0.3 A 3.50 3.

50 NOTES:
0 0.30 0.30
3.20 3.20
GENERAL
1.All dimensions are in mm unless otherwise
200mm masomry 300x300mm RC walling
@ 3.5m CC
specified.
boundary wall

B B
2.Dimensions to be read, not scaled.Only
A TYPICALPLAN figured dimensions to be used.
pv pv pv pv pv
pv pv pv pv pv pv 3.Contractor to check and verify all
dimensions on site before commencement
25mm PCC coping
Plaster & paint
of any works.
RC Column ,
CONSTRUCTION
Machine cut stone with
gl gl
horizontal key
1.All slabs at ground level to be poured over
gl gl
APPROACH ELEVATION 1000 gauge polythene sheeting on 50 mm
SIDE ELEVATION S(--) 03
thick murram bliding layer which on 300
hardcore fill.
RC footing, depth to be
TYPICAL ELEVATION det on site 2.All soil under slabs and all around external
TYPICAL SECTION foundations to be treated against termites.

STRUCTURAL.
600x400mm
cover and frame
1.All black cotton soil to be removed from
600x450mm MH
150mm r.c cover slab
pv pv pv
cover & frame

pv pv pv pv pv pv
GL
Intlet
GL
GL GL below all building and paved surfaces.
pv pv MH 120mm thick r.c
100 cover slab
140mm masonry wall
Outlet 12,000
2.All soil under slabs and all around external

300

600
MH
Inlet

500
Concrete

3,600
300

500
Invert level of ratio 1:3:6
foundations to be treated against termites.

150
incoming drain To curb soil GL GL
100 erosion

F1

F2
10mm thick water E 200mm diameter hardcore

2.Building to be clear of black cotton soil


190mm thick masonry proof rendering
stone /loose ground or
walling with 10mm
150mm thick
rendering on both sides where speified
base slab

SECTION A/1
150mm thick
base slab
1.Cover slab to be reiforced with
10mm diameter bars at 100mm c/c within 3m outside the perimeter wall.
gl gl gl gl SECTION A/2
SOAK PIT SECTION (conc. 20/20 mix 1:2:4
3.For all R.C works,refer to structural
2.Base slab to be conrete
SIDE ELEVATION S(--) 02 REAR ELEVATION S(--) 04
A/2
class Q mix 1:3:6

200
3.Outlet and Inlet pipes to drawings.

200 100
be 100mm diameter cast iron
4.Depth of foundation to be determined on the

1,600
600
A/1
4.Scum buffle to be 100mm thick

E
Inlet
reinforced with 2 No.100mm at both

100 200
A B C

D
NB
1. Soak pit to be used on
ends conc.80(20)
site to structural Engneers Approval.

200
200 800 200 200 800 200 12mm diameter
5.Dividing wall to be 100mm
5,600 soils with good absorption e.g MS bars @ 150mm

PLAN
sand,red soil e.t.c
2.Depth to be specified on site
c/c both ways
thick conc. class 20(20) reiforced
with weld mesh No. 65.
MECHANICAL.
SOAK PIT PLAN

manicured lawn
Manhole cover & frame to
1.All plumbing and drainage to comply with
manicured lawn
BS 497 & BS 556
GL GL

Step iron at
local authority regulations.
manicured lawn
300mm c/c
B/B

1,000 max.
DESLUDGING DIMENSIONS(m m)
Top of concrete
benching

TYPE
CAPACITY
(LITRES)
No.OF
PERSONS
INTERVALS
(YEARS) A B C D E F1 F2
2.All service ducts to be accessible from all

140
A 3,000 10 2 800 1,000 1,000 3,000 800 1,2 0 0 1,400

floors .

140 650
A/A B 6,000 20 2 800 1,400 1,200 3,600 1,400 1,5 0 0 1,400

930
SECTION A/A C 9,000 30 2 800 1,400 1,200 3,600 1,800 1,5 0 0 1,400

30'-4"
D 12,000 40 2 800 1,600 1,400 4,000 2,000 1,5 0 0 1,300

3.SVP denotes soil vent pipe to be provided


GL GL
E 15,000 50 2 800 1,600 1,400 4,000 2,400 1,5 0 0 1,200
140 900 140
8mm diameter F 22,500 100 1.5 800 3,600 1,800 5,600 3,000 1,8 5 0 1,500
1,180 @ 80mm c/c
G 45,000 200 1.5 800 5,600 2,800 8,600 3,600 2,040 1,500
INSPECTION CHAMBER PLAN 12mm rendering
(1:1)
H 67,500 300 1.5 800 7,600 3,800 11,600 4,000 2,260 1,500

SEPTIC I 90,000 400 1.5 800 8,800 4,400 13,400 4,600 2,380 1,500
at the head of the drainage.
TANK SECTION B/B 4.P.V permanent ventilation,to be provided on
PARKING

PARKING

manicured lawn

PROPOSED
SEPTIC TANK DETAILS

all doors and windows except bathroom and


50'

50'

50'

50'

DEVELOPMENT water closet doors.


5.All underground foul and waste drain pipes

shall be upvc to comply with Bs 5255.


6.All inspection chamber covers and framing

shall be cast iron to comply with Bs 497 table


86'-11"

19'-8"
2 grade A.
DSQ 7.The storm drain pipe to comply with Bs
MAIN
GATE 556 minimum slope in the drain pipes in 1%.
manicured lawn manicured lawn
8.All testing of pipes must be done before
S-05

S-03

plastering.
SITE PLAN prefix description date
S-01

19,500
200 800 200 5,800 200 2,000 200 3,100 200 3,200 200 3,200 200
1,000 6,000 2,400 3,100 3,600 3,400
1,000 875 750 3,700 675 600 1,200 600 800 1,500 800 1,050 1,500 1,050 700 1,800 900
900

200

200

pv pv ROOF PLAN
200
800

800

800

800

800
200
600

600

600
500

pv pv pv pv

BOYS
3,600

950
200

200

200

200

200

200

BEDROOM 30°
200 5,800 200 2,000 200 3,100 200 3,200 200 3,200 200 CLIENT:
1,500

750

pv pv DAN OCHOLA NYALELE


2,800

4,000
3,200

PRAYER/ GUEST

2,517
LOUNGE P.O.Box 259 - 40405,

346
STUDY BEDROOM
4,800

RONGO,KENYA.
5,000

MASTER
1,600

ROOM
800

4,600

4,600

4,600

4,600
200

200

BEDROOM

1,478
200
200

pv
CLIENT'S SIGNATURE: Date:
1,500

843
pv pv
750

pv pv

300
1,600

1,600

1,200

1,200

PASSAGE HALLWAY pv
.................................................................................
pv
950

WALL SPECIFICATION
11,200

11,200
600 600

pv pv
200

200

300

300
200mm machine dressed stone wall
300 200

pv PROJECT TITLE:
200

200

200

200

200
1,200

300
pv 1:3 cement/sand mortar, Horizontally plastered and PROPOSED RESIDENTIAL
MASTER pointed square joints, 200 mm bituminous
KITCHEN STORE

1,500
painted wall DEVELOPMENT ON
2,400
200
3,000

3,000

EN-SUITE LOUNGE
2,600

2,600

GIRLS felt d.p .c,25 mm hoop iron for walls less PASSAGE
2,400

ENTRY
3,400

to approval Plot L.R No. ___________________


600

pv DINING KITCHEN ft DINING


BEDROOM
2,400
than 200 mm thick.12mm thick flexcell
3,700

PORCH
1,800

2,100
300

SHO
3,700

3,700

expansion joints filler where applicable


200

WC DRAWING TITLE:
700 600 600

pv with approved hoizontal key pointing

900
GROUND FLOOR PLAN,SITE PLAN,
200

200

200

pv 15 mm thick plaster.
200

GT ELEVATIONS,SECTION,SEPTIC TANK
1,100
1,300

1,300

gl gl
200 500

pv pv pv AND BOUNDARY WALL DETAILS


200
500

500
700

200
200

pv pv pv
pv smooth
200

200

200
1,300

1,300

1,300

1,300
1,500

1,500

1,500

1,500

1,500

IC IC KITCHEN YARD IC rendered wall Date: MAR. 2022 Scale- 1:100, 1:75
4,600 FLOOR SLAB to approval Drawn by: bEnJiE
200

100mm r.c slab mix 1 : 2 : 4 to S.E 's details


200
200

200

IC on A66 B .R .C meshwire on 1 layer of


480 IC 120 100 300 200 100 500
STRIP FOUNDATION SPECS 500swg polythene d.p .m,300mm overlap consultant:
1,000 200 1,400 800 1,800 700 1,500 900 900 1,100 1,100 950 1,500 950 1,200 600 1,100
200 100 S-02 200mm natural stone walling on50 mm sand blinding on 300 mm well
200 2,400 200 3,000 200 2,900 100 1,200 1,100 1,100 200 3,000 200 2,200 200 800 200 on 600x200mm wide conc . strip compacted approved hardcore on firm
1,000 1,600 3,300 4,400 2,500 3,200 2,400 1,100 foundation footing to S,E's details ground free from black cotton soil
19,500 Column footings to S.E ' s details, treated with approved insecticide .
S-01

Foundation depth to be Signature......................date.....................


GROUND FLOOR PLAN determined on site
S-03
S-05

GSPublisherEngine 0.11.100.100