You are on page 1of 3

NEW-RENEWABLE ENERGY EXPERIMENTAL EQUIPMENT

email: sales@issyam.com / pt.issyam@gmail.com

NO. EQUIPMENT NAME MODEL inverter, auto transfer switch (ATS), and load device, thus it should be
Solar Power Generation Experiment equipped with controlling system devices.
KTE-7000SG (4) (Option) AUTO control adjusting part (SQ or PLC control)
Equipment
2. This equipment is composed of console type, so wherever it can be
I. IMAGE available in commercial power supply.
3. Device should be composed of banana plug contactor for saving circuit
configuration time.
4. The power conversion device and the control panel should be connected as
vertical type.
5. When over production of electric power, it should transmit power to
commercial electricity, when low production of electric power, it should get
transmit power from commercial electricity.
6. There should be the working textbook that contains step by step
experiment process, and the guide book that the teacher can refer to teach
with.

III. SPECIFICATION
Page 1 of 3

1. Solar Generator Module


(1) Solar Photo Voltaic module
1) Output: 20W module 4EA

2. Power Conversion Module


(1) Joint Box: 1EA
1) Input;
 Appearance and specifications may be changed by the upgrade. ① DC voltage: Max 250VDC / 1ch
② DC current: Max 11A / 1ch
II. FEATURE 2) Operation
① Operation temp range : -10°C ~ 60°C
1. System composition ② Operation humidity range : maximum 90% RH
(1) This system is composed of a Solar Generator module and a Power
Conversion module. (2) Grid-connection Inverter: 1EA
(2) The Solar Generator module is configured as fix axis type that can 1) Input;
produce electricity by using solar light. ① MPPT Voltage Range: DC 10.8V-30V
(3) The Power Conversion module should be configured as joint-box, charging ② Control Type: Max Power Point Tracking Control (MPPT control)
controller, battery, stand-alone type inverter, grid-connection type 2) Output

KTENG CORPORATION | 2020

B1
NEW-RENEWABLE ENERGY EXPERIMENTAL EQUIPMENT
email: sales@issyam.com / pt.issyam@gmail.com

① Rated Output Capacity: 300W 7) AC Lamp: 1EA


② Rated Voltage: Grid Voltage AC 190V-250V 8) Connectable port : 1EA
③ Phase: Single AC (9) Size
④ Efficiency: More than 92% 1) Table: 1220(W) * 1580(H) * 730(D)(mm)
(3) Stand-alone inverter: 2EA 2) Control panel: 960(W) * 400(H) * 220(D)(mm)
1) Input Voltage: DC 24V
2) Output Voltage: AC 220V
3) Capacity: 500W IV. TEXTBOOK & ANIMATION CONTENTS
4) Function
① Protection overload 1. PLC electric circuit control theory & application
② Protection overheat (1) Basic circuit installation training with switches
③ Prevention surge (2) C-contact circuit training with Relay switches.
④ Auto FAN (3) AND circuit configuration and training
⑤ Warning buzzer (4) OR circuit configuration and training
⑥ Reduction low noise (5) NOT circuit configuration and training
⑦ Prevention low voltage (6) NAND circuit configuration and training
(4) Battery: 1EA (7) NOR circuit configuration and training
1) Voltage: DC 12V (8) Self hold circuit configuration and training
2) Capacity: 12V 55AH
Page 2 of 3

(5) Charging controller: 1EA 2. Solar powered generation system application training & experiment
1) Control function: Control charging or discharging curriculum
(6) Auto reversing switch: 1EA (1) Off-grid inverter system installation training
1) Main power: 190~240V (2) Load test of solar power module
2) Main frequency: 60Hz (3) Series and parallel control circuit composition and load power input
3) Auxiliary power: 0~240V circuit
4) Auxiliary frequency: Not monitored (4) Automatic transfer circuit configuration at electric discharge or
5) Auxiliary switching power: 180V power failure
6) Power reversing time: 20s (5) Grid-connected inverter circuit configuration
(7) Load device (6) Module efficiency test by variation of incidence angle
1) Lamp: more than LED 10W (7) Battery power input circuit training
(8) Control panel (8) Experiment of power output by Series & parallel circuit
1) Material: AL configuration
2) NFB 30A, Single 1A: 1EA (9) Real-time monitoring experiment
3) SMPS (24V 3.1A) (10) System connect inverter load operation experiment
4) Watt meter : 3EA (11) System connect inverter system PLC control training
5) Voltage meter: DC voltage 2EA, AC voltage 3EA (12) Termination voltage measurement experiment by discharge of
6) Current meter: DC Am meter 2EA, AC Am meter 3EA battery

KTENG CORPORATION | 2020

B1
NEW-RENEWABLE ENERGY EXPERIMENTAL EQUIPMENT
email: sales@issyam.com / pt.issyam@gmail.com

(13) Charger controller overcharge prevention experiment inverter, off-gird inverter and power supply

2. Data acquisition software


3. Animation & Flash program (6) Real-time displaying of current & voltage graph and system
(1) Simulation program suitable for sequence circuit training diagrams
(2) Contains 10 different circuit animation contents for on-job training (7) Adjustment feature of solar radiation value, panel temperature,
(3) Voice instructions connected with each animations of circuit system area of solar penal and number of solar cell or modules
(4) Can display circuit circulation process with visualized animations (8) Can measure and calculate the input / output voltage of both off
(5) Can explain each phase of sequence circuit operating system grid & system interconnection inverter
(6) Includes circuit installation instruction video for users. (9) Can select data acquisition interval time and display data by one
decimal points
4. Video contents (10) Offset adjustment to voltage available by displaying varied amount
(1) Includes circuit installation progress video which helps users by users
operating the equipment (11) Prevents data loss from power shutdown by saving data to xml
(2) Provided with operation guide voice comments format
(3) Instructions of solar powered electric conversion equipment (12) Real-time monitoring of battery usage available
installation & operation (13) Shows diagram of experiment process by indicating voltage &
(4) Solar powered electric conversion controller instruction current of each components and helps understanding of overall
(5) Solar powered electric converter components instruction system
Page 3 of 3

(6) Data acquisition hardware instruction (14) Includes image capture & save of displayed diagram and graphs
(7) Introduction of solar powered electric conversion experiment (15) Can display selected voltage & current on the graph
equipment components (16) Compatible with Windows 2000, XP, Vista, 2008 and both 32bit &
64bit OS

VI. ACCESSORIES, GUARANTEE AND DELIVERY


V. PROGRAM HARDWARE & SOFTWARE 1. Power Cable: 1 EA
2. Banana jack: Red 20EA, Black 20EA
1. Data acquisition hardware 3. Solar & wind power generation system facility control training contents CD
(1) Can measure change of physical phenomenon depends on the type 4. User guidebook: 1EA
of sensors and variation of voltage & current 5. Guarantee: For 1 year
(2) Converts and controls analog signals of temperature, pressure,
voltage into digital data
(3) Can be connected with PC provides manual adjusting features to
control each components of solar power generation equipment
(4) Uses RS-232 signaling method to interlock with common software
(5) Displays DC/AC voltage and current of each components including
solar panel, charger controller, battery, system interconnection

KTENG CORPORATION | 2020