Professional Documents
Culture Documents
Doors
SECTION 10.2.5.3. Window
A. Application 1. Rooms intended for any use, not provided with an
artificial ventilation system, shall be provided with a window RAMP
or windows with a total free area of openings equal to at Section 1207 A ramp conforming to the provisions of the
least 10% of the floor area of the room, provided that such Code may be used as an exit. The width of ramps shall be
opening shall be not less than 1.00 sq. meter. However, as required for corridors.
toilet and bath rooms, laundry rooms and similar rooms
shall be provided with windows or windows with an area FIRE
not less than 1/20 of the floor area of such rooms, provided
that such opening shall not be less than 240 sq. Ramp Handrails
millimeters. Such windows shall open directly to a court, SECTION 10.2.5.10
yard, public street or alley, or open watercourse. a. All fire escape shall have walls or guards on both sides,
in accordance with para “H” of Section 10.2.5.4 of this
Fire IRR, except for height, which shall be one hundred seven
centimeters(107 cm) and ninety one centimeters (91 cm)
Entrance for fire escape for every small buildings, the height being
Section 10.2.5.3 –Every door and every principal entrance measured vertically from a point on the stair tread twenty
which are required to serve as an exit shall be designed five millimeters (25 mm) back from the leading edge, or
and constructed so thatthe way of exit travel is obvious vertically above any landings or balcony floor level.
and direct.
b. All fire escape shall have handrails on both sides, not
BP less than seventy six centimeters (76 cm) not more than
one hundred seven centimeters (107 cm) high, measured
vertically from a point on the stair tread twenty five
Appendix A – C.1.2 - One (1) entrance level should be millimeters (25mm) back from the leading edge, all in
provided where elevators are accessible. general conformity to the requirements for stair handrails,
para “H” of Section 10.2.5.4 of this IRR.
Rule III 9.4 - Doors and entrances provided herein used as
entry points at entrance lobbies as local points of c. Handrails and guards shall be so constructed as to
congregation shall be designed to open easily or withstand a force of ninety one kilograms (91 kg) applied
accessible from floor to floor or to any point of destination. downward or horizontally atany point.
BP
NBC Appendix A - A.4.2 - Handrails shall be installed at 0.90m
and 0.70m above steps or ramps. Handrails for protection
at great heights may be installed at 1.0to 1.06m.
Ramp Landing BP
Section 10.2.5.7 -A ramp and the platforms and landings
associated therewith shall be designed for not less than Appendix A -C.2.2 Ramp shall have a minimum clear width
four hundred eighty eight kilos per square meter (488 of 1.20 meters.
kg/m2) live load and shall have a non-slip surface.
BP
NBC
SECTION
NBC
RAMP SLOPE
Section 1207 The slope of a ramp shall not exceed 1 in 8.
CEILING HEIGHT
Ramps shall be roughened or shall be of approved non-slip
Rule VIII Section 805 Habitable rooms provided with
material.
artificial ventilation shall have ceiling heights not less than
2.40 meters measured from the floor to the ceiling;
FIRE
provided that for buildings of more than one (1) storey, the
minimum ceiling height of the first storey shall be 2.70
Section 10.2.5.7 -The slope of a ramp shall not vary
meters and that for the second story 2.40 meters and the
between landings. Landings shall be level and changes in
succeeding stories shall havean unobstructed typical
direction of travel if any shall be made only at landings.
head-room clearance of not less than 2.10 meters above
the finished floor. Above-stated rooms
BP
Fire
Appendix A -C.2.2 The maximum gradient of ramp shall be
1:12. Section 10.2.5.2. The minimum headroom shall not be less
than two meters (2 m) nor any projection from the ceiling
be less than two meters (2 m) from the floor. NBC
Bp
STAIR RISE AND RUN
Appendix A -A.3.10 -Walkway headroom should not be Section 1207 The rise of every step in a stairway shall not
less than 2.0 meters and preferably higher. exceed 200 millimeters and the run shallnot be less than
250 millimeters.
NBC BP
STAIR WIDTH Section 10.2.5.4 –The rise of every step in a stairway shall
Section 1207 Stairways serving an occupant load of more exceed 180 mm and the run shall not be less than 280
than fifty (50) shall not be less than 1.10 meters. Stairways mm.
serving an occupant load of fifty (50) or less may be 900
millimeters wide. Private stairways serving an occupant NBC
load of less than ten (10) may be 750 millimeters. Trim and
handrails shall not reduce the required width by more than STAIR HANDRAILS
100 millimeters.
Section 1207 Stairways shall have handrails on each side
and every stairway required to be more than 3.00 meters in
Section 10.2.5.4 –Stairways serving an occupant load of width shall be provided with not less than one intermediate
less than 2000 persons shall not be less than 1120 mm in handrail for each 3.00 meters of required width.
width.
FIRE
BASEMENT
Ground Floor
NBC
NBC
Toilet and Shower Room
SECTION 806. Sizes and Dimensions of Rooms Bath and PARKING SLOTS
toilet – 1.20 sq. meters with a least dimension of 900
millimeters. Rule VII Section 707 One (1) off-street cum on-site car
parking slot for every twenty five (25) beds; and one (1)
PLUMBING off-RROW (or offstreet) passenger loading space that can
accommodate two (2) queued jeepney/shuttle slots
Section 1006- FLOOR DRAIN TRAPS Floor drain shall
connect into a trap so constipated that it can be readily
cleaned and of a size to serve efficiently the purpose which FIRE
it is intended. The drain inlet shall be so located that it is
not at times in full view. Section 10.2.18.3 -Every floor of every parking structure
shall have access to at least two(2) separate exits.
BP
BP
RULE II – MINIMUM REQUIREMENTS FOR
ACCESSIBILITY Rule I 4.1.1.D -Accessible slots in parking areas shall be
7.1 The provision of this section shall apply to the specified located as near as possible to ingress/egress spaces.
Appendix A -B.1.4 -Accessible parking slot should have a
minimum width of 3.70 meters.