Professional Documents
Culture Documents
Product
Based on
1CS128793_C
SGT-800 PG B
SE-612 83 FINSPONG, Sweden
Maintenance Instruction
Doc. Kind
Leakage Test Instruction
A
Doc. No.
Rev. ind.
M /& DC105
Techn. Area / DCC
E1B100043856
Maintenance Instructions
Siemens Industrial Turbomachinery AB
Page
1 (6)
Contents
1 Introduction
Figure 1
2 Test Procedure
atmospheric.
Parties without express authority is strictly forbidden.
© Siemens Industrial Turbomachinery AB
5. Initiate GT start. Abort start when 15 s remaining of purge time, see Figure 2. Do
not use the emergency stop. Before entering the enclosure, manually block the
CO2-equipment to prevent CO2 release while working in the enclosure. (See
relevant Operating Safety document.) Read the manometer
MBP60CP005
During reading there should be gas trapped between
MBP10AA010, MBP10AA015 and MBP60AA005, The pressure
transmitter MBP10CP005 should indicate typical main gas pressure.
6. Reject criteria:
The pressure is 12 bar(g) or above. Replace the valve and perform the leakage test
again.
7. Accept criteria:
The pressure is below 12 bar(g)
MBP60AA005 can be considered as leak-tight.
Figure 2
Rev. ind.
M /& DC105
Techn. Area / DCC
E1B100043856
Rev. ind.
Date
M /& DC105
Techn. Area / DCC
E1B100043856