INSPECTION REPORT
Po No:17TRE-137 PI
Report No: 18/01002 Report Date:2018-01-02
A.4 Inspection samples were selected from the following shipping carton no.: Total 16 cartons
Randomly selected 16cartons for inspection
Page 1 of 4
CYF.INSPECTION REPORT
Po No:17TRE-137 PI
Report No: 18/01002 Report Date:2018-01-02
1. Function Checking
Checking Criteria : 110 Vac at 60 Hz power supply
Sample Size : Full Sample Size
Result : PASSED
2. Hi-Pot Tests
Checking Criteria : 1500Vac for 3 seconds at 5mA [for Class II appliances]
Sample Size : Full Sample Size
Result : REMARK
5. Plug Type,
Plug Type : Two falt pin plug
Strand Colour : N/a
8. Burn-in Test
Testing Period : Continuously operated the samples for 4 hours
Test Voltage : 121 Vac as increased 10% of rated voltage 110 Vac.
Sample Size : 5 piece
Result : PASSED
Page 2 of 4
CYF.INSPECTION REPORT
Po No:17TRE-137 PI
Report No: 18/01002 Report Date:2018-01-02
Rating Label
3. Shipping Mark:
Page 3 of 4
CYF.INSPECTION REPORT
Po No:17TRE-137 PI
Report No: 18/01002 Report Date:2018-01-02
G. Samples Collection:
- N/A pieces of Shipment Sample
- N/A pieces of Defective Sample
- N/A pieces of gift box or other:
- Reason of no sample:
The above reflects our findings at time and place of inspection. This report does not relieve
sellers /suppliers from their contractual with regard to quantity and quality of this delivery. This
report is issued without prejudice to liability and the information contained herein is to the best of
our knowledge and belief, true and correct.
********************************* END OF REPORT ************************************