You are on page 1of 1

TH Chamber故障及处理方案

TH Chamber fault and repair scheme


序号 型号 故障 原因分析 处理方案 附图
NO. Model Fault Cause analysis Repair scheme Figures

1、故障排查 Troubleshooting
2、氮气检漏 Nitrogen leak detection
R23系统蒸发器漏气 3、蒸发器补漏 Evaporator trapping
KTM THE-515 无法降温
1 R23 system evaporator air leakage 4、焊接、保压、抽真空
SN:T2616 Unable to cool down
Welding, pressure keeping and vacuuming
5、灌满冷媒R23 Fill refrigerant R23
6、调试运行 Debugging running

1、电路检查 Circuit inspection


2、制冷系统检查 Refrigeration system inspection
3、故障排除 Troubleshooting
4、更换新的干燥过滤器
1、电磁阀、干燥过滤器、油分离
Replace the dry filter with a new one
器冰封
5、更换新的膨胀阀
Solenoid valve, dry filter, oil
Replace the expansion valve with a new one
separator ice seal
KTM THE-515 无法降温 6、焊接、保压、抽真空
2 2、压缩机管道里有水分,未被干
SN:T2530 Unable to cool down Welding, pressure keeping and vacuuming
燥以及膨胀阀损坏
7、氮气冲洗压缩机 Nitrogen flushing compressor
Moisture in the compressor pipeline,
8、添加冷冻油 Add refrigeration oil
which is not damaged by drying and
9、添加制冷剂R23,满罐 Add refrigerant R23, full
expansion valve
tank
10.调试运行 Debugging running