You are on page 1of 12

Test Report No.

: U008094
Report Date : September 09, 2020
Page : 1 of 2

Client: Jolly Le
KIM DUC GROUP JOINT STOCK COMPANY
Unit 2704, Saigon Trade Center, 37 Ton Duc
Phone: 8(498) 781-0329
Email: thanhdanh@apicvietnam.com
Approval Date : August 18, 2020 Labeled Age Grade/Size : NA
Date of Receipt : August 18, 2020 Tested Age Grade : NA
Retest : No
# of Samples Submitted : 1 (set of 38)
Manufacturer's Name : Kim Duc Group Joint Stock Company- Long An Branch
Item Description : Isolation Surgical gown
Item Number : KD-GI-PPLam
Country of Origin : NA
Country of Import : NA
PO Number : NA
Delivery Conditions : Satisfactory, Samples tested as received

Testing Date Range : 08-18-2020 to 09-09-2020

The following test item(s) was/were performed on submitted sample(s) and/or component(s) confirmed by applicant

TEST REQUESTED RESULT


AAMI PB70 - Sample 1 - Level 2 (AATCC 127) Level 2 : 4 critical locations, chest, sleeve seam, back, tie attachment. (CIN008)** See Attachment
AAMI PB70 - Sample 1 - Level 2 (AATCC 42) Levels 2 : 4 critical locations: chest, Sleeve seam, back, tie attachment. (CIN008)** See Attachment
** Analysis completed by Eurofins Subcontract Laboratory

Signed for and on behalf of


Eurofins Product Testing US Inc.

Cristina Marquez / Project Manager

This report relates to the above mentioned test item(s) and the extent to tests performed. This test report is not permitted to be reproduced except in full, without written
permission of the test facility. This test report does not entitle any safety marks on this or similar products. The sample and the information regarding sample have been
provided by the client. All information related to the sample are under liability of the client and have not been checked by Eurofins Product Testing US Inc .

Eurofins Product Testing US Inc.


11822 North Creek Pkwy N., #110, Bothell, WA 98011
Phone: (425) 686-3575/Fax: (425) 686-3096 Web: www.EurofinsUS.com
Test Report No.: U008094
Report Date : September 09, 2020
Page : 2 of 2

ATTACHMENT
Page 1/5

Test Report

Sample Photo

Eurofins Product Testing India Pvt. Ltd., Plot No. 157, Udyog Vihar Phase- 1, Gurugram, Haryana-122016
Page 2/5

Test Report

APPLICANT :
Kim duc group joint stock company
CONTACT PERSON - :
ADDRESS :
Unit 2704, Saigon Trade Centre, 37 ton duc thang street, ben
: Nghe ward, district -1
Sample Not Drawn By Eurofins Product Testing India Pvt. Ltd.

Sample Description : Isolation surgical gown ( U008094 ± 01)


Buyer Name : -
Brand : -
Buying House : -
Style No : -
Item Number : KD-GI-PPLam
Fiber Content : -
Style No. : -
Colour Name : Blue ± Lab Identified
PO No. : Q1541187r3
ManXIDFWXUH¶V 1DPH : Kim duc group joint stock company ± Long an branch
Country of Origin : -
Country of Destination : -
Sample Receiving Date : 24 August 2020
Testing Period : 24 August 2020 to 07 September 2020
Delivery Condition : Sample received in good condition
$SSOLFDQW¶V 3URYLGHG &DUH ,QVWUXFWLRQ ODEHO : -

For and on behalf of


Eurofins Product Testing India Pvt. Ltd

Gadadhar Panda
Technical Executive
Results obtained refer only to samples, products or material received in Laboratory, as described in point related to sample description, and tested in conditions
shown in present report. Eurofins Products Testing Pvt. Ltd. Ensures that this job has been performed according to our Quality System and complying
contract and legal conditions. If you happen to have any comments, please do it by sending email to narenderarya@eurofins.com and referring to this report
number. Reproduction of this document is only valid if it is done completely and under the written permission Eurofins Products Testing Pvt. Ltd.

Eurofins Product Testing India Pvt. Ltd., Plot No. 157, Udyog Vihar Phase- 1, Gurugram, Haryana-122016
Page 3/5

Test Report

Conclusion:

Test Property Level 1 Level 2 Level 3 Level 4


Water Resistance t Impact Penetration Test M M M --
Water Resistance t Hydrostatic Pressure Test N/A M F --

M: Meets the requirements of ANSI/AAMI PB 70


F: Does not meet the requirements of ANSI/AAMI PB 70
N/A: Not Applicable
Remark: Testing has been performed as per applicant request

Note:
If there is question or concern regarding the above results, please contact the appropriate lab person below:

Amit Saluja
amitsaluja@eurofins.com
Or
Narender Arya
General Manager (India Business)
narenderarya@eurofins.com
The testing lab overall rating is provided to client as an aid in reviewing report data. The rating is based on lab results. Final product acceptance
}Œ Œ i š]}v ]• ‰ Œ o] vš }voÇX d •š]vP }( À v }Œ[• u Œ Z v ]• Ç o] vš ]• v}š •µ •š]šµš (}Œ À v }Œ[• }Áv š •š]vP v }šZ Œ ‹µ o]šÇ ••µŒ v
Œ o š } o]P š]}v• ]v }vv š]}v Á]šZ ]š• • o }( u Œ Z v ]• š} o] všX o] vš š •š]vP •Z oo v}š o]u]š o] vš[• Œ]PZš•U }Œ diminish or remove any of
À v }Œ[• Œ •‰}v•ibilities.

Eurofins Product Testing India Pvt. Ltd., Plot No. 157, Udyog Vihar Phase- 1, Gurugram, Haryana-122016
Page 4/5

Test Report

Component List:

Sample No Component Material Description Color Remarks


001 Isolation surgical gown - Blue±lab Identified -

Water Resistance t Impact Penetration Test*


AATCC 42:2017
SAMPLE Increase in mass of Blotter (grams) Requirement
001 Chest Sleeve seam Tie attachment Back
Sample 1 0 0 0.2 0
Sample 2 0 0 0 0
Sample 3 0 0 0 0
Sample 4 0 0 0 0
Sample 5 0 0 0 0
Sample 6 0 0 0 0
Sample 7 0 0 0 0
Sample 8 0 0 0 0
Sample 9 0 0 0 0
Sample 10 0 0 0 0
Sample 11 0 0 0 0
Sample 12 0 0 0 0
Sample 13 0 0 0 0
Sample 14 0 0 0 0
Sample 15 0 0 0 0 Level 1: ” J
Sample 16 0 0 0 0 Level 2: ” J
Sample 17 0 0 0 0 Level 3: ” J
Sample 18 0 0 0 0
Sample 19 0 0 0 0
Sample 20 0 0 0 0
Sample 21 0 0 0 0
Sample 22 0 0 0 0
Sample 23 0 0 0 0
Sample 24 0 0 0 0
Sample 25 0 0 0 0
Sample 26 0 0 0 0
Sample 27 0 0 0 0
Sample 28 0 0 0 0
Sample 29 0 0 0 0
Sample 30 0 0 0 0
Sample 31 0 0 0 0
Sample 32 0 0 0 0

Eurofins Product Testing India Pvt. Ltd., Plot No. 157, Udyog Vihar Phase- 1, Gurugram, Haryana-122016
Page 5/5

Test Report

Water Resistance t Hydrostatic Pressure Test*


AATCC 127:2018 (@60 mbr /min)
SAMPLE Result (cmH2O) Requirement
001 Chest Sleeve seam Tie attachment Back
Sample 1 254.0 82.5 39.6 183.7
Sample 2 231.0 64.8 42.1 285.0
Sample 3 239.3 74.3 67.8 255.7
Sample 4 250.0 59.1 43.6 245.7
Sample 5 256.7 51.0 50.1 242.1
Sample 6 268.0 50.4 38.2 260.0
Sample 7 235.0 53.0 30.2 251.3
Sample 8 253.0 49.6 43.6 264.0
Sample 9 229.0 42.3 47.2 249.1
Sample 10 248.1 50.1 41.2 238.7
Sample 11 264.1 75.2 36.6 251.0
Sample 12 262.0 41.4 31.9 243.1
Sample 13 239.1 69.1 38.8 231.7
Sample 14 211.3 53.7 42.2 220.0
Sample 15 235.1 64.3 26.7 169.6
/HYHO • FP
Sample 16 166.2 68.1 42.3 171.6
Level 3: • cm
Sample 17 264.3 59.1 40.6 182.3
Sample 18 234.1 58.2 22.7 176.6
Sample 19 240.4 51.2 29.1 191.7
Sample 20 253.0 50.6 31.6 200.3
Sample 21 228.3 47.3 36.7 210.6
Sample 22 274.1 39.6 40.6 200.2
Sample 23 229.4 42.3 44.1 210.4
Sample 24 267.0 72.8 30.5 216.6
Sample 25 276.0 81.8 21.7 200.7
Sample 26 251.4 77.8 51.6 186.6
Sample 27 234.8 91.2 40.3 189.1
Sample 28 269.1 81.2 35.4 193.7
Sample 29 230.3 70.6 30.7 175.1
Sample 30 241.8 52.3 12.8 207.6
Sample 31 232.7 81.2 13.9 210.1
Sample 32 266.6 58.7 37.0 200.7

*Note: - Above tests has been subcontracted with Eurofins approved lab.

*****End of Report*****

Eurofins Product Testing India Pvt. Ltd., Plot No. 157, Udyog Vihar Phase- 1, Gurugram, Haryana-122016
Report No. : 590-2020-08000116-2
Date : September 14, 2020
Page : 1 of 5

KIM DUC GROUP JOINT STOCK COMPANY.


Unit 2704, Saigon Trade Center, 37 Ton Duc Thang Street, Ben Nghe Ward, District 1, Ho Chi Minh
City, Vietnam.

Test Report
SAMPLING: Sample Not Drawn By Eurofins Consumer Product Testing Vietnam Co. Ltd
SAMPLE DESCRIPTION: Isolation Surgical gown
STYLE NO.: KD-GI-PPLam
MANUFACTURER: Kim Duc Group Joint Stock Company- Long An Branch
COUNTRY OF ORIGIN: Vietnam

EXPORT TO: EU / USA / Canada

DELIVERY CONDITION: Sample Received in Good Condition

RECEIVED ON: 18/08/2020

TESTING PERIOD: 18/08/2020 – 09/09/2020

Eurofins Consumer Product Testing Vietnam Company Limited


1/4 Tan Thoi Nhat 18 Street, Tan Thoi Nhat Ward, District 12, Ho Chi Minh City, Vietnam.
Tel: +84 287109 8828 Website: https://www.eurofins.com/cpt
Report No. : 590-2020-08000116-2
Date : September 14, 2020
Page : 2 of 5

RESULT SUMMARY

# TEST REQUESTED PASS FAIL DATA


1 Breaking Strength Of Textile Fabrics X
2 Tearing Strength X
3 Seam Strength X
4 Fabric Weight X
5 Flammability of Textiles X

Pass – Meets Performance Standard


Fail – Fails to Meet Performance Standard

************ FOR FURTHER DETAILS, PLEASE REFER TO THE FOLLOWING PAGE(S) *************

This test report has been validated by;

____________
Henry Nguyen
Lab Operation Manager

Results obtained refers to the samples, products or materials received in the Laboratory, as described in above related sample description, and
tested in conditions shown in present report. Eurofins Consumer Product Testing Vietnam Co., Ltd. ensures that this job has been performed
according to our Quality System and complying contract and legal conditions. Reproduction of this document is only valid if it is done completely
and under the written permission of Eurofins Consumer Product Testing Vietnam Co., Ltd. If you have any comments or complaints, please
response by sending an email to AngelaLe@eurofins.com and referring to this report number.

Eurofins Consumer Product Testing Vietnam Company Limited


1/4 Tan Thoi Nhat 18 Street, Tan Thoi Nhat Ward, District 12, Ho Chi Minh City, Vietnam.
Tel: +84 287109 8828 Website: https://www.eurofins.com/cpt
Report No. : 590-2020-08000116-2
Date : September 14, 2020
Page : 3 of 5

SAMPLE PHOTO

Eurofins Consumer Product Testing Vietnam Company Limited


1/4 Tan Thoi Nhat 18 Street, Tan Thoi Nhat Ward, District 12, Ho Chi Minh City, Vietnam.
Tel: +84 287109 8828 Website: https://www.eurofins.com/cpt
Report No. : 590-2020-08000116-2
Date : September 14, 2020
Page : 4 of 5

TEST RESULT

BREAKING STRENGTH OF TEXTILE FABRICS


Test Method: ASTM D5034: 2009 (2013)

Parameter Unit Result Requirement

WARP lbf 17.5 /

FILLING lbf 22.5 /

TEARING STRENGTH
Test Method: ASTM D5587

Parameter Unit Result Requirement

WARP lbf 6.0 /

FILLING lbf 8.7 /

SEAM STRENGTH
Test Method: ASTM D751

Parameter Unit Result Requirement

Arm Hole lbf 25.7 /

Sleeve lbf 23.1 /

Shoulder lbf 20.4 /

FABRIC WEIGHT
Test Method: ASTM D3776

Result Requirement
G / M2 45.4 /
OZ/YD2 1.34

Eurofins Consumer Product Testing Vietnam Company Limited


1/4 Tan Thoi Nhat 18 Street, Tan Thoi Nhat Ward, District 12, Ho Chi Minh City, Vietnam.
Tel: +84 287109 8828 Website: https://www.eurofins.com/cpt
Report No. : 590-2020-08000116-2
Date : September 14, 2020
Page : 5 of 5

TEST RESULT
FLAMMABILITY OF TEXTILES
Test Method: CPSC 16 CFR 1610:2011

Result Requirement:

If sample falls under specific exemptions as


Listed below, the report should be rated as a
Pass and the specific exemption should be noted in the
report.
Exempt due to fiber content: polyester
The submitted sample(s) is(are) exempt from
Flammability testing in accordance with 16 CFR
1610.1(d) which states:
Specific exemptions
Experience gained from years of testing in
Accordance with the standard demonstrates that certain
fabrics consistently yield acceptable results when tested in
accordance with the standard. Therefore, persons and firms
Main body issuing an initial guaranty of any of the following types of Class 1
fabrics, or of products made entirely from one or more of
these fabrics are exempt from any requirement for testing to
support
Guaranties of those fabrics.
1. Plain surface fabrics, regardless of
Fiber content, weighing 2.6 ounces per square
Yard or more; and
2. All fabrics, both plain surface and
Raised-fiber surface, regardless of weight,
Made entirely from any of the following fibers
Or entirely from combination of the following
Fibers: acrylic, modacrylic, nylon, olefin,
Polyester, wool.

*** END OF THE REPORT ***

Eurofins Consumer Product Testing Vietnam Company Limited


1/4 Tan Thoi Nhat 18 Street, Tan Thoi Nhat Ward, District 12, Ho Chi Minh City, Vietnam.
Tel: +84 287109 8828 Website: https://www.eurofins.com/cpt

You might also like