AC LOAD CALCULATION
B-848
VARD ELECTRO AS
TRANSIT TRANSIT FAST TRANSIT SAFE RETURN TO SAFE RETURN TO PORT
HARBOUR OPERATION HARBOUR OPERATION MANOEUVERING STAND BY
EMERGENCY OPERATION SUMMER MODE WINTER MODE MODE PORTDMG to MVZ2 DMG to MVZ1
WINTER SUMMER MODE MODE
(speed 12,5kn) (speed 12,5kn) (speed 15kn) (speed 6kn) (speed 6kn)
Supplied Trafo Size Trafo Size Load Load Load Load Load Load Load Load
From Trafo kVA kW (kW) (kW) (kW) (kW) (kW) (kW) (kW) (kW)
CONSUMERS (Includes loads from distribution transformer under each MSB)
690V MAIN SWITCHBOARDS A (IT) 738,30 677,52 2293,65 2202,66 2213,24 2436,35 1500,46 0,00 2683,84
690V MAIN SWITCHBOARDS B (IT) 500,68 471,60 1498,87 2141,77 2009,43 2263,85 1180,47 2706,41 895,99
690V ACC MVZ2 (IT) 100,09 88,87 136,71 208,14 142,19 136,62 130,29 0,00 242,46
690V ACC MVZ3 (IT) 36,51 38,25 55,67 84,70 62,35 61,17 57,10 89,54 59,86
690V ACC MVZ1 (IT) 115,65 114,48 191,55 253,67 209,78 189,55 182,36 243,80 6,43
230/127V ACC MVZ2 (TNS) No.6 & 7 315 284 BUREAU VERITAS 100,09
35,3 % 88,87 31,3 % 136,71 48,2 % 208,14 73,4 % 142,19 50,2 % 136,62 48,2 % 130,29 46,0 % 0,00 0,0 % 242,46 85,5 %
230/127V ACC MVZ3 (TNS) No.8 & 9 315 284 36,51
12,9 % 38,25 13,5 % 55,67 19,6 % 84,70 29,9 % 62,35 22,0 % 61,17 21,6 % 57,10 20,1 % 89,54 31,6 % 59,86 21,1 %
230/127V ACC MVZ1 (TNS) No.10 & 11 315 284 Stamped document, refer to 1st page 31,4 %
89,14 87,97 31,0 % 113,83 40,2 % 160,75 56,7 % 119,99 42,3 % 116,91 41,2 % 112,51 39,7 % 198,83 70,1 % 6,43 2,3 %
400V GALLEY/LAUNDRY SWBD (TNS) No.3 (& 4) 630 567 279,62 49,3 % 216,74 38,2 % 285,11 50,3 % 334,14 58,9 % 353,68 62,4 % 313,06 55,2 % 288,84 50,9 % 0,00 0,0 % 371,06 65,4 %
230V GALLEY/LAUNDRY SWBD (TNS) No. 4 (& 3) 630 567 89,68 15,8 % 89,87 15,9 % 98,70 17,4 % 101,44 17,9 % 101,32 17,9 % 101,32 17,9 % 98,76 17,4 % 0,00 0,0 % 101,20 17,8 %
230V GENERAL CONSUMERS A (IT) No. 1 400 360 37,74 10,5 % 36,41 10,1 % 38,17 10,6 % 38,32 10,6 % 40,28 11,2 % 38,41 10,7 % 38,17 10,6 % 0,00 0,0 % 47,93 13,3 %
230V GENERAL CONSUMERS B (IT) No. 2 400 360 36,83 10,2 % 18,00 5,0 % 38,03 10,6 % 38,03 10,6 % 38,03 10,6 % 38,03 10,6 % 38,03 10,6 % 47,58 13,2 % 53,90 15,0 %
EMERGENCY SWBD 690V (Em.Gen) 938 750 669,89 287,68 38,3 % 286,03 38,1 % 289,13 38,5 % 298,86 39,8 % 300,31 40,0 % 303,08 40,4 % 275,68 36,7 % 0,00 0,0 % 269,68 35,9 %
EMERGENCY SWBD 230V No. 12 & 13 200 180 123,39 8,33 4,6 % 8,33 4,6 % 9,78 5,4 % 16,01 8,9 % 17,46 9,7 % 16,01 8,9 % 8,33 4,6 % 0,00 0,0 % 13,13 7,3 %
TOTAL LOAD MSB 1238,98 1149,12 3792,53 4344,42 4222,66 4700,20 2680,93 2706,41 3579,83
TOTAL LOAD ESB 669,89
TOTAL LOAD HOTEL 552,55 44,6 % 511,11 44,5 % 766,34 20,2 % 1076,44 24,8 % 817,16 19,4 % 778,47 16,6 % 745,84 27,8 % 669,30 24,7 % 719,31 20,1 %
TOTAL LOAD SHIP 686,43 55,4 % 638,01 55,5 % 3026,19 79,8 % 3267,98 75,2 % 3405,50 80,6 % 3921,74 83,4 % 1935,09 72,2 % 2037,11 75,3 % 2860,52 79,9 %
Side 2 av 20
690V MAIN SWITCHBOARDS A (IT)
VARD ELECTRO AS HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
690V MAIN SWITCHBOARDS A (IT)
CELL +VAA1 - CONSUMERS 690V
Q1 3 Auxilary Boiler 1CP1 30,6 0,8 20 % 4,9 10 % 2,4 50 % 12,2 40 % 9,8 80 % 19,6 50 % 12,2 50 % 12,2 0% 0,0 50 % 0,5
Q2 3 Steam Drum & Exhaust Gas Boiler 1CP2 19,1 0,8 20 % 3,1 10 % 1,5 50 % 7,6 40 % 6,1 80 % 12,2 50 % 7,6 50 % 7,6 0% 0,0 50 % 0,3
Q3 3 Water Mist Master Pump Unit A 193,0 0,8 10 % 15,4 10 % 15,4 10 % 15,4 10 % 15,4 10 % 15,4 10 % 15,4 10 % 15,4 0% 0,0 50 % 77,2
Q4 3 HP03 - 690 V High Power Distribution Panel(Power via changeover) 24,7 0,9 0% 0,0 0% 0,0 52% 14,9 56% 11,2 56 % 11,2 56% 11,2 12% 1,0 0% 0,0 56% 11,2
Q5 3 HP04 - 690 V High Power Distribution Panel BUREAU VERITAS
56,1 1,0 4% 1,7 4% 1,7 48% 22,5 40% 22,5 40 % 22,5 41% 23,4 14% 7,8 0% 0,0 38% 20,9
Q6 3 Spare
Q7 3 Spare Stamped document, refer to 1st page
Q8 3 Spare
Q9 3 Spare
Q10 3 Pre-Heating Unit, ME 1 & 2 36,0 1,0 50 % 18,0 10 % 3,6 25 % 9,0 10 % 3,6 50 % 18,0 10 % 3,6 25 % 9,0 0% 0,0 50 % 18,0
Q11 3 Aux Supply Main Propulsion Drive A 120,0 0,9 0% 0,0 0% 0,0 25 % 27,0 0% 0,0 0% 0,0 0% 0,0 25 % 27,0 0% 0,0 0% 0,0
Q12 3 Spare
Q13 3 Spare
Q14 3 Spare
Q15 3 Spare
Q16 3 Spare
CELL +VAA2 - CONSUMERS 690V
Q1 3 Spare
Q2 3 GSP-03 Group Starter Panel MVZ-2 128,0 0,8 10% 9,5 15% 15,6 42% 43,9 45% 44,9 31 % 30,4 31% 30,4 15% 16,1 0% 0,0 50% 47,6
Q3 3 Life Boat Davit SB 31,0 0,8 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q4 3 Rescue Boat Davit SB 15,0 0,8 5% 0,6 5% 0,6 30 % 3,6 0% 0,0 0% 0,0 0% 0,0 30 % 3,6 0% 0,0 30 % 3,6
Q5 3 Anti Heeling Pump 22,0 0,8 0% 0,0 0% 0,0 30 % 5,3 50 % 8,8 50 % 8,8 70 % 12,3 30 % 5,3 0% 0,0 30 % 5,3
Q6 3 Zodiac Crane PS 37,0 0,8 0% 0,0 0% 0,0 30 % 8,9 0% 0,0 0% 0,0 0% 0,0 30 % 8,9 0% 0,0 0% 0,0
Q7 3 Hvac Starter Cabinet (576.12802.92) 78,5 1,0 30 % 23,6 30 % 23,6 30 % 23,6 50 % 39,3 50 % 39,3 50 % 39,3 50 % 39,3 0% 0,0 50 % 39,3
Q8 3 Hvac Starter Cabinet (576.32106.92) 68,1 1,0 30 % 20,4 30 % 20,4 30 % 20,4 50 % 34,1 50 % 34,1 50 % 34,1 50 % 34,1 0% 0,0 50 % 34,1
Q9 3 Ballast Treatment Unit 22,2 0,8 10 % 1,8 10 % 1,8 20 % 3,6 50 % 8,9 20 % 3,6 20 % 3,6 10 % 1,8 0% 0,0 50 % 8,9
Q10 3 Mooring Winch 1 Aft PS 30,0 0,8 0% 0,0 0% 0,0 50 % 12,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q11 3 Mooring Winch 2 Aft PS 30,0 0,8 0% 0,0 0% 0,0 50 % 12,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q12 3 EVAC AWP Common Cabinet 44,4 0,8 10 % 3,6 10 % 3,6 20 % 7,1 50 % 17,8 20 % 7,1 20 % 7,1 10 % 3,6 0% 0,0 50 % 17,8
Q13 3 EVAC MBR 95K N Sewage Treatment 38,2 0,8 10 % 3,1 10 % 3,1 20 % 6,1 50 % 15,3 20 % 6,1 20 % 6,1 10 % 3,1 0% 0,0 50 % 15,3
Q14 3 Windlass Winch PS 37,0 0,8 0% 0,0 0% 0,0 50 % 14,8 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q15 3 Spare
Q16 3 Spare
CELL +VAA3 -CONSUMERS 690V
Q1 3 Spare
Q2 3 Chilled Water Compressor Unit No.1 200,0 0,8 5% 8,0 10 % 16,0 50 % 80,0 50 % 80,0 50 % 80,0 30 % 48,0 50 % 80,0 0% 0,0 50 % 80,0
Q3 3 Chilled Water Compressor Unit No.2 200,0 0,8 5% 8,0 10 % 16,0 50 % 80,0 50 % 80,0 50 % 80,0 30 % 48,0 50 % 80,0 0% 0,0 50 % 80,0
Q4 3 Spare
Q5 3 GSP-02 Group Starter Panel MVZ-2 132,6 0,6 11% 11,7 15% 13,0 30% 26,1 35% 31,6 27 % 28,6 30% 28,6 17% 21,4 0% 0,0 50% 47,3
Q6 3 Spare
Q7 3 Spare
Q8 3 Spare
Q9 3 Spare
Q10 3 Spare
Q11 3 Spare
Q12 3 Distribution Transformer No.1 690/230V 400kVA
CELL +VAA4 - SPARE CELL
.
690V MAIN SWITCHBOARDS B (IT)
VARD ELECTRO AS HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
690V MAIN SWITCHBOARDS B (IT)
CELL +VBA1 - BUS-TIE B
Q1 3 BUS-TIE B 2000A
.
690V ACC MVZ1 (IT)
VARD ELECTRO AS HARBOUR TRANSIT
HARBOUR TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
690V ACC MVZ1 (IT)
CELL +VBE1 - FEEDING LINE FROM MSB 690V
Q1 3 690V Bus Tie To ACC DB 1
.
230/127V ACC MVZ1 (TNS)
CELL +VBE3 - SEC. TRANS. NO.10/NO.11
Q1 3 Distribution Transformer No.10 690/230V 315kVA
Q2 3 Distribution Transformer No.11 690/230V 315kVA
.
690V ACC DB 2 (IT)
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
690V ACC MVZ2 (IT)
CELL +VAD1 - CONSUMERS 690V
Q1 3 MSB 690V A PS (MAIN) / MSB 690V B SB (BACK UP)
.
230/127V ACC MVZ2 (TNS)
CELL +VAD3 - SEC. TRANS. NO.6/NO.7MERS 690V
Q1 3 Distribution Transformer No.6 690/230V 315kVA
Q2 3 Distribution Transformer No.7 690/230V 315kVA
.
690V ACC DB 3 (IT)
VARD ELECTRO AS HARBOUR TRANSIT
HARBOUR TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
690V ACC MVZ3 (IT)
CELL +VBD1 - FEEDING LINE FROM MSB 690V
Q1 3 MSB 690V A PS (MAIN) / MSB 690V B SB (BACK UP)
.
230/127V ACC MVZ3 (TNS)
CELL +VBD3 - SEC. TRANS. NO.8/NO.9
Q1 3 Distribution Transformer No.8 690/230V 315kVA
Q2 3 Distribution Transformer No.9 690/230V 315kVA
.
GALLEY LAUNDRY SWBD (TNS)
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
400V GALLEY/LAUNDRY SWBD (TNS)
CELL +VAB1 - CONSUMERS 400V +N
Q1 3 Distribution Transformer No.3 690/400V 630kVA
Q2 3 Distribution Transformer No.4 690/230V 630kVA
Q3 3 Spare
Q4 3 Spare
Q5 3 Spare BUREAU VERITAS
Q6 3 Spare
Q7 3 Spare
Stamped document, refer to 1st page
Q8 3 Spare
Q9 3 Spare
Q10 3 Spare
Q29 3 MP01 - 400 V Medium Power Distribution Panel 63,9 0,6 80% 43,4 80% 43,4 70% 38,0 80% 43,4 80% 43,4 70% 38,0 70% 38,0 0% 0,0 100% 54,3
Q6 3 MP02 - 400 V Medium Power Distribution Panel 28,4 0,9 80% 21,9 80% 21,9 70% 19,2 80% 21,9 80% 21,9 70% 19,2 70% 19,2 0% 0,0 100% 27,4
Q6 3 MP03 - 400 V Medium Power Distribution Panel 52,0 0,9 69% 30,8 50% 21,8 63% 28,0 69% 30,8 80% 36,2 63% 28,0 63% 28,0 0% 0,0 81% 36,2
Q6 3 MP04 - 400 V Medium Power (Main Laundry) Distribution Panel 65,1 1,0 80% 51,3 53% 32,1 70% 44,9 80% 51,3 80% 51,3 70% 44,9 70% 44,9 0% 0,0 100% 64,1
Q6 3 MP05 - 400 V Medium Power Distribution Panel 16,0 0,8 80% 11,4 40% 1,8 70% 9,9 80% 11,4 80% 11,4 70% 9,9 70% 9,9 0% 0,0 100% 14,2
Q6 3 MP06 - 400 V Medium Power Distribution Panel 38,0 0,9 80% 29,6 11% 0,8 80% 29,6 46% 15,2 97% 36,8 80% 29,6 80% 29,6 0% 0,0 80% 29,6
.
GALLEY LAUNDRY SWBD (TNS)
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
400V GALLEY/LAUNDRY SWBD (TNS)
230V
CELL +VBB1 - CONSUMERS 230/127V +N
Q1 3 Distribution Transformer No.4 690/230V 630kVA
Q2 3 Distribution Transformer No.3 690/400V 630kVA
Q3 3 Spare
Q4 3 Spare
Q5 3 Spare
BUREAU VERITAS
Q6 3 Spare Stamped document, refer to 1st page
Q7 3 Spare
Q8 3 Spare
Q9 3 Spare
Q10 3 Spare
.
230V GENERAL CONSUMERS (IT)
VARD ELECTRO AS HARBOUR TRANSIT
HARBOUR TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
230V GENERAL CONSUMERS A (IT)
CELL +VAC1 - TRANSFORMER NO.1
Q1 3 Distribution Transformer No.1 690/230V 400kVA
.
230V GENERAL CONSUMERS B (IT)
CELL +VBC1 - TRANSFORMER NO.2
Q1 3 Distribution Transformer No.2 690/230V 400kVA
.
690V EMERGENCY SWBD
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph Consumer Description P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
EMERGENCY SWBD 690V
CELL +VAE1 - EMERGENCY GENERATOR
Q1 3 Em.Generator 690V 938kVA
Em. 546,5kW 279,4kW 277,7kW 279,4kW 282,9kW 282,9kW 287,1kW 267,4kW 0,0kW 256,6kW
TOTAL EMERGENCY SWBD 690V: 775,0
Gen. 70,5 % 36,0 % 35,8 % 36,0 % 36,5 % 36,5 % 37,0 % 34,5 % 0,0 % 33,1 %
.
Side 15 av 20
230V EMERGENCY SWBD
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
EMERGENCY SWBD 230V
CELL +VAF1 - FEEDING LINE FROM MSB 690V
Q1 3 WTD MVZ1 Deck 2 4,0 1,0 100 % 4,0 0% 0,0 0% 0,0 0% 0,0 20 % 0,8 20 % 0,8 20 % 0,8 0% 0,0 0% 0,0 0% 0,0
Q2 3 WTD MVZ2 Deck 2 4,0 1,0 100 % 4,0 0% 0,0 0% 0,0 0% 0,0 20 % 0,8 20 % 0,8 20 % 0,8 0% 0,0 0% 0,0 0% 0,0
Q3 3 WTD MVZ3 Deck 2 4,0 1,0 100 % 4,0 0% 0,0 0% 0,0 0% 0,0 20 % 0,8 20 % 0,8 20 % 0,8 0% 0,0 0% 0,0 0% 0,0
Q4 3 Spare BUREAU VERITAS
Q5 3 Spare
Q6 3 UPS No.1 For IAS System Stamped document,
4,0 refer100to% 1st page
1,0 4,0 10 % 0,4 10 % 0,4 10 % 0,4 20 % 0,8 20 % 0,8 20 % 0,8 10 % 0,4 0% 0,0 20 % 0,8
Q7 3 UPS No.2 For IAS System 4,0 1,0 100 % 4,0 10 % 0,4 10 % 0,4 10 % 0,4 20 % 0,8 20 % 0,8 20 % 0,8 10 % 0,4 0% 0,0 20 % 0,8
Q8 3 UPS No.3 For IAS System 4,0 1,0 100 % 4,0 10 % 0,4 10 % 0,4 10 % 0,4 20 % 0,8 20 % 0,8 20 % 0,8 10 % 0,4 0% 0,0 20 % 0,8
Q9 3 Spare
Q10 3 Water Mist Comm. Cabinet AX1.1 0,5 1,0 100 % 0,5 50 % 0,3 50 % 0,3 50 % 0,3 50 % 0,3 50 % 0,3 50 % 0,3 50 % 0,3 0% 0,0 50 % 0,3
Q11 3 Water Mist I/O Cabinet 1.1 1,3 1,0 100 % 1,3 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 0% 0,0 50 % 0,7
Q12 3 Water Mist I/O Cabinet 1.2 1,3 1,0 100 % 1,3 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 50 % 0,7 0% 0,0 50 % 0,7
Q13 3 Spare
Q14 3 Spare
Q15 3 Spare
Q16 3 Spare
Q17 3 Spare
Q18 3 Spare
Q19 3 ELP01- 230 V Emergency Low Power Distribution Panel 3,0 1,0 100% 1,7 50% 0,9 50% 0,9 50% 1,5 50% 0,9 50% 1,5 50% 0,9 50% 0,9 0% 0,0 50% 0,9
Q20 3 ELP03- 230 V Emergency Low Power Distribution Panel 3,5 1,0 100% 2,0 50% 1,0 50% 1,0 50% 1,7 50% 1,0 50% 1,7 50% 1,0 50% 1,0 0% 0,0 50% 1,0
Q21 3 ELP02 - 230 V Emergency Low Power Distribution Panel 0,4 1,0 100% 0,2 50% 0,1 50% 0,1 50% 0,2 50% 0,1 50% 0,2 50% 0,1 50% 0,1 0% 0,0 50% 0,1
Q22 3 Spare
Q23 3 Spare
Q24 3 Transformer No 12 - 690V\230V 200,0
Q25 3 Transformer No 13 - 690V\230V 200,0
Side 16 av 20
230V EMERGENCY SWBD
VARD ELECTRO AS
HARBOUR HARBOUR TRANSIT TRANSIT SAFE RETURN TO SAFE RETURN TO
EMERGENCY MANOEUVERING FAST TRANSIT STAND BY
OPERATION OPERATION SUMMER WINTER PORT PORT
OPERATION MODE MODE MODE
WINTER SUMMER MODE MODE DMG TO MVZ2 DMG TO MVZ1
Consumer L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load L.F. Load
Breaker Ph P.F.
(kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW) (%) (kW)
EMERGENCY
CELL SWBD 230V
+VAF3 - CONSUMERS UPS 230V
Q1 3 TUPS01 - 230 V Transitional UPS Distribution Panel 2,9 1,0 100% 1,7 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q2 3 TUPS02 - 230 V Transitional UPS (Internal & External) Distribution Panel 8,3 1,0 100% 4,8 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q3 3 TUPS03 - 230 V Transitional UPS (Internal & External) Distribution Panel 8,1 1,0 100% 4,7 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q4 3 TUPS04 - 230 V Transitional UPS Distribution Panel 9,9 1,0 100% 5,7 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q5 3 TUPS06 - 230 V Transitional UPS Distribution Panel BUREAU VERITAS
6,9 1,0 100% 4,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q6 3 TUPS07 - 230 V Transitional UPS Distribution Panel 6,5 1,0 100% 3,4 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q7 3 TUPS08 - 230 V Transitional UPS Distribution Panel Stamped document, refer to 1st page
18,0 1,0 100% 10,4 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q8 3 TUPS09 - 230 V Transitional UPS Distribution Panel 6,4 1,0 100% 3,7 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q9 3 LP02 - 230 V Low Power (SRTP) Distribution Panel 1,8 1,0 100% 1,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q10 3 TUPS05 - 230 V Transitional UPS Distribution Panel 5,8 1,0 100% 3,4 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q11 3 LP10 - 230 V Low Power Distribution Panel 19,48 1,0 100% 11,2 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q12 3 NAVIGATION LIGHT CONTROLER 1 MAIN UNIT 2,0 1,0 100% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
Q13 3 NAVIGATION LIGHT CONTROLER 2 SRtP UNIT 2,0 1,0 100% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0 0% 0,0
123,4kW 8,3kW 8,3kW 9,8kW 16,0kW 17,5kW 16,0kW 8,3kW 0,0kW 13,1kW
TOTAL EMERGENCY SWBD 230V: 180kW Trafo
68,5 % 4,6 % 4,6 % 5,4 % 8,9 % 9,7 % 8,9 % 4,6 % 0,0 % 7,3 %
.