NEC700, 701, 702, 708 Olympian generator sets are designed, engineered
and manufactured for optimal performance. All major
components are tested individually; once assembled,
the entire unit is tested at and above 100% of rated
ISO9001, 8528, 3046, 7637, Pluses #2b, 4
load for safety and operation.
LG Series
Standard Features
ENGINE SYSTEM ALTERNATOR SYSTEM ENCLOSURE (if selected)
General UL2200 GENprotect™ Rust-proof fasteners with nylon washers to
Oil Drain Extension Class H insulation material protect finish
Air Cleaner 2/3 Pitch High performance sound-absorbing material
Fan Guard Skewed Stator Gasketed doors
Stainless Steel flexible exhaust connection Permanent Magnet Excitation Stamped air-intake louvers
Critical Exhaust Silencer Sealed Bearings Air discharge hoods for radiator-upward
Factory Filled Oil Amortisseur winding pointing
Radiator duct adapter (open set only) Full load capacity alternator Stainless steel lift off door hinges
Stainless steel lockable handles
Fuel System GENERATOR SET Rhino Coat™ - Textured polyester powder coat
Primary and Secondary Fuel Shutoff
Internal Genset Vibration Isolation
Flexible Fuel Line - NPT Connection
Separation of circuits - high/low voltage
Separation of circuits - multiple breakers
Cooling System
Wrapped Exhaust Piping
Closed Coolant Recovery System
Standard Factory Testing
UV/Ozone resistant hoses
2 Year Limited Warranty (Standby rated Units)
Factory-installed Radiator
1 Year Warranty (Prime rated units)
Radiator drain extension
Silencer mounted in the discharge hood
50/50 Ethylene glycol antifreeze
(enclosed only)
CONTROL SYSTEM
Real/Reactive/Apparent Power Single point ground
All Phase AC Voltage 15 channel data logging
All Phase Currents 0.2 msec high speed data logging
Oil Pressure Alarm information automatically comes up
Coolant Temperature on the display
Coolant Level Alarms
Engine Speed Oil Pressure (Pre-programmable Low
Battery Voltage Pressure Shutdown)
Frequency Coolant Temperature (Pre-programmed High
Control Panel
Date/Time Fault History (Event Log) Temp Shutdown)
Digital H Control Panel - Dual 4x20 Display
Isochronous Governor Control Coolant Level (Pre-programmed Low Level
Programmable Crank Limiter
Waterproof/sealed Connectors Shutdown)
7-Day Programmable Exerciser
Audible Alarms and Shutdowns Low Fuel Pressure Alarm
Special Applications Programmable PLC
Not in Auto (Flashing Light) Engine Speed (Pre-programmed Over speed
RS-232/485 Shutdown)
Auto/Off/Manual Switch
All-Phase Sensing DVR Battery Voltage Warning
E-Stop (Red Mushroom-Type)
Full System Status Alarms & warnings time and date stamped
NFPA110 Level I and II (Programmable)
Utility Monitoring Alarms & warnings for transient and steady
Customizable Alarms, Warnings, and Events
Low Fuel Pressure Indication state conditions
Modbus protocol
2-Wire Start Compatible Snap shots of key operation parameters
Predictive Maintenance algorithm
Power Output (kW) during alarms & warnings
Sealed Boards
Power Factor Alarms and warnings spelled out (no alarm
Password parameter adjustment protection
kW Hours, Total & Last Run codes)
G175LG4 175 kW
LG Series
Configurable Options
ENGINE SYSTEM GENERATOR SET ENCLOSURE
General Gen-Link Communications Software Standard Enclosure
Engine Block Heater (English Only)
Level 1 Sound Attenuation
Oil Heater Extended Factory Testing (3 Phase Only)
Level 2 Sound Attenuation
Air Filter Restriction Indicator IBC Seismic Certification
Steel Enclosure
Stone Guard (Open Set Only) 8 Position Load Center
Aluminum Enclosure
2 Year Extended Warranty
Engine Electrical System 150 MPH Wind Kit
5 Year Warranty
10A UL battery charger 12 VDC Enclosure Lighting Kit
5 Year Extended Warranty
2.5A UL battery charger 120 VAC Enclosure Lighting Kit
Battery Warmer AC/DC Enclosure Lighting Kit
Door Alarm Switch
ALTERNATOR SYSTEM CIRCUIT BREAKER OPTIONS
Alternator Upsizing Main Line Circuit Breaker
Anti-Condensation Heater 2nd Main Line Circuit Breaker
Tropical coating Shunt Trip and Auxiliary Contact
Electronic Trip Breakers
CONTROL SYSTEM
21-Light Remote Annunciator Remote E-Stop (Break Glass-Type, Surface Remote Communication - Modem
Remote Relay Panel (8 or 16) Mount) Remote Communication - Ethernet
Oil Temperature Sender with Indication Remote E-Stop (Red Mushroom-Type, 10A Run Relay
Alarm Surface Mount) Ground fault indication and protection
Remote E-Stop (Red Mushroom-Type, functions
Flush Mount)
Engineered Options
ENGINE SYSTEM GENERATOR SET CONTROL SYSTEM
Coolant heater ball valves Special Testing Spare inputs (x4) / outputs (x4) - H Panel
Fluid containment pans Battery Box Only
Battery Disconnect Switch
ALTERNATOR SYSTEM ENCLOSURE
Rating Definitions
Standby – Applicable for a varying emergency load for the duration of a utility power outage with no overload capability.
Prime – Applicable for supplying power to a varying load in lieu of utility for an unlimited amount of running time. A 10% overload capacity is available for 1 out of
every 12 hours. The Prime Power option is only available on International applications.
Power ratings in accordance with ISO 8528-1, Second Edition dated 2005-06-01, definitions for Prime Power (PRP) and Emergency Standby Power (ESP).
G175LG4 175 kW
ALTERNATOR SPECIFICATIONS
Natural Gas
Single-Phase 120/240 VAC @1.0pf 175 kW Amps: 729
Three-Phase 120/208 VAC @0.8pf 175 kW Amps: 607
Three-Phase 120/240 VAC @0.8pf 175 kW Amps: 526
Three-Phase 277/480 VAC @0.8pf 175 kW Amps: 263
Three-Phase 346/600 VAC @0.8pf 175 kW Amps: 210
*Fuel supply installation must accommodate fuel consumption rates at 100% load.
COOLING
Standby
Air Flow (inlet air combustion and radiator) ft3/min (m3/min) 9389 (265.9)
Coolant Flow per Minute gpm (lpm) 79 (299)
Coolant System Capacity gal (L) 6.1 (23.1)
Heat Rejection to Coolant BTU/hr 597,740
Max. Operating Air Temp on Radiator ºF (ºC) 122 (50)
Max. Operating Ambient Temperature (Before Derate) ºF (ºC) 110 (43.3)
Maximum Radiator Backpressure in H2O 0.5
Standby
Flow at Rated Power cfm (m3/min) 389 (11.0)
ENGINE EXHAUST
Standby Standby
Rated Engine Speed rpm 1800 Exhaust Flow (Rated Output) cfm (m3/min) 1349 (38.2)
Horsepower at Rated kW** hp 267 Maximum Recommended Back Pressure inHg 1.5
Piston Speed ft/min (m/min) 1773 (540) Exhaust Temp (Rated Output) ºF (ºC) 1378 (748)
BMEP psi 157 Exhaust Outlet Size (Open Set) in 3.5" I.D. Flex (No Muffler)
** Refer to “Emissions Data Sheet” for maximum bHP for EPA and SCAQMD permitting purposes.
Deration – Operational characteristics consider maximum ambient conditions. Derate factors may apply under atypical site conditions. Please consult a CAT® Dealer for additional details. All perfor-
mance ratings in accordance with ISO3046, BS5514, ISO8528 and DIN6271 standards.
G175LG4 175 kW
STANDARD ENCLOSURE
L x W x H in (mm) 153.89 (3909) x 52.73 (1339.3) x 69.67 (1769.6)
Steel: 6577 (2983)
Weight lbs (kg)
Aluminum: 6035 (2738)
Sound Level (dBA*) 79.9
*All measurements are approximate and for estimation purposes only. Sound levels measured at 23 ft (7 m) and does not account for ambient site conditions.
Information contained in this publication may be considered confidential. Discretion is recommended when distributing. www.OlympianPower.com
Materials and specifications are subject to change without notice. 0K4294Y09-D 04/02/14
CAT, CATERPILLAR, their respective logos, OLYMPIAN, “Caterpillar Yellow”, the “Power Edge” trade dress as © 2014 Caterpillar
well as corporate and product identity used herein, are trademarks of Caterpillar and may not be used without permission. All rights reserved.
Printed in U.S.A.