USE OR OCCUPANCY ZONING BHL FLAR GFA TO TGFA

TYPE OF BUILDING/STRUCTURES DESIGNATIONS/RIGHTS CONVERTION


Excluded
Allowable floor areas
Multiplier
storeys/ (non-GFA)
GROUP RESIDENTIAL floors above
Meters above
as a
to convert
A (Non-Leasing) established
highest grade
percentage
the GFA to
TGFA
grade of the
TGFA

A-1 Single Family Occupants R1 Low-density Residential


3 10.00 m
1.50
33% 1.50
ZONE (Single Detached) (at a 3-storey or 10.00 m BHL)
DIVISION

Medium-density Residential
(Duplex)
A-2 Not exceeding 10 persons R2 Basic R2 1-3 Storeys 3 10.00 m
1.30 – 1.50
20% 1.25
ZONE (at a 3-storey or 10.00 m BHL)
15.00 m 2.10 – 3.00
Max R2 3-5 Storeys 5 16% 1.20
(at a 5-storey or 15.00 m BHL)
GROUP RESIDENTIAL
B (Leasing)
High-density Residential
(Low-rise or Medium-rise)
R3 Basic R3 Rowhouse 1-3 Storeys 3 10.00 m
1.80 – 2.10
20% 1.25
ZONE (at a 3-storey or 10.00 m BHL)
DIVISION

7.10 – 8.10
(rowhouse, townhouse, Max R3 Medium-rise: 6-12 Storeys 12 36.00 m 16% 1.20
B-1 (at a 12-storey or 36.00 m BHL)
condominium) Medium to High-density
R4 Residential 3 10.00 m
1.60 – 1.80
20% 1.25
ZONE (at a 3-storey or 10.00 m BHL)
(Townhouse – individual lots/unit)
R5 Very High-density Residential
12-18 36.00 – 54.00 m
6.00 – 9.00
16% 1.20
ZONE (Medium-rise to High-rise Condo) (at a 18-storey or 54.00 m BHL)
GROUP
C EDUCATION & RECREATION
DIVISION

C-1 (schools) 15.00 meters


GI General Institutional
(or must follow the duly approved 2.50 – –
ZONE (Community to National Level)
C-2 (amusement halls and parlors) BHL in the major zone it is part of)

GROUP INSTITUTIONAL
D (Government and Health)
Restrained (mental hospitals,
D-1
jails, prisons)
DIVISION

15.00 meters
D-2 Health Care (non-ambulatory) GI General Institutional
(or must follow the duly approved 2.50 – –
ZONE (Community to National Level)
BHL in the major zone it is part of)
Over kindergarten age
D-3
(ambulatory)
USE OR OCCUPANCY ZONING BHL FLAR GFA TO TGFA
TYPE OF BUILDING/STRUCTURES DESIGNATIONS/RIGHTS CONVERTION
Excluded
Allowable floor areas
Multiplier
GROUP storeys/ (non-GFA)
Meters above to convert
E BUSINESS & MERCANTILE floors above
highest grade
as a
the GFA to
established percentage
TGFA
grade of the
TGFA
Light Commercial
C-1 (Neighborhood or Community Level 1 – 3 3–5 10.00 – 15.00
1.70 – 3.00
20% 1.25
ZONE (at a 5-storey or 15.00 m BHL)
storey)
No work is done (bus
E-1 15.00 meters
terminals, port, airports)
UTS Utilities, Transportation, and (or must complement the duly
2.00 – 3.00 33% 1.50
ZONE Services approved BHL in the major zone it
DIVISION

is part of)
C-2 Medium Commercial
6 18.00
3.60 – 9.00
25% 1.33
ZONE (Municipal or City Level 3 – 5 storey) (at a 15-storey or 45.00 m BHL)
E-2 Business
SPE Special
– 0.80 – –
ZONE (Cemeteries, Memorial Parks)
Metropolitan Commercial 9.00 – 34.00
E-3
No repair work is done (bus C-3 (Municipal or City Level Large – Very 16 – 60 48.00 – 180.00 (at a 60-storey or 180.00 m 33% 1.50
terminals, port, airports) ZONE Large Malls) BHL)
GROUP
F INDUSTRIAL
15.00 meters
I-1
DIVISI

No work is done (bus


ON

F-1 Light Industrial (but not exceed the duly approved 1.50 – 2.50 25% 1.33
terminals, port, airports) ZONE BHL in the major zone it is part of)
GROUP
G STORAGE & HAZARDOUS
21.00 meters
I-2 Medium Industrial (but not exceed the duly approved 2.50 – 3.00 33% 1.50
ZONE BHL in the major zone it is part of)
Hazardous and highly
G-1 15.00 meters
flammable materials
UTS Utilities, Transportation, and (or must complement the duly
DIVISION

2.00 – 3.00 33% 1.50


ZONE Services approved BHL in the major zone it
is part of)
G-2 Flammable materials
G-3 Wood working activities
Repair garages and engine
G-4
manufacture
G-5 Aircraft facilities
27.00 meters
I-3 Heavy Industrial (but not exceed the duly approved 3.00 – 5.00 33% 1.50
ZONE BHL in the major zone it is part of)
USE OR OCCUPANCY ZONING BHL FLAR GFA TO TGFA
TYPE OF BUILDING/STRUCTURES DESIGNATIONS/RIGHTS
Excluded
Allowable floor areas
Multiplier
storeys/ (non-GFA)
GROUP ASSEMBLY LESS THAN 1000 floors above
Meters above
as a
to convert
H (Cultural and/or Recreational) established
highest grade
percentage
the GFA to
TGFA
grade of the
TGFA
Park Structures, Recreation & 15.00 meters
PRE Entertainment (or must complement the duly
0.50 – 1.00 – –
ZONE approved BHL in the major zone it is
H-1 Less than 1000 (Educational uses) part of)
DIVISION

30.00 meters
CUL Cultural
(or must follow the duly approved BHL 3.50 – –
ZONE (Community to National Level) in the major zone it is part of)
H-2 300 or more
H-3 Less than 300
H-4 Uses not included in H-1
GROUP ASSEMBLY MORE THAN 1000
I (Cultural and/or Recreational)
30.00 meters
CUL Cultural
(or must follow the duly approved BHL 3.50 – –
DIVISION

(sports complexes, theaters, ZONE (Community to National Level) in the major zone it is part of)
I-1 convention centers, concert Park Structures, Recreation & 15.00 meters
halls and open houses) PRE Entertainment (or must complement the duly
0.50 – 1.00 – –
ZONE approved BHL in the major zone it is
(Educational uses) part of)
GROUP
J ACCESSORY
A Agricultural 15.00 meters
ZONE (or must complement the duly 1.03 –
J-1 (agricultural structures) 1.80 – 2.20 2% – 5%
AI Agro-Industrial
approved BHL in the major zone it is
part of)
1.06
ZONE
PLANNED UNIT DEVELOPMENT
(site with CDMP)
10.00 – 45.00
DIVISION

at reclamation area close to an


operating airport
3 – 15 (with ATO - Prescribed 6.00
BHL as needed)

J-2
(private garages, towers, PUD at reclamation area 3 – 30 10.00 – 30.00 6.00 – 12.00
swimming pools, fence) ZONE 16 – 45 48.00 – 135.00 12.00 – 18.00
at coastal area – –
at an inland area close to an operating 10.00 – 75.00
airport
3 – 25 (with ATO - Prescribed 6.00 – 18.00
BHL as needed)

at an inland area 12 – 60 36.00 – 180.00 9.00 – 34.00


(at a 60-storey or 180.00 m BHL)
(stages, courts, tombs,
J-3
mausoleums, zoo, banks)