FACADE INSULATION BOARD TP 435 B


SCOPE DESCRIPTION
The TP 435 B facade insulation board made of glass wool
with ECOSE® Technology in WLS 035 is used for thermal,
sound and fire protection in ventilated, non-transparent
facades. It is laminated on one side with black glass
fleece, is inherently non-combustible and water-repellent
throughout.

TECHNICAL DATA ADVANTAGES

Rated value of thermal 0.035 W/(m∙K) (DIN 4108-4)


+ Made with ECOSE® Technology
c o n d u c t i v i t y (λB) + Laminated with black glass fleece on one side
Fire behavior A1 (DIN EN 13501) Designation code + Water repellent throughout
MW-EN 13162-T4-WS-WL(P)-AFr10
+ Non-combustible

Designation Characters Description/Data Unit Norm


Material Glass wool

Temperature resistance 150 °C

Glow behavior No tendency to continuous smoldering DIN EN 16733

Thermal conductivity level WLS 035

Nominal value of thermal conductivity λD


0,034 W/(m∙K) DIN EN 13162

Specific heat capacity cp


850 J/(kg∙K)
Water vapor diffusion resistance number μ approx. 1 DIN EN 12086

Length-related flow resistance AFr


10 kPa*s/m² DIN EN 29053

Limit dimensions thickness T T4 DIN EN 13162

Water absorption during brief, partial immersion WS fulfills DIN EN 1609

Water absorption during long-term, partial immersion WL(P) fulfills DIN EN 12087

Hydrophobing yes

Coating and clothing laminated on one side with black glass fleece.

Thickness d 40 60 80 100 120 140 160 180 200 mm

Nominal value of the thermal resistance RD


1,15 1,75 2,35 2,90 3,50 4,10 4,70 5,25 5,85 (m²K)/W DIN EN 13162

Design value of the thermal resistance R 1,14 1,71 2,29 2,86 3,43 4,00 4,57 5,14 5,71 (m²K)/W DIN 4108-4

CERTIFICATES
www.knaufinsulation.de

FACADE INSULATION BOARD TP 435 B

ADDITIONAL
INFORMATION
Application
Ventilated, non-transparent facades as well as in double-skin masonry with air layer without height limitation. Application abbreviation
according to DIN 4108-10: WAB WZ

Processing
Please observe the respective processing guidelines. In addition, the relevant standards and the recognized rules of technology apply.

Thick Lengt Width m2/package m2/pallet Item number


ness h (mm)
(mm) (mm)
40 1250 600 12,00 288,00 704507
60 1250 600 7,50 180,00 704509
80 1250 600 6,00 144,00 704510
100 1250 600 4,50 108,00 704511
120 1250 600 3,00 72,00 704512
140 1250 600 3,00 72,00 704513
160 1250 600 3,00 72,00 704514
180 1250 600 2,25 54,00 704515
200 1250 600 2,25 54,00 704516
Delivery condition: plate, packing: PE shrinkffolie,
Waste code number: 170604,

The product is sold through specialized dealers.

Knauf Insulation GmbH


Heraklithstraße 8, 84359 Simbach am Inn, Germany

Customer service: +49 8571 40-0 Technical Hotline: +49 8571 40-380 Membership no.: 31763 www.knaufinsulation.de/ausschreibungstexte

Subject to technical changes. The respective current edition applies. The information contained herein corresponds to our current state of the art. The generally recognized rules of construction
technology, relevant standards, guidelines and rules of craftsmanship must be observed by the person carrying out the work in addition to the processing instructions. Our warranty only refers to the flawless quality
of our material. Consumption, quantity and execution data are empirical values which cannot be transferred without further ado in the event of deviating circumstances. All rights reserved. Changes, reprinting
and photomechanical as well as electronic reproduction, also in extracts, require express approval.
14.12.2020