ALLIANCE PRECAST INDUSTRIES SDN BHD (Company No : 436253-T)

Lot 9022, Jln. Sg. Buaya, Kampung Koskan, 48200 Rawang, Selangor Darul Ehsan.
Tel: 03-6028 4088(Hunting Line) Fax: 03-6028 4018

LONGITUDINAL SECTION OF EXTENSION PILE W

LIFTING HOOK POSITION LIFTING HOOK POSITION


min. concrete cover
BY 2 POINTS LIFT BY 2 POINTS LIFT

1/5L 3/5L 1/5L TOE


END ms stirrup
END PLATE
PLATE PVC Tube to
Hook's Tip To Hook's Tip To SECTION 1-1
MS Pipe Engineer's MS Pipe
Be Painted 1 Be Painted
Specifications
ht main bars
**for 250(8T10)

Female Joint
1 Male Joint Refers to MS Pipe with
Refers to
Connection Detail A protrusion To
Connection X Y Z Y X
Detail B Detail A
PITCH P1 PITCH P2 PITCH P2 PITCH P1

Female
PILE LENGTH, L Joint Plate
with slotted
52mm Ø i.d. MS Pipe
(60mm Ø o.d.) MS Pipe To
X is over a distance of 3 times the pile width from each head/toe end. The transition length, Y is between the pile head/toe to the pile body Detail B

MS Pipe with 1.5 x50 Skirting


5mm Protrusion Anchorage
Bar
MALE CONNECTION (DETAIL A)

COMPRESSIVE RECOMMENDED
PILE PILE NOMINAL MAIN STIRRUPS JOINT PLATE ANCHORAGE STRENGTH CONCRETE WORKING
REF. NOMINAL SIZE LENGTH REINFORCEMENT STEEL AREA CONCRETE AREA * WIRE SIZE PITCH, P1 X PITCH, P2 Y PITCH,P3 THICKNESS BARS CLASS COVER CAPACITY
(m) (nos) (size) (As mm²) (Ac mm²) (mm) (mm) (mm) (mm) (mm) (mm) (mm) nos dia length (N/mm²) (mm) (tons)

GI 250 250 X 250 12,9,6,3 8 T10 628 61872 5.5 43 750 43-125 750 125 8 4 16 520 50 40 80

MAX. STRUCTURAL WORKING CAPACITY = (fcu x Ac) / 3.65 + 0.55fy x As (CP 116)
Where, fcu = Characteristic concrete strength at 28 days (N/mm2)
Note: allow extra
fy = Main reinforcement yield strength (N/mm2) 5mm gap after top Pile Size A (HTDB) B & C(mm) D(mm)
Ac = Concrete area (mm2) 150 mm to 200 mm T12 at 400 mm length 75 mm 400 mm
As = Main reinforcement steel area (mm2) Plate Thickness 230 mm to 400 mm T16 at 600 mm length 150 mm 600 mm
Note : Fillet Weld
Fillet Weld
API RC PILES DESIGN IS REFERRED GENERALLY TO BS 8004 AND BS 8110 OR EQUIVALENT. TITLE: API PRECAST 250 RC SQUARE PILE-CONCRETE GRADE 50
MIN. CHARACTERISTIC CONCRETE CUBE STRENGTH AT 28 DAYS = 50 N/mm² Female Joint Plate PROJECT : PROPOSED CONSTRUCTION & COMPLETION OF SMALL MEDIUM ENTERRISE (SME)
(anchorage bars not 52mm Ø i.d. MS Pipe
HIGH TENSILE MAIN REINFORCEMENT YIELD STRENGTH, fy = 460 N/mm² (60mm Ø o.d.) PHASE 1B AT KERTIH BIOPOLYMER PARK, MUKIM KERTIH, KEMAMAN, TERENGGANU
DARUL IMAN FOR THE EAST COAST ECONOMIC REGION DEVELOPMENT
RC Square Pile
DRAWING NOT TO SCALE. ALL DIMENSIONS ARE IN MM UNLESS INDICATED OTHERWISE. COUNCIL (ECER)
The actual working load capacity shall be based on soil condition at site and to be determined by load test
The drawing details are subjected to approval of the consultants / authorities Date : DRAWING NO : REVISION :
FEMALE CONNECTION (DETAIL B)
* Pitch is closer if smaller wire is used. 18th Oct 2023 API/250/GI/G50/001 A