Question Answer A AnswerB Answer C Answer D Answer Ans


No. E wer

1. How many control tags per group can be configured in 10 08 12 30 C


GROUPTREND of an Environment.
2. What is the highest redundancy achievable for SC/C 3:1 11:1 1:1 none of the C
Controllers above
3. The command used to reboot HP UNIX station is shutdown -a 0 shutdown -r 0 shutdown -h 0 switch off and on. B
4. What is minimum scanning rate of a loop in SC 010 ms 100 ms 1000 ms None of above B
Controller
5. Version of HP-UNIX in ABB work stations after Y2K is 9.05 7 10.2 None of above C
6. What is the sequence of appending a loop in a control Install, compile & install, compile, Download, install, None of above B
module? download Switch OFF loop & compile
download
7. In an Engineering workstation, Decompile utility is used copying the databasecopying FMS backup Updating the updating the D
for into a DAT tape into a DAT tape controller with runtime
changes changed
parameters
into thesource
database.
8. The Lower Bound Count possible in the DCS system is 4000 20000 0 4095 A
9. The maximum cable length for RS232 communication is . 50 Feet 4000 Feet 200 Feet None of above A
10. The sequence to be followed for configuring tag in a log typical, log composite log, log log typical, none of the A
history is group, composite log group, log typical composite log, log above.
group
11. What is the main function of Positioner in control valve Stroke checking Pneumatic signal Split range All of Above D
amplification operation
12. What is Trim parts in control valve Plug Seat Body All of the Non of the D
above above
13. Fins type of bonnet control valves are used in Hydro carbon High temperature Vacuum High pressure B
application application application application
14. What type of Gland packing used in steam service V-ring PTFE PTFE Rop Grafoil All of the C
packing above
15. What is the difference between 3051 and 1151 Rosemount 3051 is smart and 3051 is non smart Hart comm. Non of the All of the A
Tx.meter 1151 is Non and 1151 is smart can be used above above
smart with 1151 and
not used in
Sr. Question Answer A AnswerB Answer C Answer D Answer Ans
No. E wer

3051.
16. During Calibration of Tx.Meter Linarisation pot can be Rosemount Rosemount Rosemount All of the A
adjusted in Model 1151 Model 3051 Model 444 above
Tx.Meter Tx.Meter Tx.Meter
17. The main function of Vibration frequency of tube in Mass To measure Mass Mass flow factor Density factor Mass of A
flow meter is, flow rate flowing fluid
18. A I/P converter having an output of 0.2 to 1.0 Kg/Cm2, Less zero Error Zero Error More Zero Span Error B
and calibrated against 4 to 20 mA DC. It is showing 0.24 Error
Kg/Cm2,kindly select type of error
19. Which controller having more sensitivity, Controller having Controller having Controller All of the B
PB of 60 % PB of 20 %. having PB of above
150 %
20. Which is the more sensitive Controller with Controller with Controller with All of the A
gain of 3.0 gain of 0.5 gain of 1.0 above
21. What is the main function of Carrier Gas in Gas Push the sample Sample suction Flame Ignition Non of the All of A
Chromatograph. to Detector side through injector in Detector (In above above
via column case of FID)
22. The function of guiding Electron in FID Detector by, Collector assy. Of Polarising Jet assy. Of Pre-amplifier B
Detector electrode of Detector board of
Detector Detector
23. Which column having better resolution in Gas Packed Column Glass Column Glass Capillary Trap assy. C
Chromatograph. Column
24.What is the main function of Sulphur filter in FPD Detector Flame Detection Wave length Working as a Main Part of B
Detection pre-amplifier Photo
in FPD Multiplier
Tube
25.What is the main function of EPC Module in Gas To Increase Pressure Minimise To increase All of the C
Chromatograph. Carrier Gas Flow Regulation in GC effect of injection time above
Pressure and in GC
flow variation
in GC
26. Chopper speed variation in IR Analyser results… Loss of analysis Noisy base line in No peak Variation in B
IR analyser detection in IR sample
analyser injection
Sr. Question Answer A AnswerB Answer C Answer D Answer Ans
No. E wer

volume
27. Our Company Standard Instruments are presently certified Fluid Control Electronic Electronics and All of the A
by Research Institute Regional Testing Quality above
Palghat,Kerala Laboratory,Mu Development
mbai Centre
Gandhinagar
28. Who writes Instrumentation ISO-9000 Common Tier II, HOD CES HOD CTS Discipline All of the C
head CES above
29. By using which Calibration technique, Cal. lab. is Comparison with Comparison with Govt. of None of the B
certifying test instruments. External standard equal or higher Gujarat Weight above
accuracy CSI/TCI and Measure
Instruments. dept
30. What is the major difference between NDIR & IR Detector Detector NDIR Works Inductance None of B
analyser, Ref./Sample cell Ref./Sample Cell on principle the above
fills with same fills with different Capacitance/
Gas Gas. IR Works on
31. In case of GC, for analysis of trace components in Heart cut / Selector Cell vent flow Analytical flow Backflush vent A
presence of large concentrations of another constituents vent flow flow
which elutes before the trace contaminant, the flow used
to vent the component of larger concentration is
32. In case of GC, Analytical flow has to be set same as Splitter Vent flow Cell vent flow
Backflush vent None of above B
flow
33. Torodial conductivity sensor is used where Temp is very high Voltage cannot be Process is Process is toxic C
applied corrosive
34. The output mV of a Zirconia sensor is Linear Parabolic Logarithmic None of above C
35. Which of the following gas cannot be measured in an N2 CO CO2 CH4 A
Infra-Red analyser.
36. In case of FID, the fuel to air ratio is 1:1 1 : 10 10 : 1 100 : 1 B
37. The IR analyser is based on the principle of Nersts’ equation Beer Lambert law Seeback effect None of above B
38. The pre-amplifier of pH transmitter basically has Low input High output Low output High input D
impedance impedance impedance impedance
39. 1.0% of Methane in air equals 25% LEL 50% LEL 75% LEL 20% LEL D
40. Principle of Paramagnetic susceptibility is used to Hydrogen Nitrogen Oxygen Carbon Dioxide C
measure
Sr. Question Answer A AnswerB Answer C Answer D Answer Ans
No. E wer

41. What is the conversion factor for kg/cm2 to PSI 14.22 0.07031 1.0332 0.9678 A
42. If a measurement is taken 122 Deg. F then equivalent 50 90 162 None of the A
value in centigrade is above
43. The resistance of PT 100 RTD at 100 deg centigrade will 0 ohm 100 ohm 138.5 ohm None of the C
be above
44. Sensitivity of temperature sensor is maximum for Thermocouple RTD Thermistor C
45. What is the difference between RADAR type level Tx and Service in which it Mounting Principle of None of the C
Ultrasonic type level Tx can be used arrangement operation above
46. For measuring level by DP transmitter using wet leg Suppression Elevation Only calibration B
calibration following is required to be done
47. For measuring pressure following final sensing element Bourden tube Strain gauge Capsule All of the above D
can be used
48. For flow measurement with very low range of DP AP DP DR None of the C
following type of Tx. can be used above
49. Principle of operation for micro-motion flow Tx is Temp dispersion Couriolis effect Change in Change in B
capacitance inductance
50. Level measurement in pressurised vassal can be done by DP Tx RADAR type Tx Nucleonic type All of the above D
level Tx