You are on page 1of 3

Types of Overcurrent

Relays and Their


Application
Overcurrent Monitoring Relay
A current monitoring relay is used for the type of relay that will protect against excessive
current, either caused by an electrical fault or some other type of overcurrent condition.
But faults can be either high current or low current. And while many current monitoring
relays can detect both, some will only sense one type of current or the other.
An overcurrent monitoring relay is placed in line with the circuit it is to protect. If the current
in the circuit being monitored rises above the threshold set on the overcurrent relay, then the
relay will “trip” and open the circuit. This prevents damage to equipment or injuries to
people.

Types of Overcurrent Relays


There are several different types of overcurrent relays available on today’s market. These will
mostly differ in their features and functions, but some also differ in terms of how they are
designed and what type of overcurrent they are meant to protect against. The overcurrent
relay types are:

1. Instantaneous Overcurrent Relay


The first type of overcurrent relay is the instantaneous overcurrent relay. This type of relay is
designed to protect against very high levels of current for a very short period of time (less
than 0.1 seconds). These types of currents can be caused by faults in the system, such as a
short circuit.
The instantaneous overcurrent relay will have a very low time delay, meaning that it will trip
or open the circuit as soon as the current is detected. This is important, as it can help to
prevent damage to the electrical system by quickly removing the source of the overcurrent.
Applications for these types of overcurrent relays include outgoing feeders, busbars, and
transformers. In these applications, the instantaneous overcurrent relay can provide protection
against faults that could otherwise cause extensive damage.
2. Inverse Time Overcurrent Relay
The second type of overcurrent relay is the inverse time overcurrent relay. Unlike the
instantaneous overcurrent relay, the operating time is, as the name suggests, inversely
proportional to the current magnitude.
That means a high current will reduce the amount of time it takes for the relay to operate,
while a lower current will result in a longer operating time, as long as 10 seconds. This is
important, as it can help to prevent false trips when there is only a momentary surge of
current.
When it comes to application, these types of overcurrent relays are mostly used in
distribution lines. Inverse time overcurrent relays are further classified as inverse definite
time relay, very inverse relay, and extreme inverse relay based on their time delay
characteristics.

Normal Inverse Time Overcurrent Relay


These types of overcurrent relays offer a lower or smaller change in the operating time as the
current magnitude changes. They are, therefore, often used industrial situations and utility
systems.

Very Inverse Time Overcurrent Relay


A very inverse time overcurrent relay will have a much greater change in the operating time
as the current magnitude changes than the normal inverse time overcurrent relay. They are,
therefore, well-suited for use in applications where the fault current is expected to be lower.

Extremely Inverse Time Overcurrent Relay


An extremely inverse time overcurrent relay has the greatest change in operating time as the
current magnitude changes of all the inverse time overcurrent relays. They are, therefore,
much faster to respond to fault situations. These types of overcurrent relays are commonly
used to prevent protecting cables, motors, transformers, and other equipment such as heaters
and pumps from overheating.

Long Time Inverse Overcurrent Relay


Based on its name, you can easily tell that the long time inverse overcurrent relay has an
extremely long operating time. In fact, it can take up to 60 seconds for this type of relay to
operate.
That being said, the long time relay is not as sensitive as other types of overcurrent relays and
is, therefore, mostly used in installations where there is a low risk of faults. These overcurrent
relay types are mostly installed to protect against earth faults.
3. Definite Time Delay Overcurrent Relay
3. Definite Time Delay Overcurrent Relay
This type of relay is similar to the inverse time delay overcurrent relay, in that it only trips or
opens the circuit when the current is above a certain level for a specific amount of time.
However, the definite time delay overcurrent relay has a fixed or set time delay.
This means that the amount of time it takes for the relay to trip or open the circuit is always
the same, regardless of the level of current. This can usually be set by the user. These
overcurrent relay types operate independently of the amount of current, provided it’s above
the predetermined value.
Definite time overcurrent relay characteristics allow it to be used in applications such as
transmission lines and transformers where the tripping must happen after a specific time
delay.

4. Directional Overcurrent Relay


Directional overcurrent relays are commonly used to protect against faults in a system where
the current may flow in either direction. For example, they may be installed to respond to
faults in a ring main system.
Directional overcurrent relays are able to detect the direction of the current flow and will only
operate when the current is flowing in a certain direction. This helps prevent unnecessary
trips or circuit breaker operations in systems with several current paths or power sources.
Based on its operation, the directional overcurrent relay is used for protection of circuits in
these systems:

 Ring Main Unit (RMU)


 Radial Distribution System
 Generator Protection

The directional overcurrent relay can be used in conjunction with other relays to provide
complete protection for the system.

Conclusion
Overcurrent monitoring relays are essential devices when it comes to the protection of
electrical systems. They can help to prevent damage to equipment and components by
quickly removing the source of the overcurrent. There are several different types of
overcurrent relay. Each of these has its own unique benefits and best applications. Depending
on your type of application, you’ll need to select the right type of overcurrent relay to ensure
adequate protection.

You might also like