You are on page 1of 6

TEST REPORT NUMBER: BGDP21000171

DATE: 29-Sep-2021

Page 1 of 6
ITS Labtest Bangladesh Ltd
Kabirpur, Ashulia, Savar, Dhaka-1349, Bangladesh, www.intertek.com
TEST REPORT NUMBER: BGDP21000171
DATE: 29-Sep-2021

APPLICANT : JMI Hospital Requisite Mfg. Ltd.


Factory: JMI Industrial Park, Vitikandi,
Gazaria-1510, Munshiganj

ATTN : Dr. Md. Zakir Hossain

Sample Description : Non Woven Surgical Face Mask


Applicant Provided Care Instructions:
-
Date Received/Date Test Started :
19-Sep-2021
:
Date received Test Request Form 19-Sep-2021
Testing Period :
19-Sep-2021To 29-Sep-2021
:
Rating -
Sample Name :
Surgical Face Mask
:
Size -
:
Colour Blue & White
Standard :
-
:
Order No -
:
Style No -
:
Buyer Name Self Reference
:
Manufacturer's Name -
Agent Name :
-
:
No Of Sample 80 Pieces
Product End Use :
-
:
Brand Name -
Batch No :
JH-SP-061-21
:
Origin -
:
Country Of Destination -
Fabric Type :
-
:
Order Quantity -
Ref. :
-As Per Local Govt. Guideline

AUTHORIZED BY
FOR ITS Labtest Bangladesh Ltd. [Textiles - Dhaka]

NEYAMUL HASAN
COUNTRY BUSINESS LINE LEADER, SOFTLINES

TEST CONDUCTED : AS PER THE REQUEST OF THE APPLICANT. FOR FURTHER DETAILS PLEASE REFER
TO ENCLOSED PAGE(S)

Page 2 of 6
ITS Labtest Bangladesh Ltd
Kabirpur, Ashulia, Savar, Dhaka-1349, Bangladesh, www.intertek.com
TEST REPORT NUMBER: BGDP21000171
DATE: 29-Sep-2021

CONCLUSION:

Bacterial Filtration Efficiency F


Differential Pressure M
Sub Micron Particulate Filtration F
Resistance To Penetration By Synthetic Blood M

Note : M = Meet Standard Requirement


# = No Specified Requirement

Page 3 of 6
ITS Labtest Bangladesh Ltd
Kabirpur, Ashulia, Savar, Dhaka-1349, Bangladesh, www.intertek.com
TEST REPORT NUMBER: BGDP21000171
DATE: 29-Sep-2021

(TESTS CONDUCTED (AS REQUESTED BY THE APPLICANT)


1. Bacterial Filtration Efficiency
(As Per EN 14683:2019+AC:2019 Medical Face Masks– Requirements And Test Method
Annex B):
Test Item Result (%) Performance
Spc. 1 Spc. 2 Spc. 3 Spc. 4 Spc. 5 Avg. Requirement For
Medical Face Mask (%)
Bacterial
Filtering 91.69 91.56 91.38 91.69 91.20 91.50 Type I: ≥95%
Efficiency (BFE)

Remarks:
1. Biological Aerosol: Staphylococcus aureus (ATCC 6538).
2. Testing side: Outside of the test specimen was facing towards the challenge aerosol.
3. Flow rate: 28.3 L/min
4. The average plate count results of the positive controls: 1636 CFU
5. The average plate count results of the negative controls: < 1 CFU
6. CFU = Colony Forming Unit

2. Differential Pressure
(EN 14683:2019+AC:2019 Annex C): Air flow: 8L/min, Test area diameter 25 mm, Test
area: 4.9 cm2):
Test Item Result (pa/cm2) Performance Requirement for
Medical Face Mask
Spc. 1 Spc. 2 Spc. 3 Spc. 4 Spc. 5
(pa/cm2)
Location 1 35.6 28.6 31.3 37.5 34.0
Location 2 28.6 31.0 31.1 35.4 36.3
Location 3 29.0 32.4 36.0 34.9 32.9
Type I <40
Location 4 29.3 34.0 32.4 36.0 35.6
Location 5 34.4 29.6 31.9 31.3 32.4
Average 31.4 31.1 32.5 35.0 34.2
* = All the locations were evenly taken from the main mask
body.

Page 4 of 6
ITS Labtest Bangladesh Ltd
Kabirpur, Ashulia, Savar, Dhaka-1349, Bangladesh, www.intertek.com
TEST REPORT NUMBER: BGDP21000171
DATE: 29-Sep-2021

(TESTS CONDUCTED (AS REQUESTED BY THE APPLICANT)


3. Sub Micron Particulate Filtration
(ASTM F2100-19ε1, Section 9.3, Testing Refer to ASTM F2299/F2299M-17): Particle size in
aerosol: 0.1 µm, Aerosol: PSL, Teat area: 100 cm2, Flowrate: 62.4 L/Min, Sampling time: 1 min.

Tested Particle Filtration Efficiency (%) Performance


Sample/Component Requirement for Medical
Face Mask (%)
Specimen 1 81.3 Type I: ≥95%

Specimen 2 85.2

Specimen 3 82.0

Specimen 4 81.2
Specimen 5 81.0
Average 82.1

4. Resistance To Penetration By Synthetic Blood


(Testing Refer to ISO 22609: 2004, Synthetic blood surface tension: 0.040 N/m, Distance
between blow head front end and target area: 300 mm,Artificial blood volumes: 2 mL, Test
Pressure: 80 mmHg, Velocity: 450 cm/s, Use a fixed target)

Test Specimen Result Remark


1. None Seen Pass
2. None Seen Pass
3. None Seen Pass
4. None Seen Pass
5. None Seen Pass
6. None Seen Pass
7. None Seen Pass
8. None Seen Pass
9. None Seen Pass
10. None Seen Pass
11. None Seen Pass
12. None Seen Pass
13. None Seen Pass
14. None Seen Pass
15. None Seen Pass
16 None Seen Pass
17. None Seen Pass
18. None Seen Pass
19. Seen Fail
Page 5 of 6
ITS Labtest Bangladesh Ltd
Kabirpur, Ashulia, Savar, Dhaka-1349, Bangladesh, www.intertek.com
TEST REPORT NUMBER: BGDP21000171
DATE: 29-Sep-2021

20. None Seen Pass


21. None Seen Pass
22. None Seen Pass
23. None Seen Pass
24. None Seen Pass
25. None Seen Pass
26. None Seen Pass
27. None Seen Pass
28. None Seen Pass
29. None Seen Pass
30. None Seen Pass
31. None Seen Pass
32. None Seen Pass
Number Of Failure: 01 (Within 4% AQL Acceptance
Limit)
Overall Conclusion (Pass At 80 mmHg)
(Level Type I)

## END OF THE TEST REPORT ##


This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any
particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Addressee in respect of this report and
only accepts liability to the Addressee insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek
makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to
conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract,
tort, by statute.For Terms and condition follow the link: http://www.intertek.com/terms.