A B C D E F G H I J K L

KCC2-Z-945001
COMBINED PRE TREATMENT UNIT
CAPACITY = 77 Cu.Mtr./Hr.
MATERIAL = SS
1 1

1"-KCC2-AN-9450066-G01A1
KZ01-PR-PID-S6-89014-001
1"-KCC2-AN-9450010-G01A1
KZ01-PR-PID-S6-89018-001 FROM INSTRUMENT AIR
PACKAGE KCC2-Z-945002
FROM AIR BLOWER
KCC2-KF-945001A/B

KCC2-HV-9450003 KCC2-HV-9450012
1"-KCC2-WU-9450009-P01A1
SERVICE WATER
KCC2-HV-9450138 KCC2-AV-9450013 KCC2-AV-9450014
2
KZ01-CV-LAY-S6-5501-004 2

OTHERS OWATCO

6"-KCC2-DB-9450002-P01A1
TANKERED SEWAGE
KCC2-HV-9450001 KCC2-HV-9450004

NOTE-5
N3-1" N4-1" 10"x6"
N8-6" N5-10"
KCC2-HV-9450008 8"x10"
N2-10" KCC2-Z-945001
10"x6" 6"-KCC2-DB-9450008-P01A1
3
OTHERS OWATCO N6-10" KZ01-PR-PID-S6-89010-001 3

8"-KCC2-DB-9450007-P01A1
6"x10"
6"-KCC2-DB-9450001-P01A1 N1-10" N7-2" TO BALANCING TANK
KCC2-T-945001
RAW SEWAGE KCC2-HV-9450010
NOTE:7
KCC2-HV-9450002 KCC2-HV-9450009
KZ01-CV-LAY-S6-5601-004 6"-KCC2-DB-9450012-P01A1
8"-KCC2-DB-9450005-A01A1

6"-KCC2-DB-9450011-P01A1

SCREENED WASTE
KCC2-HV-9450011
8"x6" COLLECTION BIN TO DRAIN 6"-KCC2-DB-9450006-P01A1
KZ01-PR-PID-S6-89010-001
OTHERS OWATCO
TO BALANCING TANK
TE TIT KCC2-T-945001
4
4"-KCC2-DB-9450003-P01A1 01 001
LEACHATE KCC2-TI-9450001
3/4"
HOLD-1 KCC2-HV-9450005
HOLD:
pHI 1) DRAWING NUMBER SHALL BE ADVISED BY JACOBS.
001 2) DRAWING NUMBER SHALL BE ADVISED BY JACOBS.

pHI NOTE:
OTHERS OWATCO KCC2-PHI-9450001 1) FOR TYPE OF INSTRUMENTS PLEASE REFER INSTRUMENT LIST DOCUMENT : KZ01-IC-LST-S6-9001.
001
2) FOR SIGNAL PLEASE REFER CONTROL PHILOSOPHY DOCUMENT : KZ01-IC-PHI-S6-9001.
1/2" 3) FOR SYMBOL LEGENDS PLEASE REFER BP STANDARD SHEET Nos. KZ01-PR-PID-68-00005 TO 00023.
6"-KCC2-DB-9450004-P01A1
4) FOR GENERAL INSTRUCTION, SYMBOLS, NOMENCLATURE, DETAILS REFER LEGEND SHEETS.
KRC SEWAGE 5) COMBINED PRE-TREATMENT PLC PANEL (KCC2-ICP-9450002) SHALL BE INSTALLED IN
KCC2-HV-9450007 CONTAINER.PNEUMATIC VALVES SHALL BE OPERATED USING SIGNALS FROM PLC KCC2-ICP-9450002 EPC STP CONTRACTOR
HOLD-2 KCC2-HV-9450006 6) FOR SYMBOL LEGENDS PLEASE REFER THE DRAWING NO: KZ01-PR-PID-S6-89012-001/002 5
5
7) THE INDIVIDUAL SEWAGE LINES TAKEN TO THE TOP OF PRETREATMENT UNIT AND TERMINATED AT OWATCO
POST BOX.93, RUSAYL
THE INLET HEADER WHICH WILL BE PLACED ABOVE PRETREATMENT UNIT AND HENCE BACKFLOW POSTAL CODE 124
SULTANATE OF OMAN
SHALL BE AVOIDED. Projects
PROJECT TITLE
PROJECT NUMBER SECURITY CLASS. CREATED BY
P1401010 PROJECT INTERNAL OWATCO KHAZZAN-CONSOLIDATED-CAMP-BLOCK-61
TITLE
START DATE
THIS DRAWING AND/OR ITS CONTENTS, INFORMATION AND PRINCIPLES OF DESIGN ARE
THE EXCLUSIVE PROPERTY OF JACOBS AND IS SUBMITTED TO YOU, WITH THE
14.02.2015 P&I DRAWING FOR
AGREEMENT THAT IT IS NOT TO BE REPRODUCED IN ANY MANNER, COPIED OR SCALE
C01 04.08.2015 APPROVED FOR CONSTRUCTION AN JJ GS AS MODIFIED, NOR IS IT TO BE RELAYED IN PART OR IN WHOLE TO ANY OTHER FIRM OR
NDIVIDUAL FOR ANY OTHER PROJECT, EXCEPT BY WRITTEN AGREEMENT WITH JACOBS.
ACCEPTANCE OF THIS DRAWING WILL BE CONSTRUED AS AN AGREEMENT TO THIS
N.T.S. COMBINED PRE TREATMENT UNIT
STATEMENT. tde
6 B01 22.07.2015 APPROVED FOR USE AN JJ GS AS SIZE 6

A3
A01 14.02.2015 ISSUED FOR COMPANY REVIEW NR JJ GS AS
DRAWING No. SHEET No. REV
CLIENT
REV DATE REVISIONS DWN CHK DISP APPD
APPD KZ01-PR-PID-S6-89009 001 C01
A B C D E F G H I J K L

A3_border [Metric A3: 420x297] DO NOT SCALE. THIS DRAWING WAS GENERATED USING CAD AND MUST NOT BE ALTERED MANUALLY