You are on page 1of 4

AS-Interface Safety at Work

COMPACTplus/AS-i Safety Light Curtains

Electrical connection
Connection example, see page 318.
For more information go to www.leuze.com/compactplus-m and www.leuze.com/compactplus-b.

Dimensional drawings

B
A

!
52

Receiver

22 72
55

prior to installation!
Pay attention to manual
anleitung beachten!
Vor Anschluss Betriebs-
safety remark:
Sicherheitshinweis
Transmitter

failure
selftest
identifier
channel 2
channel 1

A = Protective field height according to ordering information


B = A + 134 mm

Dimensions in mm
Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.

Ordering information
Ordering information, see Safety Light Curtains COMPACTplus, page 108.

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Machine Safety
COMPACTplus/AS-i Safety Light curtains
Important technical data, overview

Machine Safety
Services
Type in accordance with
Type 4
IEC/EN 61496
SIL in accordance with IEC 61508
and SILCL in accordance with SIL 3
IEC/EN 62061

Engineering
Performance Level (PL) in accor-
PL e

Software
dance with EN ISO 13849-1

Safety
Category in accordance with
4
EN ISO 13849
Resolution (type-dependent) 14 mm 30 mm 50 mm 90 mm
Range 0...6 m 0...18 m 0...18 m 0...18 m

Safety Laser
Protective field height
150...3000 mm
(type-dependent)

Scanners
Profile cross-section 52 mm x 55 mm
Safety-related switching output
AS-i Safety Interface
(OSSD)
Connection system M12 plug (AS-i Safety)
AS-i profile S-7.B.1, safe slave

Safety Light
Slave address 1...31, programmable (factory setting = 0)

Curtains
Cycle time in accordance with AS-i
5 ms
specifications
Current consumption from AS-i
50 mA
circuit Features
Sensor response time 10 to 66 ms

Multiple Light
Beam Safety
20...5000 ms, can be set with SafetyLab

Devices
Restart delay time software, presetting 100 ms (after protec-
tive field release)

Please note the additional information in the connecting and operating instruc-
tions at www.leuze.com/asi.

Safety Sensor
For more information go to www.leuze.com/compactplus-m and
www.leuze.com/compactplus-b.

Special features
Sets

IP 65
z Type 4 Safety Light Curtain in accordance with IEC/EN 61496-1/-2
z Integrated AS-Interface, bus connection via the AC-PDA1/A, adapter
for AS-i data transfer and separate 24-volt power supply Further information Page
z Safe data transfer of the OSSD signals via AS-Interface z Muting function package 89
Beam Safety
Single Light

z Device swap-out without PC via SERVICE function of the AS-i Safety z Blanking function package 107
Devices

Monitor z Electrical connection,


z Additional diagnostics information via AS-Interface, e.g. Muting sen- 318
see ASM1
sors status, Muting or weak signal display z Dimensional drawings 332
z Several devices can be cascaded (COMPACTplus-b) z Ordering information,
z Direct connection of Muting sensors, start/restart button or indicator 108
Safety at Work

see COMPACTplus
AS-Interface

directly on the device via sensor connection module


(COMPACTplus-m)
PROFIsafe
Sensors

www.leuze.com/asi/

333
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
AS-Interface Safety at Work
COMPACTplus/AS-i Multiple Light Beam Safety Devices

Electrical connection
Connection example, see page 318.
For more information go to www.leuze.com/asi.

Dimensional drawings

696

500

52
34 34
734
500 140.1
52

22 72
55

Dimensions in mm
Our 3D CAD models can be found under: www.leuze.com/3d-cad-models.

Ordering information
Ordering information, see Multiple Light Beam Safety Devices COMPACTplus-m, page 179.

CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net
Machine Safety
COMPACTplus/AS-i
Important technical data, overview

Machine Safety
Services
Type in accordance with
Type 4
IEC/EN 61496
SIL in accordance with IEC 61508
and SILCL in accordance with SIL 3
IEC/EN 62061

Engineering
Performance Level (PL) in accor-
PL e

Software
dance with EN ISO 13849-1

Safety
Category in accordance with
4
EN ISO 13849
Number of beams 2 3 4
Beam distance 500 mm 400 mm 300 mm

Safety Laser
Cxx0/y: 0...18 m
Range (type-dependent)
Cxx1/y: 6...70 m

Scanners
Muting Transceiver range
0...6.5 m
(type-dependent)
Profile cross-section 52 mm x 55 mm
Safety-related switching output Features
AS-i Safety Interface
(OSSD)

Safety Light
Connection system M12 plug (AS-i Safety)

Curtains
AS-i profile S-7.B.1, safe slave
Slave address 1...31, programmable (factory setting = 0)
Cycle time in accordance with AS-i
5 ms
specifications
Current consumption from AS-i

Multiple Light
50 mA

Beam Safety
circuit

Devices
Sensor response time 24 ms, 25 ms (Muting Transceiver)
20...5000 ms, can be set with SafetyLab IP 65
Restart delay time software, presetting 100 ms (after protec-
tive field release)
Further information Page
Please note the additional information in the connecting and operating instruc- z Function packages: Multiple
tions at www.leuze.com/asi. Light Beam Safety Devices with 177 Safety Sensor
For more information go to www.leuze.com/compactplus-m. Muting
z Electrical connection,
Sets

Special features see ASM1


318
z Type 4 Multiple Light Beam Safety Device in accordance with z Dimensional drawings 334
IEC/EN 61496-1/-2
z Ordering information 179
z Integrated AS-Interface, bus connection via the M12-AS-i Adapter for
Beam Safety
Single Light

AS-i data transfer and separate 24 Volt power supply


Devices

z Safe data transfer of the OSSD signals via AS-Interface


z Device swap-out without PC via SERVICE function of the AS-i Safety
Monitor
z Direct connection of Muting sensors, start/restart button or indicator
directly on the device via sensor connection module
Safety at Work
AS-Interface

z Muting restart function possible via AS-Interface by calling up AS-i-IC


parameters
z Additional diagnostics information via AS-Interface, e.g. Muting sen-
sors status, Muting or weak signal display
PROFIsafe
Sensors

www.leuze.com/asi/

335
CTi Automation - Phone: 800.894.0412 - Fax: 208.368.0415 - Web: www.ctiautomation.net - Email: info@ctiautomation.net