7.2.3.

ALARMS MENU -

FAILURES EV01 : OK 1/32


Detected: 03 Status: inactive
Active : 02 Times : 004
(+-) Erase Failures EV TOR Short Circuit

EV02 : FAIL 2/32


Status: active
Times : 002
EV TOR Open Circuit

EV03 : FAIL 1/32


Status: inactive
Times : 004
EV TOR Short Circuit

Category Code display Detail Notice

Monitored valves: YV40 (if


machine with pressure
transducer or without load
management system),
YV22A, YV22B, YV13,
YV21A, YV21B, YV19A,
Short-circuit on
YV19B, YV15A, YV15B,
Electrovalves EV01 EV On.Off Short C. ON/OFF
YV18A, YV18B, YV9 (if
electrovalve
machine H18SX or H18SXL),
YV25, YV14A, YV17, YV8,
YV12, YV10, YV11, YV20 (if
generator powered)
check the wiring and/or
valves
Monitored valves: YV40 (if
machine equipped with
pressure transducer or
without load management
system), YV22A, YV22B,
YV13, YV21A, YV21B,
Circuit-open YV19A, YV19B, YV15A,
EV02 EV On.Off Open C. on ON/OFF YV15B, YV18A, YV18B, YV9
electrovalve (if machine H18SX or
H18SXL), YV25, YV14A,
YV17, YV8, YV12, YV10,
YV11, YV20 (if generator
powered
check the wiring and/or
valves

84/120
TRAINING MANUAL DIAGNOSTIC Level 2 HSX Range
2420339180 E03-12
Short-circuit on
electrovalve check the wiring and/or
EV03 EV PWM1 Short C.
proportional 'electrovalve PWM1
PWM1
Open circuit on
electrovalve check the wiring and/or
EV04 EV PWM1 Open C.
proportional valve PWM1
PWM1
Short-circuit on only for machines with angle
electrovalve pressure
EV05 EV PWM2 Short C.
proportional check the wiring and/or
PWM2 valves
Open circuit on only for machines with angle
electrovalve pressure
EV06 EV PWM2 Open C.
proportional check the wiring and/or
PWM2 valves
Problem of check the key selector for
AL01 FU5 FU6 Fuses selection of controls
station check fuses FU5 and FU6
Fuses fuse FU7
AL02 FU7 Fuse check fuse FU7
blown
fuse FU8
AL03 FU8 Fuse check fuse FU8
blown
Problem in the
Emergency circuit of check the circuit of
AU01 Emergency circuit
circuit emergency emergency stop
stop
Off neutral
credit and check wiring joystick
JY01 SM4 neutral joystick with check wiring off neutral
the neutral signal
during 400ms
Off neutral
Joystick check wiring joystick
inactive and off
JY02 SM4 out of neutral check wiring off neutral
neutral joystick
signal
during 400ms
Joystick check wiring joystick
JY03 SM4 out of range except range check wiring off neutral
during 400ms signal
Calibration
No Overload tables angle
Overload OL01 make the calibration
Learning not effecutée
pressure

85/120
TRAINING MANUAL DIAGNOSTIC Level 2 HSX Range
2420339180 E03-12
adjust the angle sensor
Calibration
make the calibration
angle KB: out
(scissors stowed),
OL02 Angle learning Fault of range low
SL5Lin = 930pts+/-20pts
value or range
Upper position:
high value
SL5Lin=210pts+/-20pts
check the wiring
Check the signal SL5
angle sensor : 4mA-20mA
angle sensor (scissors stowed),
OL03 Angle out of range
out of range SL5Lin = SL5Lin Calib+/-
20pts
Upper position:
SL5Lin=SL5Lin Calib+/-20pts
Failure present as long as
Analogical the machine has not been
inconsistency restarted
angle value Check wiring SQ3
OL04 SQ3 Angle incoh.
and state Check the state of signal
contactor SL5
position SQ3 Check the calculated angle
and the state of SQ3
Failure present as long as
Analogical the machine has not been
inconsistency restarted
angular value Check wiring SQ4
OL05 SQ4 Angle incoh.
and state Check the state of signal
contactor SL5
position SQ4 Check the calculated angle
and the state of SQ3
check the wiring
check the state of the signal
pressure
G1 pressure sensor:
OL06 Press out of range sensor out of
0.5V-4.5V
range
menu (scissors stowed),
G1 around 500mV
Battery of module
BT01 Battery empty change the module
ECU module discharged

Level of
OPTION State Significance
access

Inactive by default
Inactive if Activates, activation buzzer
All Mvt Buzzer 1
Active on movements of drive,
steering and lifting

Inactive by default
Inactive
Trans. Buzzer 1 if Activates, activation buzzer
Active
on movements of drive

86/120
TRAINING MANUAL DIAGNOSTIC Level 2 HSX Range
2420339180 E03-12
Inactive by default
Inactive
Down Mvt. Buzzer 1 if activates, activation buzzer
Active
on movements of descent

Inactive by default
Inactive if activates, activation of the
Auto stabilizer 1
Active command of the centralized
outriggers

Standard by default
Type of the platform:
Standard if XL, lift is forbidden
Standard Platform 1
XL for H15SX and H18SX no PF
lifting if outriggers not on
ground > SQ3

NoSelection
No selection by default
H12
Standard machine 1 type of the machine: if no
H15
selmection , no movement
H18

No Selection by default
NoSelection
Engine type : in slected , no
Hatz
Standard engine 1 start ( double check done by
Perkins
the module for eengine
GM
connections )

Inactive by default
Inactive if activates, H18SX activation
Slope Trans light 1
Active in the event of tilt for Hatz and
Perkins engines

Inactive by default
if activates, Interdiction
Inactive
Prohib In Tilt signal 1 drive/lifting in tilt (Canada only
Active
taken into account with
country” option US )

Inactive by default
Inactive
Cold Country 1 if activates, activation longer
Active
preheating for cold country

EUR by default
EUR Country of the machine:
Country 3 AUS attention according to the
USA option choice , some safety
could be by-passed

87/120
TRAINING MANUAL DIAGNOSTIC Level 2 HSX Range
2420339180 E03-12
PressureSwitch by default
if Pressure Switch: choice
overload control done by B6
and descent control by YV40
PressureSwitch
(ON/OFF valve)
Weighing 3 Angle Pressure
If Angle Presses: control
NoSelection
overload control done by
transducers SL5 /SP140 +
descent control by PWM valve
(YV40 renamed PWM2 )

regulate this value via menu


PWM2 Down low 3 0...100
“PWM SETTINGS”

regulate this value via menu


PWM2 Down HIGH 3 0...100
“PWM SETTINGS”

88/120
TRAINING MANUAL DIAGNOSTIC Level 2 HSX Range
2420339180 E03-12