TEST REPORT

No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 1 of 6

CUSTOMER NAME: XIAMEN EMPERY SOLAR TECHNOLOGY CO., LTD


ADDRESS: ROOM 611, NO.368, QUANYUTONG BUSINESS CENTER, HULI
DISTRICTS, XIAMEN, CHINA.

Sample Name : HIGH DENSITY POLYETHYLENE


Above information and sample(s) was/were submitted and confirmed by the client. SGS, however,
assumes no responsibility to verify the accuracy, adequacy and completeness of the sample
information provided by client.
***********
SGS Ref. No. : GZMR220902924201
Date of Receipt : 2022-09-13
Testing Start Date : 2022-09-13
Testing End Date : 2022-09-21
Test result(s) : For further details, please refer to the following page(s)
(Unless otherwise stated the results shown in this test report refer only
to the sample(s) tested)

Signed for
SGS-CSTC Standards Technical
Services Co.,Ltd. Xiamen Branch.

Jude Zhao
Authorized signatory
TEST REPORT
No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 2 of 6

Summary of Results:
No. Test Item Test Method Result
Tensile Strength 23.6MPa
1 Tensile Test ASTM D638-14
Elongation at Break 120%
2 Tensile Modulus ASTM D638-14 1200MPa
TEST REPORT
No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 3 of 6

1.Test Item: Tensile Test


Sample Description: Plastic part
Test Method: ASTM D638-14
Test Condition:
Specimen: Type Ⅰ
Specimen thickness: 3.73mm
Testing speed: 50mm/min
Gauge length: 50mm
Distance between grips: 115mm
Lab Environmental Condition: 23 ± 2 ℃, 50 ± 5 % RH
Test Result:

Test Item Test Result

Tensile Strength 23.6MPa

Elongation at Break 120%( See Table 1)

Table 1:

Specimen #1 #2 #3 #4 #5 #6 #7

Elongation at Break, % 263 92.3 130 101 63.7 164 56.7

Note: Test specimens were cut from the sample.


TEST REPORT
No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 4 of 6

Test Photo:

Original sample A During Test

Before Test After Test

Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Universal Testing
Z030 GZMR-PL-E140 2022-06-21 2023-06-20
Machine
TEST REPORT
No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 5 of 6

2.Test Item: Tensile Modulus


Sample Description: Plastic part
Test Method: ASTM D638-14
Test Condition:
Specimen: Type Ⅰ
Specimen thickness: 3.73mm
Testing speed: 5mm/min
Gauge length: 50mm
Distance between grips: 115mm
Lab Environmental Condition: 23 ± 2 ℃, 50 ± 5 % RH
Test Result:

Test Item Test Result

Tensile Modulus 1200MPa

Note: Test specimens were cut from the sample.

Test Photo:

Original sample A
TEST REPORT
No. : XMIN22000158PL01_EN
Date : 2022-09-21
Page: 6 of 6

During Test Before Test

Equipment Information:
Next Calibration
Equipment Model Equipment No. Calibration date
date
Universal Testing
Z030 GZMR-PL-E140 2022-06-21 2023-06-20
Machine
Note: The above test project/method was carried out by subcontractors.
********End of report********