PRE-INSTALLATION INSPECTION
THANK YOU FOR THE PURCHASE OF YOUR ROHN PRODUCT. WE ARE EXCITED THAT YOU
CHOOSE ROHN TO SUPPLY YOU WITH A QUALITY PRODUCT. IN ORDER TO COMMUNICATE
EFFECTIVELY, ELIMINATE ERRORS AND PROVIDE A SMOOTH INSTALLATION EXPERIENCE,
IT IS IMPORTANT FOR THE INSTALLER TO PERFORM A PRE-INSTALLATION INSPECTION OF
ALL COMPONENTS/PARTS ASSOCIATED WITH YOUR ORDER. PRIOR TO THE INSTALLATION,
THE FOLLOWING INSPECTIONS ARE REQUIRED:
ROHN WILL NOT BE RESPONSIBLE FOR CHARGES ASSOCIATED WITH INSTALLING THE
PRODUCTS LLC
WRONG SIZE ANCHOR RODS, THE WRONG NUMBER OF ANCHOR RODS OR THE PO BOX 5999
PEORIA, IL 61601-5999
INCORRECT ANCHOR ROD ORIENTATION. TOLL FREE 800-727-ROHN
· ROHN WILL NOT BE RESPONSIBLE FOR EXCESS CHARGES INCLUDING CRANE CHARGES, THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
DRILLING RIG CHARGES, EQUIPMENT CHARGES, CREW CHARGES AND MOBILIZATION
CHARGES. PRE-INSTALLATION INSPECTION
FORM NUMBER: FM060
· IF YOU HAVE ANY QUESTIONS, PLEASE CONTACT THE APPROPRIATE ROHN SALES
REP/MANAGER AT (309) 566-3000. DWN: CHK'D: DATE:
JHY JDM 09/03/2019
ENG'R: SHEET #:
HA 1 OF 1
PRJ. ENG'R: PRJ. MANG'R:
FM060 0
FILE NO.
Standard-45G
REVISIONS
40' TOWER 50' TOWER 60' TOWER 70' TOWER 80' TOWER 90' TOWER REV. DESCRIPTION DWN CHK APP
15.2 OR 11.1 14.3 OR 10.6 13.5 OR 10.2 12.9 OR 9.8 12.5 OR 9.6 12.0 OR 9.3
35' 45' 55' 65' 75' 85' 1 JWS KTL HA
13.0 12.0 11.6 11.0 10.6 10.0
11
60
73
47
86
99
(665#) (665#) (665#) (665#) (665#) (665#)
1'
'
'
'
'
'
3/16"EHS 3/16"EHS 3/16"EHS 3/16"EHS
25' (399#) 29' (399#) 35' (399#) 39' (399#)
54 63 73 82
' ' ' '
P/N: 45G130R040 P/N: 45G130R050 P/N: 45G130R060 P/N: 45G130R070 P/N: 45G130R080 P/N: 45G130R090
100' TOWER 110' TOWER 120' TOWER 130' TOWER 140' TOWER 150' TOWER
11.6 OR 9.1 11.4 OR 8.9 11.1 OR 8.8 10.8 OR 8.6 10.6 OR 8.5 10.4 OR 8.4
95' 105' *115' *125' *135' *145'
9.6 9.0 8.6 8.2 7.8 7.4
13
15
16
17
18
(665#) (665#) (1,120#) (1,120#) 98' (1,120#) 106' (1,120#)
7
8
4
'
'
'
'
'
'
61' 67' 75' 78' 1/4"EHS 1/4"EHS 1/4"EHS FABRICATION TOLERANCES (UNO)
14
16
13
9'
0'
3/16"EHS 3/16"EHS 3/16"EHS (665#) (665#) (665#)
10
11
12
0'
(399#) (399#) (399#) 65' 72'
1'
1'
2'
3/16"EHS 12 3/16"EHS 14 3/16"EHS
(399#) 9 ' (399#) 0' (399#)
31' 34' 35' 35'
86' 94' 102 110
' ' 32' 116 35' 125
' '
NOTE:
P/N: 45G130R100 P/N: 45G130R110 P/N: 45G130R120 P/N: 45G130R130 P/N: 45G130R140 P/N: 45G130R150 HOLES MAY BE PUNCHED, DRILLED OR THERMALLY CUT, UNLESS OTHERWISE
INDICATED ON FABRICATION DRAWING. SURFACE ROUGHNESS PROFILE
110 MPH FASTEST MILE WIND SPEED 2. ALLOWABLE PROJ. AREA (SQ. FT.) FOR EXPOSURE B - (REV G).
NO ICE (REV F) ALLOWABLE PROJ. AREA (SQ. FT.) FOR EXPOSURE C - (REV G).
ALLOWABLE PROJ. AREA (SQ.FT.) - (REV F).
3. EFFECTIVE PROJ. AREAS MUST NOT EXCEED THE AREAS SHOWN.
BASE PIER ANCHOR DATA
4. ANTENNAS AND MOUNTS ARE ASSUMED SYMMETRICALLY PLACED AT THE TOWER TOP.
(DWG: B090549) (DWG: B090550)
TOWER 5. DESIGNS ASSUME TWO 1/2" DIA. LINES ON EACH TOWER FACE.
HT. 6. FOR GUY HARDWARE INSTALLATION DETAILS, SEE DWG. A871382.
NOTE: FOR SPACE BLOCK ROD
REQUIREMENTS NO. ROD NO. 7. ANCHOR RADIUS IS FROM TOWER BASE TO INTERSECTION OF ROD WITH GROUND.
SEE DWG. NO. ANGLE 8. TOWER DESIGNS AND GUY CHORD LENGTHS SHOWN ARE BASED ON LEVEL GROUND. ADD 6 PERCENT
NO. C640531 TO CHORD LENGTHS (FOR SAG AND CONNECTIONS) FOR FINAL CUT LENGTHS. ( ) INDICATES
40' CB1G AB2 GAC3455TOP 48 INITIAL TENSION FOR GUY WIRES IN POUNDS AT 60 DEGREES FAHRENHEIT.
9. DO NOT INSTALL OR DISMANTLE TOWERS WITHIN FALLING DISTANCE OF ELECTRICAL AND/OR PRODUCTS LLC
TOWER PLAN (TYP) 50' CB1G AB2 GAC3455TOP 48
TELEPHONE LINES. PO BOX 5999
ROD ANGLE 60' CB1G AB2 GAC3455TOP 40 10. TOWER ERECTION AND DISMANTLING MUST BE DONE BY QUALIFIED AND EXPERIENCED PEORIA, IL 61601-5999
IN DEGREES 70' CB1G AB2 GAC3455TOP 40 PERSONNEL. TOLL FREE 800-727-ROHN
11. TEMPORARY STEEL GUYS, WHEN REQUIRED DURING ERECTION OR DISMANTLING,
GROUND LINE 80' CB1G AB2 GAC3455TOP 40 THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
MUST BE SUPPLIED AND INSTALLED BY THE ERECTOR. REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
90' CB1G AB2 GAC3455TOP 40 12. INSTALL WARNING PLATE (P/N: ACWS) IN A HIGHLY VISIBLE LOCATION.
FOR GUY CONN. 13. ALL ANTENNA INSTALLATIONS MUST BE GROUNDED IN ACCORDANCE WITH LOCAL
100' CB1G AB2 GAC3455TOP 38 AND NATIONAL CODES.
DETAILS SEE DWG.#
B820511 110' CB1G AB2 GAC3455TOP 38 14. EXTRA CABLE CLAMPS HAVE BEEN PROVIDED FOR TURNBUCKLE SAFETY REQUIREMENTS. FOR
DETAILS SEE DWG. B680324 LATEST REVISION.
120' CB1G AB2 GAC3455TOP 38 15. PURCHASER SHALL VERIFY THE INSTALLATION IS IN CONFORMANCE WITH LOCAL, STATE AND
130' CB2G AB3 GAC5655TOP 38 FEDERAL REQUIREMENTS FOR OBSTRUCTION MARKING AND LIGHTING.
DWN: CHK'D: DATE:
16. TOLERANCE ON TOWER STEEL IS EQUAL TO PLUS 1% AND MINUS 1/2%.
140' CB2G AB3 GAC5655TOP 37 JWS KTL Feb/10/2010
17. DESIGNS ASSUME THAT, AS A MINIMUM, MAINTENANCE AND INSPECTION WILL BE PERFORMED
OVER THE LIFE OF THE STRUCTURE IN ACCORDANCE WITH ANSI/TIA/EIA-222-G. ENG'R:
150' CB2G AB3 GAC5655TOP 37
18. ANCHOR RODS CORROSION PROTECTION METHODS TO BE PROVIDED BY OTHERS. HA
\Erection\
DWG-0074 1
FILE NO.
REVISIONS
REV. DESCRIPTION DWN CHK APP
FOUNDATION AND ANCHOR TOLERANCES REMOVED WARNING TEXT
10 MJH JDM HA
DATE: 01/12/2017
ALL FOUNDATIONS
1. CONCRETE DIMENSIONS: PLUS OR MINUS 1" (25mm)
2. DEPTH OF FOUNDATION: PLUS 3" (76mm) OR MINUS 0"
3. DRILLED FOUNDATIONS OUT OF PLUMB: 1.0°
4. REINFORCING STEEL PLACEMENT: PER A.C.I. 301
5. PROJECTION OF EMBEDMENTS: PLUS OR MINUS 1/8" (3mm)
6. VERTICAL EMBEDMENTS OUT OF PLUMB: 0.5°
ANCHOR BOLTS
7. MAXIMUM DISTANCE FROM CENTERLINE OF ANCHOR BOLTS TO CENTERLINE OF
FOUNDATION: 1/24 OF PIER DIAMETER UP TO A MAXIMUM OF 2" (51mm)
8. ANCHOR BOLT SPACING: 1/16" (2mm)
9. ANCHOR BOLT CIRCLE ORIENTATION: 0.25°
10. ANCHOR BOLT CIRCLE DIAMETER: PLUS OR MINUS 1/16" (2mm)
SELF-SUPPORTING TOWERS
11. FACE SPREAD DIMENSION CENTER TO CENTER OF ANCHOR BOLT CIRCLES: PLUS OR
MINUS 1/16" (2mm) OR 1/16" (2mm) PER 20 FT. (6m) OF FACE SPREAD
12. MAXIMUM DIFFERENCE BETWEEN ANY TWO FOUNDATION ELEVATIONS: 1/2" (13mm)
GUYED TOWERS
13. GUY RADIUS: PLUS OR MINUS 5% OF DISTANCE SPECIFIED
14. ANCHOR ELEVATION: PLUS OR MINUS 5% OF GUY RADIUS
15. ANCHOR ALIGNMENT (PERPENDICULAR TO GUY RADIUS): 1.0° ®
16. ANCHOR ROD SLOPE: PLUS OR MINUS 1.0°
PRODUCTS, LLC
17. ANCHOR ROD ALIGNMENT WITH GUY RADIUS: PLUS OR MINUS 1.0°
PO BOX 5999
18. ANCHOR HEAD OUT OF PLUMB: 1.0° PEORIA, IL 61601-5999
19. GUY INITIAL TENSION: PLUS OR MINUS 10% OF TENSION SPECIFIED TOLL FREE 800-727-ROHN
THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
NOTE: TOLERANCES IN NOTES 13 AND 14 CAN NOT OCCUR SIMULTANEOUSLY.
FOUNDATION & ANCHOR TOLERANCE
A810214 10
FILE NO.
STDPUBLIC
REVISIONS
REV. DESCRIPTION DWN CHK APP
1. SEE TOWER ASSEMBLY DRAWING FOR FOUNDATION LAYOUT THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
F ROUGHEN CONSTRUCTION JOINT TO AND PART NUMBERS FOR BEARING PLATE & PIER PIN.
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
A FULL AMPLITUDE OF 1/4" 2. SEE DRAWING NUMBER B090548 FOR STANDARD FOUNDATION NOTES.
FOUNDATION PAD 3. USE MIN. 2'-6" SQ. OR 3'-0" DIA. ROUND PIER WHEN BPC45G
OR BPC55G IS USED.
ELEVATION VIEW HORIZONTAL REINFORCING 4. VERTICAL REINFORCING STEEL SHALL BE REPLACED WITH STRAIGHT
STEEL EQUALLY SPACED EACH WAY BARS WHEN NO PAD IS REQUIRED. DWN: CHK'D: DATE:
FAD HA Nov/24/2009
(SEE CHART FOR NO. & SIZE) 5. HORIZ. BARS IN CHART REFER ONLY TO THE BARS IN THE ENG'R:
FOUNDATION PAD. HA
\Erection\
B090549 0
FILE NO.
STDPUBLIC
REVISIONS
ANCHOR ROD ANCHOR ROD REV. DESCRIPTION DWN CHK APP
REDRAWN
4 JHY HA HA
DATE: 12/9/2013
GROUND LINE GROUND LINE
ADDITIONAL BARS
@ CENTER-LINE EACH SIDE CL CL
B
WHEN REQUIRED
6 SWG
1. STANDARD FOUNDATION DESIGNS ARE IN ACCORDANCE WITH ANSI/TIA-222-G/H, "STRUCTURAL STANDARDS 13. SPACERS SHALL BE ATTACHED INTERMITTENTLY THROUGHOUT THE ENTIRE LENGTH OF VERTICAL DATE: 1/28/2020
FOR STEEL ANTENNA TOWERS AND ANTENNA SUPPORTING STRUCTURES" FOR THE FOLLOWING REINFORCING CAGES TO INSURE CONCENTRIC PLACEMENT OF CAGES IN EXCAVATIONS.
PRESUMPTIVE CLAY SOIL PARAMETERS: 14. FOUNDATION DESIGNS ASSUME STRUCTURAL BACKFILL TO BE COMPACTED IN 8 INCH (200 mm) MAXIMUM
LAYERS TO 95% OF MAXIMUM DRY DENSITY AT OPTIMUM MOISTURE CONTENT IN ACCORDANCE WITH ASTM
Ultimate Bearing
(psf) Ultimate D698. ADDITIONALLY, STRUCTURAL BACKFILL MUST HAVE A MINIMUM COMPACTED UNIT WEIGHT OF 110
N Y C k
Φ [kPa] Skin Friction POUNDS PER CUBIC FOOT (17 kN/m3).
(blows/ft) (lb/ft3) (psf) (pci) ε50
(deg) (psf)
[blows/m] [kN/m3] [kPa] Shallow Deep [kN/m3] 15. FOUNDATION DESIGNS ASSUME AN INSTALLATION ON A PROPERLY DRAINED LEVEL SITE.
[kPa]
Fnds. Fnds.
16. FOUNDATION INSTALLATION SHALL BE SUPERVISED BY PERSONNEL KNOWLEDGEABLE AND EXPERIENCED
110 1000 5000 9000 500 150
8 [26] 0 0.01 WITH THE PROPOSED FOUNDATION TYPE. CONSTRUCTION SHALL BE IN ACCORDANCE WITH GENERALLY
[17] [48] [240] [431] [24] [41,000]
ACCEPTED INSTALLATION PRACTICES.
GROUND WATER TABLE IS AT OR BELOW FOUNDATION DEPTH
MAXIMUM FROST PENETRATION DEPTH LESS THAN FOUNDATION DEPTH 17. ALL CONSTRUCTION AND SAFETY EQUIPMENT AND TEMPORARY SUPPORTS REQUIRED FOR CONSTRUCTION
SHALL BE DETERMINED, FURNISHED AND INSTALLED BY THE CONTRACTOR BASED ON THE MEANS AND
2. THE PURCHASER SHALL VERIFY THAT ACTUAL SITE SOIL PARAMETERS MEET OR EXCEED ANSI/TIA-222-G/H METHODS CHOSEN BY THE CONTRACTOR. ALL CONSTRUCTION ACTIVITIES SHALL BE PREFORMED BY
PRESUMPTIVE CLAY SOIL DESIGN PARAMETERS AND THAT THE DEPTH OF STANDARD FOUNDATIONS ARE COMPETENT, QUALIFIED AND TRAINED PERSONNEL.
ADEQUATE BASED ON THE FROST PENETRATION AND/OR ZONE OF SEASONAL MOISTURE VARIATION AT THE 18. FOR FOUNDATION AND ANCHOR TOLERANCES SEE ANCHOR ROD LAYOUT DRAWING.
SITE. FOUNDATION DESIGN MODIFICATIONS MAY BE REQUIRED IN THE EVENT PRESUMPTIVE CLAY SOIL 19. LOOSE MATERIAL SHALL BE REMOVED FROM BOTTOM OF EXCAVATION PRIOR TO CONCRETE PLACEMENT.
PARAMETERS ARE NOT APPLICABLE FOR THE ACTUAL SUBSURFACE CONDITIONS ENCOUNTERED. SIDES OF EXCAVATION SHALL BE ROUGH AND FREE OF LOOSE CUTTINGS.
3. A SITE-SPECIFIC INVESTIGATION IS REQUIRED FOR CLASS III STRUCTURES IN ACCORDANCE WITH 20. CONCRETE SHALL BE PLACED IN A MANNER THAT WILL PREVENT SEGREGATION OF CONCRETE MATERIALS,
ANSI/TIA-222-G/H. INFILTRATION OF WATER OR SOIL AND OTHER OCCURRENCES WHICH MAY DECREASE THE STRENGTH OR
4. FOUNDATION DESIGNS ASSUME FIELD INSPECTIONS WILL BE PERFORMED BY THE PURCHASER'S DURABILITY OF THE FOUNDATION.
REPRESENTATIVE TO VERIFY THAT CONSTRUCTION MATERIALS, INSTALLATION METHODS AND ASSUMED 21. FREE FALL CONCRETE MAY BE USED PROVIDED FALL IS VERTICAL DOWN WITHOUT HITTING SIDES OF
DESIGN PARAMETERS ARE ACCEPTABLE BASED ON THE CONDITIONS EXISTING AT THE SITE. EXCAVATION, FORMWORK, REINFORCING BARS, ANCHORAGES, FORM TIES, CAGE BRACING OR OTHER
5. WORK SHALL BE IN ACCORDANCE WITH THE PROJECT CONSTRUCTION DOCUMENTS, LOCAL CODES, SAFETY OBSTRUCTIONS. UNDER NO CIRCUMSTANCES SHALL CONCRETE FALL THROUGH WATER.
REGULATIONS AND UNLESS OTHERWISE NOTED, THE LATEST REVISION OF ACI 318, "BUILDING CODE 22. CONCRETE SHALL BE PLACED AGAINST UNDISTURBED SOIL EXCEPT FOR PIERS SUPPORTED ON SPREAD
REQUIREMENTS FOR REINFORCED CONCRETE". PROCEDURES FOR THE PROTECTION OF EXCAVATIONS, FOUNDATIONS. FORMS FOR PIERS SHALL BE REMOVED PRIOR TO PLACING STRUCTURAL BACKFILL.
EXISTING CONSTRUCTION AND UTILITIES SHALL BE ESTABLISHED PRIOR TO FOUNDATION INSTALLATION. 23. CONSTRUCTION JOINTS, IF REQUIRED IN DRILLED PIER OR CAISSON FOUNDATIONS, SHALL BE AT LEAST 12
6. CONCRETE MATERIALS SHALL CONFORM TO THE APPROPRIATE STATE REQUIREMENTS FOR EXPOSED INCHES (305 mm) BELOW BOTTOM OF EMBEDMENTS AND MUST BE INTENTIONALLY ROUGHENED TO A FULL
STRUCTURAL CONCRETE. AMPLITUDE OF 1/4 INCH (6 mm). FOUNDATION DESIGN ASSUMES NO OTHER CONSTRUCTION JOINTS.
7. PROPORTIONS OF CONCRETE MATERIALS SHALL BE SUITABLE FOR THE INSTALLATION METHOD UTILIZED 24. CONSTRUCTION JOINTS, IF REQUIRED AT THE BASE OF PIERS SUPPORTED ON SPREAD FOUNDATIONS, SHALL
AND SHALL RESULT IN DURABLE CONCRETE FOR RESISTANCE TO LOCAL ANTICIPATED AGGRESSIVE ACTIONS. BE INTENTIONALLY ROUGHENED TO A FULL AMPLITUDE OF 1/4 INCH (6 mm). FOUNDATION DESIGN ASSUMES
THE DURABILITY REQUIREMENT OF ACI 318 SHALL BE SATISFIED BASED ON THE CONDITIONS EXPECTED AT NO OTHER CONSTRUCTION JOINTS.
R
THE SITE. AS A MINIMUM, CONCRETE SHALL DEVELOP A MINIMUM COMPRESSIVE STRENGTH OF 4500 PSI 25. CASING, IF USED, SHALL NOT BE LEFT IN PLACE. EQUIPMENT, PROCEDURES, AND PROPORTIONS OF
(31.0 MPa) IN 28 DAYS. CONCRETE MATERIALS SHALL INSURE CONCRETE WILL NOT BE ADVERSELY DISTURBED UPON CASING
PRODUCTS LLC
8. MAXIMUM SIZE OF AGGREGATE SHALL NOT EXCEED SIZE SUITABLE FOR INSTALLATION METHOD UTILIZED OR REMOVAL. DRILLING FLUID, IF USED, SHALL BE FULLY DISPLACED BY CONCRETE AND SHALL NOT BE PO BOX 5999
3/4 CLEAR DISTANCE BEHIND OR BETWEEN REINFORCING. WORKABILITY AND METHODS OF CONSOLIDATION DETRIMENTAL TO CONCRETE OR SURROUNDING SOIL. CONTAMINATED CONCRETE SHALL BE REMOVED FROM PEORIA, IL 61601-5999
TOLL FREE 800-727-ROHN
SUCH AS VIBRATING SHALL BE UTILIZED TO PREVENT HONEYCOMBS OR VOIDS. TOP OF FOUNDATION AND REPLACED WITH FRESH CONCRETE.
THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
9. REINFORCEMENT SHALL BE DEFORMED AND CONFORM TO THE REQUIREMENTS OF ASTM A615 GRADE 60 26. TOP OF FOUNDATION SHALL BE SLOPED TO DRAIN WITH A FLOATED FINISHED. EXPOSED EDGES OF REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
UNLESS OTHERWISE NOTED. SPLICES IN REINFORCEMENT SHALL NOT BE ALLOWED UNLESS OTHERWISE CONCRETE SHALL BE CHAMFERED 3/4" X 3/4" (19 mm X 19 mm) MINIMUM.
INDICATED. 27. FOR ANCHOR BLOCK TYPE FOUNDATIONS, FOR GUYED MASTS, ADDITIONAL CORROSION PROTECTION MAY BE ANSI/TIA-222-G/H
10. REINFORCING CAGES SHALL BE BRACED TO RETAIN PROPER DIMENSIONS DURING HANDLING, THROUGHOUT REQUIRED FOR STEEL GUY ANCHORS IN DIRECT CONTACT WITH SOIL. DESIGN ASSUMES PERIODIC STANDARD FOUNDATION DESIGN NOTES
PLACEMENT OF CONCRETE AND DURING EXTRACTION OF TEMPORARY CASING. INSPECTIONS WILL BE PERFORMED OVER THE LIFE OF THE STRUCTURE TO DETERMINE IF ADDITIONAL
DWN: CHK'D: DATE:
11. WELDING IS PROHIBITED ON REINFORCING STEEL AND EMBEDMENTS. ANCHOR CORROSION PROTECTION MEASURES SHALL BE IMPLEMENTED BASED ON OBSERVED SITE-SPECIFIC FAD HA 11/20/2009
12. MINIMUM CONCRETE COVER FOR REINFORCEMENT SHALL BE 3 INCHES (76 mm) UNLESS OTHERWISE NOTED. CONDITIONS. ENG'R: SHEET #:
HA 1 OF 1
APPROVED SPACERS SHALL BE USED TO INSURE A 3 INCH (76 mm) MINIMUM COVER ON REINFORCEMENT.
PRJ. ENG'R: PRJ. MANG'R:
CONCRETE COVER FROM TOP OF FOUNDATION TO ENDS OF VERTICAL REINFORCEMENT SHALL NOT EXCEED 3
INCHES (76 mm) NOR BE LESS THAN 2 INCHES (51 mm). DRAWING NO: REV:
B090548 6
FILE NO.
3 JWS H.A HA
P/N AT
TOP
DWG REFERENCE
NOTE:
INSTALL ANCHORS IN BLOCKS WITH EMBEDMENT
ANGLES ORIENTED AS SHOWN AND WITH P/N AT
TYPICAL DETAIL
TOP AS SHOWN.
11:34:30 AM
OFFSET OFFSET
Oct/15/2010
OFFSET
PRODUCTS
ANCHOR TO BE INSERTED
INTO CONCRETE BLOCK TO
LEVEL WITH BOTTOM LAYER
OF REINFORCING BARS
DWN: CHK'D: DATE:
B_N WDU Mar/22/1995
ENG'R:
TWS
\Erection\
DWG REFERENCE
TURNBUCKLE (TYP)
EQUALIZER (TYP)
9:14:06 AM
FIVE WIRE
Feb/06/2008
ONE WIRE
ATTACHMENT PRODUCTS
B820511 2
FILE NO.
Standard-80
REVISIONS
EYE & JAW REV. DESCRIPTION DWN CHK APP
(TYP)
8 JDM M.F HA
SINGLE EQUALIZER
PLATE
DUAL ROD
TWIN EQUALIZER
Apr/23/2008
B680324 8
FILE NO.
CONCRETE ANCHOR BLOCK Standard-80
ANCHOR ROD POINT AT WHICH ANCHOR REVISIONS
REV. DESCRIPTION DWN CHK APP
ROD ENTERS THE EARTH
(ASSUMING LEVEL GRADE) 4 JDA JDM HA
15'
'B'
15'
15'
'A'
'C' SQUARE
WITH STRONGER MASTS AND LARGER GUYS MAY BE
PROVIDED BY REDUCING THE GUY RADIUS FROM
80% TO 40% OF THE TOWER HEIGHT.
LAYOUT B
DWN: CHK'D: DATE:
THIS IS THE MINUMUM AREA OF LAND MSR OH Apr/15/1975
REQUIRED TO PERMIT ORIENTING THE TOWER ENG'R:
IN ANY POSITION FOR ANTENA PATH CW
\Erection\
C640531 4
FILE NO.
24.00 REVISIONS
REV. DESCRIPTION DWN CHK APP
R9.67 120°
(REF.)
20.00
14.51
TYP. PIER PIN
BPC45G
C.L. OF FOUNDATION
& TOWER
16.75
(REF.) FOUNDATION
C.L. OF FOUNDATION
& TOWER
NOTE:
6.00
NOTES:
1. DUE TO VARIABLES INVOLVED IN ROOF AND OTHER INSTALLATIONS, IT SHALL BE THE
CUSTOMER'S OR INSTALLERS RESPONSIBILITY TO PROVIDE STRUCTURALLY ADEQUATE
SUPPORTS FOR PIER & ANCHOR CONNECTIONS. IT MAY ALSO BE NECESSARY FOR THE
CUSTOMER OR INSTALLER TO SECURE THE SERVICE OF A LOCAL ENGINEER TO
DETERMINE THAT INSTALLATION COMPLIES WITH LOCAL BUILDING CODES. 3
2. FOR USE WITH GUYED AND BRACKETED TOWERS ONLY. 4"
∅ PIER PIN
BPC45G
R
4" PIER PIN
PROJECTION (REF) FOUNDATION
PRODUCTS LLC
PO BOX 5999
PEORIA, IL 61601-5999
TOLL FREE 800-727-ROHN
THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
DWG-2298 0
FILE NO.
A A BILL OF MATERIAL - 45G
REVISIONS
ITEM PART NO. QTY DESCRIPTION REV. DESCRIPTION DWN CHK APP
LEG TS 1.25 OD X 14 GA
GENERAL NOTES:
1. PART NUMBER IS STAMPED AT THE BOTTOM OF EACH SECTION AND MUST BE LOCATED AT
THE BOTTOM OF THE SECTION FOR PROPER ASSEMBLY.
2. JOINT BOLTS ARE PROVIDED AT THE BOTTOM OF THE SECTION.
3. DRAWING IS N.T.S. AND IS FOR ASSEMBLY PURPOSES ONLY.
2
10'
16.22
(TYP)
.44 ∅ BRACING
PRODUCTS
PO BOX 5999
TOWER AXIS
PEORIA, IL 61601-5999
9 11/16"
TOLL FREE 800-727-ROHN
1'-2 1/2" THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
1
TYP 120°
SECTION ASSEMBLY FOR 45G
(TYP)
45G 0
FILE NO.
NOTE:
1. ALL SECTION ASSEMBLIES ARE PROVIDED WITH A SECTION, BOLT KIT, &
REVISION
WARNING LABEL ATTACHED.
REV. DESCRIPTION DWN CHK APP
REVISED TO LATEST FORMAT
13 JEC JHY OH
DATE: 12/16/2016
2.38" OD
2.07" ID
2.00" OD 1.66" OD 2.25" OD
1.87" ID 1.38" ID 2.08" ID
1'-6"
1'-0" 1'-0" 1'-0"
2.75" OD
2.58" ID
9'-6"
9'-0" 9'-0" 9'-0"
8'-1"
7'-9 3/4"
PRODUCTS, LLC
P/N: 45AG P/N: 45AG1 P/N: 45AG2 P/N: 45AG3 P/N: 45AG4 P/N: 45AG5 OUR WRITTEN CONSENT.
SECTION P/N: KS157 SECTION P/N: KS158 SECTION P/N: KS159 SECTION P/N: KS160 SECTION P/N: KS161 SECTION P/N: KS162
BOLT KIT P/N: 45AJBK BOLT KIT P/N: BOLT KIT P/N: BOLT KIT P/N: 45AJBK BOLT KIT P/N: BOLT KIT P/N: SECTION ASSEMBLIES
45AJBK-5/16 45AJBK-5/16 45AJBK-5/16 45AJBK-5/16 45AG, AG1, AG2, AG3, AG4, & AG5
45AJBK-7/16 45AJBK-7/16 45AJBK-7/16 45AJBK-7/16
C760176 13
FILE NO.
25G GUY BRACKET ASSEMBLY GA25GD - BILL OF MATERIALS Standard-45G
ITEM QTY PART NO. DESCRIPTION REVISIONS
PRODUCTS
C870710 7
FILE NO.
Standard-90
REVISIONS
REV. DESCRIPTION DWN CHK APP
3 M.F JDM HA
4 J.K JDM HA
ANCHOR
WIRE SIZE TURNBUCKLE THIMBLE
ROD
GAR30 5/8TBE&J 5/16THH
GAC303,305
5/16 EHS
GAC3455 5/8TBE&J 7/16THH
GAC5655 5/8TBE&J
PRODUCTS
A871382 4
FILE NO.
Standard-80
REVISIONS
REV. DESCRIPTION DWN CHK APP
TO ACHIEVE MAXIMUM COVERAGE WITH THE END SLEEVE, THE APPLICATION SHOULD BE CONDUCTED IN THE FOLLOWING MANNER
DWG REFERENCE
9:07:10 AM
Mar/23/2006
1 2 3
PLACE THE SLOT SIDE OF THE DRIVE THE SLEEVE DOWNWARD UNTIL THE RODS OF THE LONG LEG
END SLEEVE OVER THE LONG THE RODS OF THE SHORT LEG ARE SHOULD BE EVEN WITH, OR
PRODUCTS
LEG OF THE DEAD END COMPLETELY COVERED MAY EXTEND ABOVE, THE TOP 6718 WEST PLANK ROAD
EDGE OF THE SLEEVE PEORIA, IL 61604
TOLL FREE 800-727-ROHN
B700607 3
FILE NO.
REVISIONS
REV. DESCRIPTION DWN CHK APP
ADDED 65GSR FOR GROUND KIT
3 ZAW JDM HA
GROUND WIRE ATTACHMENT CLAMP
DATE: 08/20/12
P/N: CPC1/1.25
20'
TYP
TOWER FOUNDATION 6.00" MIN.
(TYP) (152mm)
GROUND ROD
(TYP)
PRODUCTS
B090128 3
FILE NO.
REVISIONS
REV. DESCRIPTION DWN CHK APP
3 JEC KTL HA
PRODUCTS
PO BOX 5999
PEORIA, IL 61601-5999
TOLL FREE 800-727-ROHN
THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
OUR WRITTEN CONSENT.
B070996 3
FILE NO.
ROHN STANDARD BOLT ASSEMBLIES
1. ALL BOLTED CONNECTIONS ARE SNUG TIGHT CONNECTIONS REVISIONS
UNLESS PRESTRESSED BOLTS ARE INDICATED ON AN ASSEMBLY REV. DESCRIPTION DWN CHK APP
ADDED BOLT ASSEMBLY VIEWS
DRAWING.
9 JHY JDM HA
2. ROHN STANDARD BOLT ASSEMBLIES ARE ILLUSTRATED ON THE
DATE: 11/11/2019
ADJACENT INSTALLATION DETAILS. WHEN SPECIFIED BY THE
SNUG TIGHT BOLT
UP TO 1" DIA.
PRETENSIONED PURCHASER, OPTIONAL NUT-LOCKING DEVICES (TRI-LOC NUTS,
BOLT ANCO NUTS, OR LOCK WASHERS) ARE PROVIDED AS A
(SEE NOTE #3)
SUBSTITUTE FOR PAL NUTS FOR SNUG TIGHT CONNECTIONS
(REFER TO SHEET 2 FOR INSTALLATION DETAILS).
3. TRI-LOC NUTS ARE PROVIDED AS STANDARD NUT-LOCKING
DEVICES FOR SNUG TIGHT BOLTS GREATER THAN 1 INCH
DIAMETER. ANCO NUTS ARE SUBSTITUTED FOR TRI-LOC NUTS
NUT NUT WHEN SPECIFIED BY THE PURCHASER.
PAL NUT
(NUT-LOCKING
4. PRETENSIONED BOLTS ARE PROVIDED AS AN ASSEMBLY
DEVICE) INCLUDING THE BOLT, NUT AND REQUIRED WASHERS AND
ARE TO BE USED, UNLESS OTHERWISE NOTED, FOR ALL
DOUBLE ANGLE CONNECTIONS AND OTHER CONNECTIONS
NOTED ON AN ASSEMBLY DRAWING. A NUT-LOCKING
DEVICE IS NOT REQUIRED OR PROVIDED FOR
PRETENSIONED BOLT ASSEMBLIES.
WASHERS
BOLT ASSEMBLY SUFFIX "GA" BOLT ASSEMBLY SUFFIX "GPT1" 5. WASHERS ARE PROVIDED TO COVER ALL OVERSIZED HOLES AND
(SNUG TIGHT BOLT, NUT, & PAL NUT) (PRETENSIONED BOLT & NUT) EXPOSED SLOTS. WHEN AN OVERSIZED HOLE OR EXPOSED SLOT
IS PRESENT ON BOTH SIDES OF A CONNECTION, A WASHER IS
REQUIRED UNDER THE BOLT HEAD AND THE NUT AND THE BOLT
SHORTAGES OF NUT-LOCKING ASSEMBLY SUFFIX IN THE ASSEMBLY DRAWING BOM WILL
REFER TO SHEET 2 FOR DEVICES MAY OCCUR IF USED INCLUDE AN ADDITIONAL “W”.
NUT-LOCKING DEVICE OPTIONS ON PRETENSIONED BOLT 6. WASHERS ARE ALSO PROVIDED TO INCREASE THE GRIP
ASSEMBLIES. THICKNESS WHEN REQUIRED TO PREVENT THE NUT FROM
BOTTOMING OUT ON THE BOLT THREADS.
7. FOR SLOTTED GUSSET PLATE CONNECTIONS, WASHERS ARE
SNUG TIGHT BOLT ONLY REQUIRED FOR SINGLE ANGLE MEMBERS (SLOT
PRETENSIONED
UP TO 1" DIA.
(SEE NOTE #3)
BOLT EXPOSED ON ONE SIDE). WASHERS ARE NOT REQUIRED
OR PROVIDED FOR DOUBLE ANGLE CONNECTIONS (SLOT IS
NOT EXPOSED).
OVERSIZED HOLE OVERSIZED HOLE THE EDGE LIP OUT (SEE ADJACENT INSTALLATION DETAILS). TOLL FREE 800-727-ROHN
OR SLOT OR SLOT 11. WHEN LOCK WASHERS ARE SUBSTITUTED FOR PAL NUTS, THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
GRIP GRIP REPLACE ANY DAMAGED LOCK WASHERS DUE TO OUR WRITTEN CONSENT.
OVERTIGHTENING.
BOLT ASSEMBLY SUFFIX "GAW" BOLT ASSEMBLY SUFFIX "GPT"
ROHN STANDARD
SLOT ON ONE SIDE OR NARROW GRIP SLOT ON ONE SIDE OR NARROW GRIP PRETENSIONED BOLT ASSEMBLY INSTALLATION BOLT ASSEMBLY INSTALLATIONS
(SNUG TIGHT BOLT, WASHER, NUT, & PAL NUT) (PRETENSIONED BOLT, WASHER, & NUT) 12. PRETENSIONED BOLT ASSEMBLIES, UNLESS OTHERWISE NOTED,
SHALL BE TIGHTENED IN ACCORDANCE WITH THE AISC DWN: CHK'D: DATE:
TURN-OF-NUT PRETENSIONING METHOD USING THE FOLLOWING OH GHB 07/05/1979
NUT ROTATIONS FROM THE SNUG TIGHT CONDITION: 1/3 TURN ENG'R: SHEET #:
SNUG TIGHT BOLT FOR BOLT LENGTHS UP TO 4 TIMES THEIR DIAMETER AND 1/2
TWS 1 OF 2
PAL NUT 13. LOCK WASHERS SHALL NOT BE USED WITH PRETENSIONED BOLT DRAWING NO: REV:
ASSEMBLIES. A790135 9
FILE NO.
REVISIONS
REV. DESCRIPTION DWN CHK APP
ADDED BOLT ASSEMBLY VIEWS
9 JHY JDM HA
DATE: 11/11/2019
LOCK WASHER
TRI-LOC NUT ANCO NUT
(NUT-LOCKING
(NUT-LOCKING (NUT-LOCKING
DEVICE)
DEVICE) DEVICE)
NUT
BOLT ASSEMBLY SUFFIX "GA-TLN" BOLT ASSEMBLY SUFFIX "GAAN" BOLT ASSEMBLY SUFFIX "GALW"
(SNUG TIGHT BOLT & TRI-LOC NUT) (SNUG TIGHT BOLT & ANCO NUT) (SNUG TIGHT BOLT, LOCK WASHER, & NUT)
PO BOX 5999
PEORIA, IL 61601-5999
TOLL FREE 800-727-ROHN
OVERSIZED HOLE OVERSIZED HOLE OVERSIZED HOLE
OR SLOT OR SLOT OR SLOT THIS DRAWING IS THE PROPERTY OF ROHN. IT IS NOT TO BE
REPRODUCED, COPIED OR TRACED IN WHOLE OR IN PART WITHOUT
GRIP GRIP GRIP OUR WRITTEN CONSENT.
BOLT ASSEMBLY SUFFIX "GAW-TLN" BOLT ASSEMBLY SUFFIX "GAWAN" BOLT ASSEMBLY SUFFIX "GAWLW"
ROHN STANDARD
SLOT ON ONE SIDE OR NARROW GRIP SLOT ON ONE SIDE OR NARROW GRIP SLOT ON ONE SIDE OR NARROW GRIP BOLT ASSEMBLY INSTALLATIONS
(SNUG TIGHT BOLT, WASHER, & TRI-LOC NUT) (SNUG TIGHT BOLT, WASHER, & ANCO NUT) (SNUG TIGHT BOLT, WASHER, LOCK WASHER, & NUT)
DWN: CHK'D: DATE:
OH GHB 07/05/1979
ENG'R: SHEET #:
SNUG TIGHT BOLT SNUG TIGHT BOLT SNUG TIGHT BOLT PRJ. ENG'R:
TWS 2 OF 2
PRJ. MANG'R:
A790135 9