You are on page 1of 6

We reserve all rights in this document and in the information

contained therein. Reproduction, use or disclosure to third


Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Product
Based on
1CS128793_C
SGT-800 PG B
SE-612 83 FINSPONG, Sweden
Maintenance Instruction

Leakage Test Instruction

Araucaria Las Palmas

Doc. Kind
Leakage Test Instruction
A
Doc. No.

Rev. ind.

M /& DC105
Techn. Area / DCC
E1B100043856

Maintenance Instructions
Siemens Industrial Turbomachinery AB
Page
1 (6)

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00


Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE
Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
Maintenance Instruction Doc. No.
E1B100043856
Rev. ind.
A
Leakage Test Instruction Techn. Area / DCC Page
M /& DC105 2 (6)

Contents

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00

ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE


1 Introduction ................................................................................................... 3

2 Test Procedure .............................................................................................. 4


Leakage test of MBP60AA005
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


Error! Reference source not found. Araucaria Las Palmas / BD350/351/352/353
Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
Maintenance Instruction Doc. No.
E1B100043856
Rev. ind.
A
Leakage Test Instruction Techn. Area / DCC Page
M /& DC105 3 (6)

1 Introduction

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00

ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE


Leakage test of the shut off valve MBP60AA005 shall be performed at depressurized
system at scheduled inspection no more than once a year. The purpose of the leakage test
is to ensure the tightness of the shut off valve.

This instruction refers to the ignition gas system.


P&ID according to Figure 1 MBP.
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Figure 1

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


Error! Reference source not found. Araucaria Las Palmas / BD350/351/352/353
Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
Maintenance Instruction Doc. No.
E1B100043856
Rev. ind.
A
Leakage Test Instruction Techn. Area / DCC Page
M /& DC105 4 (6)

2 Test Procedure

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00


Leakage test of MBP60AA005

ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE


Test sequence:
1. Make sure that the GT is not in operation.
2. Make sure that the GT enclosure ventilation is in operation.
3. Make sure that the gas system is depressurized, for example.
 The gas trapped between MBP10AA010 and MBP60AA005 is ventilated
via MBP10AA210, and the gas trapped between MBP60AA005 and
MBP60AA015 and MBP55AA035 is ventilated via MBP60AA205.
4. Visually inspect the pressure indicator read, zero at the manometer:
 MBP60CP005 (MBP10AA010 must be closed) the pressure must be
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third

atmospheric.
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

5. Initiate GT start. Abort start when 15 s remaining of purge time, see Figure 2. Do
not use the emergency stop. Before entering the enclosure, manually block the
CO2-equipment to prevent CO2 release while working in the enclosure. (See
relevant Operating Safety document.) Read the manometer
 MBP60CP005
During reading there should be gas trapped between
 MBP10AA010, MBP10AA015 and MBP60AA005, The pressure
transmitter MBP10CP005 should indicate typical main gas pressure.
6. Reject criteria:
The pressure is 12 bar(g) or above. Replace the valve and perform the leakage test
again.
7. Accept criteria:
The pressure is below 12 bar(g)
 MBP60AA005 can be considered as leak-tight.

SE-612 83 FINSPONG, Sweden Siemens Industrial Turbomachinery AB


Error! Reference source not found. Araucaria Las Palmas / BD350/351/352/353
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

Figure 2

SE-612 83 FINSPONG, Sweden


Error! Reference source not found.
Maintenance Instruction

Leakage Test Instruction


A
Doc. No.

Rev. ind.

M /& DC105
Techn. Area / DCC
E1B100043856

Araucaria Las Palmas / BD350/351/352/353


Siemens Industrial Turbomachinery AB
Page
5 (6)

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00


Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE
We reserve all rights in this document and in the information
contained therein. Reproduction, use or disclosure to third
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB

SE-612 83 FINSPONG, Sweden


REVISION

ind. Chapt. (C)

Error! Reference source not found.


Rev. Page (P) Description
Maintenance Instruction

Leakage Test Instruction


A
Doc. No.

Rev. ind.

Date
M /& DC105
Techn. Area / DCC
E1B100043856

Dept. / Init.

Araucaria Las Palmas / BD350/351/352/353


Siemens Industrial Turbomachinery AB
Page
6 (6)

ID:E1B100043856 Name:Leakage test instruction Rev:A Protection:Restricted IP:R00,S00


Creator:Lindberg, ,Z00370JA 2017-05-24 Reviewer:Andersson,,Z002AR5R 2017-05-24 Approver:Aahlin, Ka,Z0031UWP 2017-05-24
ECC Classification: AL:N ECCN:N ECL: US-Content:No Country of origin:SE

You might also like