You are on page 1of 33

Summary of Testing of Embankment Material at REL 13

Sampling from : Relocation Road - IP.40 Date of Testing : 05 ~10 Nov 2007
Sample ID : Embankment Material of REL (Relocation Road) 13 Nominal Size : 37.5 - 0 mm

Date Item Result Remarks

07 November 2007 Particle-Size analysis of Soils Percent of Passing


Sieve
size (mm) No
75.00 3 (in) 100.0
50.00 2 (in) 100.0
37.50 1 1/2 (in) 100.0
25.00 1 (in) 99.1
19.00 3/4 (in) 97.7
9.50 3/8 (in) 92.1
4.75 No. 4 86.9
2.00 No. 10 76.5
0.850 No. 20 67.8
0.425 No. 40 53.4
0.250 No. 60 45.2
0.106 No. 140 28.0
0.075 N0. 200 27.0
Liquid Limit (%) : 46.0
Liquid Limit, Plastic Limit, and
09 November 2007 Plastic Limit (%) : 30.9
Plasticity Index of Soils
Plasticity Index (%) : 15.1

Laboratory Compaction Max. Dry Density (gr/cm3) : 1.517


07 November 2007 Characteristic of Soil Using
standard Effort Opt. Moisture content (%) : 21.2
Spesific Gravity of Soil Test
08 November 2007 2.51
Record

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Acssociated Work Nippon Koei & Associates Hazama Brantas Joint Operation
HAZAMA - BRANTAS JOINT OPERATION
PALEMBANG AIRPORT DEVELOPMENT PROJECT (I)
Jakarta Office : C/O. Hazama Corporation Jakarta Representative Office, Surya Building 14th Floor, Suite 1402
Jl. M.h. THAMRIN Kav. 9, Jakarta Pusat 10350 Tel. 021(3983)8844, Fax. 021(3983)8840
Project Office : Jl. Adi Sucipto No. 1, Palembang, Sumatra Selatan Tel. 0711(41)1955, Fax. 071(41)2074

LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS ASTM D 4318

Sampling from :
Relocation Road - IP.40
Sample ID : Date of Testing:
Embankment Material of REL (Relocation Road) 13 09 November 2007
Liquid limit using the Casagrande apparatus.
Test No. 1 2 3 4 5
Mass of Soil+Container a) g 23.96 22.09 25.04 23.72
Mass of Dry Soil+Container b) g 20.99 19.17 21.09 20.13
Mass of Water c)= a-b g 2.97 2.92 3.95 3.59
Mass of Tray d) g 14.32 12.59 12.55 12.77
Mass of Dry Soil e)= b-d g 6.67 6.58 8.54 7.36
Water Content f) = c / e *100 w % 44.53 44.38 46.25 48.78
No. of blows, N times 43 33 23 12
Plastic Limit Determination
Test No. 1 2
Mass of Soil+Container g) g 18.25 16.51
Mass of Dry Soil+Container h) g 17.76 16.08
Mass of Water i)= g-h g 0.49 0.43
Mass of Container j) g 16.16 14.70
Mass of Dry Soil k)= h-j g 1.60 1.38
Water Content l)= i /k *100 w % 30.62 31.16
Average of Water content m) w % 30.89
Water Content (%)

60.0 Liquid Limit (LL) 46.0


%
55.0
Plastic Limit (PL) 30.9
50.0 %
Plasticity Index (PI) 15.1
45.0 %

40.0

35.0

30.0
1 10 100
25
Number of Blows (times)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 016-1
44.5 43
44.4 33
46.3 23
48.8 12

y = -5.3714Ln(x) + 73.199

Calcuration
Y= A* Ln(X)+B
Input A and B by left fomula
A= -3.8321
B= 58.373
X= 25
LL= 46.0379

Tested by the Contractor


Hazama Brantas Joint Operation
PARTICLE-SIZE ANALYSIS OF SOILS ASTM D 422

Sampling from : Relocation Road - IP.40 Date of Testing : 07 November 2007


Sample ID : Embankment Material of REL (Relocation Road) 13
Mass of Sample : 2,614.8 g Maximum Size Particles 37.5 mm

Sieve Material Retained Cumulative Retained Cumulative


Remark
Size (mm) No. (g) (g) % Retained % Passed
75.00 3 (in) 0.0 0.0 0.0 100.0
50.00 2 (in) 0.0 0.0 0.0 100.0
37.50 1 1/2 (in) 0.0 0.0 0.0 100.0
25.00 1 (in) 24.3 24.3 0.9 99.1
19.00 3/4 (in) 35.8 60.1 2.3 97.7
9.50 3/8 (in) 145.3 205.4 7.9 92.1
4.75 No. 4 137.3 342.7 13.1 86.9
2.00 No. 10 270.5 613.2 23.5 76.5
0.850 No. 20 228.4 841.6 32.2 67.8
0.425 No. 40 376.8 1218.4 46.6 53.4
0.250 No. 60 213.3 1431.7 54.8 45.2
0.106 No. 140 451.8 1883.5 72.0 28.0
0.075 N0. 200 26.3 1909.8 73.0 27.0
C u m u la t iv e P a s s e d ( % )

100

90

80

70

60

50

40

30

20

10

0
0.01 0.10 1.00 10.00 100.00 1000.00
MEMO Sieve Size (mm)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 020-1
SPESIFIC GRAVITY OF SOIL TEST RECORD ASTM D 854

Structure / Location : Relocation Road - IP.40 Date : 08 November 2007

Room Temperature : 29 0 C

Specific Gravity of Soil Test Record

No. Pycnometer 2 3

Weight of Pycnometer a (gr) 38.5 37.3

Weight of Pycnometer + water (Calibration) 220C b (gr) 138.5 137.25

Weight of Pycnometer + dry sample c (gr) 64.44 63.47

Weight of Pycnometer + sample + water d (gr) 154.10 153

Temperature (oC) 25 25

A Weight of dry sample, = c - a (gr) 25.94 26.17

B Density of Water at the test Temperature (Tt), = b - (d - A) (gr) 10.34 10.42

Gt Spesific Grafity at Soil Solids the test temperature, = A / B 2.51 2.51

Average 2.51

G = Gt x K, (Specific Gravity) 2.51

K = Temperature Coefficient (ASTM D 854 Table 2)

MEMO

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,
ASTM D 698
STANDARD EFFORT
Sampling from : Relocation Road -IP.40. Date of Testing : 07 November 2007

Sample ID : Embankment Material of REL (Relocation Road )13

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 15.24

Application of Sample Not reuse Drop Height mm 305 Hight cm 11.65


Mold
Blows /Layer 56 Vol cm3 2125.13

Layer 3 Weight g 6283

Density

Test No. 1 2 3 4 5 6

Mass of moist Soil+mold a) g 9630 9825 10050 10180 10235 10185

Mass of mold b) g 6283 6283 6283 6283 6283 6283

Mass of Moist Soil c)=a-b g 3347 3542 3767 3897 3952 3902

Moist Density d)=c/vol g/cm3 1.575 1.667 1.773 1.834 1.860 1.836

Dry Density e) ((d/(w+100))*100 g/cm3 1.369 1.418 1.491 1.515 1.505 1.456

Water content

Mass of Container f) g 326.3 331.3 124.4 124.2 131.8 142.6

Mass of Moist of Soil+Container g) g 1029.9 1008.8 951.2 918.2 1040.9 905.8

Mass of Dry Soil+Container h) g 938 907.9 819.8 780.0 867.5 747.6

Mass of Water i)=g-h g 91.9 100.9 131.4 138.2 173.4 158.2


D ry D ens ity ρ d (g/c m 3)

Mass of Dry Soil j)=h-f g 611.7 576.6 695.4 655.8 735.7 605.0

Water Content w=i/j*100 w % 15.0 17.5 18.9 21.1 23.6 26.1

1.650

1.600

Maximum Dry Density


1.550 1.517
gr/cm3
1.500 Optimum Moisture
21.2
Content %
1.450
Specific Gravity
1.400
2.51

1.350

1.300
1.67
13

18

23

28

21.8
Water Content w (%)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Irrigation Sub-Project Nippon Koei & Associates Hazama Brantas Joint Operation
QC 017-1

y = -0.0002146790x3 + 0.0094174210x2 - 0.1044384368x + 1.6972251976

y = -0.00021468 x3 + 0.009417 x2 - 0.10444 x + 1.697


y' = -0.000644 x 2
+ 0.0188348 x - 0.10444

dengan rumus abc : x1 = -b + √(b2-4ac)


x1 = =-b + √(b2-4ac) 2a
2a
= 0+ 0.009257559 0
-0.001288074

= 7.43535135415

x2 = 0- √(b2-4ac) x2 = -b - √(b2-4ac)
2a 2a
= 0- 0.009257559
-0.001288074

= 21.81

y = 1.672
Mole
Big Small

Dia 15.24 10.16

Height 11.65 11.64

Vol 2125 944

Weight 6283

2.51

1.638 21.2

1.576 23.6

1.517 26.1

1.7 22.45989

1.6 26.1364

1.5 30.30303

1.4 35.06494

Caluculation 1.3 40.55944


1.2 46.9697

Y=AX2+BX+C
Imput below colored table
A= -0.00100509
B= 0.06705441
C= 0.14693596
Y'=2AX+B
Y=0, X=-B/2A
X= 33.3574157538
Y= 1.26531687625

or
Operation
1.5 1.334 1.1956 1.1281
25.43 33.6 43.58 49.22

1.334

√(b2-4ac)

√(b2-4ac)
Summary of Testing of Embankment Material at REL 14

Sampling from : Relocation Road - IP.41 Date of Testing : 05 ~ 10 Nov. 2007


Sample ID : Embankment Material of REL (Relocation Road) 14 Nominal Size : 25.0 - 0 mm

Date Item Result Remarks

07 November 2007 Particle-Size analysis of Soils Percent of Passing


Sieve
size (mm) No
75.00 3 (in) 100.0
50.00 2 (in) 100.0
37.50 1 1/2 (in) 100.0
25.00 1 (in) 100.0
19.00 3/4 (in) 99.2
9.50 3/8 (in) 96.7
4.75 No. 4 93.2
2.00 No. 10 86.7
0.850 No. 20 80.1
0.425 No. 40 64.1
0.250 No. 60 54.4
0.106 No. 140 33.7
0.075 N0. 200 30.8
Liquid Limit (%) : 37.5
Liquid Limit, Plastic Limit, and
09 November 2007 Plastic Limit (%) : 19.5
Plasticity Index of Soils
Plasticity Index (%) : 18.0

Laboratory Compaction Max. Dry Density (gr/cm3) : 1.488


07 November 2007 Characteristic of Soil Using
standard Effort Opt. Moisture content (%) : 24.3
Spesific Gravity of Soil Test
08 November 2007 2.56
Record

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Acssociated Work Nippon Koei & Associates Hazama Brantas Joint Operation
HAZAMA - BRANTAS JOINT OPERATION
PALEMBANG AIRPORT DEVELOPMENT PROJECT (I)
Jakarta Office : C/O. Hazama Corporation Jakarta Representative Office, Surya Building 14th Floor, Suite 1402
Jl. M.h. THAMRIN Kav. 9, Jakarta Pusat 10350 Tel. 021(3983)8844, Fax. 021(3983)8840
Project Office : Jl. Adi Sucipto No. 1, Palembang, Sumatra Selatan Tel. 0711(41)1955, Fax. 071(41)2074

LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS ASTM D 4318

Sampling from :
Relocation Road - IP.41
Sample ID : Date of Testing:
Embankment Material of REL (Relocation Road) 14 09 November 2007
Liquid limit using the Casagrande apparatus.
Test No. 1 2 3 4 5
Mass of Soil+Container a) g 26.77 23.26 23.57 26.71
Mass of Dry Soil+Container b) g 23.61 20.48 21.22 23.38
Mass of Water c)= a-b g 3.16 2.78 2.35 3.33
Mass of Tray d) g 14.69 12.82 14.77 14.49
Mass of Dry Soil e)= b-d g 8.92 7.66 6.45 8.89
Water Content f) = c / e *100 w % 35.43 36.29 36.43 37.46
No. of blows, N times 43 27 17 9
Plastic Limit Determination
Test No. 1 2
Mass of Soil+Container g) g 15.88 15.77
Mass of Dry Soil+Container h) g 15.32 15.27
Mass of Water i)= g-h g 0.56 0.50
Mass of Container j) g 12.66 12.48
Mass of Dry Soil k)= h-j g 2.66 2.79
Water Content l)= i /k *100 w % 21.05 17.92
Average of Water content m) w % 19.49
Water Content (%)

Liquid Limit (LL) 37.5


47.0 %
Plastic Limit (PL) 19.5
42.0
%
Plasticity Index (PI) 18.0
37.0
%

32.0

27.0

22.0
1 10 100
25
Number of Blows (times)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 016-1
35.4 43
36.3 27
36.4 17
37.5 9

y = -5.3714Ln(x) + 73.199

Calcuration
Y= A* Ln(X)+B
Input A and B by left fomula
A= -0.0489
B= 37.635
X= 25
LL= 37.4776

Tested by the Contractor


Hazama Brantas Joint Operation
PARTICLE-SIZE ANALYSIS OF SOILS ASTM D 422

Sampling from : Relocation Road - IP.41 Date of Testing : 07 November 2007


Sample ID : Embankment Material of REL (Relocation Road) 14
Mass of Sample : 2,477.6 g Maximum Size Particles 25.0 mm

Sieve Material Retained Cumulative Retained Cumulative


Remark
Size (mm) No. (g) (g) % Retained % Passed
75.00 3 (in) 0.0 0.0 0.0 100.0
50.00 2 (in) 0.0 0.0 0.0 100.0
37.50 1 1/2 (in) 0.0 0.0 0.0 100.0
25.00 1 (in) 0.0 0.0 0.0 100.0
19.00 3/4 (in) 19.7 19.7 0.8 99.2
9.50 3/8 (in) 61.0 80.7 3.3 96.7
4.75 No. 4 87.7 168.4 6.8 93.2
2.00 No. 10 159.9 328.3 13.3 86.7
0.850 No. 20 163.9 492.2 19.9 80.1
0.425 No. 40 398.1 890.3 35.9 64.1
0.250 No. 60 239.7 1130.0 45.6 54.4
0.106 No. 140 512.8 1642.8 66.3 33.7
0.075 N0. 200 71.7 1714.5 69.2 30.8
C u m u la t iv e P a s s e d ( % )

100

90

80

70

60

50

40

30

20

10

0
0.01 0.10 1.00 10.00 100.00 1000.00
MEMO Sieve Size (mm)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 020-1
SPESIFIC GRAVITY OF SOIL TEST RECORD ASTM D 854

Structure / Location : Relocation Road - IP.41 Date : 08 November 2007

Room Temperature : 29 0 C

Specific Gravity of Soil Test Record

No. Pycnometer 5 8

Weight of Pycnometer a (gr) 35.7 35.1

Weight of Pycnometer + water (Calibration) 220C b (gr) 135.6 134.9

Weight of Pycnometer + dry sample c (gr) 61.67 61.64

Weight of Pycnometer + sample + water d (gr) 151.40 151.1

Temperature (oC) 25 25

A Weight of dry sample, = c - a (gr) 25.97 26.54

B Density of Water at the test Temperature (Tt), = b - (d - A) (gr) 10.12 10.34

Gt Spesific Grafity at Soil Solids the test temperature, = A / B 2.57 2.57

Average 2.57

G = Gt x K, (Specific Gravity) 2.56

K = Temperature Coefficient (ASTM D 854 Table 2)

MEMO

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,
ASTM D 698
STANDARD EFFORT
Sampling from : Relocation Road -IP.41 Date of Testing : 07 November 2007

Sample ID : Embankment Material of REL (Relocation Road )14

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 15.24

Application of Sample Not reuse Drop Height mm 305 Hight cm 11.65


Mold
Blows /Layer 56 Vol cm3 2125.13

Layer 3 Weight g 6283

Density

Test No. 1 2 3 4 5 6

Mass of moist Soil+mold a) g 9765 9970 10125 10220 10195 10115

Mass of mold b) g 6283 6283 6283 6283 6283 6283

Mass of Moist Soil c)=a-b g 3482 3687 3842 3937 3912 3832

Moist Density d)=c/vol g/cm3 1.638 1.735 1.808 1.853 1.841 1.803

Dry Density e) ((d/(w+100))*100 g/cm3 1.398 1.435 1.476 1.478 1.448 1.409

Water content

Mass of Container f) g 328.4 330.8 329.6 331.3 327.7 328.9

Mass of Moist of Soil+Container g) g 917.5 1037.6 1120.0 1118.2 1052.5 1056.0

Mass of Dry Soil+Container h) g 831.1 915.6 974.9 959.3 898.0 897.1

Mass of Water i)=g-h g 86.4 122.0 145.1 158.9 154.5 158.9


D ry D ens ity ρ d (g/c m 3)

Mass of Dry Soil j)=h-f g 502.7 584.8 645.3 628.0 570.3 568.2

Water Content w=i/j*100 w % 17.2 20.9 22.5 25.3 27.1 28.0

Syaifuddin:
kolom jangan
menampilkan
persamaan
1.600
matematika-nya

1.550
Maximum Dry Density
1.488
gr/cm3
1.500
Optimum Moisture
24.3
Content %
1.450
Specific Gravity
2.56
1.400

1.350
1.67
15

20

25

30

21.8
Water Content w (%)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
QC 017-1

y = -0.0002146790x3 + 0.0094174210x2 - 0.1044384368x + 1.6972251976

y = -0.00021468 x3 + 0.009417 x2 - 0.10444 x + 1.697


y' = -0.000644 x 2
+ 0.0188348 x - 0.10444

dengan rumus abc : x1 = -b + √(b2-4ac)


x1 = =-b + √(b2-4ac) 2a
2a
= 0+ 0.009257559 0
-0.001288074

= 7.43535135415

x2 = 0- √(b2-4ac) x2 = -b - √(b2-4ac)
2a 2a
= 0- 0.009257559
-0.001288074

= 21.81

y = 1.672
Mole
Big Small

Dia 15.24 10.16

Height 11.65 11.64

Vol 2125 944

Weight 6283

2.56

1.554 25.3

1.511 27.1

1.491 28

1.7 22.45989

1.6 26.1364

1.5 30.30303

1.4 35.06494

Caluculation 1.3 40.55944


1.2 46.9697

Y=AX2+BX+C
Imput below colored table
A= -0.00100509
B= 0.06705441
C= 0.14693596
Y'=2AX+B
Y=0, X=-B/2A
X= 33.3574157538
Y= 1.26531687625

ctor
nt Operation
1.5 1.334 1.1956 1.1281
25.43 33.6 43.58 49.22

1.334

√(b2-4ac)

√(b2-4ac)
Summary of Testing of Embankment Material at REL 15

Sampling from : Relocation Road - IP.48 Date of Testing : 05 ~ 10 Nov 2007


Sample ID : Embankment Material of REL (Relocation Road) 15 Nominal Size : 25.0 - 0 mm

Date Item Result Remarks

07 November 2007 Particle-Size analysis of Soils Percent of Passing


Sieve
size (mm) No
75.00 3 (in) 100.0
50.00 2 (in) 100.0
37.50 1 1/2 (in) 100.0
25.00 1 (in) 100.0
19.00 3/4 (in) 98.4
9.50 3/8 (in) 94.8
4.75 No. 4 90.2
2.00 No. 10 80.9
0.850 No. 20 73.2
0.425 No. 40 61.9
0.250 No. 60 57.1
0.106 No. 140 40.0
0.075 N0. 200 35.5
Liquid Limit (%) : 44.9
Liquid Limit, Plastic Limit, and
09 November 2007 Plastic Limit (%) : 22.2
Plasticity Index of Soils
Plasticity Index (%) : 22.7

Laboratory Compaction Max. Dry Density (gr/cm3) : 1.442


07 November 2007 Characteristic of Soil Using
standard Effort Opt. Moisture content (%) : 23.8
Spesific Gravity of Soil Test
08 November 2007 2.59
Record

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Acssociated Work Nippon Koei & Associates Hazama Brantas Joint Operation
HAZAMA - BRANTAS JOINT OPERATION
PALEMBANG AIRPORT DEVELOPMENT PROJECT (I)
Jakarta Office : C/O. Hazama Corporation Jakarta Representative Office, Surya Building 14th Floor, Suite 1402
Jl. M.h. THAMRIN Kav. 9, Jakarta Pusat 10350 Tel. 021(3983)8844, Fax. 021(3983)8840
Project Office : Jl. Adi Sucipto No. 1, Palembang, Sumatra Selatan Tel. 0711(41)1955, Fax. 071(41)2074

LIQUID LIMIT, PLASTIC LIMIT, AND PLASTICITY INDEX OF SOILS ASTM D 4318

Sampling from :
Relocation Road - IP.48
Sample ID : Date of Testing:
Embankment Material of REL (Relocation Road) 15 09 November 2007
Liquid limit using the Casagrande apparatus.
Test No. 1 2 3 4 5
Mass of Soil+Container a) g 24.33 24.03 27.26 28.46
Mass of Dry Soil+Container b) g 20.89 21.14 23.22 23.96
Mass of Water c)= a-b g 3.44 2.89 4.04 4.50
Mass of Tray d) g 12.72 14.66 14.75 14.72
Mass of Dry Soil e)= b-d g 8.17 6.48 8.47 9.24
Water Content f) = c / e *100 w % 42.11 44.60 47.70 48.70
No. of blows, N times 36 28 18 12
Plastic Limit Determination
Test No. 1 2
Mass of Soil+Container g) g 14.54 14.10
Mass of Dry Soil+Container h) g 14.13 13.80
Mass of Water i)= g-h g 0.41 0.30
Mass of Container j) g 12.41 12.34
Mass of Dry Soil k)= h-j g 1.72 1.46
Water Content l)= i /k *100 w % 23.84 20.55
Average of Water content m) w % 22.19
Water Content (%)

60.0 Liquid Limit (LL) 44.9


%
55.0
Plastic Limit (PL) 22.2
50.0 %
Plasticity Index (PI) 22.7
45.0 %

40.0

35.0

30.0
1 10 100
25
Number of Blows (times)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 016-1
42.1 36
44.6 28
47.7 18
48.7 12

y = -5.3714Ln(x) + 73.199

Calcuration
Y= A* Ln(X)+B
Input A and B by left fomula
A= -6.0117
B= 64.248
X= 25
LL= 44.8971

Tested by the Contractor


Hazama Brantas Joint Operation
PARTICLE-SIZE ANALYSIS OF SOILS ASTM D 422

Sampling from : Relocation Road - IP.48 Date of Testing : 07 November 2007


Sample ID : Embankment Material of REL (Relocation Road) 15
Mass of Sample : 2,558.7 g Maximum Size Particles 25.0 mm

Sieve Material Retained Cumulative Retained Cumulative


Remark
Size (mm) No. (g) (g) % Retained % Passed
75.00 3 (in) 0.0 0.0 0.0 100.0
50.00 2 (in) 0.0 0.0 0.0 100.0
37.50 1 1/2 (in) 0.0 0.0 0.0 100.0
25.00 1 (in) 0.0 0.0 0.0 100.0
19.00 3/4 (in) 41.3 41.3 1.6 98.4
9.50 3/8 (in) 91.8 133.1 5.2 94.8
4.75 No. 4 117.3 250.4 9.8 90.2
2.00 No. 10 238.4 488.8 19.1 80.9
0.850 No. 20 195.7 684.5 26.8 73.2
0.425 No. 40 290.5 975.0 38.1 61.9
0.250 No. 60 123.5 1098.5 42.9 57.1
0.106 No. 140 437.6 1536.1 60.0 40.0
0.075 N0. 200 114.2 1650.3 64.5 35.5
C u m u la t iv e P a s s e d ( % )

100

90

80

70

60

50

40

30

20

10

0
0.01 0.10 1.00 10.00 100.00 1000.00
MEMO Sieve Size (mm)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 020-1
SPESIFIC GRAVITY OF SOIL TEST RECORD ASTM D 854

Structure / Location : Relocation Road - IP.48 Date : 08 November 2007

Room Temperature : 29 0 C

Specific Gravity of Soil Test Record

No. Pycnometer 4 12

Weight of Pycnometer a (gr) 38.0 35.7

Weight of Pycnometer + water (Calibration) 220C b (gr) 138.1 135.85

Weight of Pycnometer + dry sample c (gr) 63.25 61.01

Weight of Pycnometer + sample + water d (gr) 153.60 151.4

Temperature (oC) 25 25

A Weight of dry sample, = c - a (gr) 25.25 25.31

B Density of Water at the test Temperature (Tt), = b - (d - A) (gr) 9.75 9.76

Gt Spesific Grafity at Soil Solids the test temperature, = A / B 2.59 2.59

Average 2.59

G = Gt x K, (Specific Gravity) 2.59

K = Temperature Coefficient (ASTM D 854 Table 2)

MEMO

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,
ASTM D 698
STANDARD EFFORT
Sampling from : Relocation Road -IP.48 Date of Testing : 07 November 2007

Sample ID : Embankment Material of REL (Relocation Road )15

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 15.24

Application of Sample Not reuse Drop Height mm 305 Hight cm 11.65


Mold
Blows /Layer 56 Vol cm3 2125.13

Layer 3 Weight g 6283

Density

Test No. 1 2 3 4 5 6

Mass of moist Soil+mold a) g 5253 5395 5507 5497 10120 10080

Mass of mold b) g 3990 6283 6283 6283 6283 6283

Mass of Moist Soil c)=a-b g 1263 -888 -776 -786 3837 3797

Moist Density d)=c/vol g/cm3 1.347 -0.418 -0.365 -0.370 1.806 1.787

Dry Density e) ((d/(w+100))*100 g/cm3 1.128 -0.350 -0.295 -0.292 1.406 1.362

Water content

Mass of Container f) g 15.1 402.7 329.5 326.9 142.0 150.8

Mass of Moist of Soil+Container g) g 47.1 1134.3 1028.0 959.1 798.1 1068.1

Mass of Dry Soil+Container h) g 41.9 1015.3 894.0 826.3 652.8 849.8

Mass of Water i)=g-h g 5.2 119.0 134.0 132.8 145.3 218.3


D ry D ens ity ρ d (g/c m 3)

Mass of Dry Soil j)=h-f g 26.8 612.6 564.5 499.4 510.8 699.0

Water Content w=i/j*100 w % 19.4 19.4 23.7 26.6 28.4 31.2


Syaifuddin:
kolom jangan
menampilkan
persamaan
1.550
matematika-nya

1.500

Maximum Dry Density


1.442
1.450 gr/cm3
Optimum Moisture
23.8
1.400 Content %
Specific Gravity
2.59
1.350

1.300
15

20

25

30

1.67
Water Content w (%) 21.8

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
QC 017-1

y = -0.0002146790x3 + 0.0094174210x2 - 0.1044384368x + 1.6972251976

y = -0.00021468 x3 + 0.009417 x2 - 0.10444 x + 1.697


y' = -0.000644 x 2
+ 0.0188348 x - 0.10444

dengan rumus abc : x1 = -b + √(b2-4ac)


x1 = =-b + √(b2-4ac) 2a
2a
= 0+ 0.009257559 0
-0.001288074

= 7.43535135415

x2 = 0- √(b2-4ac) x2 = -b - √(b2-4ac)
2a 2a
= 0- 0.009257559
-0.001288074

= 21.81

y = 1.672
Mole
Big Small

Dia 15.24 10.16

Height 11.65 11.64

Vol 937.37 944

Weight 3990

2.3

1.427 26.6

1.391 28.4

1.339 31.2

1.7 22.45989

1.6 26.1364

1.5 30.30303

1.4 35.06494

Caluculation 1.3 40.55944


1.2 46.9697

Y=AX2+BX+C
Imput below colored table
A= -0.00100509
B= 0.06705441
C= 0.14693596
Y'=2AX+B
Y=0, X=-B/2A
X= 33.3574157538
Y= 1.26531687625

ctor
nt Operation
1.5 1.334 1.1956 1.1281
25.43 33.6 43.58 49.22

1.334

√(b2-4ac)

√(b2-4ac)
Jl. HERTASNING BLOK II/02 MAKASSAR SULAWESI SELATAN
Phone (62-411) 867176, 867183 Fax. (62-411) 862212 e-mail : ponre_akpp@yahoo.com

LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,


ASTM D 698
STANDARD EFFORT
Sampling from : Tonra Secondary Canal Date Of Testing : 04 October 2007

Sample ID : 0

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 10.10

Application of Sample Not reuse Drop Height mm 32 Hight cm 11.70


Mold
Blows /Layer 25 Vol cm3 937.39

Layer 3 Weight g 3990

Density

Test No. 1 2 3 4 5 6 7 8

Mass of moist Soil+mold a) g 5253 5395 5507 5497

Mass of mold b) g 3990 3990 3990 3990

Mass of Moist Soil c)=a-b g 1263 1405 1517 1507

Moist Density d)=c/vol g/cm3 1.347 1.499 1.618 1.608

Dry Density e) ((d/(w+100))*100 g/cm3 1.128 1.263 1.246 1.236

Water content

Mass of Container f) g 15.1 15.2 15.1 15.3 15.2 15.3 17.3 14.8

Mass of Moist of Soil+Container g) g 47.1 47.9 56.6 49.9 55.2 51.9 78.3 80.0

Mass of Dry Soil+Container h) g 41.9 42.7 47.1 41.9 43.4 41.5 57.3 57.6

Mass of Water i)=g-h g 5.2 5.1 9.6 8.0 11.8 10.4 21.0 22.4

Mass of Dry Soil j)=h-f g 26.8 27.5 32.0 26.6 28.2 26.2 40.0 42.8

Water Content w=i/j*100 w % 19.4 18.6 29.9 30.0 42.0 39.7 52.4 52.4
D ry D ensity ρd (g /cm 3 )

Mean Value w % 19.034 29.960 40.830 52.404


Dry Density γ d 1.132 1.153 1.149 1.055

Syaifuddin :
kolom jangan
menampilkan
2 .0 0 0

persamaan
matematika-nya

Maximum Dry Density


1.19
1 .5 0 0

gr/cm3
Optimum Moisture
32.0
Content %
1 .0 0 0

Specific Gravity
2.3
0 .5 0 0

1.672
0 .0 0 0

10 30 50
21.8
Water Content w (%)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Irrigation System Works Nippon Koei & Associates PT. Adhi Karya - PT. PP JO
Checked by DISIMP Consultant
Ponre Ponre Irrigation System Works Nippon Koei & Associates PT. Adhi Karya - PT. PP JO

QC 017-1
Jl. HERTASNING BLOK II/02 MAKASSAR SULAWESI SELATAN
Phone (62-411) 867176, 867183 Fax. (62-411) 862212 e-mail : ponre_akpp@yahoo.com

LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,


ASTM D 698
STANDARD EFFORT
Sampling from : Relocation Road -IP.48 Date Of Testing : 07 November 2007

Sample ID : Embankment Material of REL (Relocation Road )15

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 15.24

Application of Sample Not reuse Drop Height mm 305 Hight cm 11.65


Mold
Blows /Layer 56 Vol cm3 2125.13

Layer 3 Weight g 6283

Density

Test No. 1 2 3 4 5 6 7 8

Mass of moist Soil+mold a) g 5253 5395 5507 5497

Mass of mold b) g 3990 3990 3990 3990

Mass of Moist Soil c)=a-b g 1263 1405 1517 1507

Moist Density d)=c/vol g/cm3 0.594 0.661 0.714 0.709

Dry Density e) ((d/(w+100))*100 g/cm3 0.498 0.557 0.550 0.545

Water content

Mass of Container f) g 15.1 15.2 15.1 15.3 15.2 15.3 17.3 14.8

Mass of Moist of Soil+Container g) g 47.1 47.9 56.6 49.9 55.2 51.9 78.3 80.0

Mass of Dry Soil+Container h) g 41.9 42.7 47.1 41.9 43.4 41.5 57.3 57.6

Mass of Water i)=g-h g 5.2 5.1 9.6 8.0 11.8 10.4 21.0 22.4

Mass of Dry Soil j)=h-f g 26.8 27.5 32.0 26.6 28.2 26.2 40.0 42.8

Water Content w=i/j*100 w % 19.4 18.6 29.9 30.0 42.0 39.7 52.4 52.4
Dry Density ρd (g/cm3)

Mean Value w % 19.034 29.960 40.830 52.404


Dry Density γ d 0.499 0.509 0.507 0.465
Syaifuddin:
kolom jangan
menampilkan
2.000 persamaan
matematika-nya

Maximum Dry Density


1.190
1.500 gr/cm3
Optimum Moisture
32.0
Content %
1.000
Specific Gravity
2.3

0.500

0.000 1.672
10 30 50 21.8
Water Content w (%)
Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor
Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation
Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor
Ponre Ponre Dam and Associated Work Nippon Koei & Associates Hazama Brantas Joint Operation

QC 017-1
Jl. HERTASNING BLOK II/02 MAKASSAR SULAWESI SELATAN
Phone (62-411) 867176, 867183 Fax. (62-411) 862212 e-mail : ponre_akpp@yahoo.com

LABORATORY COMPACTION CHARACTERISTIC OF SOIL USING,


ASTM D 698
STANDARD EFFORT
Sampling from : Date Of Testing :

Sample ID :

Test Method Soil Type

Preparation of Method Moist preparation Mass of Rammer kg 2.5 Dia. cm 10.10

Application of Sample Not reuse Drop Height mm 32 Hight cm 11.70


Mold
Blows /Layer 25 Vol cm3 937.39

Layer 3 Weight g 3990

Density

Test No. 1 2 3 4 5 6 7 8

Mass of Soil + Container a) g 5253 5395 5507 5497


Mass of Dry Soil + Container b) g 3990 3990 3990 3990
Mass of Water c)=a-b g 1263 1405 1517 1507
Mass of Tray d)=c/vol g/cm3 1.347 1.499 1.618 1.608
Water content e) ((d/(w+100))*100 g/cm3 1.128 1.263 1.246 1.236
Water content f)

Mass of Container f) g 15.1 15.2 15.1 15.3 15.2 15.3 17.3 14.8

Mass of Moist of Soil+Container g) g 47.1 47.9 56.6 49.9 55.2 51.9 78.3 80.0

Mass of Dry Soil+Container h) g 41.9 42.7 47.1 41.9 43.4 41.5 57.3 57.6

Mass of Water i)=g-h g 5.2 5.1 9.6 8.0 11.8 10.4 21.0 22.4

Mass of Dry Soil j)=h-f g 26.8 27.5 32.0 26.6 28.2 26.2 40.0 42.8

Water Content w=i/j*100 w % 19.4 18.6 29.9 30.0 42.0 39.7 52.4 52.4
D ry D ensity ρd (g /cm 3 )

Mean Value w % 19.034 29.960 40.830 52.404


Dry Density γ d 1.132 1.153 1.149 1.055
2 .0 0 0

Syaifuddin :
kolom jangan
menampilkan
Maximum Dry Density
persamaan
1.190
1 .5 0 0

matematika-nya
gr/cm3
Optimum Moisture
32.0
Content %
1 .0 0 0

Specific Gravity
2.3
0 .5 0 0

1.672
0 .0 0 0

10 30 50
21.8
Water Content w (%)

Witnessed by the Engineer Checked by DISIMP Consultant Tested by the Contractor


Ponre Ponre Irrigation System Works Nippon Koei & Associates PT. Adhi Karya - PT. PP JO
Checked by DISIMP Consultant
Ponre Ponre Irrigation System Works Nippon Koei & Associates PT. Adhi Karya - PT. PP JO

QC 017-1