Discharge through orifice plate is calculated by formula = Below Details are available
q = ca((2gh)^0.5)
Q cum/sec.
c co-oefficient = 0.6
g 9.81 m/sec2
h head in m
a Area in metres from which dia. Of orifice is calculated.
AVAILABLE PR. AVAILABLE PR. AVAILABLE PR FLOW
ORIFICE ORIFICE FLANGE
KG(F)/SQ.CM KG(F)/SQ.CM DIFFERENCE, THROUGH
SR.NO EQUPT NO. DIAMETER, DIAMETER DIAMETER,
UPSTREAM OF DOWNSTREAM KG(F)/SQ.CM ORIFICE,
MM PROVIDED MM
ORIFICE = OF ORIFICE = = CUM/SEC