50 NOTES:
0 0.30 0.30
3.20 3.20
GENERAL
1.All dimensions are in mm unless otherwise
200mm masomry 300x300mm RC walling
@ 3.5m CC
specified.
boundary wall
B B
2.Dimensions to be read, not scaled.Only
A TYPICALPLAN figured dimensions to be used.
pv pv pv pv pv
pv pv pv pv pv pv 3.Contractor to check and verify all
dimensions on site before commencement
25mm PCC coping
Plaster & paint
of any works.
RC Column ,
CONSTRUCTION
Machine cut stone with
gl gl
horizontal key
1.All slabs at ground level to be poured over
gl gl
APPROACH ELEVATION 1000 gauge polythene sheeting on 50 mm
SIDE ELEVATION S(--) 03
thick murram bliding layer which on 300
hardcore fill.
RC footing, depth to be
TYPICAL ELEVATION det on site 2.All soil under slabs and all around external
TYPICAL SECTION foundations to be treated against termites.
STRUCTURAL.
600x400mm
cover and frame
1.All black cotton soil to be removed from
600x450mm MH
150mm r.c cover slab
pv pv pv
cover & frame
pv pv pv pv pv pv
GL
Intlet
GL
GL GL below all building and paved surfaces.
pv pv MH 120mm thick r.c
100 cover slab
140mm masonry wall
Outlet 12,000
2.All soil under slabs and all around external
300
600
MH
Inlet
500
Concrete
3,600
300
500
Invert level of ratio 1:3:6
foundations to be treated against termites.
150
incoming drain To curb soil GL GL
100 erosion
F1
F2
10mm thick water E 200mm diameter hardcore
SECTION A/1
150mm thick
base slab
1.Cover slab to be reiforced with
10mm diameter bars at 100mm c/c within 3m outside the perimeter wall.
gl gl gl gl SECTION A/2
SOAK PIT SECTION (conc. 20/20 mix 1:2:4
3.For all R.C works,refer to structural
2.Base slab to be conrete
SIDE ELEVATION S(--) 02 REAR ELEVATION S(--) 04
A/2
class Q mix 1:3:6
200
3.Outlet and Inlet pipes to drawings.
200 100
be 100mm diameter cast iron
4.Depth of foundation to be determined on the
1,600
600
A/1
4.Scum buffle to be 100mm thick
E
Inlet
reinforced with 2 No.100mm at both
100 200
A B C
D
NB
1. Soak pit to be used on
ends conc.80(20)
site to structural Engneers Approval.
200
200 800 200 200 800 200 12mm diameter
5.Dividing wall to be 100mm
5,600 soils with good absorption e.g MS bars @ 150mm
PLAN
sand,red soil e.t.c
2.Depth to be specified on site
c/c both ways
thick conc. class 20(20) reiforced
with weld mesh No. 65.
MECHANICAL.
SOAK PIT PLAN
manicured lawn
Manhole cover & frame to
1.All plumbing and drainage to comply with
manicured lawn
BS 497 & BS 556
GL GL
Step iron at
local authority regulations.
manicured lawn
300mm c/c
B/B
1,000 max.
DESLUDGING DIMENSIONS(m m)
Top of concrete
benching
TYPE
CAPACITY
(LITRES)
No.OF
PERSONS
INTERVALS
(YEARS) A B C D E F1 F2
2.All service ducts to be accessible from all
140
A 3,000 10 2 800 1,000 1,000 3,000 800 1,2 0 0 1,400
floors .
140 650
A/A B 6,000 20 2 800 1,400 1,200 3,600 1,400 1,5 0 0 1,400
930
SECTION A/A C 9,000 30 2 800 1,400 1,200 3,600 1,800 1,5 0 0 1,400
30'-4"
D 12,000 40 2 800 1,600 1,400 4,000 2,000 1,5 0 0 1,300
SEPTIC I 90,000 400 1.5 800 8,800 4,400 13,400 4,600 2,380 1,500
at the head of the drainage.
TANK SECTION B/B 4.P.V permanent ventilation,to be provided on
PARKING
PARKING
manicured lawn
PROPOSED
SEPTIC TANK DETAILS
50'
50'
50'
19'-8"
2 grade A.
DSQ 7.The storm drain pipe to comply with Bs
MAIN
GATE 556 minimum slope in the drain pipes in 1%.
manicured lawn manicured lawn
8.All testing of pipes must be done before
S-05
S-03
plastering.
SITE PLAN prefix description date
S-01
19,500
200 800 200 5,800 200 2,000 200 3,100 200 3,200 200 3,200 200
1,000 6,000 2,400 3,100 3,600 3,400
1,000 875 750 3,700 675 600 1,200 600 800 1,500 800 1,050 1,500 1,050 700 1,800 900
900
200
200
pv pv ROOF PLAN
200
800
800
800
800
800
200
600
600
600
500
pv pv pv pv
BOYS
3,600
950
200
200
200
200
200
200
BEDROOM 30°
200 5,800 200 2,000 200 3,100 200 3,200 200 3,200 200 CLIENT:
1,500
750
4,000
3,200
PRAYER/ GUEST
2,517
LOUNGE P.O.Box 259 - 40405,
346
STUDY BEDROOM
4,800
RONGO,KENYA.
5,000
MASTER
1,600
ROOM
800
4,600
4,600
4,600
4,600
200
200
BEDROOM
1,478
200
200
pv
CLIENT'S SIGNATURE: Date:
1,500
843
pv pv
750
pv pv
300
1,600
1,600
1,200
1,200
PASSAGE HALLWAY pv
.................................................................................
pv
950
WALL SPECIFICATION
11,200
11,200
600 600
pv pv
200
200
300
300
200mm machine dressed stone wall
300 200
pv PROJECT TITLE:
200
200
200
200
200
1,200
300
pv 1:3 cement/sand mortar, Horizontally plastered and PROPOSED RESIDENTIAL
MASTER pointed square joints, 200 mm bituminous
KITCHEN STORE
1,500
painted wall DEVELOPMENT ON
2,400
200
3,000
3,000
EN-SUITE LOUNGE
2,600
2,600
GIRLS felt d.p .c,25 mm hoop iron for walls less PASSAGE
2,400
ENTRY
3,400
PORCH
1,800
2,100
300
SHO
3,700
3,700
WC DRAWING TITLE:
700 600 600
900
GROUND FLOOR PLAN,SITE PLAN,
200
200
200
pv 15 mm thick plaster.
200
GT ELEVATIONS,SECTION,SEPTIC TANK
1,100
1,300
1,300
gl gl
200 500
500
700
200
200
pv pv pv
pv smooth
200
200
200
1,300
1,300
1,300
1,300
1,500
1,500
1,500
1,500
1,500
IC IC KITCHEN YARD IC rendered wall Date: MAR. 2022 Scale- 1:100, 1:75
4,600 FLOOR SLAB to approval Drawn by: bEnJiE
200
200