1 EQUIPMENT USED
OP-51580 (2 m) When you start AutoID Network Navigator, it will automatically search for
the SR-LR1 on the network.
(*1) Chassis is 1753-A4, Power unit is 1756-PA72/C, CPU unit is 1756-L61, EIP Master unit is
1756-EN2T.
3 Change the settings to those of the desired fixed IP address.
[ETHERNET]
CHAPTER
2 CONNECTION METHODS
Ethernet cable
24V DC or
dedicated AC adapter
4 Click the “Start the setup wizard”, and set as shown below. 2 New module Registration
5 Send configuration
Click the send settings button in the upper right of AutoID Network
Navigator to send the settings to the SR-LR1.
Select module opens, then expand the tree and select the unit to register.
CHAPTER
CONFIGURING ROCKWELL
4 CONTROLLOGIX SERIES SETTINGS
The new module window opens. Select [Name] and [IP address]
and [Slot].
f. Configuration Settings
3 Registration of SR-LR1 to RSLogix5000 Assembly instance is 1(fixed) and Size is 0(fixed).
You can download the Tag Description CSV file on the WEB
(barcodereader.com). Once you receive this just save it to your computer,
then you will be ready to load it into your Allen-Bradley software. To do
this go to [Tool] ➞ [IMPORT] ➞ [Tags and Logic Comments] and choose
the file you were provided.
Once the new module is created click the [+] next to Communication and
select General Ethernet Module.
(ETHERNET-MODULE)
Set the CPU mode key of the CPU unit to “REM” (center position).
Select [Communications] ➞ [Who Active] from the RSLogix5000 window.
Sample code