DC Power Supply
Connection Terminals
Trunk Connection
Terminals
98 111.25
(3.87) (4.38)
Enclosure
6.6
98.04 (0.26)
(3.86)
Black
Drain
Blue
Red
Drain
Red
PCB
Dimension A"
Trunk Cable 4 inches
Figure 4:
Input from End of Cable Jacket Should
Power Supply Protrude Approx. 1/8 in.
Loosened
Gland Nut
Locking Nut
Align Wire End with Clamping
Cavity of Terminal Block
1. To install trunk cable into PowerTap connection cut and ATTENTION: Be certain to use insulating tubing
strip gray PVC cable back approximately 4 inches (see (included in accessory kit) on bare drain wire.
Figure 3) and insert through large cable gland. Note:
Trunk cable used for input from power supply should have
white and blue leads cut off short. 5. To attach cable to terminal strips, press down on cage
2. Loosen gland nut and insert cable until approximately 1/8 clamp, insert wire and release cage clamp. Repeat
inch of cable jacket protrudes. process for remaining wires.
3. Firmly tighten gland nut to provide strain relief and sealing. 6. After all cables are terminated, the cover should be
Caution: The hex flange must be held with the cable gland installed and securely tightened to ensure washdown
wrench during tightening. rating.
4. Bare wire ends should be firmly twisted to eliminate loose All external wiring must conform to national electric code and
strands and each lead looped approximately as shown, to local codes.
allow insertion into the clamping cavity of the terminal
block. (See Figure 2 for color codes.)