CLAMPING PLATE KP-040/HB


SCOPE DESCRIPTION
The KP-040/HB rock wool clamping panel in WLS 039
has been specially developed for thermal, acoustic
and
Fire protection in timber frame construction with a grid
dimension of 62.5 cm and a timber stud width of 6 cm.
The insulation boards have a minimum raw density of
≥ 30 kg/m³ and are suitable for classified fire protection constructions.

TECHNICAL DATA ADVANTAGES


+ Format for timber frame construction in grid size 62.5 cm
Rated value of the 0.039 W/mK (DIN 4108-4)
Thermal conductivity λB + For classified fire protection structures
Fire behavior A1, (DIN EN 13501-1) + Minimum bulk density 30 kg/m³
Designation key MW-EN 13162-T4-AFr5

Designation Characters Description/Data Unit Norm


Material - Rock wool - -

Melting point - ≥ 1000 °C DIN 4102

Temperature resistance - ≤ 250 °C DIN 4102-17

Glow behavior - No tendency to continuous smoldering - DIN EN 16733

Nominal value of thermal conductivity λD


0,038 W/mK DIN EN 13162
cp
Specific heat capacity 1030 J/(kg∙K) DIN EN 12524

Water vapor diffusion resistance number μ approx. 1 - DIN EN 13162


AFr
Length-related flow resistance ≥5 kPa*s/m² DIN EN 29053

Limit dimensions thickness T T4 - DIN EN 13162

Thickness d 80 100 mm -
RD
Nominal value of the thermal resistance 2,10 2,60 (m²K)/W DIN EN 13162

Design value of the thermal resistance R 2,05 2,56 (m²K)/W DIN 4108-4

CERTIFICATES

Knauf Insulation mineral wool fibers are harmless to health. This is guaranteed by the RAL quality mark.
www.knaufinsulation.de

CLAMPING PLATE KP-040/HB

ADDITIONAL
INFORMATION
Application
Areas of applicationFor thermal and sound insulation as well as fire protection in wood construction. Insulation between rafters and wooden beams; F30
c o n s t r u c t i o n s according to test certificate P-MPA-E-99-092 with rafter or beam spacings of up to 87 cm - regardless of the cladding on the
room side. Insulation between wooden studs of exterior walls and partition walls in timber frame construction as well as for classified fire protection
constructions according to DIN 4102-4. Application abbreviation according to DIN 4108-10: DZ, WH, WTR

Processing
Please observe the respective processing guidelines. In addition, the relevant standards and the recognized rules of technology apply.

Thick Lengt Width Piece/package m2/package m2/pallet Item number


ness h (mm)
(mm) (mm)
80 1200 575 12 5,52 66,24 2417028

100 1200 575 12 4,14 49,68 2417025


Packaging: Large volume packaging available,
Waste code number: 170604,

The product is sold through specialized dealers.

Knauf Insulation GmbH


Heraklithstraße 8, 84359 Simbach am Inn, Germany

Customer service: +49 8571 40-0 Technical Hotline: +49 8571 40-380 Membership no.: 31763 www.ausschreiben.de/katalog/knauf_insulation

All technical data given in this document have been reproduced to the best of our knowledge and belief. They must be adapted to the respective construction situation. Make sure that you use the latest edition of
this information. The responsibility for professional and proper installation and compliance with building regulations rests with the planner and building contractor. Despite the greatest possible care, we accept no
liability for the topicality, correctness, completeness or quality of the information provided. Furthermore, the valid standards and recognized rules of technology apply. Knauf Insulation is grateful for any
suggestions for improvement or information on possible errors.
25.06.2020

You might also like