You are on page 1of 1

A B C D

7040 7040 5860


600

1
B2(230X400) B2(230X400) B2(230X400)

1200
B1(230X300)

B1(230X300)

B1(230X300)
B1(230X300)
5200

S1 S1 S1

2300 2300
B2(230X400) B2(230X400) B2(230X400)
2
1800

S1 S1 S1

1200
B2(230X400) B2(230X400) B2(230X400)
3
BEAM & SLAB LAYOUT
STRUCTURAL CONSULTANTS :
NOTES.
230 230 STRUCTURAL AUDIT & SOLUTIONS
G1. DO NOT SCALE ANY DIMENSIONS FOLLOW ONLY WRITTEN DDA-508, Pul Pehlad Pur, New Delhi, 110044
DIMENSIONS.
Ld+2d COLUMN G2. ALL STRUCTURAL DRAWINGS SHOULD BE READ IN PROJECT :
400

300

CONJUCTION WITH RELEVANT ARCHITECTURAL DRAWINGS. PRIMARY SCHOOL JHS KHODNA


ANY DISCREPANCY OR AMBIGUITY IN EITHER SHOULD
BE BROUGHT TO THE NOTICE OF THE ARCHITECT KHURD, KHODNA KHURD, GAUTAM
G3. USE CONC. GRADE M25 UNLESS NOTED OTHERWISE BUDDHA NAGAR
Ld G4. REFER TO HIGH YEILD STRENGTH DEFORMED BARS DRAWING TITLE :
WITH CHARACTERSTIC STRENGTH OF 550D N/sq. mm.
BEAM & SLAB LAYOUT & DETAILS
BEAM SCHEDULE OF SLAB MARKING
DATE : 27-7-2023 SCALE :

SL. SLAB BOTTOM REINF.IN BOTTOM REINF.IN SLAB


EXTRA AT TOP R/F DRAWING NO. :
NOS. MARKED SHORT DIRECTION LONG DIRECTION THK. DRAWN : KIRAN
4
1. S1 10#@100C/C 10#@100C/C 10#@100C/C 150 REVISION NO. :
CHECKED : R. KUMAR
R-0