You are on page 1of 31

Uji Laboratorium Material PT Riung Mitra Lestari

Site MGM, Kalimantan Tengah

HASIL PENGUJIAN
KIND OF TEST Sampel A Sampel B Sampel C Sampel D

A. PHYSICAL PROPERTIES
Natural Water
ω (%) 9,66 27,26 12,80 18,48
Content
Unit Weight  (gr/cm3) 1,71 1,76 1,46 1,66
Specific Gravity Gs 2,55 2,48 2,55 2,54
Liquid Limit LL (%) 23,11 29,31
Plastic Limit PL (%) Non Plastic 21,43 Non Plastic 25,56
Plasticity Index PI 1,69 3,75
Gradation by Sieve Analysis (% Passing)
# 10 2,000 mm 100,00 100,00 100,00 100,00
# 40 0,425 mm 99,94 99,94 99,86 99,87
# 200 0,075 mm 20,65 62,50 17,98 65,22
Soil Proportion by Gradation Curves (%)
Gravel 0,00 0,00 0,00 0,00
Sand 84,00 40,70 88,50 39,40
Silt 8,70 38,40 7,50 33,80
Clay 7,30 20,90 4,00 26,80
C. SOIL CLASSIFICATION
USCS ML CL ML ML

Hasil uji hanya berlaku untuk sampel material yang dikirim ke Laboratorium.
Pekerjaan Uji Laboratorium ini dilakukan dengan sebaik-baiknya sesuai standar pengujian
yang berlaku.

Banjarbaru, 19 Januari 2022


PT Tiyasa Total Rekayasa
Geotechnical Engineer,

Dr. Yusti Yudiawati, ST, MT


No SKA 1.2.216.2.031.09.1903080

PT Tiyasa Total Rekayasa | Geotechnical Research & Civil Solutions


LABORATORY TEST RESULT

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

NO. KIND OF TEST Sampel A

A. PHYSICAL PROPERTIES

1 Natural Water Content ω (%) 9,66


3
2 Unit Weight g (gr/cm ) 1,71
3 Specific Gravity Gs 2,55
4 Liquid Limit LL (%)
Plastic Limit PL (%) Non Plastic
Plasticity Index PI
5 Gradation by Sieve Analysis (% Passing) :
# 10 2,000 mm 100,00
# 40 0,425 mm 99,94
# 200 0,075 mm 20,65
6 Soil Proportion by Gradation Curves (%)
Gravel 0,00
Sand 84,00
Silt 8,70
Clay 7,30
B. SOIL CLASSIFICATION
1 USCS SM

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


WATER CONTENT, UNIT WEIGHT,
SPECIFIC GRAVITY TEST
Project : Uji Laboratorium Material PT Riung Mitra Lestari
Location : Site MGM, Kalimantan Tengah

Sample No. : Sampel A Date : 7-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

WATER CONTENT UNIT WEIGHT


(ASTM D2216-71; SNI 1965:2008) (ASTM D2937-71; SNI 03-3637-1994)

Container No. 1 2 Container No. 1 2


Cont. Weight + Wet Soil (gr) 77,56 76,01 W Ring + Wet soil (gr) 178,20 178,12
Cont. Weight + Dry Soil (gr) 71,69 70,19 W Ring (gr) 81,26 81,26
Water Weight (gr) 5,87 5,82 W wet soil (gr) 96,94 96,86
Container Weight (gr) 9,00 11,75 Diameter Ring (gr) 6,00 6,00
Weight Dry (gr) 62,69 58,44 H Ring (gr) 2,00 2,00
WATER CONTENT (%) 9,36 9,96 Volume (cm³) 56,52 56,52
Average (%) 9,66 Unit Weight (gr/cm³) 1,72 1,71
Average (gr/cm³) 1,71

SPECIFIC GRAVITY TEST


(ASTM D854-58; SNI 1964:2008)

Picnometer No. 1 2
W Picno, Wp (gr) 159,21 161,34
W Picno + Soil, W1 (gr) 261,95 263,71
W Picno + Soil + Water, W2 (gr) 718,99 721,24
W Picno + Water, W3 (gr) 656,52 658,80
Mix Of Temperatur Water + Soil (°C) 27,00 27,00
W4 (W1 - Wp) (gr) 102,74 102,37
Gs (at TºC) 2,55 2,56
Correction, A 0,9983 0,9983
Gs (at 20ºC) = Gs (at TºC) x A 2,55 2,56
Specific Gravity 2,55

Table: Temperatur Correction


T°C Correction T°C Correction T°C Correction
15 1,0009 21 0,9998 27 0,9983
16 1,0007 22 0,9996 28 0,9980
17 1,0006 23 0,9993 29 0,9977
18 1,0004 24 0,9991 30 0,9974
19 1,0002 25 0,9988 31
20 1,0000 26 0,9986 32

Table: Water Intencity (w)


T°C w T°C w T°C w
15 0,999129 21 0,998022 27 0,996544
16 0,998972 22 0,997800 28 0,996264
17 0,998804 23 0,997568 29 0,995976
18 0,998625 24 0,997327 30 0,995678
19 0,998435 25 0,997075 31
20 0,998234 26 0,996814 32

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


ATTERBERG LIMIT TEST
(ASTM D423-66; SNI 1967:2008)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel A Date : 11-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

LIQUID LIMIT PLASTIC LIMIT


Sample No. 1 2 3 4 Sample No. 1 2
Number of Bows Container No.
Container No. W cont + W wet soil (gr)
W cont + W wet soil (gr) W cont + dry soil (gr)
W cont + dry soil (gr) W water (2) - (3) (gr)
Non Plastic Non Plastic
W water (3) - (4) (gr) W Container (gr)
W Container (gr) W dry soil (3) - (5) (gr)
W dry soil (4) - (6) (gr) Water content (4)/(6)*100 (%)
Water content (5)/(7)*100 (%) Plastic limit (%)

Liquid Limit Graph Unified Classification


70 60
Water Content (%)

60 50

Plasticity Index (%)


CL CH
50 40

40 30
MH-OH
30 20

20 10
CL-ML
ML- ML-OL
10 0
1 10
25 100 0 10 20 30 40 50 60 70 80 90 100
Blows Liquid Limit (%)

Liquid Limit (LL) % Soil Classification


Plastic Limit (PL) %
- Non Plastic
Plasticity Index (PI) %

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel A Date : 8-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

SIEVE ANALYSIS
(ASTM C130-46; SNI 03-1968-1990)
Sieve W soil % Weight % Cumulative
No. Ø (mm) (gr) Retained Retained Passing
1 24,56 0,00 0,00 0,00 100,000
3/4 19,10 0,00 0,00 0,00 100,000
3/8 9,500 0,00 0,00 0,00 100,000
4 4,750 0,00 0,00 0,00 100,000
8 2,360 0,00 0,00 0,00 100,000
10 2,000 0,00 0,00 0,00 100,000
40 0,425 0,12 0,06 0,06 99,940
100 0,150 153,21 76,61 76,67 23,335
200 0,075 5,37 2,69 79,35 20,650
Pan
Total weight (gr) 200,00

HYDROMETER ANALYSIS
(ASTM D421-58 & D422-63; SNI 3423:2008)
Wt. Dry (gr) 50
Specific Gravity (Gs) 2,55
Meniscus Correction, Fm 1
Zero Reading Correction, Fz 4
Temperature Correction, Ft 1,900
Specifik Gravity Correction (a) 1,024
Temperature (T) 27
A 0,01327

Time Hydrometer True Fully Corrected Effective Particle


% refined Combined
(menit) Reading Reading Reading Depth L Diameter % passing
grain (mm)
R'h Rcp Rcl (cm) (mm)
0,25 42,0 39,9 43 9,30 0,0809 81,678 16,866 0,0167
0,5 39,0 36,9 40 9,80 0,0587 75,536 15,598 0,0121
1 35,0 32,9 36 10,45 0,0429 67,348 13,907 0,0089
2 30,0 27,9 31 11,30 0,0315 57,113 11,794 0,0065
5 27,0 24,9 28 11,80 0,0204 50,972 10,526 0,0042
15 22,0 19,9 23 12,60 0,0122 40,736 8,412 0,0025
30 19,0 16,9 20 13,10 0,0088 34,595 7,144 0,0018
60 17,0 14,9 18 13,45 0,0063 30,501 6,298 0,0013
240 11,0 8,9 12 14,40 0,0032 18,219 3,762 0,0007
1440 6,0 3,9 7 15,25 0,0014 7,984 1,649 0,0003
2880 4,0 1,9 5 15,55 0,0010 3,889 0,803 0,0002

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS
(GRADATION CURVES)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel A


Depth :-
Type : Disturbed Sampel

Gravel Sand Silt Clay D60 D30 D10 Cu Cc


0 84 8,7 7,3 - - - - -
0
Clay Silt Sand Gravel
Fine Medium Coarse
100

90

80

70

Percentage Passing (%)


60

50

40

30

20

10

0
0,000 0,001 0,010 0,100 1,000 10,000 100,000
Diameter (mm)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


LABORATORY TEST RESULT

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

NO. KIND OF TEST Sampel B

A. PHYSICAL PROPERTIES

1 Natural Water Content ω (%) 27,26


3
2 Unit Weight g (gr/cm ) 1,76
3 Specific Gravity Gs 2,48
4 Liquid Limit LL (%) 23,11
Plastic Limit PL (%) 21,43
Plasticity Index PI 1,69
5 Gradation by Sieve Analysis (% Passing) :
# 10 2,000 mm 100,00
# 40 0,425 mm 99,94
# 200 0,075 mm 62,50
6 Soil Proportion by Gradation Curves (%)
Gravel 0,00
Sand 40,70
Silt 38,40
Clay 20,90
B. SOIL CLASSIFICATION
1 USCS ML

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


WATER CONTENT, UNIT WEIGHT,
SPECIFIC GRAVITY TEST
Project : Uji Laboratorium Material PT Riung Mitra Lestari
Location : Site MGM, Kalimantan Tengah

Sample No. : Sampel B Date : 7-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

WATER CONTENT UNIT WEIGHT


(ASTM D2216-71; SNI 1965:2008) (ASTM D2937-71; SNI 03-3637-1994)

Container No. 1 2 Container No. 1 2


Cont. Weight + Wet Soil (gr) 76,34 79,35 W Ring + Wet soil (gr) 181,09 179,98
Cont. Weight + Dry Soil (gr) 55,91 72,54 W Ring (gr) 81,26 81,26
Water Weight (gr) 20,43 6,81 W wet soil (gr) 99,83 98,72
Container Weight (gr) 9,06 10,11 Diameter Ring (gr) 6,00 6,00
Weight Dry (gr) 46,85 62,43 H Ring (gr) 2,00 2,00
WATER CONTENT (%) 43,61 10,91 Volume (cm³) 56,52 56,52
Average (%) 27,26 Unit Weight (gr/cm³) 1,77 1,75
Average (gr/cm³) 1,76

SPECIFIC GRAVITY TEST


(ASTM D854-58; SNI 1964:2008)

Picnometer No. 1 2
W Picno, Wp (gr) 161,01 162,64
W Picno + Soil, W1 (gr) 263,70 265,27
W Picno + Soil + Water, W2 (gr) 718,98 721,51
W Picno + Water, W3 (gr) 657,80 659,90
Mix Of Temperatur Water + Soil (°C) 27,00 27,00
W4 (W1 - Wp) (gr) 102,69 102,63
Gs (at TºC) 2,47 2,50
Correction, A 0,9983 0,9983
Gs (at 20ºC) = Gs (at TºC) x A 2,47 2,50
Specific Gravity 2,48

Table: Temperatur Correction


T°C Correction T°C Correction T°C Correction
15 1,0009 21 0,9998 27 0,9983
16 1,0007 22 0,9996 28 0,9980
17 1,0006 23 0,9993 29 0,9977
18 1,0004 24 0,9991 30 0,9974
19 1,0002 25 0,9988 31
20 1,0000 26 0,9986 32

Table: Water Intencity (w)


T°C w T°C w T°C w
15 0,999129 21 0,998022 27 0,996544
16 0,998972 22 0,997800 28 0,996264
17 0,998804 23 0,997568 29 0,995976
18 0,998625 24 0,997327 30 0,995678
19 0,998435 25 0,997075 31
20 0,998234 26 0,996814 32

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


ATTERBERG LIMIT TEST
(ASTM D423-66; SNI 1967:2008)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel B Date : 11-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

LIQUID LIMIT PLASTIC LIMIT


Sample No. 1 2 3 4 Sample No. 1 2
Number of Bows 16 27 36 45 Container No. C.1 C.2
Container No. C1 C2 C3 C4 W cont + W wet soil (gr) 30,77 31,53
W cont + W wet soil (gr) 54,35 57,33 53,43 53,84 W cont + dry soil (gr) 27,19 27,52
W cont + dry soil (gr) 45,49 48,28 45,53 46,04 W water (2) - (3) (gr) 3,58 4,01
W water (3) - (4) (gr) 8,86 9,05 7,90 7,80 W Container (gr) 9,20 10,05
W Container (gr) 8,90 8,89 9,83 10,07 W dry soil (3) - (5) (gr) 17,99 17,47
W dry soil (4) - (6) (gr) 36,59 39,39 35,70 35,97 Water content (4)/(6)*100 (%) 19,90 22,95
Water content (5)/(7)*100 (%) 24,21 22,98 22,13 21,68 Plastic limit (%) 19,90 22,95

Liquid Limit Graph Unified Classification


60 60
Water Content (%)

50 50

Plasticity Index (%)


CL CH
40 40

30 30
23,11 MH-OH
20 20

10 10
CL-ML
ML- ML-OL
0 0
1 10
25 100 0 10 20 30 40 50 60 70 80 90 100
Blows Liquid Limit (%)

Liquid Limit (LL) % 23,11 Soil Classification


Plastic Limit (PL) % 21,43
ML Sandy silts of low plasticity
Plasticity Index (PI) % 1,69

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel B Date : 8-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

SIEVE ANALYSIS
(ASTM C130-46; SNI 03-1968-1990)
Sieve W soil % Weight % Cumulative
No. Ø (mm) (gr) Retained Retained Passing
1 24,56 0,00 0,00 0,00 100,000
3/4 19,10 0,00 0,00 0,00 100,000
3/8 9,500 0,00 0,00 0,00 100,000
4 4,750 0,00 0,00 0,00 100,000
8 2,360 0,00 0,00 0,00 100,000
10 2,000 0,00 0,00 0,00 100,000
40 0,425 0,16 0,06 0,06 99,936
100 0,150 89,68 35,87 35,94 64,064
200 0,075 3,90 1,56 37,50 62,504
Pan
Total weight (gr) 250,00

HYDROMETER ANALYSIS
(ASTM D421-58 & D422-63; SNI 3423:2008)
Wt. Dry (gr) 50
Specific Gravity (Gs) 2,48
Meniscus Correction, Fm 1
Zero Reading Correction, Fz 4
Temperature Correction, Ft 1,900
Specifik Gravity Correction (a) 1,042
Temperature (T) 27
A 0,01357

Time Hydrometer True Fully Corrected Effective Particle


% refined Combined
(menit) Reading Reading Reading Depth L Diameter % passing
grain (mm)
R'h Rcp Rcl (cm) (mm)
0,25 47,0 44,9 48 8,50 0,0791 93,599 58,503 0,0495
0,5 45,0 42,9 46 8,85 0,0571 89,430 55,897 0,0357
1 43,0 40,9 44 9,00 0,0407 85,260 53,291 0,0254
2 42,0 39,9 43 9,30 0,0293 83,176 51,988 0,0183
5 38,0 35,9 39 10,00 0,0192 74,837 46,776 0,0120
15 35,0 32,9 36 10,45 0,0113 68,584 42,867 0,0071
30 31,0 28,9 32 11,15 0,0083 60,245 37,656 0,0052
60 24,0 21,9 25 12,30 0,0061 45,653 28,535 0,0038
240 18,0 15,9 19 13,25 0,0032 33,145 20,717 0,0020
1440 16,0 13,9 17 13,65 0,0013 28,976 18,111 0,0008
2880 14,0 11,9 15 13,90 0,0009 24,807 15,505 0,0006

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS
(GRADATION CURVES)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel B


Depth :-
Type : Disturbed Sampel

Gravel Sand Silt Clay D60 D30 D10 Cu Cc


0 40,7 38,4 20,9 - - - - -
0
Clay Silt Sand Gravel
Fine Medium Coarse
100

90

80

70

Percentage Passing (%)


60

50

40

30

20

10

0
0,000 0,001 0,010 0,100 1,000 10,000 100,000
Diameter (mm)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


LABORATORY TEST RESULT

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

NO. KIND OF TEST Sampel C

A. PHYSICAL PROPERTIES

1 Natural Water Content ω (%) 12,80


3
2 Unit Weight g (gr/cm ) 1,46
3 Specific Gravity Gs 2,55
4 Liquid Limit LL (%)
Plastic Limit PL (%) Non Plastic
Plasticity Index PI
5 Gradation by Sieve Analysis (% Passing) :
# 10 2,000 mm 100,00
# 40 0,425 mm 99,86
# 200 0,075 mm 17,98
6 Soil Proportion by Gradation Curves (%)
Gravel 0,00
Sand 88,50
Silt 7,50
Clay 4,00
B. SOIL CLASSIFICATION
1 USCS SM

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


WATER CONTENT, UNIT WEIGHT,
SPECIFIC GRAVITY TEST
Project : Uji Laboratorium Material PT Riung Mitra Lestari
Location : Site MGM, Kalimantan Tengah

Sample No. : Sampel C Date : 7-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

WATER CONTENT UNIT WEIGHT


(ASTM D2216-71; SNI 1965:2008) (ASTM D2937-71; SNI 03-3637-1994)

Container No. 1 2 Container No. 1 2


Cont. Weight + Wet Soil (gr) 73,37 72,14 W Ring + Wet soil (gr) 165,97 161,91
Cont. Weight + Dry Soil (gr) 66,27 65,23 W Ring (gr) 81,26 81,26
Water Weight (gr) 7,10 6,91 W wet soil (gr) 84,71 80,65
Container Weight (gr) 10,25 11,80 Diameter Ring (gr) 6,00 6,00
Weight Dry (gr) 56,02 53,43 H Ring (gr) 2,00 2,00
WATER CONTENT (%) 12,67 12,93 Volume (cm³) 56,52 56,52
Average (%) 12,80 Unit Weight (gr/cm³) 1,50 1,43
Average (gr/cm³) 1,46

SPECIFIC GRAVITY TEST


(ASTM D854-58; SNI 1964:2008)

Picnometer No. 1 2
W Picno, Wp (gr) 160,52 171,05
W Picno + Soil, W1 (gr) 263,07 274,53
W Picno + Soil + Water, W2 (gr) 720,20 731,00
W Picno + Water, W3 (gr) 657,79 668,08
Mix Of Temperatur Water + Soil (°C) 27,00 27,00
W4 (W1 - Wp) (gr) 102,55 103,48
Gs (at TºC) 2,55 2,55
Correction, A 0,9983 0,9983
Gs (at 20ºC) = Gs (at TºC) x A 2,55 2,55
Specific Gravity 2,55

Table: Temperatur Correction


T°C Correction T°C Correction T°C Correction
15 1,0009 21 0,9998 27 0,9983
16 1,0007 22 0,9996 28 0,9980
17 1,0006 23 0,9993 29 0,9977
18 1,0004 24 0,9991 30 0,9974
19 1,0002 25 0,9988 31
20 1,0000 26 0,9986 32

Table: Water Intencity (w)


T°C w T°C w T°C w
15 0,999129 21 0,998022 27 0,996544
16 0,998972 22 0,997800 28 0,996264
17 0,998804 23 0,997568 29 0,995976
18 0,998625 24 0,997327 30 0,995678
19 0,998435 25 0,997075 31
20 0,998234 26 0,996814 32

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


ATTERBERG LIMIT TEST
(ASTM D423-66; SNI 1967:2008)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel C Date : 11-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

LIQUID LIMIT PLASTIC LIMIT


Sample No. 1 2 3 4 Sample No. 1 2
Number of Bows Container No.
Container No. W cont + W wet soil (gr)
W cont + W wet soil (gr) W cont + dry soil (gr)
W cont + dry soil (gr) W water (2) - (3) (gr)
Non Plastic Non Plastic
W water (3) - (4) (gr) W Container (gr)
W Container (gr) W dry soil (3) - (5) (gr)
W dry soil (4) - (6) (gr) Water content (4)/(6)*100 (%)
Water content (5)/(7)*100 (%) Plastic limit (%)

Liquid Limit Graph Unified Classification


70 60
Water Content (%)

60 50

Plasticity Index (%)


CL CH
50 40

40 30
MH-OH
30 20

20 10
CL-ML
ML- ML-OL
10 0
1 10
25 100 0 10 20 30 40 50 60 70 80 90 100
Blows Liquid Limit (%)

Liquid Limit (LL) % Soil Classification


Plastic Limit (PL) %
- Non Plastic
Plasticity Index (PI) %

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel C Date : 20-Jun-22


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

SIEVE ANALYSIS
(ASTM C130-46; SNI 03-1968-1990)
Sieve W soil % Weight % Cumulative
No. Ø (mm) (gr) Retained Retained Passing
1 24,56 0,00 0,00 0,00 100,000
3/4 19,10 0,00 0,00 0,00 100,000
3/8 9,500 0,00 0,00 0,00 100,000
4 4,750 0,00 0,00 0,00 100,000
8 2,360 0,00 0,00 0,00 100,000
10 2,000 0,00 0,00 0,00 100,000
40 0,425 0,28 0,14 0,14 99,860
100 0,150 158,72 79,36 79,50 20,500
200 0,075 5,04 2,52 82,02 17,980
Pan
Total weight (gr) 200,00

HYDROMETER ANALYSIS
(ASTM D421-58 & D422-63; SNI 3423:2008)
Wt. Dry (gr) 50
Specific Gravity (Gs) 2,55
Meniscus Correction, Fm 1
Zero Reading Correction, Fz 4
Temperature Correction, Ft 1,900
Specifik Gravity Correction (a) 1,025
Temperature (T) 27
A 0,01328

Time Hydrometer True Fully Corrected Effective Particle


% refined Combined
(menit) Reading Reading Reading Depth L Diameter % passing
grain (mm)
R'h Rcp Rcl (cm) (mm)
0,25 25,0 22,9 26 12,10 0,0924 46,930 8,438 0,0166
0,5 21,0 18,9 22 12,80 0,0672 38,733 6,964 0,0121
1 19,0 16,9 20 13,10 0,0481 34,634 6,227 0,0086
2 15,0 12,9 16 13,75 0,0348 26,437 4,753 0,0063
5 14,0 11,9 15 13,90 0,0221 24,387 4,385 0,0040
15 13,0 10,9 14 14,10 0,0129 22,338 4,016 0,0023
30 12,0 9,9 13 14,25 0,0092 20,289 3,648 0,0016
60 10,0 7,9 11 14,60 0,0066 16,190 2,911 0,0012
240 8,0 5,9 9 14,90 0,0033 12,091 2,174 0,0006
1440 6,0 3,9 7 15,25 0,0014 7,993 1,437 0,0002
2880 4,0 1,9 5 15,55 0,0010 3,894 0,700 0,0002

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS
(GRADATION CURVES)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel C


Depth :-
Type : Disturbed Sampel

Gravel Sand Silt Clay D60 D30 D10 Cu Cc


0 88,5 7,5 4 - - - - -
0
Clay Silt Sand Gravel
Fine Medium Coarse
100

90

80

70

Percentage Passing (%)


60

50

40

30

20

10

0
0,000 0,001 0,010 0,100 1,000 10,000 100,000
Diameter (mm)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


LABORATORY TEST RESULT

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

NO. KIND OF TEST Sampel D

A. PHYSICAL PROPERTIES

1 Natural Water Content ω (%) 18,48


3
2 Unit Weight g (gr/cm ) 1,66
3 Specific Gravity Gs 2,54
4 Liquid Limit LL (%) 29,31
Plastic Limit PL (%) 25,56
Plasticity Index PI 3,75
5 Gradation by Sieve Analysis (% Passing) :
# 10 2,000 mm 100,00
# 40 0,425 mm 99,87
# 200 0,075 mm 65,22
6 Soil Proportion by Gradation Curves (%)
Gravel 0,00
Sand 39,40
Silt 33,80
Clay 26,80
B. SOIL CLASSIFICATION
1 USCS ML

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


WATER CONTENT, UNIT WEIGHT,
SPECIFIC GRAVITY TEST
Project : Uji Laboratorium Material PT Riung Mitra Lestari
Location : Site MGM, Kalimantan Tengah

Sample No. : Sampel D Date : 7-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

WATER CONTENT UNIT WEIGHT


(ASTM D2216-71; SNI 1965:2008) (ASTM D2937-71; SNI 03-3637-1994)

Container No. 1 2 Container No. 1 2


Cont. Weight + Wet Soil (gr) 71,99 75,26 W Ring + Wet soil (gr) 171,81 178,14
Cont. Weight + Dry Soil (gr) 62,38 65,54 W Ring (gr) 81,26 81,26
Water Weight (gr) 9,61 9,72 W wet soil (gr) 90,55 96,88
Container Weight (gr) 11,59 11,64 Diameter Ring (gr) 6,00 6,00
Weight Dry (gr) 50,79 53,90 H Ring (gr) 2,00 2,00
WATER CONTENT (%) 18,92 18,03 Volume (cm³) 56,52 56,52
Average (%) 18,48 Unit Weight (gr/cm³) 1,60 1,71
Average (gr/cm³) 1,66

SPECIFIC GRAVITY TEST


(ASTM D854-58; SNI 1964:2008)

Picnometer No. 1 2
W Picno, Wp (gr) 169,66 161,23
W Picno + Soil, W1 (gr) 271,79 263,30
W Picno + Soil + Water, W2 (gr) 728,95 720,29
W Picno + Water, W3 (gr) 666,88 658,49
Mix Of Temperatur Water + Soil (°C) 27,00 27,00
W4 (W1 - Wp) (gr) 102,13 102,07
Gs (at TºC) 2,55 2,53
Correction, A 0,9983 0,9983
Gs (at 20ºC) = Gs (at TºC) x A 2,55 2,53
Specific Gravity 2,54

Table: Temperatur Correction


T°C Correction T°C Correction T°C Correction
15 1,0009 21 0,9998 27 0,9983
16 1,0007 22 0,9996 28 0,9980
17 1,0006 23 0,9993 29 0,9977
18 1,0004 24 0,9991 30 0,9974
19 1,0002 25 0,9988 31
20 1,0000 26 0,9986 32

Table: Water Intencity (w)


T°C w T°C w T°C w
15 0,999129 21 0,998022 27 0,996544
16 0,998972 22 0,997800 28 0,996264
17 0,998804 23 0,997568 29 0,995976
18 0,998625 24 0,997327 30 0,995678
19 0,998435 25 0,997075 31
20 0,998234 26 0,996814 32

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


ATTERBERG LIMIT TEST
(ASTM D423-66; SNI 1967:2008)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel D Date : 11-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

LIQUID LIMIT PLASTIC LIMIT


Sample No. 1 2 3 4 Sample No. 1 2
Number of Bows 18 23 35 45 Container No. C.1 C.2
Container No. C1 C2 C3 C4 W cont + W wet soil (gr) 32,18 30,27
W cont + W wet soil (gr) 54,89 52,12 58,14 57,08 W cont + dry soil (gr) 27,40 26,54
W cont + dry soil (gr) 44,85 42,57 47,90 46,86 W water (2) - (3) (gr) 4,78 3,73
W water (3) - (4) (gr) 10,04 9,55 10,24 10,22 W Container (gr) 8,94 11,75
W Container (gr) 11,56 10,31 11,54 10,35 W dry soil (3) - (5) (gr) 18,46 14,79
W dry soil (4) - (6) (gr) 33,29 32,26 36,36 36,51 Water content (4)/(6)*100 (%) 25,89 25,22
Water content (5)/(7)*100 (%) 30,16 29,60 28,16 27,99 Plastic limit (%) 25,89 25,22

Liquid Limit Graph Unified Classification


60 60
Water Content (%)

50 50

Plasticity Index (%)


CL CH
40 40
29,31
30 30
MH-OH
20 20

10 10
CL-ML
ML- ML-OL
0 0
1 10
25 100 0 10 20 30 40 50 60 70 80 90 100
Blows Liquid Limit (%)

Liquid Limit (LL) % 29,31 Soil Classification


Plastic Limit (PL) % 25,56
ML Sandy silts of low plasticity
Plasticity Index (PI) % 3,75

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel D Date : 8-Jan-23


Depth :- Tested by : Yudiyansyah, ST
Type : Disturbed Sampel

SIEVE ANALYSIS
(ASTM C130-46; SNI 03-1968-1990)
Sieve W soil % Weight % Cumulative
No. Ø (mm) (gr) Retained Retained Passing
1 24,56 0,00 0,00 0,00 100,000
3/4 19,10 0,00 0,00 0,00 100,000
3/8 9,500 0,00 0,00 0,00 100,000
4 4,750 0,00 0,00 0,00 100,000
8 2,360 0,00 0,00 0,00 100,000
10 2,000 0,00 0,00 0,00 100,000
40 0,425 0,26 0,13 0,13 99,870
100 0,150 66,21 33,11 33,24 66,765
200 0,075 3,09 1,55 34,78 65,220
Pan
Total weight (gr) 200,00

HYDROMETER ANALYSIS
(ASTM D421-58 & D422-63; SNI 3423:2008)
Wt. Dry (gr) 50
Specific Gravity (Gs) 2,54
Meniscus Correction, Fm 1
Zero Reading Correction, Fz 4
Temperature Correction, Ft 1,900
Specifik Gravity Correction (a) 1,028
Temperature (T) 27
A 0,01333

Time Hydrometer True Fully Corrected Effective Particle


% refined Combined
(menit) Reading Reading Reading Depth L Diameter % passing
grain (mm)
R'h Rcp Rcl (cm) (mm)
0,25 46,0 43,9 47 8,70 0,0786 90,219 58,841 0,0513
0,5 43,0 40,9 44 9,00 0,0566 84,054 54,820 0,0369
1 40,0 37,9 41 9,65 0,0414 77,889 50,799 0,0270
2 38,0 35,9 39 10,00 0,0298 73,779 48,118 0,0194
5 37,0 34,9 38 10,15 0,0190 71,723 46,778 0,0124
15 34,0 31,9 35 10,60 0,0112 65,558 42,757 0,0073
30 30,0 27,9 31 11,30 0,0082 57,338 37,396 0,0053
60 27,0 24,9 28 11,80 0,0059 51,172 33,375 0,0039
240 22,0 19,9 23 12,60 0,0031 40,897 26,673 0,0020
1440 16,0 13,9 17 13,65 0,0013 28,566 18,631 0,0008
2880 14,0 11,9 15 13,90 0,0009 24,456 15,950 0,0006

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


PARTICLE SIZE DISTRIBUTION ANALYSIS
(GRADATION CURVES)

Project : Uji Laboratorium Material PT Riung Mitra Lestari


Location : Site MGM, Kalimantan Tengah

Sampel No. : Sampel D


Depth :-
Type : Disturbed Sampel

Gravel Sand Silt Clay D60 D30 D10 Cu Cc


0 39,4 33,8 26,8 - - - - -
0
Clay Silt Sand Gravel
Fine Medium Coarse
100

90

80

70

Percentage Passing (%)


60

50

40

30

20

10

0
0,000 0,001 0,010 0,100 1,000 10,000 100,000
Diameter (mm)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

DOKUMENTASI LABORATORIUM

Pemeriksaan sampel A Pelaksanaan pemeriksaan kadar air (water content)

Pelaksanaan pemeriksaan berat volume (unit weight) Pelaksanaan pemeriksaan berat jenis (specific gravity)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pelaksanaan pemeriksaan analisa saringan (sieve analysis) Pelaksanaan pemeriksaan hidrometer

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pemeriksaan sampel B Pelaksanaan pemeriksaan kadar air (water content)

Pelaksanaan pemeriksaan berat volume (unit weight) Pelaksanaan pemeriksaan berat jenis (specific gravity)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pelaksanaan pemeriksaan analisa saringan (sieve analysis) Pelaksanaan pemeriksaan hidrometer

Pelaksanaan pemeriksaan batas cair (liquid limit) Pelaksanaan pemeriksaan batas plastis (plastic limit)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pemeriksaan sampel C Pelaksanaan pemeriksaan kadar air (water content)

Pelaksanaan pemeriksaan berat volume (unit weight) Pelaksanaan pemeriksaan berat jenis (specific gravity)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pelaksanaan pemeriksaan analisa saringan (sieve analysis) Pelaksanaan pemeriksaan hidrometer

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pemeriksaan sampel D Pelaksanaan pemeriksaan kadar air (water content)

Pelaksanaan pemeriksaan berat volume (unit weight) Pelaksanaan pemeriksaan berat jenis (specific gravity)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions


Uji Laboratorium Material PT Riung Mitra Lestari
Site MGM, Kalimantan Tengah

Pelaksanaan pemeriksaan analisa saringan (sieve analysis) Pelaksanaan pemeriksaan hidrometer

Pelaksanaan pemeriksaan batas cair (liquid limit) Pelaksanaan pemeriksaan batas plastis (plastic limit)

PT Tiyasa Total Rekayasa | Geotechnical Research and Civil Solutions

You might also like