Professional Documents
Culture Documents
capacity conductivity
Thermal properties
*Thermal conductivity of pipe (W/m.K) =
*Thermal conductivity of insulation (W/m.K) =
*Thermal conductivity of air =
*Thermal conductivity of emulsion (W/m.K) =
Temperature data
*Temperature of emulsion when entering the pipeline(°C) =
*Required temperature of emulsion to cool down to (°C) =
*Temperature of ambient air(°C) =
Air properties
=
*Kinematic viscosity of air (Refer to Air Thermophysical properties sheet)
*Specific heat capacity of air (J/kg.K) =
*Density of air (kg/m3) =
*Pr (refer to air convection coefficient data sheet) =
*Velocity of air (m/s) =
Convection coefficient for air (w/m2.K) =
Emulsion properties
*Density of emulsion(kg/m3) =
*Specific heat capacity of emulsion (kJ/kg.K) =
Calculated results
Overall heat transfer coefficient =
Heat loss through the pipeline (W) =
Time taken to cool down to desired temperature (hours) =
ng stagnant emulsion
* Please enter values marked wit
8.625 = 0.10954 m
7.981 = 0.10136 m 0.66508 ft
1 = 0.16034 m 0.26988 m 0.88542
1000
45
0.035
0.0243
0.6785
176 = 449.15 K
30 = 303.15 K
-15 = 258.15 K
0.0000133
1000
4180
0.1430414651682
151992.75191435
118.973489862388
Please enter values marked with *
ft
Convective and conductive(combined) heat loss for a pipe with flowing emulsion
Thermal properties
*Thermal conductivity of pipe (W/m.K)
*Thermal conductivity of insulation (W/m.K)
*Thermal conductivity of air
*Thermal conductivity of emulsion (W/m.K)
Temperature data
*Temperature of emulsion when entering the pipeline(°C)
*Temperature of ambient air(°C)
Air properties
*Kinematic viscosity of air (Refer to Air Thermophysical properties sheet)
*Specific heat capacity of air (J/kg.K)
*Density of air (kg/m3)
*Pr (refer to air convection coefficient data sheet)
*Velocity of air (m/s)
Convection coefficient for air (w/m2.K)
Emulsion properties
*Volumetric flowrate of emulsion (m3/h)
*Density of emulsion (kg/m3)
*Specific heat capacity of emulsion (kJ/kg.K)
*Dynamic viscosity of emulsion (Pa.s)
Mass flowrate of emulsion (kg/h)
Velocity of emulsion (m/s)
Prandtl Number
Reynolds Number for emulsion
Nusselts number
Convection coefficient inside pipe (W/m2.K)
Calculated results
Overall heat transfer coefficient
Heat loss through the pipeline (W)
Exit temperature (°C)
h flowing emulsion
* Please enter values marked
= 8.625 = 0.10954 m
= 7.981 = 0.10136 m 0.66508 ft
= 1 = 0.16034 m 0.26988 m 0.88542
= 1000
= 45
= 0.035
= 0.0243
= 0.64
= 176 = 449.15 K
= -15 = 258.15 K
= 0.0000133
= 1004.46 = 0.23991BTU/lb.F
= 1.388 = 0.08665 lb/ft3
= 0.715
= 5 = 59055 ft/h
= 26.4371301452454
= 500
= 1000
= 4180
= 0.005
= 500000
= 4.30323999154098
= 32.65625
= 174468.324532242
= 1021.62380047444
= 3225.37301831832
= 0.14302457654308
= 151974.806428373
= 175.738225213808
Please enter values marked with *
ft