 240 40 210 230 60 210 230 25 240 240 30 - - - 50 S355 49 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-B 108 290 290 50 270 290 90 270 295 50 290 290 35 - - - 77 S355 76 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-C 32 340 340 50 310 335 75 310 335 40 340 340 35 - - - 86 S355 85 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-D 32 290 290 50 310 310 100 250 305 40 340 340 40 - - - 81 S355 80 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-E 24 340 270 55 310 365 85 370 370 45 410 410 50 - - - 101 S355 100 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-F 44 250 250 30 250 260 50 210 255 25 290 290 30 - - - 46 S355 45 - - PL1 & PL4 TO BE Z35 GRADE
TYPE-G 36 180 180 30 210 210 35 160 210 20 230 230 30 - - - 37 S355 36 900 1000 PL1 & PL4 TO BE Z35 GRADE
TYPE-H 368 - - - - - - - - - - - - 150 150 8 22 S355 20 640 800 PL1 & PL4 TO BE Z35 GRADE
* NOTE: ALL HOLES, PLATES ANS PINS TO BE MACHINED FOR A TIGHT FIT.

COLUMN CONNECTIONS
PLATE - PL1 (mm) PLATE - PL2 (mm) PLATE - PL3 (mm) PLATE - PL4 (mm) Hole Grade Pin/Bolt
CONNECTION TYPE NO. DIA DIA fy fu ADDITIONAL NOTES
a b Thk c d Thk c d Thk a b Thk Grade
(mm) (mm) (N/mm²) (N/mm²)
TYPE-1 48 300 300 50 250 280 60 250 280 30 300 300 40 73 S355 70 900 1000 PL1 & PL4 TO BE Z35 GRADE
TYPICAL CONNECTION OF TRUSS SEGMENTS TYPE-2 16 330 230 50 300 330 90 320 335 45 360 360 45 91 S355 90 900 1000 PL1 & PL4 TO BE Z35 GRADE
SCALE 1 : 10 TYPE-3 48 400 430 60 350 375 105 350 375 55 400 430 50 101 S355 100 900 1000 PL1 & PL4 TO BE Z35 GRADE
HOLES, PLATES & PINS TO BE TYPE-4 8 200 200 40 160 205 50 210 230 25 230 230 30 37 S355 36 900 1000 PL1 & PL4 TO BE Z35 GRADE
MACHINED FOR A TIGHT FIT TYPE-5 (BASEPLATE) 24 400 430 45 350 375 80 350 375 45 TBC TBC TBC 101 S355 100 900 1000 PL1 & PL4 TO BE Z35 GRADE
* NOTE: ALL HOLES, PLATES ANS PINS TO BE MACHINED FOR A TIGHT FIT.
PL3
TRUSS SEGMENT A TRUSS SEGMENT B

PL1 PL2 PL3 PL4

B1 AN ALTERNATIVE CONNECTION DESIGN (OPTION B)


SECTION - IS PROVIDED IN DRAWING 12008
SCALE 1:10

(PL5) HOLE DIA


MEMBER - B c/2

MEMBER - A
40 60 40

d
b

A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


A01 PRELIMINARY ISSUE Jo.Na Ra.Ma 16/05/23
Rev Revision Description By App Date
a c/2 SCALE 1 2 3 4 5 6 7 8
50 60 40 Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
c You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or

TYPE-H BEAM CONNECTION PLATE - PL1 & PL4 DETAILS PLATE - PL2 & PL3 DETAILS damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
SCALE 1 : 10 RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

C1
STIFFENER TO HAVE THE SAME
Robert BirdGroup
- Member of the Surbana Jurong Group
THICKNESS AS THE BEAM'S FLANGE E1 DUBAI OFFICE
- Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
TOWER COLUMN

TOWER COLUMN

Jebel Ali, Dubai


PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
SEGMENT B

SEGMENT B

Client
TOWER COLUMN

TOWER COLUMN
MDLBEAST
SEGMENT A

SEGMENT A
HOLES, PLATES & PINS TO BE PL1 STIFFENER TO HAVE THE SAME
MACHINED FOR A TIGHT FIT THICKNESS AS THE BEAM'S FLANGE
PL2

Project

PL3 PL3 SOUNDSTORM 2023


PL4 HOLES, PLATES & PINS TO BE PL1
MACHINED FOR A TIGHT FIT PL2
TOWER COLUMN

TOWER COLUMN
SEGMENT A

SEGMENT A

Title

PL3 PL3 BIG BEAST STAGE CONNECTION


DETAILS OPTION A
STIFFENER TO HAVE THE SAME BASE PLATE BASE PLATE
THICKNESS AS THE BEAM'S FLANGE SIZE (TBC) SIZE (TBC)

Date Drawn
02/06/23 Jo.Na
C1 E1
TYPICAL CONNECTION OF TOWER COLUMN SEGMENTS SECTION TYPICAL BASE CONNECTION OF TOWER COLUMNS SEGMENTS SECTION -
Scale at A1 Designer
- SCALE 1 : 10 SCALE 1:10 As indicated Ma.Ch
SCALE 1 : 10 SCALE 1:10
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:40 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12007 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

SUPPORTED BEAM SUPPORTED BEAM KEY PLAN

SUPPORTING BEAM

n1 ROWS OF BOLTS

SUPPORTING COLUMN
n1 ROWS OF BOLTS

1 2
DETAIL DETAIL
SCALE 1 : 10 SCALE 1 : 10
TYPICAL FLOOR BEAM CONNECTION

NOTES :

1. STEEL CONNECTIONS OF THE VIB/MEP AREAS TO BE DESIGNED BY THE STEEL FABRICATOR. TYPICALTYPES ARE SHOWN ABOVE. DESIGN FORCES WILL FOLLOW WITH THE IFC ISSUE.
2. OPTION B - CONNECTIONS BELOW INDICATE ALTERNATIVE CONNECTION TYPES TO BE USED AS AN ALTERNATIVE TO OPTION A (SEE DRAWING 12007).

8-M30 8.8/TB

25THK. END PLATE 180


3A

70
4

160
168

630
15THK. STIFF PLATE A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
Rev Revision Description By App Date
180

3B SCALE 1 2 3 4
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
5 6 7 8

160
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or

72
damage however caused which you or any other party may directly or indirectly suffer in connection
25THK. END PLATE 15THK. STIFF. with your access to or use of that information or data.
180

PLATE (TYP.) RBG provides this information for the express purpose contemplated by the underlying
25THK. END PLATE terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
95 215 95 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
170 licence to use the intellectual property rights for the express purpose.
215
405 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

Robert BirdGroup
Member of the Surbana Jurong Group
3 3A 5 6
DETAIL SECTION DETAIL SECTION DUBAI OFFICE
Robert Bird Group Pty Ltd
SCALE 1 : 10 Ibn Battuta Gate
Ph: +971 (0) 4 447 1866

SCALE 1 : 10 SCALE 1 : 10 SCALE 1 : 10 Level 4, Office Suite 415


Email:
Web:
MENA@robertbird.com.au
www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

25THK. END PLATE MDLBEAST


25THK. END PLATE
15THK. STIFF
PLATE (TYP.)
115

Project

SOUNDSTORM 2023
170

213
HOLE PLATE PIN/BOLT
TYPICAL CONNECTIONS No. ADDITIONAL NOTES
DIA (mm) GRADE DIA (mm) fy fu
115

TOWER BEAM 720 33 S355 30 640 640 END PLATES TO BE Z35 GRADE
TOWER COLUMN 144 33 S355 30 640 640 END PLATES TO BE Z35 GRADE

4-M30 8.8/TB Title


94 215 94
BIG BEAST STAGE CONNECTION
DETAILS OPTION B

3B 4
DETAIL SECTION Date Drawn
SCALE 1 : 10 SCALE 1 : 10
02/06/23 Jo.Na
Scale at A1 Designer
1 : 10 Ma.Ch
TYPICAL BEAM TRUSS MEMBER CONNECTION
TYPICAL TOWER COLUMN CONNECTION Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:41 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12008 A01


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

1500mm RC STRIP FOOTING WITH LIQUID


BITUMIN (2 LAYERS)
BITUMIN TO BE APPLIED TO THE BOTTOM 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
AND SIDE SURFACES OF THE FOOTING COUT NR
C
E IV E
S R
E COUT NR E
C
E IV E
S R
COUT NR
C
E IV E
S R
E

KEY PLAN

REFER PLAN
DEPTH
FORM 15 WIDE x 25 DEEP REBATE.
INSTALL FOAM BACKING ROD &
FILL WITH APPROVED SEALANT
(MIN 10mm DEEP) 25 DEEP SAW CUT REMOVE (CUT) EVERY
T12-200 DOWELS WITHIN 12 HOURS OF SECOND WIRE OF
1T12 TRIMMER LAP POURING REINFORCEMENT MESH FOR
500 AS REQ'D & AT (500 LONG)
A LENGTH OF 100 (50 EACH
CORNERS SIDE OF JOINT)
POLYTHENE SLIP MEMBRANE (MINIMUM 0.2mm
THK AND OF MEDIUM IMPACT RESISTANCE)

50mm THICK BLINDING SAND BLINDING


100THK UNBOUND
COMPACTED SOIL GRANULAR SUB-BASE
POLYETHYLENE SHEET SUB GRADE 50 50

TYPICAL FOUNDATION DETAIL TYPICAL SLAB ON GRADE DETAIL CONSTRUCTION JOINT (CJ) SAW JOINT (SJ)
SCALE 1:20 SCALE 1:20 SCALE 1:20 SCALE 1:20
(AT EVERY GRIDLINE UNO)
(AS MENTIONED ON DRAWING UNLESS AGREED OTHERWISE)

FACE OF EXISTING FOUNDATION TO BE ROUGHENTED


TENSION LAP NEW FOUNDATION REINFORCEMENT
EXISTING FOUNDATION (REFER TO TABLES)
REINFORCEMENT
REFER PLAN
DEPTH

EXISTING FOUNDATION

REFER PLAN
DEPTH
NEW FOUNDATION

EXISTING FOUNDATION
REINFORCEMENT A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
POST INSTALLED DOWEL BARS. NEW FOUNDATION REINFORCEMENT Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
BAR SIZE AND SPACING TO (REFER TO TABLES) accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
MATCH EXISTING. matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
TYPICAL REINFORCEMENT DETAIL BETWEEN NEW AND EXISTING FOUNDATION RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
SCALE 1:20 information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
DE-BONDED SLEEVE Engineering Consultant

15mm ISOLATION JOINT


T12-150, 500mm LONG DOWEL
Robert BirdGroup
TO FULL SLAB ON GRADE Member of the Surbana Jurong Group
PERIMETER DUBAI OFFICE
175 THICK SLAB ON GRADE Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866

+673.485m WITH A393 TOP MESH


Ibn Battuta Gate Email: MENA@robertbird.com.au
GROUND FLOOR LEVEL Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
175

+673485.000 (TBC) PO Box 118570


250

Dubai, United Arab Emirates TRADE LICENCE 597197

Client

500 75 SLAB ON GRADE MDLBEAST

T12-200
1500

T12-200
T16-100
Project

SOUNDSTORM 2023

Title

TYPICAL FOUNDATION DETAILS

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer

A 1 : 20 Ma.Ch
SECTION Design Checker
SCALE 1 : 20 Ja.Hu
Approved
Ra.Ma

02/06/2023 6:21:43 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12009 A01


MEMBER

ST
B ....... BEAM

AG
E
D
C
G

D
C

G
G
G
G
D
C

SC ....... STEEL COLUMN


VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN
A B C D E F G H J K
STEEL COLUMN SCHEDULE
2400 8200 2400 11200 3600 11200 2400 8200 2400
MARK SIZE
a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
f UC203x203x60

e
j
VB1 VB1

e
e

j
g UC203x203x46

SC
UC152C

SC
j
UC152B UC152C

SC
SC
UC152B
SC

SC

j
SC

SC
j UC254x254x89

UC152B

UC152B

UC152B
UC152C

UC152C

UC152C
UC152C

k UC254x254x73

UC152B
m UC305x305x137
n UC305x305x118 GENERAL NOTES
VB1 UB457F

j
e

VB1

SC

SC

e
p UC305x305x97

j
UC152B UB457F UC152C 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
SC

UC152C

SC
j
UC152B

SC

SC
2 q UC356x368x177 METERS UNLESS NOTED OTHERWISE.
e

r UC152x152x30

e
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
SC

SC
FPS100x10 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
FPS100x10 DIMENSIONS ARE TO BE FOLLOWED.
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
UB356D

STEEL FRAMING SCHEDULE

UB356D
UB356D

UB356D
UB356D

UB356D

UB356D
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

UB356D

UB356D

UB356D
UB356D

UB356D
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A M9307-RBG-PS007-ZZ-DR-ST-0003.
MARK SIZE
VB2

CHS244F UKCHS244.5x10 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

VB2
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
8900

FIS_248A FABRICATED BEAM (REFER TO SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
TABLES FOR DIMENSIONS)
UB178A UB178A UB178A UB178A UB178A5 7N UB178A UB178A UB178A UB178A UB178A
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
4 FIS_248B FABRICATED BEAM (REFER TO FULLY WELDED AT CONNECTION POINTS.
UB178A UB

p UB178A
UB178A TABLES FOR DIMENSIONS)
p UB178A

UB178A UB178A UB178A UB178A UB178A FPS100x10 FPS100x10 UB178A UB178A UB178A
UB178A UB178A FPS100x10 FPS100x10 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
A ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
8 UB178A UB178A UB457F UB1

p
UB356D UB178A UB178x102x19
17
p

SC
A UB457F UB457F UB457F
SC

C
7 8 U B A UB457N S 78 UB254C UB254x146x31 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
1 8 A UB UB UB UB UB A
UB A A

SC
17 78 1
VB2

VB2
78 78 1 1 U UB356D UB356x171x45

p
17 78 78 78 1
SC

1 A B 1 1 A B1 78

SC
78 U UB B 78 8A A UB 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
UB U A UB A A U 78 A UB457F UB457x191x82

8A
1 1 17

UB457N
7N A UB
UB

8A UB 8A B 78 17 B1 TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

A
A 8A UB457N UB457x152x52

17
5 A U 1 8A UB 78 17

48
7
35

7 4 78 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).


3 1 1 8 B UB

8A
UB
B B B 7 U 1 A 8

_2
6D

U 1 1 UB 78 A UC152A UC152x152x51
UB

U U A UB 17 UB
8A

17
8A UB 8A

FIS
78 UB 1 A UB
35

7 8 1 UC152B UC152x152x44

UB
7 1 1 7 17 7 45 A 78
FIS

1 UB 1 UB 8A
UB
6D

A UB
UB

UB457N
A UB 78 8A 7N A UC152C UC152x152x37
_2

8 17
UB457N

7 1 1 78

A
48

1 A 8A UB U
UB
p
p

48
UC152D UC152x152x30
78

p
UB A A UB B1 A
A

17
SC
SC

UB

SC
8 78

_2
7 B1 A 17 8 78 UB UC152E UC152x152x23
1 1 1

FIS
A
UB

U 8 8A U A
UB
FIS

17 UB 78 B4 17

8A
35

UB UC203D UC203x203x86

p
B A A 5 8A
_2

UB178A A 48

SC
U 7 UB
6D

17
8 17 UB
48

7 _2 UB N UC203E UC203x203x71

A
8A 17

UB
A 1 UB 17
FI S
A

A 17

48
78 UB A 78 78
A U 8 8A UC203F UC203x203x60
FIS

A 1 8 8A 1

_2
8 B A 7 1 1 FIS 78 B1 A
17 UB

FIS
B1
_2

U 78 UB UB178A _2 A 78 UC203G UC203x203x52

B
UB
48

UB457N
UB

48
1 U 48 A
UB A UB UC203H UC203x203x46
A

17
FIS

_2
9500

A 78 UB A

A
8A 17

FIS
UB 8A

UB457N
8 1
_2

48
7 B 7 UC254D UC254x254x89
A UB 17 17 UB 8A

p
48

1 U 8 1

_2
UB UB
FIS

8A 17 8A

SC
17 8A 17 UC254E UC254x254x73
B

FIS
p

7 B 78 8A UB
_2

SC
1 U UB UB 8A
SC

B 1 UC305E UC305x305x137
48

A 17
UB
UB457N

U 78 A 17 17 8A
A

B
UB178A A 78 8A UB 8 UC305F UC305x305x118

48
1 UB

A
B A 8 1 U 1 A U

48
FIS

17 UB

_2
A U 8 8A UB 78 17 B1 UC305G UC305x305x97
17 8A B1
UB457N

78
FIS

UB

_2
FIS
78
_2

1 B 17 1 7 8A 17 7 A F 8A
IS_

FIS
UB 8A UC356U UC356x368x177
48

A
_2

B U A B A U B 1 7 UB178A 8A UB UB178A
U 8 U 78 24
48

17
A

A 24 UB UB 17 VB1 70 DIA BAR OR MACALLOY


78 1 8A 8A
B

_ A B 17 UB 8A

B
1 A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
FI S
FIS

8 UB 460 M76 (OR EQUIVALENT)

48
UB178A UB 8A 17 U
8A UB 8A 17
_2

7 A 1

_2
1 U B 8 7 UB 78 17 8A VB2 80 DIA BAR OR MACALLOY Rev Revision Description By App Date

q
48

1 8A

FIS
UB 17

A
B 8A
q

17 A UB SCALE 1 2 3 4 5 6 7 8

SC

SC
48
460 M76 (OR EQUIVALENT)

B
B
FIS

UC152D B A U 7 UC152D
SC

48
U 8 1 8A 17 Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
4

_2
UB UB
17 UB
_2

FIS

_2
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
A 8A

FIS
8 B 17 17
48

A You are responsible for verifying that any information or data supplied or transferred by electronic means

FIS
7 UB
q

_2

UC152D

UC152D
8 8A 8A
B1 NOTES:
UC152D

UC152D

8A
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
A

17
SC

17
48

liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
B U 7 8
2400

U 1 A A or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UB N 178 A UB178A
UB457 *FPS100x10 TO BE TACK WELDED damage however caused which you or any other party may directly or indirectly suffer in connection

UB457

TY 0
with your access to or use of that information or data.

90
N
UB

P
ON THE BOTTOM FLANGE OF
PS007-ZZ-DR-ST-14012 RBG provides this information for the express purpose contemplated by the underlying
UC152D UC152D THE MAIN BEAMS

B
UB terms of engagement for the project which must not be used for any other purpose. The
FIS

5 A

48
78
information is not a contractual document. Unless otherwise agreed in writing by RBG,
17
_2

_2
all intellectual property rights in any information supplied by RBG are owned by, or
1 8A

q
UB
48

FIS

q
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable

SC
q
q

SC
9 0 YP
B

licence to use the intellectual property rights for the express purpose.
SC
SC

0
T

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

TFW
Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE

TFT
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au

D
12000

Level 4, Office Suite 415 Web: www.robertbird.com

BFT
Jebel Ali, Dubai
PO Box 118570
WT Dubai, United Arab Emirates TRADE LICENCE 597197

Client

BFW MDLBEAST

FABRICATED
'I' SECTION (FIS)
LENGTH
Project

TFT
SOUNDSTORM 2023
6

D1
2700

D
Title

7 BIG BEAST STAGE VIB LEVEL 1

BFT
STEEL FRAMING PLAN
LONGITUDINAL
'I' SECTION (FIS)
Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
FABRICATED I SECTIONS As indicated Ma.Ch
Design Checker
VIB LEVEL 1 - STEEL FRAMING PLAN BEAM REF DEPTH 'D' DEPTH 'D1' SIZE Volume WEIGHT 'TFW' TOP FLANGE WIDTH
'TFT' TOP FLANGE 'BFW' BTM FLANGE 'BFT' BTM FLANGE 'WT' WEB WEB TO FLANGE WELD ADDITIONAL Ja.Hu
SCALE 1 : 100 THICKNESS WIDTH THICKNESS THICKNESS WELD NOTES NOTES Approved
FABRICATED BEAM (REFER TO Ra.Ma
FIS_248A 1000 1000 7.29 m³ 57203.91 kg 250 25 250 25 20 12 - -
TABLES FOR DIMENSIONS)

02/06/2023 6:21:47 PM
FABRICATED BEAM (REFER TO
FIS_248B 1000 500 1.89 m³ 14850.16 kg 250 25 250 25 20 12 - -
TABLES FOR DIMENSIONS) FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12010 A01


MEMBER

ST
B ....... BEAM

AG
E
D
C
G

D
C

G
G
G
G
D
C

SC ....... STEEL COLUMN


VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

A B C D E F G H J K
STEEL COLUMN SCHEDULE
2400 8200 2400 11200 3600 11200 2400 8200 2400
MARK SIZE
a UC152x152x51
c UC152x152x23
d UC203x203x86
e UC203x203x71
f UC203x203x60
g UC203x203x46

j
VB1

d
VB1

SC
UC152E UC152D

d UC152E C d
UC152E j UC254x254x89

SC

SC
UC152D

j
UC152E d

SC
1

d
SC
SC

SC
UC152E k UC254x254x73

UC152E
UC152D

UC152D
UC152D

UC152D
m UC305x305x137
GENERAL NOTES
2400

n UC305x305x118
p UC305x305x97
d

VB1 UB457F
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
VB1 UB457F

j
SC

SC

SC
UC152E UC152D UC152D UC152E q UC356x368x177 METERS UNLESS NOTED OTHERWISE.

j
j
2

d
SC

SC
SC

SC
r UC152x152x30
d

UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
SC

FPS100x10 FPS100x10 DIMENSIONS ARE TO BE FOLLOWED.


UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

UB356D
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A STEEL FRAMING SCHEDULE SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

UB356D
UB356D

UB356D

UB356D

UB356D

UB356D

UB356D

UB356D

UB356D

UB356D
UB356D
M9307-RBG-PS007-ZZ-DR-ST-0003.
MARK SIZE
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
CHS244F UKCHS244.5x10 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
FIS_248A FABRICATED BEAM (REFER TO SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

VB2
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
8900

VB2

TABLES FOR DIMENSIONS) PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE


FIS_248B FABRICATED BEAM (REFER TO FULLY WELDED AT CONNECTION POINTS.
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
TABLES FOR DIMENSIONS)
UB254C FPS100x10 FPS100x10 UB254C FPS100x10 FPS100x10 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

SC UB254C
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
UB254C

ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.


UB178A UB178x102x19
A UB356D

p
p

p
78 UB356D UB457F UB457F UB1

SC

SC
SC

UB457F UB254C UB254x146x31


SC

8 A UB457F 1 UB457F 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

p
7 U B A UB 78

SC
1 8 UB UB UB UB A UB356D UB356x171x45
8A

p
UB 8A 17 8A 1
VB2

VB2
7 B 7 7 17 17 17 7 UB 17 UB457F UB457x191x82 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
B1 A U 1 1 A 8A 8A 8
8 B 7N B 78 8A A 17 8A UB

UB457N
8 A U 7 U 5 U A UB UB 8A 17 UB457N UB457x152x52
TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
1 1

6D
17 8A B4 U
UB

B 8A B 78 17 17 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).

A
B U U B1 8A

35
7 U A 8A UB

UB457N
1

48
7
35

U 1 UC152A UC152x152x51
3 UB
1 78 UB UB 8A 78

6D
UB
UB 1

_2
6D

1 A UB 78 A
UB

A UB
UB457N

A B 78 17 UC152B UC152x152x44

35
A

FIS
8 UB UB
FIS

8 7 U 8 1 A

UB457N
35

7 1 1 78 8 1

UB
7 17 45 A 78
1 UB UC152C UC152x152x37
_2

UB B1 UB
UB
6D

A 8A 8A A 7N UB A
48

8 U 7 17 17 UC152D UC152x152x30
17 B1
A

A 8A UB U 8A
p
p

p
B 8 UB B1

A
U A 7 U 8A 17 UC152E UC152x152x23
SC
SC

UB

SC
48
1 78 B 1 A 7 17 17 8 78 UB

_2
U 8 1 A UB A UC203D UC203x203x86
UB

UB 8A
FIS

17 UB 17

FIS
UB178A UB 8 45

6D
p
A
35

N B A 8A
_2

UC203E UC203x203x71
7 A 48

SC
5 U 8 UB 17 7N UB

35
UB
6D

48

8 A 4 7 _2 8A 17
UB A B1 17 UC203F UC203x203x60

UB
17

A
17 UB UB
FI S
A

8A
FIS

78

48
B 1 U 8A 7 8A 17 8A 1 U 8 8A
A
_2

U FIS UC203G UC203x203x52

_2
B A 17 B1 1 7 8A 78 B1
U 8
48

FIS
U UB _2 A 78
UB

B
17 UB UC203H UC203x203x46

48
A

B A 48 A UB
1

_2

4E
9500

U 78 A
p

7 UC254D UC254x254x89
A A UB

UB457N
17

FIS
UB 8A
SC

25

A
8 1
k

78

p
UB457N

7 B

48
A UB 17 8A UC254E UC254x254x73
SC

17

UC
UB
FIS

SC
1 U 8 1
UB UB 8A

_2
A 7 17 8A 17

k
78 B1 48A A
_2

UC305E UC305x305x137

FIS
78 8A UB

SC
FIS

8A
48

1 U UB UB

UB457N
B A 2 1 17 UC305F UC305x305x118
IS_ UB
_2
A

U 78 A 17 17
UB457N

8A

B
78
48

F A 8A U 8A

48
B1 8 1 B1 UB UB UC305G UC305x305x97
A 8A
B

UB178A U
FIS

17 UB

_2

A
A U 7 8 A 7 UB U B1 7 1 7 17

48
8 B B1 8A UC356U UC356x368x177

FIS
8
_2

17 1 U 1 17 78 FIS 8A
UB 17 UB 7 8A

_2
U
48

8A 8A U
UB B A 8A B1 A _ UB178A VB1 70 DIA BAR OR MACALLOY

FIS
2 B
A

A U 8 7 UB 17
FIS

8 7 1 78 48 460 M76 (OR EQUIVALENT) A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
17 8A B1 UB 17 A UB 8A

B
A
_2

UB

48
A
FIS

B 7 U A UB 8A 1 VB2 80 DIA BAR OR MACALLOY Rev Revision Description By App Date


48

U 8 1
17 8A 78 17 7

_2
UB178A UB
_2

q
UB 17 8A SCALE 1 2 3 4 5 6 7 8
B

1 A 460 M76 (OR EQUIVALENT)

FIS
B 7 8A

SC
q
48
q

U 1 UB 78 17 UB 8A Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the

48
B

SC
FIS

UB UC152E
SC

UC152E A
B

48
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
8 1 8A 17
4

_2
UB UB
17 UB
_2

You are responsible for verifying that any information or data supplied or transferred by electronic means
FIS

_2
A 8A

FIS
8 B 17 17 NOTES: matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
48

FIS
7
_2

8 U N

UC152E

UC152E
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
8A 8A
B1 8A UB457 UB
A

17
q
UC152E

UC152E

48

or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
SC

B U 7 1 *FPS100x10 TO BE TACK WELDED


2400

damage however caused which you or any other party may directly or indirectly suffer in connection
B

U 1 A UB 78
UB
with your access to or use of that information or data.
78 A

TY 0
A 17 U ON THE BOTTOM FLANGE OF

90
FIS

1 B

q
4

P
RBG provides this information for the express purpose contemplated by the underlying
8A 57N
UB THE MAIN BEAMS

SC
terms of engagement for the project which must not be used for any other purpose. The
_2

PS007-ZZ-DR-ST-14012 information is not a contractual document. Unless otherwise agreed in writing by RBG,
UC152E

B
UC152E
48

5 A

48
all intellectual property rights in any information supplied by RBG are owned by, or
78
B

licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable

_2
1

q
licence to use the intellectual property rights for the express purpose.
UB

FIS
q

SC
SC

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


SC

REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE


Structural, Civil & Construction
Engineering Consultant

TFW
Robert BirdGroup
Member of the Surbana Jurong Group
DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866

TFT
Ibn Battuta Gate Email: MENA@robertbird.com.au

D
Level 4, Office Suite 415 Web: www.robertbird.com
12000

Jebel Ali, Dubai

BFT
PO Box 118570
WT Dubai, United Arab Emirates TRADE LICENCE 597197

Client

BFW
MDLBEAST

FABRICATED
'I' SECTION (FIS)
LENGTH Project

TFT
SOUNDSTORM 2023

D1
2700

D
Title

BIG BEAST STAGE VIB LEVEL 2


7 STEEL FRAMING PLAN

BFT
LONGITUDINAL
'I' SECTION (FIS)
Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
VIB LEVEL 2 - STEEL FRAMING PLAN FABRICATED I SECTIONS Design Checker

SCALE 1 : 100 Ja.Hu


'TFT' TOP FLANGE 'BFW' BTM FLANGE 'BFT' BTM FLANGE 'WT' WEB WEB TO FLANGE WELD ADDITIONAL Approved
BEAM REF DEPTH 'D' DEPTH 'D1' SIZE Volume WEIGHT 'TFW' TOP FLANGE WIDTH
THICKNESS WIDTH THICKNESS THICKNESS WELD NOTES NOTES
Ra.Ma
FABRICATED BEAM (REFER TO
FIS_248A 1000 1000 7.29 m³ 57203.91 kg 250 25 250 25 20 12 - -

02/06/2023 6:21:52 PM
TABLES FOR DIMENSIONS)

FIS_248B 1000 500


FABRICATED BEAM (REFER TO
1.89 m³ 14850.16 kg 250 25 250 25 20 12 - -
FOR TENDER
TABLES FOR DIMENSIONS)
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12011 A01


MEMBER

ST
B ....... BEAM

AG
E
D
C
G

D
C

G
G
G
G
D
C

SC ....... STEEL COLUMN


VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

A B C D E F G H J K
KEY PLAN

2400 8200 2400 11200 3600 11200 2400 8200 2400


STEEL COLUMN SCHEDULE

MARK SIZE
a UC152x152x51
c UC152x152x23
d UC203x203x86

d
VB1 VB1

SC

SC
e UC203x203x71

SC
UC152E

SC
UC152E UC152D
d

SC

SC

SC
UC152D
1
SC

f UC203x203x60

n
SC

UC152E
UC152E
UC152E

UC152E

UC152D

UC152D

UC152D

UC152D
g UC203x203x46
UB356D
FPS100x10
2400

FPS100x10 j UC254x254x89
FPS100x10 k UC254x254x73

j
n

n
d

SC j

SC

SC
SC
UB457F VB1 UB457F VB1

d
SC
m UC305x305x137

SC

SC
SC
UC152E

SC

SC

SC

SC
UC152E UC152D UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC152D

SC

SC
2 GENERAL NOTES

SC
n UC305x305x118
d

UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A p UC305x305x97 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
SC

UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A


q UC356x368x177 METERS UNLESS NOTED OTHERWISE.
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A FPS100x10 r UC152x152x30
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

UB356D
UB356D
UC254E

UC254E

UC254E

UC254E

UC254E

UC254E

UC254E

UC254E

UC254E
DIMENSIONS ARE TO BE FOLLOWED.
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
UB356D

UB356D

UB356D

UB356D

UB356D

UB356D

UB356D
UB356D

UB356D

UB356D
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
STEEL FRAMING SCHEDULE
VB2

SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

VB2
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A M9307-RBG-PS007-ZZ-DR-ST-0003.
8900

UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A MARK SIZE
FPS100x10 FPS100x10 CHS244F UKCHS244.5x10 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A
UB254C

FIS_248A FABRICATED BEAM (REFER TO SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
UB254C UB254C TABLES FOR DIMENSIONS) PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A UB178A

UB254C
FIS_248B FABRICATED BEAM (REFER TO FULLY WELDED AT CONNECTION POINTS.
A
UC

78 UB356D UB457F UB457F UB1 TABLES FOR DIMENSIONS)


8A UB457F UB1 UB457F UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G UB457F
30

78 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
7 A U FPS100x10 FPS100x10
5G

1 8 A UB B1 UB UB UB A ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.


UB A 17 A
78 1
VB2

VB2
78 78

n
1

SC
UB UB178A UB178x102x19

n
B 17 78 7 78 17

n
SC
A

SC
A 1 1

p
U

SC
1 8

n
8 U B 7N B 78 8A A A 17 8A UB

SC

SC

SC

SC

SC
B

UB457N
A UB B4 A

SC
7 U UB254C UB254x146x31

SC
U

p
8 U 1 5 1 A UB 8A 17 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

6D
17 8A B4 57 U
UB

B 8A B 78 FPS100x10 FPS100x10 17 17

A
B U U N B1 8A UB356D UB356x171x45

35
7 U A 1 8A UB

48
7
35

3 U 1 8 8A 78
UB

6D
1 UB
UB

UB
UB 17 1 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

_2
6D

A UB 78 A UB457F UB457x191x82
UB

A UB

UB457N
35
A 78 17

UB457N
B A

FIS
8 UB
FIS
8 7 U 8 1 A U TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
35

1 8 1

UB
7
UB457N

1 7 17 78 B A 78 UB457N UB457x152x52
1 N UB
_2

UB B1 UB 45 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).


UB
6D

A 57 8A 8A A UB A
48

p 5G
8 4 U 7 17 7N 17 UC152A UC152x152x51
17 UB B1
A

SC C30
8A IN 8A UB U 8A
p

48
UC152B UC152x152x44
UB 78
A 7 U A SC UB UB 17 B1
78

_2
B1

U
17 78
p

FIS

1 A 17 8 UB UC152C UC152x152x37

FIS
1 ABEYANCE A
UB

8 A
SC

U 8A
UB UB 17
_2

UB178A 17 8A UB

p
35

UB

6D
N A 8A UC152D UC152x152x30
UB457N
48

B A 48

SC
7 U 4 UB
6D

5 8 UB 17

35
UB 57
A

8 A 4 7 _2 8A 17 UC152E UC152x152x23
UB A B1 17 N

UB
17

A
17 UB UB
78 FI S A

48
B 1 U 8A 78 17 8A 17 UB 8A 8A UC203D UC203x203x86
FIS

U UB

_2
B A 7 1 8A FIS 8A 17
N U 78 B1 UB

FIS
57 45 UC203E UC203x203x71
_2

B
A _2 8A
UB457N

UB

48
1 U 78 7N
48

4 B A 48
UB 17 U UC203F UC203x203x60

_2
9500

U 8 1
A

UB B
k

A 17 UB A

A
8A 17

FIS
UB 8A
78
SC

48
B 7 17 UC203G UC203x203x52
A UB 8A
p

p
1 U 8 1 17 UB

_2
FIS

UB UB
SC

FIS

8A

SC
8A 17 17 8A 17 UC203H UC203x203x46

k
A

FIS
_2

7 B 78 UB

SC
8A
_2

1 U UB UB 8A
48

UC254D UC254x254x89

UB457N
B 1
48

A 17
UB178A U 78 UB A 17 17
B

8A
A

B
78 UB

A
A 8A 8 UC254E UC254x254x73

48
1 UB

UB457N
48
B A 8 1 A U 1 A U
17 8A UB

_2
8A U 78 78 UB UB 78 17 B1 UC305E UC305x305x137

_2
B1
FIS

FIS
1 7 1 8A 17 A 8A 78

FIS
7 B U B1 B 17 7 F
_2

B1 U A A U 7 8A 8A UB 8A IS_ UB A UC305F UC305x305x118


1
48

U 8 U 8 24
8A 24 17 UB 17 UB 17
FIS

UC305G UC305x305x97
A

7 _ A B 8A 17 8A UB 8A

B
_2

1 FI S 8 U UB

48
8A
FIS

UB 8A UC356U UC356x368x177
17 8A UB 1
48

7 A 17 7

_2
B
_2

1 8 7 UB 17 8A
B

U VB1 70 DIA BAR OR MACALLOY

q
1 8A

FIS
UB 17 8A

A
48

B 17 8A
q

SC

SC
UB

48
B
U 7 A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
B A 460 M76 (OR EQUIVALENT)
FIS

UC152E
SC

UC152E

48
U 8 1 8A 17
4

_2
UB UB
17 U
FIS
_2

_2
A Rev Revision Description By App Date
8A

FIS
8 B 17 B VB2 80 DIA BAR OR MACALLOY
A 17
48

FIS
q

7
_2

8 U 8A SCALE 1 2 3 4 5 6 7 8
B1 UB 460 M76 (OR EQUIVALENT)

UC152E

UC152E
17 8A
SC

8A
A

48
UC152E

UC152E

Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
B U 7 UB 17
2400

U 1 A accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

UB N 178 17 UB45 8

TY 0
7 A A NOTES:
You are responsible for verifying that any information or data supplied or transferred by electronic means

90
4 5 8A 7N matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be

P
U B
UB
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
PS007-ZZ-DR-ST-14012
FIS 9 0 YP

or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UC152E

B
UC152E *FPS100x10 TO BE TACK WELDED
5

48
damage however caused which you or any other party may directly or indirectly suffer in connection
_2 0

with your access to or use of that information or data.


ON THE BOTTOM FLANGE OF

_2
48
q

FIS
RBG provides this information for the express purpose contemplated by the underlying
THE MAIN BEAMS

q
q

B
SC

terms of engagement for the project which must not be used for any other purpose. The

SC

SC
SC

information is not a contractual document. Unless otherwise agreed in writing by RBG,


all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

TFW DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

Robert BirdGroup

TFT
D

BFT
Member of the Surbana Jurong Group
WT
12000

DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
BFW Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

FABRICATED Client
'I' SECTION (FIS) MDLBEAST
LENGTH

TFT

D1
Project
6 SOUNDSTORM 2023

D
2700

BFT
7 LONGITUDINAL Title

'I' SECTION (FIS) BIG BEAST STAGE MEP LEVEL 3


STEEL FRAMING PLAN

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
MEP LEVEL 3 - STEEL FRAMING PLAN As indicated Ma.Ch
SCALE 1 : 100 Design Checker
FABRICATED I SECTIONS
Ja.Hu
'TFT' TOP FLANGE 'BFW' BTM FLANGE 'BFT' BTM FLANGE 'WT' WEB WEB TO FLANGE WELD ADDITIONAL Approved
BEAM REF DEPTH 'D' DEPTH 'D1' SIZE Volume WEIGHT 'TFW' TOP FLANGE WIDTH
THICKNESS WIDTH THICKNESS THICKNESS WELD NOTES NOTES Ra.Ma
FABRICATED BEAM (REFER TO

02/06/2023 6:21:57 PM
FIS_248A 1000 1000 7.29 m³ 57203.91 kg 250 25 250 25 20 12 - -
TABLES FOR DIMENSIONS)
FABRICATED BEAM (REFER TO FOR TENDER
FIS_248B 1000 500 1.89 m³ 14850.16 kg 250 25 250 25 20 12 - -
TABLES FOR DIMENSIONS) Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12012 A01


MEMBER

ST
B ....... BEAM

AG
E
D
C
G

D
C

G
G
G
G
D
C

SC ....... STEEL COLUMN


VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

A B C D E F G H J K
KEY PLAN

STEEL COLUMN SCHEDULE

2400 8200 2400 11200 3600 11200 2400 8200 2400 MARK SIZE
a UC152x152x51
c UC152x152x23
d UC203x203x86
UC152E VB1 UC152D VB1 e UC203x203x71
UC152D UC152E
1 f UC203x203x60

UC152D
g UC203x203x46
UC152E

UC152D

UC152D
UC152E

UC152E

UC152E
UC152D
2400

j UC254x254x89
k UC254x254x73
UC152E VB1 UC305G UC305G VB1 m UC305x305x137
UC305G UC305G UC305G UC305G UC305G UC305G UC152D GENERAL NOTES
2 UC152D UC152E
n UC305x305x118

UC254E
p UC305x305x97 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
q UC356x368x177 METERS UNLESS NOTED OTHERWISE.

UC254E
FPS

UC254E

UC254E

UC254E

UC254E
FPS r UC152x152x30
100 10 10 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
x 10 10 x

UC254E
0x
x 100

UC254E
00 DIMENSIONS ARE TO BE FOLLOWED.

UC254E
1 10 PS
F PS F

UB178A
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

UB178A
UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
FPS FPS
STEEL FRAMING SCHEDULE SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

UC254E
0 10
0x 1 10 100 M9307-RBG-PS007-ZZ-DR-ST-0003.
8900

UC254E
10 0x 0x x MARK SIZE
FPS 10 10 10
F PS CHS244F UKCHS244.5x10

UC254E
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

UC254E

UC254E

UC254E

UC254E
FIS_248A FABRICATED BEAM (REFER TO SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

UC254E
TABLES FOR DIMENSIONS)

UC254E
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FIS_248B FABRICATED BEAM (REFER TO FULLY WELDED AT CONNECTION POINTS.
TABLES FOR DIMENSIONS)
UC305G UC305G UC305G UC305G UC305G UC305G 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
FPS100x10 FPS100x10
UC305G ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
1
VB2

VB2

UC305G

VB2

VB2
UB178A UB178x102x19
PS007-ZZ-DR-ST-14012 UB254C UB254x146x31 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
UB356D UB356x171x45
3 UB457F UB457x191x82 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
UB457N UB457x152x52
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC152A UC152x152x51
IN UC152B UC152x152x44
ABEYANCE UC152C UC152x152x37
UC152D UC152x152x30
UC152E UC152x152x23
UC203D UC203x203x86
UC203E UC203x203x71
UC203F UC203x203x60
9500

UC203G UC203x203x52
UC203H UC203x203x46
UC254D UC254x254x89
UC254E UC254x254x73
UC305E UC305x305x137
UC305F UC305x305x118
UC305G UC305x305x97
UC356U UC356x368x177
VB1 70 DIA BAR OR MACALLOY
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
UC152D UC152D 460 M76 (OR EQUIVALENT)
4 VB2 80 DIA BAR OR MACALLOY Rev Revision Description
SCALE 1 2 3 4 5 6
By App
7
Date
8
460 M76 (OR EQUIVALENT)
UC152D

UC152D
UC152D

UC152D
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
2400

accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or

5 UC152D UC152D
NOTES: damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
*FPS100x10 TO BE TACK WELDED terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
ON THE BOTTOM FLANGE OF all intellectual property rights in any information supplied by RBG are owned by, or
THE MAIN BEAMS licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
Structural, Civil & Construction
Engineering Consultant

Robert BirdGroup
Member of the Surbana Jurong Group
12000

DUBAI OFFICE
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197

Client

MDLBEAST

Project
6 SOUNDSTORM 2023
2700

7 Title

BIG BEAST STAGE MEP BRIDGE


LEVEL 4 STEEL FRAMING PLAN

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma
MEP BRIDGE LEVEL 4 - STEEL FRAMING PLAN

02/06/2023 6:22:00 PM
SCALE 1 : 100
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-12013 A01


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

GENERAL NOTES
K J H G F E D C B A
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.
2400 8200 2400 11200 3600 11200 2400 8200 2400
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
DIMENSIONS ARE TO BE FOLLOWED.
UPPER ROOF LEVEL UC203F UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203F 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

2E
+709485.000 (TBC)

UC

3F
2E
UC

E
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

15

2E

UC

UC203F
20
2E
20

UC

UC203F
UC152E
E

2
UC203F

UC
UC

UC152E
UC203F

15
2

15
2E

UC

UC
15
M9307-RBG-PS007-ZZ-DR-ST-0003.

15
3F

15
UC

UC152E

15
UC152E

15

15
UC152E

UC152E
15
15

UC
15

UC152E

UC
2E

UC

UC
2E
15

UC

UC
2E
2E

E
UC
3F
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

UC

20
UPPER ROOF BOTTOM

E
20
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

15

3F
CHORD PLAN UC203F

UC

2E
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
+706785.000 (TBC) UC203F UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203F FULLY WELDED AT CONNECTION POINTS.
UC152E MEMBER
2E B ....... BEAM 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
SIDE CLADDING: SKIN PVC ROLLER 5 ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
UC OR SIMILAR, SPANNING BETWEEN U C1 SC ....... STEEL COLUMN
15 VB ....... VERT CROSS BRACE

UC203G

UC203G
SECONDARY RAILS/GUIDES

UC203G

UC203G
2E 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
HB ....... HORIZ. CROSS BRACE
UC 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
E 15
1 52 VB1 2E TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
UC VB 1 LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC152E UC152E STEEL COLUMN SCHEDULE

E MARK SIZE
UC 2
15 15 a UC152x152x51
2E UC
UC203G

c UC152x152x23

UC203G

UC203G

UC203G
d UC203x203x86
UC e UC203x203x71
2E 15
5 2E f UC203x203x60
U C1 g UC203x203x46
UC152E UC152E j UC254x254x89
UC203H UC203H UC203H k UC254x254x73
LOWER ROOF LEVEL UC254D UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC254D UC203H UC203H UC203H
m UC305x305x137

2E

4D

UC
+697385.000 (TBC)
3H

UC

n UC305x305x118

15

2D

2D
2D
2D

UC203H
25
UC
2D

20
2D
20

2D

D
UC203H

UC254D

2D
UC254D
D

UC152E

UC152E
UC

UC

UC254D

UC
UC
UC
UC203H

UC254D

UC254D
25

UC203H
UC
UC

UC152D
UC152D

2
UC

UC

UC
2

15

15
p UC305x305x97

3H
UC152D
UC

15
15

UC152D

UC152E

UC152E

15
15

15
UC
15

15

15
15
UC152E

UC152E
4D
15

15

15
15
15

UC152E

UC152E

UC152E

UC152E
15

UC

UC
15

15
UC
UC

UC

2D
UC

UC
q UC356x368x177

UC
UC

UC
UC

15
2D

2D

2D
2

2D
4D
2D

LOWER ROOF BOTTOM PLAN

2D

2D
D

3H
20

UC
UC

2
25

r UC152x152x30

D
3H

20
25
15
UC

+694685.000 (TBC)

UC
4D
2E
LEVEL 4 UC152E UC203H UC203H UC254D UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC254D UC203H UC203H UC203H
+694085.000 (TBC) UC152D UC152D UC152E STEEL FRAMING SCHEDULE
UC

2E
2D
UC

MARK SIZE
15

15
15
15

SIDE CLADDING: SKIN PVC ROLLER SIDE CLADDING: SKIN PVC ROLLER SIDE CLADDING: SKIN PVC ROLLER
2E

UC
CHS244F UKCHS244.5x10

UC
2D

OR SIMILAR, SPANNING BETWEEN OR SIMILAR, SPANNING BETWEEN OR SIMILAR, SPANNING BETWEEN


SECONDARY RAILS/GUIDES UC152D SECONDARY RAILS/GUIDES UC152D SECONDARY RAILS/GUIDES FIS_248A FABRICATED BEAM (REFER TO
UC152E UC152E TABLES FOR DIMENSIONS)
MEP LEVEL 3 FIS_248B FABRICATED BEAM (REFER TO
2D

UC
2E

UC
TABLES FOR DIMENSIONS)
15
15

15
+691620.000 (TBC) A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23

15
UC

FPS100x10 FPS100x10
UC

2D
UC254D

2E
UC254D

A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

UC254D
UB178A UB178x102x19

UC254D

UC203D

UC203D
UC152E UC152D UC152D UC152E UB254C UB254x146x31
Rev Revision Description
SCALE 1 2 3 4 5 6
By App
7
Date
8
UB356D UB356x171x45 Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
UC203D

UC203D

accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

2D
UC

UC

UB457F UB457x191x82 You are responsible for verifying that any information or data supplied or transferred by electronic means

2E
15
15

15

matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be

15
UB457N UB457x152x52 liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information

UC
2E

2D

UC
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UC152A UC152x152x51 damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
VIB LEVEL 2 UC152E UC152D UC152D UC152E UC152B UC152x152x44 RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
+686697.500 (TBC) UC152C UC152x152x37 information is not a contractual document. Unless otherwise agreed in writing by RBG,
2D

UC
all intellectual property rights in any information supplied by RBG are owned by, or
UC152D UC152x152x30
2E

UC
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
15

15
15

15
licence to use the intellectual property rights for the express purpose.
UC152E UC152x152x23
UC

2D
UC

2E
UC203D UC203x203x86 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC152E UC152D UC152D UC152E UC203E UC203x203x71 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC203F UC203x203x60 Structural, Civil & Construction
UC152C UC152B UC152B UC152C Engineering Consultant
UC203G UC203x203x52
VB1

VB1

VB1
VB1

UC203H UC203x203x46
Robert BirdGroup
UC

2D
UC

2A

15
15

UC254D UC254x254x89

15
15

UC
2A

UC
2D

UC254E UC254x254x73 Member of the Surbana Jurong Group


UC305E UC305x305x137
VIB LEVEL 1 UC152C UC152B UC152B UC152C DUBAI OFFICE
UC305F UC305x305x118 Robert Bird Group Pty Ltd

UC203E
Ph: +971 (0) 4 447 1866

UC203E
+681172.500 (TBC) Ibn Battuta Gate Email: MENA@robertbird.com.au
UC305G UC305x305x97

UC
Level 4, Office Suite 415 Web: www.robertbird.com

UC
2A
2D

UC356U UC356x368x177 Jebel Ali, Dubai

15
15

15
15

PO Box 118570

2D
UC

2A
VB1 70 DIA BAR OR MACALLOY
UC

Dubai, United Arab Emirates TRADE LICENCE 597197


460 M76 (OR EQUIVALENT)

UC254D
UC254D
UC254D

UC254D
UC152C UC152B UC152B UC152C VB2 80 DIA BAR OR MACALLOY
Client

460 M76 (OR EQUIVALENT) MDLBEAST


UC
UC

UC203E

2A

2D
15
15

15

15
2A
2D

UC

UC
UC203E

NOTES:
*FPS100x10 TO BE TACK WELDED

UC
UC
2D

Project
2A

ON THE BOTTOM FLANGE OF

15
15
15

15

2D
THE MAIN BEAMS SOUNDSTORM 2023

2A
UC

UC

UC152C UC152B UC152B UC152C


GROUND FLOOR LEVEL
+673485.000 (TBC) PF1 PF2 PF1 S1 PF1 PF2 PF1
Title

BIG BEAST STAGE ELEVATION


ALONG GRID 1
ELEVATION ALONG GRID 1
SCALE 1 : 100

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:04 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14001 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

A B C D E F G H J K
GENERAL NOTES
2400 8200 2400 11200 3600 11200 2400 8200 2400 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.

UPPER ROOF LEVEL UC203F UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203F 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
DIMENSIONS ARE TO BE FOLLOWED.

3F

2E
+709485.000 (TBC)

UC
UC152E

UC203F
UC152E

UC152E

UC152E
20

2E

15

2E
E

UC152E
UC152E
UC203F

UC152E

20

UC203F
UC
UC203F

2
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

2E

UC

UC
UC

15

UC

2E

15
15

UC

3F
UC

E
15

15
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL

UC
15

UC

15
15

2
UC

UC
15
15
15

2E
UC
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

2E

2E
15
UC

2
UC
UC

3F
UC
2

E
UPPER ROOF BOTTOM M9307-RBG-PS007-ZZ-DR-ST-0003.

2E
E

20
15
20
CHORD PLAN

UC
2E
3F
UC203H UC203H UC203H UC203H 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
+706785.000 (TBC) UC203F UC203H UC203H UC203H UC152E SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
SIDE CLADDING: SKIN PVC ROLLER PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
E UC
2 15 FULLY WELDED AT CONNECTION POINTS.
15 OR SIMILAR, SPANNING BETWEEN

UC203G
2E
UC SECONDARY RAILS/GUIDES

UC203G
5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

UC203G
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
UC 2E

UC203G
15 5 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
2E VB1 U C1
VB 1 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
UC152E UC152E MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC B ....... BEAM
2 E 15
15 2E SC ....... STEEL COLUMN
UC VB ....... VERT CROSS BRACE

UC203G
UC203G
HB ....... HORIZ. CROSS BRACE

UC203G
UC 2E

UC203G
15 5
2E U C1
STEEL COLUMN SCHEDULE
UC152E UC152E
LOWER ROOF LEVEL UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC203H UC254D UC203H UC203H UC203H MARK SIZE
a UC152x152x51
3H

UC
UC

4D
+697385.000 (TBC)

UC

UC152E

UC254D

UC
UC152D

UC152D

UC152E

2D
UC152E

UC203H
2D
D

2D
UC254D

UC
UC203H

20

20
25
25

UC152D
UC254D c UC152x152x23

15

UC152D
2D

2D
UC152E

UC152E

UC152E

UC152E
UC152E

UC152E
UC152E
2
UC152D

UC

UC
2

15
UC

UC

15
UC

15
15
UC

3H
UC
4D

15

15
2E

UC

15
2D
2D
2D

15
d UC203x203x86

15

2D
UC

15

15

UC
UC

15

15
UC

UC
15

UC

UC
2D
15
15
UC
15

UC
15

2D
15

e UC203x203x71

2
2D
15

2E
2D
UC

D
4D

UC
2D

3H
D

UC
UC
UC

2D

15
2D

f UC203x203x60
20

25

25

20
UC
LOWER ROOF BOTTOM PLAN UC203H UC203H UC203H UC203H UC203H UC203H
3H

UC

4D

UC
g UC203x203x46
+694685.000 (TBC) UC152E UC203H UC203H UC152D UC203H UC203H UC203H UC152E
UC152D j UC254x254x89
LEVEL 4
UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G k UC254x254x73
UC254D

UC254D
2D

UC305F

UC305F

UC305F

UC305F
UC

UC305F
UC305F

UC UC UC 3F m UC305x305x137

UC
2E

UC
UC254D
UC305F
UC305F
15

20 F

UC305F
+694085.000 (TBC) 20 20 20 F 20 F
15

03 03

15

15
n UC305x305x118
3F 3F 3F 03
UC

3F 2 2 C
UC

2D

2E
2
UC UC U C p UC305x305x97
MEP LEVEL 3 UC152E UC152D UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC152D UC152E q UC356x368x177
+691620.000 (TBC) r UC152x152x30
UB

UC203D

UC203D
UB

6D

15 6D
35

2E
35

35

UC 35
2D
UC

6D

15
6D

UB

UB
15

UC

UC
2E

15

IN
2D

UC152E UC152D UC152E STEEL FRAMING SCHEDULE A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23

UC254D

UC254D
UC152D ABEYANCE A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
UC203D
UC203D

UC254D

MARK SIZE
UC254D

Rev Revision Description By App Date


2D
2E

UC

UC
CHS244F UKCHS244.5x10 SCALE 1 2 3 4 5 6 7 8
15
15

15

15
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
UC
UC

2D
FIS_248A FABRICATED BEAM (REFER TO

2E
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
TABLES FOR DIMENSIONS)
VIB LEVEL 2 UC152E UC152D UC152D UC152E FIS_248B FABRICATED BEAM (REFER TO
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
+686697.500 (TBC) TABLES FOR DIMENSIONS)

6D

D
damage however caused which you or any other party may directly or indirectly suffer in connection
UB

UB

UC 356
with your access to or use of that information or data.

35
35 2D

35

FPS100x10 FPS100x10
UC

2D

2E
RBG provides this information for the express purpose contemplated by the underlying
UC

UB

UB
6D

6D
15

terms of engagement for the project which must not be used for any other purpose. The

15

15
UB178A UB178x102x19
15

information is not a contractual document. Unless otherwise agreed in writing by RBG,


2E

UC
all intellectual property rights in any information supplied by RBG are owned by, or
UB254C UB254x146x31 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UC152E UC152D THE GAPS BETWEEN STRUCTURAL UC152D UC152E UB356D UB356x171x45 licence to use the intellectual property rights for the express purpose.
MEMBERS/SEGMENTS INDICATE
UC152C UC152B UC152C UB457F UB457x191x82 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
LOCATION OF CONNECTIONS UC152B
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE

VB1
UB457N UB457x152x52
VB1

(REFER TO DRAWING
VB1

VB1
M9307-RBG-PS007-ZZ-DR-ST-12001) UC152A UC152x152x51 Structural, Civil & Construction

UC

UC
2A
2D

Engineering Consultant

15

15
UC152B UC152x152x44
15
15

2A

2D
UC
UC

VIB LEVEL 1 UC152C UC152B UC152B UC152C


UC152C
UC152D
UC152x152x37
UC152x152x30 Robert BirdGroup
UC152E UC152x152x23 Member of the Surbana Jurong Group
+681172.500 (TBC)
UB

UB

6D

15 6D
UC203D UC203x203x86
UC203E

UC203E

DUBAI OFFICE

2D
UC

35 52A

35

35

UC B35
2A
UC

6D

6D

UC203E UC203x203x71

15
15

Robert Bird Group Pty Ltd

UB
Ph: +971 (0) 4 447 1866

U
1

UC
2D

Ibn Battuta Gate Email: MENA@robertbird.com.au


UC203F UC203x203x60 Level 4, Office Suite 415 Web: www.robertbird.com

UC254D
UC254D
UC203G UC203x203x52 Jebel Ali, Dubai
UC152B UC152B PO Box 118570
UC203H UC203x203x46 Dubai, United Arab Emirates TRADE LICENCE 597197

UC203E
UC254D

UC254D

UC254D UC254x254x89 Client


2A

UC
2D

UC
UC254E UC254x254x73
15

15
15

MDLBEAST

15
UC

2D
UC

UC305E UC305x305x137

2A

UC203E
UC305F UC305x305x118
UC305G UC305x305x97
UC356U UC356x368x177
UC

2A
UC

2D
VB1 70 DIA BAR OR MACALLOY
15

15
15

15
2A

460 M76 (OR EQUIVALENT)

UC
2D

UC
VB2 80 DIA BAR OR MACALLOY Project

UC152C UC152B UC152B UC152C 460 M76 (OR EQUIVALENT) SOUNDSTORM 2023
GROUND FLOOR LEVEL S1
+673485.000 (TBC) PF1 PF2 PF1 PF2
NOTES:
*FPS100x10 TO BE TACK WELDED
ON THE BOTTOM FLANGE OF Title
THE MAIN BEAMS
BIG BEAST STAGE ELEVATION
ALONG GRID 2

ELEVATION ALONG GRID 2 Date Drawn

SCALE 1 : 100 02/06/23 Jo.Na


Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:08 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14002 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

K J H G F E D C B A ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

2400 8200 2400 11200 3600 11200 2400 8200 2400


KEY PLAN

UPPER ROOF LEVEL UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E
6U UC

5E
35 35

UC
+709485.000 (TBC)

5E
UC152D
UC152D

UC152D

UC152D

UC152D
UC 6U

UC152D
UC152D

UC305E
2D
30

2D

30
D
UC152D
2D

15
2D

UC305E
UC152D
UC305E

UC152D

2D
UC
GENERAL NOTES

2
UC
UC

UC

UC
UC
UC

15
2D
15

15
UC
15
15

15
15

15
15

UC
UC

15
15
UC

UC
2D

5E
UC
5E

15
UC

UC
2D

2
2
20 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN

30
2D
2D
30

15
3D

D
2D
D
UPPER ROOF BOTTOM 3

UC

UC
20

UC

UC
D METERS UNLESS NOTED OTHERWISE.

6U
CHORD PLAN UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E UC

35
UC152C
UC152C
35

6U
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

UC
+706785.000 (TBC) UC152A UC152A
UC152E DIMENSIONS ARE TO BE FOLLOWED.
UC

UC203F
SIDE CLADDING: SKIN PVC ROLLER SIDE CLADDING: SKIN PVC ROLLER
UC152C 2A E 15

UC203F
OR SIMILAR, SPANNING BETWEEN UC152C
5 52 OR SIMILAR, SPANNING BETWEEN 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL

UC
1 2A

6U

UC203F
UC UC SECONDARY RAILS/GUIDES 1 SECONDARY RAILS/GUIDES OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
UC

UC203H

35
UC203H
D

35
20 03 SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

6U

UC
UC203F
UC
3D 2

6U
C

UC152C
M9307-RBG-PS007-ZZ-DR-ST-0003.

35
U

UC152C
35
UC UC

6U
UC203F
2A

UC
15 15 5 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
2A 2E 1
UC SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
UC152C UC152C PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
UC152A UC152E

UC
UC152A MEMBER

6U
UC FULLY WELDED AT CONNECTION POINTS.

35
35
20 1 VB B1 VB UC 3D

UC203F
B ....... BEAM

6U
2A

UC
20

UC
3D VB 1 E V 1
6U

5 2 15 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
UC152C

UC

35
C1 15 SC ....... STEEL COLUMN

UC152C
UC203F
2A
35

ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.


UC

6U
U

UC203H
UC

UC203F
VB ....... VERT CROSS BRACE

UC203H
UC203F
HB ....... HORIZ. CROSS BRACE 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
UC152C UC UC UC152C
A

UC203F

UC
UC 15 2 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
6U

15
2A 15

UC3
56U

35
20 2E
35

TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
3D UC 3D

6U
20
UC

STEEL COLUMN SCHEDULE LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC3

56U
UC152A UC152E UC152A UC
UC305F UC305F MARK SIZE
LOWER ROOF LEVEL UC356U UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC305F UC305F UC305F UC356U a UC152x152x51

UC152E
UC152E
UC

UC
+697385.000 (TBC)
UC

UC

UC152E
c UC152x152x23

UC152E

UC152E
UC254E

UC305F
UC254E

UC254E
UC356U
2

2E
UC152E

UC305F
UC152E
15
UC254E

UC152E
UC152E

UC254E
UC356U

15
25

UC305F
15

UC152E
UC356U

UC305F
UC254E
15
2E

4D
2E
d UC203x203x86
4E

15

2E

2A

4E

UC356U
4D

2A

2E

4E

UC
UC

UC

E
UC

15

UC
4E

15

25
UC

UC
25

UC

UC
UC

2
UC

25
UC

e UC203x203x71

2A
2E

15

25

25
15
UC

15
20

UC
25

15

UC
UC

15

15
15

25

UC
15
2A

15

15
4D

UC

UC
20

4E
UC
f UC203x203x60

2E
3H
UC

2E
2

UC

2E

4E
UC
15

2E
25

3H

E
LOWER ROOF BOTTOM PLAN g UC203x203x46
UC
UC

UC356U UC305F UC305F UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC305F UC305F UC305F UC356U j UC254x254x89
+694685.000 (TBC)
k UC254x254x73
LEVEL 4
UC152E UC152E
m UC305x305x137
2D

UC
+694085.000 (TBC) THE GAPS BETWEEN STRUCTURAL n UC305x305x118
15

15
7N

MEMBERS/SEGMENTS INDICATE
UC

p UC305x305x97

2D
45

LOCATION OF CONNECTIONS q UC356x368x177


UB

MEP LEVEL 3 (REFER TO DRAWING UC152E r UC152x152x30


+691620.000 (TBC) M9307-RBG-PS007-ZZ-DR-ST-12001)

7N
UC

7N
UB

45
15

45
45

2D
UC356U

UB
2D

UB
7N
UC356U

15
UC
UC152E UC152E STEEL FRAMING SCHEDULE
MARK SIZE

UC

UC356U
UC356U

15
2D

CHS244F UKCHS244.5x10

2D
15

FIS_248A FABRICATED BEAM (REFER TO


7N
UC

TABLES FOR DIMENSIONS)


45
UB

VIB LEVEL 2 UC152E UC152E FIS_248B FABRICATED BEAM (REFER TO


TABLES FOR DIMENSIONS)
+686697.500 (TBC)

7N
UC

A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


UB

FPS100x10 FPS100x10

7N
45
15

45

45

2D
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

UB
UB178A UB178x102x19
2D

7N

UB

15
UB254C UB254x146x31 Rev Revision Description By App Date

UC
SCALE 1 2 3 4 5 6 7 8
UC152E UC152E UB356D UB356x171x45 Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
UB457F UB457x191x82 You are responsible for verifying that any information or data supplied or transferred by electronic means
UC152D UC152D UB457N UB457x152x52 matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UC152A UC152x152x51

UC
damage however caused which you or any other party may directly or indirectly suffer in connection

15
2D

with your access to or use of that information or data.


UC152B UC152x152x44

2D
15

RBG provides this information for the express purpose contemplated by the underlying
7N

UC152C UC152x152x37
UC

terms of engagement for the project which must not be used for any other purpose. The
45

information is not a contractual document. Unless otherwise agreed in writing by RBG,


UC152D UC152x152x30
UB

all intellectual property rights in any information supplied by RBG are owned by, or
VIB LEVEL 1 UC152D UC152D licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UC152E UC152x152x23 licence to use the intellectual property rights for the express purpose.

+681172.500 (TBC) UC203D UC203x203x86

7N

7N
UC

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


UB

45

45
UC356U
15

UC203E UC203x203x71 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE


45

2D
UB

UB
2D

7N

15
UC203F UC203x203x60 Structural, Civil & Construction

UC356U

UC356U
UC
UC203G UC203x203x52 Engineering Consultant
UC152D UC203H UC203x203x46
UC254D UC254x254x89 Robert BirdGroup

UC
UC356U

UC254E UC254x254x73

15
2D

Member of the Surbana Jurong Group

2D
15

UC305E UC305x305x137
UC

DUBAI OFFICE
UC305F UC305x305x118 Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
UC305G UC305x305x97 Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
UC356U UC356x368x177 Jebel Ali, Dubai
UC

PO Box 118570
VB1 70 DIA BAR OR MACALLOY
15

Dubai, United Arab Emirates

2D
TRADE LICENCE 597197
460 M76 (OR EQUIVALENT)
2D

15
VB2 80 DIA BAR OR MACALLOY Client

UC
460 M76 (OR EQUIVALENT) MDLBEAST
UC152D UC152D
GROUND FLOOR LEVEL
+673485.000 (TBC) PF5 PF5
NOTES:
*FPS100x10 TO BE TACK WELDED
ON THE BOTTOM FLANGE OF Project
THE MAIN BEAMS
SOUNDSTORM 2023

ELEVATION ALONG GRID 4


SCALE 1 : 100
Title

BIG BEAST STAGE ELEVATION


ALONG GRID 4

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:11 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14003 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

A B C D E F G H J K ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

2400 8200 2400 11200 3600 11200 2400 8200 2400


KEY PLAN

UPPER ROOF LEVEL UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E UC
6U 35
35

UC
+709485.000 (TBC)

UC
6U
UC

UC305E
30
GENERAL NOTES

15

5E
UC152D
UC305E

UC305E
2D
UC152D
UC152D

UC152D
UC152D

2D
UC
UC

UC

UC

UC
UC
2D

2D
D
5E

30
2D

UC305E
UC152D

UC152D

UC152D

UC152D

UC152D
15

15
2
15
15

15

D
15

15
15

UC
15

15
15

2
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN

UC
2

UC
UC

2D

2D

15
6U

2D

2D
2D
UC

UC
UC
D

UC
5E
D

D
UPPER ROOF BOTTOM 20 03
METERS UNLESS NOTED OTHERWISE.

35

UC
15
30

30
3

UC
2

UC
CHORD PLAN D
UC UC152C

UC
UC

5E

35
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

6U
+706785.000 (TBC) UC152C UC305E UC305F UC305F UC305F UC305F UC305F UC305F UC305F UC305E

6U
DIMENSIONS ARE TO BE FOLLOWED.

35

UC152C
UC152A UC152E UC152A

UC152C
UC
UC SIDE CLADDING: SKIN PVC ROLLER SIDE CLADDING: SKIN PVC ROLLER 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
2E

6U
2A

UC
15 OR SIMILAR, SPANNING BETWEEN OR SIMILAR, SPANNING BETWEEN OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
15 15

UC203F
UC

35
6U

UC203F
UC203H
2A

35
D SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

UC203F
SECONDARY RAILS/GUIDES
UC UC

UC203F
20 SECONDARY RAILS/GUIDES
03

UC
35

6U
UC203H

UC
3 2 M9307-RBG-PS007-ZZ-DR-ST-0003.

UC
D UC UC UC152C

35
UC
A 15

6U
15 MEMBER
6U UC152C 52 2E 2A 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
C1 SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
35

UC152C
U B ....... BEAM
UC152C
UC

PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE


UC152E UC152A SC ....... STEEL COLUMN

6U

UC
UC152A FULLY WELDED AT CONNECTION POINTS.
UC VB ....... VERT CROSS BRACE

35
6U

35
20 UC 1 VB B1 VB D
E A 03
UC
VB
35

6U
15 1 2 V 1 2 HB ....... HORIZ. CROSS BRACE 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

UC
3 15 15 2
UC

D 2A
UC UC UC UC152C ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

35
UC203F

UC203H

UC203F
UC203H

6U
UC152C

UC203F
6U

UC203F
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
35

UC152C
UC152C

UC
UC

UC
A 15 15 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
6U

UC
52 2E 2A
C1 TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
35

35
56U

UC D STEEL COLUMN SCHEDULE

UC3
U 03
UC

LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).

6U
20 2
3 C
UC3

D UC152A UC152E UC152A U

56U
MARK SIZE
LOWER ROOF LEVEL UC356U UC305F UC305F UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC305F UC305F UC305F UC356U a UC152x152x51
c UC152x152x23
+697385.000 (TBC)
UC
UC

UC
UC

UC
2E
d UC203x203x86

E
2E
15
25

UC305F

UC305F

UC305F

UC305F

25
UC254E

UC254E

UC254E

UC152E

UC152E

UC152E
UC152E

UC152E
UC152E

UC152E

UC152E

UC152E

UC254E

UC254E

UC254E
UC356U

UC356U

UC356U

UC356U
15

4E
15
4E

2
UC

UC
UC

UC

UC

UC

UC

UC

UC

UC
4E
4E

2E

15
UC152E

15
2A

2E
4D

15

4D
2E

2A
e UC203x203x71

25
25

15
15

15

25
25
25

25

15

15

15

15

25

25
15

UC
UC
15

UC

UC
UC
UC

f UC203x203x60

UC
4E

4E

UC

2E

2E

2E

2E

4E

4E
UC
UC

2A

4D
4D

2E
2A

E
g UC203x203x46

15

15

25
25

15

LOWER ROOF BOTTOM PLAN

UC

UC

UC
UC

UC

j UC254x254x89
+694685.000 (TBC) UC356U UC305F UC305F UC305F UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC254E UC305F UC305F UC305F UC305F UC305F UC356U k UC254x254x73
UC152E UC152E m UC305x305x137
THE GAPS BETWEEN STRUCTURAL
LEVEL 4 n UC305x305x118
UC

2D
MEMBERS/SEGMENTS INDICATE

15
15

+694085.000 (TBC) LOCATION OF CONNECTIONS p UC305x305x97

UC
2D

(REFER TO DRAWING q UC356x368x177


M9307-RBG-PS007-ZZ-DR-ST-12001) r UC152x152x30
MEP LEVEL 3 UC152E UC152E
+691620.000 (TBC)
2D

UC
15

15
STEEL FRAMING SCHEDULE
UC

2D
MARK SIZE
UC152E UC152E CHS244F UKCHS244.5x10

UC356U
FIS_248A FABRICATED BEAM (REFER TO
UC356U

UC356U

UC356U

2D
UC

TABLES FOR DIMENSIONS)

15
15

FIS_248B FABRICATED BEAM (REFER TO

UC
2D

TABLES FOR DIMENSIONS)


VIB LEVEL 2 UC152E UC152E FPS100x10 FPS100x10
+686697.500 (TBC) UB178A UB178x102x19 A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23

UC
2D

UB254C UB254x146x31 A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23


15

15
UB356D UB356x171x45 Rev Revision Description By App Date
UC

2D
UB457F UB457x191x82 SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
UC152E UC152E UB457N UB457x152x52 accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
UC152D UC152A UC152x152x51 matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
UC152D liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
UC152B UC152x152x44 or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
UC152C UC152x152x37 with your access to or use of that information or data.
UC

2D
UC152D UC152x152x30 RBG provides this information for the express purpose contemplated by the underlying
15

15
terms of engagement for the project which must not be used for any other purpose. The
2D

UC
UC152E UC152x152x23 information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
UC203D UC203x203x86 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
VIB LEVEL 1 UC152D UC152D licence to use the intellectual property rights for the express purpose.
UC203E UC203x203x71
+681172.500 (TBC) DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC203F UC203x203x60
UC356U

UC356U

UC
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC203G UC203x203x52
2D

15
Structural, Civil & Construction
15

2D
UC203H UC203x203x46 Engineering Consultant
UC

UC254D UC254x254x89
UC152D UC152D UC254E
UC305E
UC254x254x73
UC305x305x137
Robert BirdGroup

UC356U
Member of the Surbana Jurong Group
UC

2D
UC305F UC305x305x118

15
15

UC305G UC305x305x97 DUBAI OFFICE

UC
2D

UC356U
Robert Bird Group Pty Ltd
UC356U UC356x368x177 Ibn Battuta Gate
Ph:
Email:
+971 (0) 4 447 1866
MENA@robertbird.com.au
VB1 70 DIA BAR OR MACALLOY Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
460 M76 (OR EQUIVALENT) PO Box 118570

UC
VB2 80 DIA BAR OR MACALLOY Dubai, United Arab Emirates TRADE LICENCE 597197
2D

15
460 M76 (OR EQUIVALENT)
15

Client

2D
UC

UC152D
MDLBEAST
UC152D
GROUND FLOOR LEVEL
+673485.000 (TBC) NOTES:
PF1 S1 PF1 *FPS100x10 TO BE TACK WELDED
ON THE BOTTOM FLANGE OF
THE MAIN BEAMS
Project

SOUNDSTORM 2023

ELEVATION ALONG GRID 5


SCALE 1 : 100

Title

BIG BEAST STAGE ELEVATION


ALONG GRID 5

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:15 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14004 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

GENERAL NOTES
K J H G F E D C B A
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.

2400 8200 2400 11200 3600 11200 2400 8200 2400 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
DIMENSIONS ARE TO BE FOLLOWED.
UPPER ROOF LEVEL 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
+709485.000 (TBC) OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
M9307-RBG-PS007-ZZ-DR-ST-0003.

UPPER ROOF BOTTOM 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER


CHORD PLAN SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
+706785.000 (TBC) FULLY WELDED AT CONNECTION POINTS.

5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES


MEMBER
B ....... BEAM 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
SC ....... STEEL COLUMN TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE

THE GAPS BETWEEN STRUCTURAL STEEL COLUMN SCHEDULE


MEMBERS/SEGMENTS INDICATE
LOCATION OF CONNECTIONS MARK SIZE
(REFER TO DRAWING
a UC152x152x51
M9307-RBG-PS007-ZZ-DR-ST-12001)
c UC152x152x23
d UC203x203x86
LOWER ROOF LEVEL e UC203x203x71
UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E
f UC203x203x60

UC
+697385.000 (TBC)

UC
UC

UC203H

UC203H

UC203H
UC254E

g UC203x203x46

UC203H
UC203H
UC203H
UC203H
20
3H

25
25

UC203H

UC203H
UC203H

UC UC254E
3H

UC254E
UC
UC254E

j UC254x254x89

3H

UC

4E
4E

3H

20

3H

UC
UC
UC

UC
20

3H
20

3H

20
UC
k UC254x254x73
20

20

20
20
UC
20

20

20
3

20

3H
3H

4E
UC
4E

UC

3
3H
m UC305x305x137
3H

3H

UC

UC

25
25

20
LOWER ROOF BOTTOM PLAN n UC305x305x118
UC

UC
+694685.000 (TBC) UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E p UC305x305x97
q UC356x368x177
LEVEL 4 r UC152x152x30
+694085.000 (TBC)

MEP LEVEL 3 STEEL FRAMING SCHEDULE


+691620.000 (TBC)
MARK SIZE
CHS244F UKCHS244.5x10 A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
FIS_248A FABRICATED BEAM (REFER TO A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
TABLES FOR DIMENSIONS)
Rev Revision Description By App Date
FIS_248B FABRICATED BEAM (REFER TO SCALE 1 2 3 4 5 6 7 8
TABLES FOR DIMENSIONS) Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
FPS100x10 FPS100x10 You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
UB178A UB178x102x19 liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UB254C UB254x146x31 damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
VIB LEVEL 2 UB356D UB356x171x45
RBG provides this information for the express purpose contemplated by the underlying
+686697.500 (TBC) UB457F UB457x191x82 terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
UB457N UB457x152x52 all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UC152A UC152x152x51 licence to use the intellectual property rights for the express purpose.

UC152B UC152x152x44 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


UC152C UC152x152x37 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC152D UC152x152x30 Structural, Civil & Construction
Engineering Consultant
UC152E UC152x152x23
UC203D UC203x203x86
UC203E
UC203F
UC203x203x71
UC203x203x60
Robert BirdGroup
Member of the Surbana Jurong Group
UC203G UC203x203x52
VIB LEVEL 1 DUBAI OFFICE
UC203H UC203x203x46 Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
+681172.500 (TBC) UC254D UC254x254x89 Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
UC254E UC254x254x73 Jebel Ali, Dubai
PO Box 118570
UC305E UC305x305x137 Dubai, United Arab Emirates TRADE LICENCE 597197
UC305F UC305x305x118
Client
UC305G UC305x305x97
UC356U UC356x368x177 MDLBEAST
VB1 70 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT)
VB2 80 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT)

PLAN AT GROUND LEVEL Project


MEMBER
+674958.485 (TBC)
SOUNDSTORM 2023
NOTES:
*FPS100x10 TO BE TACK WELDED
ON THE BOTTOM FLANGE OF
GROUND FLOOR LEVEL THE MAIN BEAMS
+673485.000 (TBC)
Title

BIG BEAST STAGE ELEVATION


ALONG GRID 6

ELEVATION ALONG GRID 6


SCALE 1 : 100 Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:18 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14005 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

A B C D E F G H J K GENERAL NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.
2400 8200 2400 11200 3600 11200 2400 8200 2400 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
DIMENSIONS ARE TO BE FOLLOWED.
UPPER ROOF LEVEL
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
+709485.000 (TBC) OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
M9307-RBG-PS007-ZZ-DR-ST-0003.

UPPER ROOF BOTTOM 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER


CHORD PLAN SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
+706785.000 (TBC)
FULLY WELDED AT CONNECTION POINTS.

5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES


MEMBER
B ....... BEAM 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
SC ....... STEEL COLUMN LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE

THE GAPS BETWEEN STRUCTURAL


MEMBERS/SEGMENTS INDICATE
LOCATION OF CONNECTIONS
(REFER TO DRAWING STEEL COLUMN SCHEDULE
M9307-RBG-PS007-ZZ-DR-ST-12001)
MARK SIZE
a UC152x152x51
c UC152x152x23
LOWER ROOF LEVEL UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E
d UC203x203x86

4E
+697385.000 (TBC)

UC
UC

e UC203x203x71

3H

3H

25
20
UC254E
25

UC

UC254E
UC

UC
UC203H

UC203H
UC203H

UC203H
UC254E

UC254E
3H

UC
f UC203x203x60

20

UC203H
20
3H
3H
4E

UC203H
UC203H

UC203H
3H
UC

UC203H

UC203H

20
3H

20

20
UC

20
UC

UC

UC
g UC203x203x46

20

20

3H
20

20

3H

UC
20
20

3H

UC
UC

H
UC
4E

j UC254x254x89
3H

UC
3H
3

20

25
25

H
LOWER ROOF BOTTOM PLAN k UC254x254x73

UC

4E
UC

UC254E UC254D UC254D UC254D UC254D UC254D UC254D UC254D UC254E m UC305x305x137
+694685.000 (TBC)
n UC305x305x118
LEVEL 4 p UC305x305x97
+694085.000 (TBC) q UC356x368x177
r UC152x152x30
MEP LEVEL 3
+691620.000 (TBC)

STEEL FRAMING SCHEDULE


A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
MARK SIZE A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
CHS244F UKCHS244.5x10 Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
FIS_248A FABRICATED BEAM (REFER TO
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
TABLES FOR DIMENSIONS) accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
You are responsible for verifying that any information or data supplied or transferred by electronic means
FIS_248B FABRICATED BEAM (REFER TO matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
TABLES FOR DIMENSIONS) liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
VIB LEVEL 2 FPS100x10 FPS100x10 damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
UB178A UB178x102x19 RBG provides this information for the express purpose contemplated by the underlying
+686697.500 (TBC) terms of engagement for the project which must not be used for any other purpose. The
UB254C UB254x146x31 information is not a contractual document. Unless otherwise agreed in writing by RBG,
all intellectual property rights in any information supplied by RBG are owned by, or
UB356D UB356x171x45 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.
UB457F UB457x191x82
UB457N UB457x152x52 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
UC152A UC152x152x51 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC152B UC152x152x44 Structural, Civil & Construction
Engineering Consultant
UC152C UC152x152x37
UC152D
UC152E
UC152x152x30
UC152x152x23 Robert BirdGroup
UC203D UC203x203x86 Member of the Surbana Jurong Group
VIB LEVEL 1 UC203E UC203x203x71 DUBAI OFFICE
+681172.500 (TBC) UC203F UC203x203x60 Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
Ibn Battuta Gate Email: MENA@robertbird.com.au
UC203G UC203x203x52 Level 4, Office Suite 415 Web: www.robertbird.com
Jebel Ali, Dubai
UC203H UC203x203x46 PO Box 118570
UC254D UC254x254x89 Dubai, United Arab Emirates TRADE LICENCE 597197

UC254E UC254x254x73 Client


UC305E UC305x305x137
UC305F UC305x305x118
MDLBEAST
UC305G UC305x305x97
UC356U UC356x368x177
VB1 70 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT)
PLAN AT GROUND LEVEL VB2 80 DIA BAR OR MACALLOY
MEMBER 460 M76 (OR EQUIVALENT) Project

+674958.485 (TBC) SOUNDSTORM 2023

NOTES:
GROUND FLOOR LEVEL
*FPS100x10 TO BE TACK WELDED
+673485.000 (TBC) ON THE BOTTOM FLANGE OF
THE MAIN BEAMS Title

BIG BEAST STAGE ELEVATION


ALONG GRID 7
ELEVATION ALONG GRID 7
SCALE 1 : 100

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:21 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14006 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

GENERAL NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.

1 2 3 4 5 6 7 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN


DIMENSIONS ARE TO BE FOLLOWED.

2400 8900 9500 2400 12000 2700 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
M9307-RBG-PS007-ZZ-DR-ST-0003.
UPPER ROOF LEVEL
+709485.000 (TBC) 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.
UPPER ROOF BOTTOM 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
CHORD PLAN ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
+706785.000 (TBC)
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE


MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
B ....... BEAM
SC ....... STEEL COLUMN
VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE

THE GAPS BETWEEN STRUCTURAL


MEMBERS/SEGMENTS INDICATE STEEL COLUMN SCHEDULE
LOCATION OF CONNECTIONS
(REFER TO DRAWING MARK SIZE
M9307-RBG-PS007-ZZ-DR-ST-12001) a UC152x152x51
c UC152x152x23
d UC203x203x86
LOWER ROOF LEVEL UC203H UC203H UC203E UC203E UC203E UC203E UC356U UC356U e UC203x203x71
UC UC f UC203x203x60
UC

UC
+697385.000 (TBC) 20 UC UC 25
2A

UC152A

UC152A
4D g UC203x203x46
20

25
3H
UC203H

UC356U
UC152A

15 A 15

UC356U

UC356U
UC203H

UC203H

5 UC152A

UC152A
1 52
3H

4D
2A 2A
UC
j UC254x254x89
U C1
3H 4D
k UC254x254x73

4D
3H

20 5 m UC305x305x137

25
20

LOWER ROOF BOTTOM PLAN UC C2

UC
UC

U n UC305x305x118
+694685.000 (TBC) UC203H UC203H UC203E UC203E UC203E UC203E UC356U UC356U p UC305x305x97
UC152E UC152E q UC356x368x177
LEVEL 4
SIDE CLADDING: SKIN PVC ROLLER r UC152x152x30

2D
UC

+694085.000 (TBC) OR SIMILAR, SPANNING BETWEEN

15
15

SECONDARY RAILS/GUIDES

UC
2E

A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


MEP LEVEL 3 UC152E UC152E A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
+691620.000 (TBC) STEEL FRAMING SCHEDULE Rev Revision Description By App Date

UC
2E

SCALE 1 2 3 4 5 6 7 8
MARK SIZE

15
15

Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the

2D
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
UC

CHS244F UKCHS244.5x10 You are responsible for verifying that any information or data supplied or transferred by electronic means
UC203D

matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
FIS_248A FABRICATED BEAM (REFER TO
UC203D

UC152E UC152E TABLES FOR DIMENSIONS)


liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
FIS_248B FABRICATED BEAM (REFER TO with your access to or use of that information or data.

UC356U

UC356U
2D
TABLES FOR DIMENSIONS)
UC

RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The

15
15

FPS100x10 FPS100x10 information is not a contractual document. Unless otherwise agreed in writing by RBG,

UC
2E

all intellectual property rights in any information supplied by RBG are owned by, or
UB178A UB178x102x19 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.
VIB LEVEL 2 UC152E UC152E UB254C UB254x146x31
DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
+686697.500 (TBC) UB356D UB356x171x45
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UB457F UB457x191x82
2E

UC
Structural, Civil & Construction
15

15
UB457N UB457x152x52 Engineering Consultant
UC

2D
UC152A UC152x152x51
UC152E
UC152C
UC152E UC152B
UC152C
UC152x152x44
UC152x152x37
Robert BirdGroup
UC152D Member of the Surbana Jurong Group
2

UC152D UC152x152x30
VB

VB

DUBAI OFFICE
2

UC152E UC152x152x23
UC

2D UC203D UC203x203x86
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
15

15
Ibn Battuta Gate Email: MENA@robertbird.com.au
2D

UC

UC203E UC203x203x71 Level 4, Office Suite 415 Web: www.robertbird.com


Jebel Ali, Dubai
UC203F UC203x203x60 PO Box 118570
VIB LEVEL 1 UC152C UC152D Dubai, United Arab Emirates TRADE LICENCE 597197
UC203G UC203x203x52
+681172.500 (TBC)
UC356U

UC203H UC203x203x46 Client


UC356U
2D

UC

UC254D UC254x254x89 MDLBEAST


15

15
UC

UC254E UC254x254x73
2D

UC305E UC305x305x137
UC203E

UC152C UC152D
UC203E

UC305F UC305x305x118
UC305G UC305x305x97
2D
UC

UC356U UC356x368x177
15
15

VB1 70 DIA BAR OR MACALLOY


UC
2D

Project
460 M76 (OR EQUIVALENT)
VB2 80 DIA BAR OR MACALLOY SOUNDSTORM 2023
460 M76 (OR EQUIVALENT)
UC
2D
15

15
UC

2D

NOTES:
UC152C UC152D *FPS100x10 TO BE TACK WELDED Title
GROUND FLOOR LEVEL
ON THE BOTTOM FLANGE OF
+673485.000 (TBC) THE MAIN BEAMS BIG BEAST STAGE ELEVATION
PF1 ALONG GRID A

ELEVATION ALONG GRID A Date Drawn

SCALE 1 : 100 02/06/23 Jo.Na


Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:24 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14007 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

7 6 5 4 3 2 1
GENERAL NOTES
2700 12000 2400 9500 8900 2400 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.
UPPER ROOF LEVEL 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
+709485.000 (TBC) DIMENSIONS ARE TO BE FOLLOWED.

3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL


OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
UPPER ROOF BOTTOM
M9307-RBG-PS007-ZZ-DR-ST-0003.
CHORD PLAN
+706785.000 (TBC) 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.

5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE


MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
B ....... BEAM
SC ....... STEEL COLUMN
VB ....... VERT CROSS BRACE
THE GAPS BETWEEN STRUCTURAL
MEMBERS/SEGMENTS INDICATE HB ....... HORIZ. CROSS BRACE
LOCATION OF CONNECTIONS
(REFER TO DRAWING
M9307-RBG-PS007-ZZ-DR-ST-12001)

LOWER ROOF LEVEL STEEL COLUMN SCHEDULE


UC356U UC356U UC203E UC203E UC203E UC203E UC203H UC203H
UC UC
+697385.000 (TBC)

UC
UC
25 UC 20 MARK SIZE

UC152A
UC

UC152A

UC203H
UC152A

UC203H
4D 3H

20
25
2A 15

UC203H
UC356U
A

UC152A
UC356U
UC356U

UC152A
15 a UC152x152x51
5 2A 52

3H
4D
2A 1 1
UC UC
c UC152x152x23
4D 3H

4D
d UC203x203x86

3H
0
25 2

25

20
e UC203x203x71
LOWER ROOF BOTTOM PLAN
UC UC

UC

UC
f UC203x203x60
+694685.000 (TBC) UC356U UC356U UC203E UC203E UC203E UC203E UC203H UC203H
g UC203x203x46
UC152E UC152E j UC254x254x89
LEVEL 4

UC
k UC254x254x73

2D

15
15
+694085.000 (TBC) m UC305x305x137

2E
UC
n UC305x305x118
MEP LEVEL 3 UC152E UC152E p UC305x305x97
+691620.000 (TBC) q UC356x368x177
UC

7F

2E
r UC152x152x30

45
15

15
UB
2D

UC
UC152E UC152E A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
STEEL FRAMING SCHEDULE
UC356U
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23

UC
UC203D
UC356U

UC203D
2D

Rev Revision Description By App Date

15
MARK SIZE
15

2E
SCALE 1 2 3 4 5 6 7 8
CHS244F UKCHS244.5x10
UC

Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
FIS_248A FABRICATED BEAM (REFER TO You are responsible for verifying that any information or data supplied or transferred by electronic means
VIB LEVEL 2 UC152E UC152E TABLES FOR DIMENSIONS) matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
+686697.500 (TBC) FIS_248B FABRICATED BEAM (REFER TO or data supplied or transferred by electronic means and you release RBG from any liability for any loss or

7F
UC

damage however caused which you or any other party may directly or indirectly suffer in connection

2E
TABLES FOR DIMENSIONS)

45
with your access to or use of that information or data.
15

15
UB
RBG provides this information for the express purpose contemplated by the underlying
FPS100x10 FPS100x10
2D

UC
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
UB178A UB178x102x19 all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UC152E UC152E UB254C UB254x146x31 licence to use the intellectual property rights for the express purpose.
UB356D UB356x171x45
UC152D UC152C DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS

2
UB457F UB457x191x82

VB
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE

VB

UC
UB457N UB457x152x52
2D

Structural, Civil & Construction

15
15

UC152A UC152x152x51 Engineering Consultant

2D
UC

UC152B UC152x152x44
VIB LEVEL 1 UC152D UC152C
UC152C
UC152D
UC152x152x37
UC152x152x30
Robert BirdGroup
+681172.500 (TBC) Member of the Surbana Jurong Group
UC152E UC152x152x23

7F
UC356U

2D

UC203E
UC356U
UC

45
DUBAI OFFICE
UC203D UC203x203x86

15
15

UB
Robert Bird Group Pty Ltd

UC
Ph: +971 (0) 4 447 1866
2D

UC203E UC203x203x71 Ibn Battuta Gate Email: MENA@robertbird.com.au


Level 4, Office Suite 415 Web: www.robertbird.com
UC203F UC203x203x60 Jebel Ali, Dubai
UC152D UC152C UC203G UC203x203x52 PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
UC203H UC203x203x46

UC203E
UC
2D

Client

15
UC254D UC254x254x89
15

2D
MDLBEAST
UC

UC254E UC254x254x73
UC305E UC305x305x137
UC305F UC305x305x118
UC305G UC305x305x97
UC

2D
15

UC356U UC356x368x177

15
2D

UC
VB1 70 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT) Project
UC152D UC152C VB2 80 DIA BAR OR MACALLOY
GROUND FLOOR LEVEL 460 M76 (OR EQUIVALENT) SOUNDSTORM 2023
+673485.000 (TBC)
PF1

NOTES:
*FPS100x10 TO BE TACK WELDED Title
ON THE BOTTOM FLANGE OF
THE MAIN BEAMS BIG BEAST STAGE ELEVATION
ELEVATION ALONG GRID B
SCALE 1 : 100 ALONG GRID B

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:27 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14008 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

1 2 3 4 5 6 7
KEY PLAN

2400 8900 9500 2400 12000 2700

GENERAL NOTES
UPPER ROOF LEVEL UC203F UC203F UC254E UC254E UC254E UC254E UC305E UC305E
UC UC 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN

5E
+709485.000 (TBC)

UC
20 E UC E UC 30 METERS UNLESS NOTED OTHERWISE.
54

30
54 25 5E

UC254E
3F

20
UC203F

UC203F

UC254E

UC254E

UC254E

UC305E
UC305E
25

UC203F

UC305E
2 2

UC
4E

3F
4E C
UC

UC254E
U
3F 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN

3F
20 E

20
DIMENSIONS ARE TO BE FOLLOWED.

UC
UPPER ROOF BOTTOM
UC 05

UC
3

30
CHORD PLAN UC203F UC

5E
3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
+706785.000 (TBC) UC203F UC203F UC254E UC254E UC254E UC254E UC305E UC305E OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
UC SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
SIDE CLADDING: SKIN PVC ROLLER UC152A M9307-RBG-PS007-ZZ-DR-ST-0003.
15 OR SIMILAR, SPANNING BETWEEN A
2E 52
SECONDARY RAILS/GUIDES 1 4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
UC

UC203G

UC203F
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE

UC203G

UC203F
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
E UC FULLY WELDED AT CONNECTION POINTS.
2 15
15 2A
UC 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
UC152E UC152A

CH
UC 6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

S2
15 2 A

44
2E 15

F
UC 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

UC203F
UC203G

UC203G MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

UC203F
THE GAPS BETWEEN STRUCTURAL LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
B ....... BEAM
2E UC MEMBERS/SEGMENTS INDICATE
15 SC ....... STEEL COLUMN
15 2A
LOCATION OF CONNECTIONS
UC (REFER TO DRAWING VB ....... VERT CROSS BRACE
M9307-RBG-PS007-ZZ-DR-ST-12001) HB ....... HORIZ. CROSS BRACE
UC152E UC152A
LOWER ROOF LEVEL UC254D UC254D UC305G UC305G UC305G UC305G UC305F UC305F UC254D UC254D UC254D UC254D UC254D
UC UC
UC

+697385.000 (TBC) UC

UC
25 UC 15 UC
2A

UC254E
UC203E
UC 20
25

4E

UC
4D

UC254E
15
UC254D
2A
UC254D

UC254D

UC254D
20 20
UC254D

E
UC254D

UC254D
15

UC305F
3E

UC203E

UC203E

UC203E

UC254E
UC305F
UC254D
03 20 3E 3E

25
4D

25
2A
3E 0 3E
C2 3E 20 UC STEEL COLUMN SCHEDULE

UC305F
C2

UC

4E
4D

4D
U UC U
25

2A
5 MARK SIZE
2
UC

15
LOWER ROOF BOTTOM PLAN UC254D UC a UC152x152x51

UC
+694685.000 (TBC) UC254D UC305G UC305G UC305G UC305G UC305F UC305F UC254D UC254D UC254D UC254D UC254D c UC152x152x23
UC152D d UC203x203x86
LEVEL 4 e UC203x203x71
UC

f UC203x203x60
+694085.000 (TBC)
15

7F g UC203x203x46
2D

45
UB

MEP LEVEL 3 j UC254x254x89


UC152D
k UC254x254x73
+691620.000 (TBC)
m UC305x305x137
UC254D

2D

UC254D

n UC305x305x118
15
UC

p UC305x305x97
UC305G

q UC356x368x177
UC152D r UC152x152x30
UC
15
2D

7F

7F

A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23


45

45

STEEL FRAMING SCHEDULE


UB

A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23


UB

VIB LEVEL 2 UC152D Rev Revision Description By App Date


+686697.500 (TBC) MARK SIZE SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
2D

CHS244F UKCHS244.5x10 accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
15

You are responsible for verifying that any information or data supplied or transferred by electronic means
FIS_248A FABRICATED BEAM (REFER TO
UC

matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
TABLES FOR DIMENSIONS) liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
UC305G

FIS_248B FABRICATED BEAM (REFER TO damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
TABLES FOR DIMENSIONS) RBG provides this information for the express purpose contemplated by the underlying
UC152B FPS100x10 FPS100x10 terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
UB178A UB178x102x19 all intellectual property rights in any information supplied by RBG are owned by, or
UC

licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UB254C UB254x146x31
15

licence to use the intellectual property rights for the express purpose.
7F
2A

UB356D UB356x171x45
7F

DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


45

45

REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE


UB

UB457F UB457x191x82
UB

VIB LEVEL 1 UC152B UB457N UB457x152x52 Structural, Civil & Construction


Engineering Consultant
+681172.500 (TBC) UC152A UC152x152x51
2A
UC254D

UC152B UC152x152x44
Robert BirdGroup
UC254D
15

UC152C UC152x152x37
UC

UC152D UC152x152x30 Member of the Surbana Jurong Group


UC152B UC152E UC152x152x23 DUBAI OFFICE
UC203D UC203x203x86 Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
UC305G

Ibn Battuta Gate


UC203E UC203x203x71 Level 4, Office Suite 415
Email:
Web:
MENA@robertbird.com.au
www.robertbird.com
UC

UC203F UC203x203x60 Jebel Ali, Dubai


15

PO Box 118570
2A

UC203G UC203x203x52 Dubai, United Arab Emirates TRADE LICENCE 597197

UC203H UC203x203x46
Client
UC254D UC254x254x89
MDLBEAST
2A

UC254E UC254x254x73
15

UC305E UC305x305x137
UC

UC305F UC305x305x118
UC152B UC305G UC305x305x97
GROUND FLOOR LEVEL UC356U UC356x368x177
+673485.000 (TBC) VB1 70 DIA BAR OR MACALLOY
PF2 PF1 PF5 460 M76 (OR EQUIVALENT) Project
PF1
VB2 80 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT)
SOUNDSTORM 2023

NOTES:
*FPS100x10 TO BE TACK WELDED Title
ON THE BOTTOM FLANGE OF
THE MAIN BEAMS BIG BEAST STAGE ELEVATION
ELEVATION ALONG GRID C AND GRID H (MIRRORED) ALONG GRID C
SCALE 1 : 100

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:30 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14009 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

KEY PLAN

7 6 5 4 3 2 1 GENERAL NOTES
1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
2700 12000 2400 9500 8900 2400 METERS UNLESS NOTED OTHERWISE.

2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN


DIMENSIONS ARE TO BE FOLLOWED.
UPPER ROOF LEVEL UC305E UC305E UC254E UC254E UC254E UC254E UC203F UC203F
UC UC 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
+709485.000 (TBC) UC

UC

UC
30 UC 20 OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
25 4E

UC305E

UC305E
5E 3F

30

20
E

UC203F

UC203F

UC203F
UC305E

UC254E

UC254E

UC254E

UC254E

UC254E
4E 54 25 5 SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

5E

3F
C 2 4E
U C2 M9307-RBG-PS007-ZZ-DR-ST-0003.

3F
U
E 3F

20
5E
UPPER ROOF BOTTOM 05 0

UC
3 C2

30
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER
CHORD PLAN UC U UC203F

UC
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
+706785.000 (TBC) UC305E UC305E UC254E UC254E UC254E UC254E UC203F PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
UC152A FULLY WELDED AT CONNECTION POINTS.
UC203F
UC 5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
5 2A 15
2E ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

UC203G
C1

UC203F
U
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
UC E
52

UC203F

UC152E
15 1

4F
2A UC 7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE

4
S2
MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

CH
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
UC152A B ....... BEAM
V B1 SC ....... STEEL COLUMN
UC
2 A V B1 15 VB ....... VERT CROSS BRACE
15 2E
UC HB ....... HORIZ. CROSS BRACE

UC203G
UC203F
UC
2E

UC203F

UC152E
15 5
2A
U C1
STEEL COLUMN SCHEDULE
UC152A UC152E
MARK SIZE
LOWER ROOF LEVEL UC254D UC254D UC254D UC254D UC254D UC305F UC305F UC305G UC305G UC305G UC305G UC254D UC254D a UC152x152x51
+697385.000 (TBC) UC 4D

UC

UC
UC UC c UC152x152x23
15 UC 5 THE GAPS BETWEEN STRUCTURAL
UC254E

E C2

15

25
UC254D

UC254D
UC254D

UC254D
20 03 20 2A

UC UC305F

UC305F

UC305F
UC254D

UC254D

UC254D

UC254D
UC254E

UC254E

UC203E

UC203E

UC203E

UC203E
20 d UC203x203x86
4E

U MEMBERS/SEGMENTS INDICATE

2A

4D
3E 2 3E UC 3E
25
UC

UC A 20 E LOCATION OF CONNECTIONS e UC203x203x71

4D
52 03
UC

3E
25

3E (REFER TO DRAWING
1 2 4D

25
0 f UC203x203x60

2A
4E

UC C2 UC 5 M9307-RBG-PS007-ZZ-DR-ST-12001)

UC
C2

15
LOWER ROOF BOTTOM PLAN U g UC203x203x46
U j UC254x254x89
+694685.000 (TBC) UC254D UC254D UC254D UC254D UC254D UC305F UC305F UC305G UC305G UC305G UC305G UC254D UC254D
k UC254x254x73
LEVEL 4 UB178A UC152D m UC305x305x137

UC305G

UC
n UC305x305x118
+694085.000 (TBC)

15
p UC305x305x97

2D
q UC356x368x177
MEP LEVEL 3 UB457N UB457N UC254E UC152D r UC152x152x30
+691620.000 (TBC)

2D
UC254D

UC254D
15
UC
A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
STEEL FRAMING SCHEDULE A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
UC152D
MARK SIZE Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
CHS244F UKCHS244.5x10

UC
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
FIS_248A FABRICATED BEAM (REFER TO accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

15
You are responsible for verifying that any information or data supplied or transferred by electronic means
TABLES FOR DIMENSIONS)

2D
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
FIS_248B FABRICATED BEAM (REFER TO or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
VIB LEVEL 2 UB457N UB457N UB356D UC152D TABLES FOR DIMENSIONS) damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
+686697.500 (TBC) FPS100x10 FPS100x10 RBG provides this information for the express purpose contemplated by the underlying

2D
terms of engagement for the project which must not be used for any other purpose. The
UB178A UB178x102x19 information is not a contractual document. Unless otherwise agreed in writing by RBG,

15
all intellectual property rights in any information supplied by RBG are owned by, or

UC
UB254C UB254x146x31 licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
licence to use the intellectual property rights for the express purpose.
UB356D UB356x171x45
UC152D UB457F UB457x191x82 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UB457N UB457x152x52

UC305G
UC152B

UC305G
Structural, Civil & Construction
UC152A UC152x152x51 Engineering Consultant
UC152B UC152x152x44

UC
UC152C UC152x152x37
Robert BirdGroup

15
2A
UC152D UC152x152x30
UC152E UC152x152x23 Member of the Surbana Jurong Group
VIB LEVEL 1 UB457N UB457N UB356D UC152B
UC203D UC203x203x86 DUBAI OFFICE
+681172.500 (TBC) Robert Bird Group Pty Ltd
UC203E UC203x203x71 Ph: +971 (0) 4 447 1866

UC254D

2A
Ibn Battuta Gate Email: MENA@robertbird.com.au

UC254D
UC203F UC203x203x60 Level 4, Office Suite 415 Web: www.robertbird.com

15
Jebel Ali, Dubai

UC
UC203G UC203x203x52 PO Box 118570
UC203H UC203x203x46 Dubai, United Arab Emirates TRADE LICENCE 597197
UC152B UC254D UC254x254x89 Client
UC254E UC254x254x73
MDLBEAST

UC
UC305E UC305x305x137

15
UC305F UC305x305x118

2A
UC305G UC305x305x97
UC356U UC356x368x177
VB1 70 DIA BAR OR MACALLOY

2A
460 M76 (OR EQUIVALENT)

15
Project

UC
VB2 80 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT) SOUNDSTORM 2023
GROUND FLOOR LEVEL
UC152B
+673485.000 (TBC) PF5
PF1 PF1
NOTES:
*FPS100x10 TO BE TACK WELDED Title
ON THE BOTTOM FLANGE OF
THE MAIN BEAMS BIG BEAST STAGE ELEVATION
ALONG GRID D

ELEVATION ALONG GRID D AND GRID G (MIRRORED)


SCALE 1 : 100
Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:33 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14010 A02


ST
AG
E
D
C
G

D
C

G
G
G
G
D
C

ORG
S T 0
A E -8 'x '4

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

1 2 3 4 5 6 7 KEY PLAN

2400 8900 9500 2400 12000 2700

GENERAL NOTES
UPPER ROOF LEVEL UC152E UC203H UC203H UC203H UC203H UC203H UC203H UC152D 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
METERS UNLESS NOTED OTHERWISE.
+709485.000 (TBC)

UC152E

UC152E

UC152D

UC152D

UC152D

UC152D

UC152D

UC152D

UC152D
2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
DIMENSIONS ARE TO BE FOLLOWED.
UPPER ROOF BOTTOM 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
CHORD PLAN OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
+706785.000 (TBC) UC152E UC203H UC203H UC203H UC203H UC203H UC203H UC152D SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND
M9307-RBG-PS007-ZZ-DR-ST-0003.

4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER


SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.

5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.

6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES

7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE


MEMBER TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).
B ....... BEAM
SC ....... STEEL COLUMN
VB ....... VERT CROSS BRACE
HB ....... HORIZ. CROSS BRACE

LOWER ROOF LEVEL UC152E UC152E UC203H UC203H UC203H UC203H UC203H
+697385.000 (TBC) STEEL COLUMN SCHEDULE

UC152D
UC152D

UC152D

UC203H

UC203H
UC152E

UC152E
UC152E

UC152E

MARK SIZE
a UC152x152x51
c UC152x152x23
LOWER ROOF BOTTOM PLAN d UC203x203x86
+694685.000 (TBC) UC152E UC152E UC203H UC203H UC203H UC203H UC203H e UC203x203x71
f UC203x203x60
LEVEL 4
g UC203x203x46
+694085.000 (TBC) j UC254x254x89
k UC254x254x73
MEP LEVEL 3 m UC305x305x137
n UC305x305x118
+691620.000 (TBC)
p UC305x305x97
q UC356x368x177
r UC152x152x30

STEEL FRAMING SCHEDULE A02 ISSUE FOR TENDER Jo.Na Ro.Se 02/06/23
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 16/05/23
MARK SIZE
Rev Revision Description By App Date
VIB LEVEL 2 CHS244F UKCHS244.5x10 SCALE 1 2 3 4 5 6 7 8

+686697.500 (TBC) FIS_248A FABRICATED BEAM (REFER TO Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the
accuracy, currency or completeness of any information or data they supply or transfer by electronic means.
TABLES FOR DIMENSIONS) You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
FIS_248B FABRICATED BEAM (REFER TO liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
TABLES FOR DIMENSIONS) or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
damage however caused which you or any other party may directly or indirectly suffer in connection
FPS100x10 FPS100x10 with your access to or use of that information or data.
RBG provides this information for the express purpose contemplated by the underlying
UB178A UB178x102x19 terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
UB254C UB254x146x31 all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
UB356D UB356x171x45 licence to use the intellectual property rights for the express purpose.

UB457F UB457x191x82 DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS


UB457N UB457x152x52 REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
UC152A UC152x152x51 Structural, Civil & Construction
VIB LEVEL 1 UC152B UC152x152x44 Engineering Consultant

+681172.500 (TBC) UC152C UC152x152x37


UC152D
UC152E
UC152x152x30
UC152x152x23
Robert BirdGroup
Member of the Surbana Jurong Group
UC203D UC203x203x86
DUBAI OFFICE
UC203E UC203x203x71 Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
UC203F UC203x203x60 Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
UC203G UC203x203x52 Jebel Ali, Dubai
UC203H UC203x203x46 PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
UC254D UC254x254x89
Client
UC254E UC254x254x73
UC305E UC305x305x137 MDLBEAST
UC305F UC305x305x118
UC305G UC305x305x97
UC356U UC356x368x177
VB1 70 DIA BAR OR MACALLOY
GROUND FLOOR LEVEL S1 460 M76 (OR EQUIVALENT)
+673485.000 (TBC) VB2 80 DIA BAR OR MACALLOY Project
460 M76 (OR EQUIVALENT)
SOUNDSTORM 2023

NOTES:
ELEVATION ALONG GRID E *FPS100x10 TO BE TACK WELDED
ON THE BOTTOM FLANGE OF
Title
SCALE 1 : 100 THE MAIN BEAMS BIG BEAST STAGE ELEVATION
ALONG GRID E

Date Drawn
02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
Ja.Hu
Approved
Ra.Ma

02/06/2023 6:22:36 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14011 A02


MEMBER

ST
B ....... BEAM

AG
C D E F G H

E
D
C
G

SC ....... STEEL COLUMN


D
C

G
G
G
G
D
C

VB ....... VERT CROSS BRACE


HB ....... HORIZ. CROSS BRACE 0
A E -8 'x '4
ORG
S T

2 0
C 'O O
NF
ORG
S T 0
A E -8 'x '4

T
A
I E
C
IR
N
COUT NRE COUT NR E COUT NRE
S R C
E IV E C
E IV E
S R C
E IV E
S R

2400 11200 3600 11200 2400 KEY PLAN

5G

5G

5G

5G
30

30

30

30
UC

UC
GENERAL NOTES

UC

UC
LEVEL 4 UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G 1. ALL DIMENSIONS ARE IN MILLIMETERS AND LEVELS ARE IN
+694085.000 (TBC) METERS UNLESS NOTED OTHERWISE.

UC305F

UC305F

UC305F

UC305F

UC305F

UC305G
UB
UC305G
3F
UC

UC305F

UC305F
UC UC

UC305F

UC305F
20 UC

17
20 20 20 20 3F 3F F F 2. DO NOT SCALE FROM THIS DRAWINGS. ONLY WRITTEN
3F 03 03
UC

8A

UB A

UB A

UB A

UB A
8A

UB A

UB A

UB A
8A

UB A
8A
3F 3 F 3 F 20 20 C2 C2
DIMENSIONS ARE TO BE FOLLOWED.

8
UC UC

17

17

17

17

17

17

17

17

17

17

17
U U

UB

UB

UB
MEP LEVEL 3 MEP LEVEL 3 3. ALL DIMENSIONS ARE TO BE READ IN CONJUNCTION WITH ALL
+691620.000 (TBC) UB457F UC305G UC305G UC305G UC305G UC305G UC305G UC305G UC305G UB457F +691620.000 (TBC) OTHER RELEVANT DRAWINGS. THE GENERAL NOTES AND STEEL
UB356D

7N
UB
SPECIFICATIONS REFER M9307-RBG-PS007-ZZ-DR-ST-0002 AND

7N
7N
FIS_248B
45

45

45
FIS_248A M9307-RBG-PS007-ZZ-DR-ST-0003.

45
7N

UB

8A

UB
UB

24
4. THE STRUCTURE IS TO BE ASSEMBLED USING TOWER

S_
FI
SEGMENTS/TRUSSES BOLTED TO EACH OTHER USING SINGLE
IN PIN CONNECTIONS. THE MEMBERS OF EACH SEGMENT TO BE
FULLY WELDED AT CONNECTION POINTS.
ABEYANCE
5. FOR THE SINGLE PIN CONNECTIONS ONLY: ALL HOLES AND PINS

UB A

UB A

UB A
8A

UB A
8A
UB A

UB A

UB A

UB A
8A
7N

UB

8
8

17

17

17

17

17

17
17

17

17

17

17
ON THE PLATES TO BE MACHINED FOR A TIGHT FIT.
45

45

UB

UB
UB
UB

7N
VIB LEVEL 2 UB457F UB457F VIB LEVEL 2
6. SECONDARY BEAMS UB178A TO BE INSTALLED AT 900mm CENTRES
+686697.500 (TBC) +686697.500 (TBC) UB356D

7N
7N
7. FLOOR DECK TO BE OF 'SOLID TOP' GRP GRATING' 50-55mm ABLE
FIS_248B

45
FIS_248A

45

8A
TO SUPPORT 5.0kPa FOR THE VIB LEVELS AND 7.5KPa FOR THE MEP

UB
UB

24
LEVELS OVER 900mm SPAN (TO BE DESIGNED BY OTHERS).

S_
FI

UC305G
UC254E
UC305G

UC305G

UC305G

UC305G

UB A

UB A
UB N
UB A

8A

UB A

UB A

UB A
8A

UB A
8A
7N

UB

8
8

8
17

17
45
17

17

17

17

17

17

17

17
45

45

UB

UB

UB
UB

7N
VIB LEVEL 1 UB457F UB457F VIB LEVEL 1
+681172.500 (TBC) +681172.500 (TBC) UB178A

7N
7N
FIS_248B
FIS_248A

45
45

8A

UB
UB

24
S_
FI
PLAN AT GROUND LEVEL PLAN AT GROUND LEVEL
MEMBER MEMBER
+674958.485 (TBC) +674958.485 (TBC)

GROUND FLOOR LEVEL GROUND FLOOR LEVEL


+673485.000 (TBC) S1 +673485.000 (TBC) PF5
PF1 PF1 PF1
A01 ISSUE FOR TENDER Jo.Na Ra.Ma 02/06/23
Rev Revision Description By App Date
SCALE 1 2 3 4 5 6 7 8
Disclaimer: Robert Bird Group Pty Ltd ACN 010 580 248 and its related entities (RBG) do not warrant the

1 A accuracy, currency or completeness of any information or data they supply or transfer by electronic means.

SECTIONPS007-ZZ-DR-ST-12013 SECTIONPS007-ZZ-DR-ST-12010 You are responsible for verifying that any information or data supplied or transferred by electronic means
matches the information or data on the corresponding PDF or DWF version issued by RBG. RBG will not be
liable for any loss or damage you or any other party incurs as a result of acting in reliance on any information
SCALE 1 : 100 or data supplied or transferred by electronic means and you release RBG from any liability for any loss or
SCALE 1 : 100 damage however caused which you or any other party may directly or indirectly suffer in connection
with your access to or use of that information or data.
STEEL COLUMN SCHEDULE STEEL FRAMING SCHEDULE RBG provides this information for the express purpose contemplated by the underlying
terms of engagement for the project which must not be used for any other purpose. The
information is not a contractual document. Unless otherwise agreed in writing by RBG,
MARK SIZE MARK SIZE all intellectual property rights in any information supplied by RBG are owned by, or
licensed to, RBG. RBG only provides you with a non-transferrable, fully revocable
a UC152x152x51 CHS244F UKCHS244.5x10 licence to use the intellectual property rights for the express purpose.

c UC152x152x23 FIS_248AFABRICATED BEAM (REFER TO DO NOT SCALE DRAWINGS, USE FIGURED DIMENSIONS
d UC203x203x86 TABLES FOR DIMENSIONS) REFER TO GENERAL NOTES UNLESS NOTED OTHERWISE
e UC203x203x71 FIS_248B FABRICATED BEAM (REFER TO Structural, Civil & Construction
f UC203x203x60 TABLES FOR DIMENSIONS) Engineering Consultant

g UC203x203x46 FPS100x10 FPS100x10

k
j UC254x254x89
UC254x254x73
UB178A
UB254C
UB178x102x19
UB254x146x31
Robert BirdGroup
Member of the Surbana Jurong Group
m UC305x305x137 UB356D UB356x171x45
DUBAI OFFICE
n UC305x305x118 UB457F UB457x191x82
Robert Bird Group Pty Ltd Ph: +971 (0) 4 447 1866
p UC305x305x97 UB457N UB457x152x52 Ibn Battuta Gate Email: MENA@robertbird.com.au
Level 4, Office Suite 415 Web: www.robertbird.com
q UC356x368x177 UC152A UC152x152x51 Jebel Ali, Dubai
r UC152x152x30 UC152B UC152x152x44 PO Box 118570
Dubai, United Arab Emirates TRADE LICENCE 597197
UC152C UC152x152x37
TFW UC152D UC152x152x30 Client

UC152E UC152x152x23 MDLBEAST


UC203D UC203x203x86
UC203E UC203x203x71
UC203F UC203x203x60
TFT

UC203G UC203x203x52
D

BFT

UC203H UC203x203x46
WT UC254D UC254x254x89 Project
FABRICATED I SECTIONS UC254E UC254x254x73
UC305E UC305x305x137
SOUNDSTORM 2023
BFW 'TFT' TOP FLANGE 'BFW' BTM FLANGE 'BFT' BTM FLANGE 'WT' WEB WEB TO FLANGE WELD ADDITIONAL UC305F UC305x305x118
BEAM REF DEPTH 'D' DEPTH 'D1' SIZE Volume WEIGHT 'TFW' TOP FLANGE WIDTH
THICKNESS WIDTH THICKNESS THICKNESS WELD NOTES NOTES
UC305G UC305x305x97
FABRICATED BEAM (REFER TO
FABRICATED FIS_248A 1000 1000 7.29 m³ 57203.91 kg 250 25 250 25 20 12 - - UC356U UC356x368x177
TABLES FOR DIMENSIONS)
VB1 70 DIA BAR OR MACALLOY
'I' SECTION (FIS) FIS_248B 1000 500
FABRICATED BEAM (REFER TO
1.89 m³ 14850.16 kg 250 25 250 25 20 12 - - 460 M76 (OR EQUIVALENT)
TABLES FOR DIMENSIONS) Title
LENGTH VB2 80 DIA BAR OR MACALLOY
460 M76 (OR EQUIVALENT) BIG BEAST STAGE SECTIONS
TFT

NOTES:
*FPS100x10 TO BE TACK WELDED
D1

ON THE BOTTOM FLANGE OF


THE MAIN BEAMS Date Drawn
D

02/06/23 Jo.Na
Scale at A1 Designer
As indicated Ma.Ch
Design Checker
BFT

Ja.Hu
Approved
LONGITUDINAL Ra.Ma
'I' SECTION (FIS)

02/06/2023 6:22:40 PM
FOR TENDER
Drawing Number Revision

M9307-RBG-PS007-ZZ- DR-ST-14012 A01