You are on page 1of 2

TECHNICAL DATA

WARNING AVERTISSEMENT TMNF 16/17/18/19/22


Electrical Shock Hazard Risque de choc électrique.
Failure to adhere to this important safety notice can Pub. No. 31-1000392 Rev. 1
/¶RPLVVLRQG¶REVHUYHUFHWDYLVGHVpFXULWpLPSRUWDQWSHXWHQWUDvQHUGHV
result in serious injury or death. EOHVVXUHVVpYqUHVYRLUHIDWDOHV 07-19 GEA
‡ 5HSDLUVPXVWEHSHUIRUPHGE\DTXDOL¿HG6HUYLFH • /HVUpSDUDWLRQVGRLYHQWrWUHHIIHFWXpHVSDUXQSURIHVVLRQQHOTXDOLILp
Professional. • 'pEUDQFKH]O¶DOLPHQWDWLRQpOHFWULTXHDYDQWODUpSDUDWLRQ
‡ 'LVFRQQHFWSRZHUEHIRUHVHUYLFLQJWKLVSURGXFW • 5HEUDQFKH]WRXVOHVGLVSRVLWLIVGHPLVHjODWHUUHDSUqVODUpSDUDWLRQ
‡ 5HFRQQHFWDOOJURXQGLQJGHYLFHVDIWHUVHUYLFH • 5HPHWWH]WRXWHVOHVSLqFHVHWSDQQHDX[HQSODFHDYDQWG¶XWLOLVHU
‡ 5HSODFHDOOSDUWVDQGSDQHOVEHIRUHRSHUDWLQJ l’appareil.

AIR FLOW/ EVAP FAN


ELECTRICAL SPECIFICATIONS LOKRING Connector Information CIRCULATION D’AIR
7HPSHUDWXUH&RQWURO 6HWWLQJ . . . . ƒ)    ƒ&
Defrost Control . . . . . . . . . . . . . . . . . . . . . . . . . . $GDSWLYH'HIURVW Component Size GEA Part #
NO LOAD PERFORMANCE Drier Inlet PP[PP :5;
Control Position, Setting 3
Temperature of 70°F / 21°C 90°F / 32°C Drier Outlet PP[PP :5;
11/40"
5HIULJHUDWRUƒ)ƒ&   (YDSRUDWRU,QOHW&DSLOODU\ PP[PP :5;
)UHH]HUƒ)&           
5XQQLQJ7LPH   (YDSRUDWRU,QOHW6XFWLRQ PP[PP :5;

REFRIGERATION SYSTEM (YDSRUDWRU2XWOHW PP[PP :5;


5HIULJHUDQW&KDUJH 5D . . . . . . . . . . . . . . . . . . . . refer to table Compressor Inlet PP[PP :5;
Compressor Outlet PP[PP :5;
SPÉCIFICATIONS ÉLECTRIQUES
&RPPDQGHGHWHPSpUDWXUH UpJODJH . . . . . . .    ƒ& &RPSUHVVRU3URFHVV6WXE PP[PP :5; TO CABINET WIRING BLACK/WHITE

ƒ) Condenser Inlet PP[PP :5; ORANGE


&RPPDQGHGHGpJLYUDJH . . . . . . . . . . . . . . . . 'pJLYUDJHDGDSWDWLI
RENDEMENT À VIDE Condenser Outlet PP[PP :5;
Position de commande, réglage 3 +HDW([FKDQJHU6XFWLRQ PP[PP :5; 2 RELAY
et température de 21 °C / 70 °F 32 °C / 90 °F 8 9
$OLPHQWVUpIULJpUpVƒ&ƒ)   +HDW([FKDQJHU&DSLOODU\ PP[PP :5;
$OLPHQWVVXJHOpVƒ&ƒ)           Hot Gas Loop Inlet PP[PP :5;
    9

'XUpHGHIRQFWLRQQHPHQW   Hot Gas Loop Outlet PP[PP :5;


8
CAPACITOR
SYSTÈME FRIGORIFIQUE 5D'ULHU :5;
)ULJRULJpQH 5D . . . . . . . . . . . . . . . . . . . .VHUpIpUHUjODWDEOH
5D3URFHVV9DOYH :5;
Model Charge (R600a)
*7( +3( 
*7( +36  Compressor Compressor Fan Fan Cond 6SHFL¿F7XEH6L]HV
*76 ;76  R-C S-C Capacity Evap.
Sung Bitron Capillary Line PP
*,( *7(  Shin
;7( *7(  JUDPV (YDSRUDWRU &RSSHU/LQH PP
*,( *3(  Embraco  2KP %78KU )LOWHU'ULHU PP
*,( *76  (6&& Ohm
*7( *,(  +HDW([FKDQJHU PP
-LD[LSHUD  2KP %78KU
*76 ;76 7;+< Ohm Hot Gas Loop PP
’ Ÿ ’
+36 ;36  0HL]KL(=  2KP %78KU +LJK6LGH7XEH &DVH6LGH PP
JUDPV
*76 *76 Ohm 6XFWLRQ/LQH7XEH &DVH6LGH PP
0HL]KL  2KP %78KU
(=+<8 Ohm
FAULT TABLE
Test/Function Entry Sequence Unit Response
Fault
LED Fault Code Fault Indication
Sequence Forced Defrost :KLOHFRQQHFWHGWRSRZHURSHQGRRUDQG 7KH/('OLJKWVZLOOÀDVKWLPHVDIWHUVHFRQGVWRLQGLFDWHGVXFFHVVIXOHQWU\
ZLWKLQVHFRQGVSUHVVDQGUHOHDVHWKH into Defrost mode.
1 VRQVRႇ 5HIULJHUDWRU7KHUPLVWRU
OLJKWVZLWFKWLPHV7KH/('OLJKWVZLOO
Fault 7KHGHIURVWKHDWHUZLOOHQHUJL]HLIWKHUHIULJHUDWRUZDVLQFRROLQJVWDWH
ÀDVKWLPHVDIWHUVHFRQGVWRLQGLFDWHG
 VRQVRႇ UHSHDW Defrost Thermistor successful entry into Defrost mode.
WLPHV WKHQVRႇ Fault 7KHUHIULJHUDWRUZLOOHQWHUWKH,GOH7HPSHUDWXUH&RQWUROVWDWHLIWKHUHIULJHUDWRU
was in a Dwell state or the defrost heater was ON.
 VRQVRႇ UHSHDW RUPRUHDEQRUPDO
WLPHV WKHQVRႇ defrosts 6DEEDWK0RGH Turn the control knob to the coldest 6DEEDWKPRGHZLOOWHUPLQDWHDIWHUKRXUV
SRVLWLRQ³´SUHVVDQGKROGWKHOLJKWVZLWFK
 VRQVRႇ UHSHDW Door Open <1 hour in
WXUQWKHFRQWURONQREWRSRVLWLRQWKHQ
WLPHV WKHQVRႇ ODVWKRXUV
UHOHDVHWKHOLJKWVZLWFK
No Fault 2ႇ None
6HUYLFH0RGH While the control knob is in the OFF The LEDs will turn ON for 1 second and the control board will perform a Power
SRVLWLRQSUHVVDQGKROGWKHOLJKWVZLWFK 2Q6HOI7HVW 3267 FKHFNLQJIRUIDXOWV7KH3267RSHUDWLRQWDNHVOHVVWKDQ
GREEN/
BLACK/ YELLOW ORANGE/ IROORZHGE\WXUQLQJWKHFRQWURONQREWR VHFRQGV$IWHU3267LIQRWKHUPLVWRULVVXHVH[LVWVWKHGHIURVWKHDWHULV
WHITE BLACK
SRVLWLRQWKHQUHOHDVLQJWKHOLJKWVZLWFK WXUQHG21IRUVHFRQGV6HH)DXOWWDEOHIRUIDXOWLQGLFDWLRQV

OVERLOAD PROTECTOR
(THERMAL
) COMPRESSOR
BLACK MOTOR

ORANGE/ DEFROST THERMISTOR


BROWN/ BLACK BLACK/ EVAPORATOR FAN C
WHITE THERMAL FUSE X2
WHITE

ORANGE 2 5 SEE CHART


9 R A
BROWN/
WHITE
DEFROST HEATER BLUE BROWN

PTC
RUN
CAPACITOR
BLUE/ BLUE
RED ORANGE
ORANGE BLACK S
8 6
GROUND ON PTC RELAY
EVAP BRACKET
WHITE ORANGE/
BLACK CONTROL BOARD
ORANGE ICEMAKER BLUE/
RED ORANGE
(COMPRESSOR OUT) J1-3
REFRIGERATOR BLACK EVAPORATOR CONDENSER
THERMISTOR FAN MOTOR FAN MOTOR
GREEN See Chart
A
BROWN
CONTROL
BOARD

BLACK
ORANGE

ORANGE/BLACK THERMAL FUSE BLACK


LIGHT SWITCH (DEFROST HEATER NEUTRAL) J1-8
OPEN TEMP 1710 F
DEFROST

39.68 Ÿ
HEATER
NAVY THERMAL FUSE
(DEFROST HEATER OUT) J1-1
OPEN TEMP 1710 F BLACK

POWER CORD

DOOR SWITCH SWITCH IS


BROWN
(FF SW L1 OUT) J1-5 NORMALLY
CLOSED WHEN
RED
(FF SW IN) J2-6 UN-PRESSED
(DOOR OPEN)

ORANGE
(NEUTRAL) J1-9
ORANGE
BLACK

AQUA
J2-2 (REFRIGERATOR THERMISTOR IN)
REFRIGERATOR
THERMISTOR

BROWN
CASE GROUND
NTC 16 KŸ2% @ 330 F
(AC LINE IN) J1-6
ORANGE
ICE MAKER
ORANGE TAN
J2-3 (5 VDC OUT)
WHITE
3 BLACK/ 3 6 BLUE COMPRESSOR GREEN/YELLOW
WHITE/ ORANGE
2 BLACK 2 5 ORANGE/
BLACK
1 1 4 BROWN/WHITE WHITE
BROWN J2-4 (5 VDC OUT)
THERMISTOR

CAB
DEFROST

MACHINE 187.5 ± 10 % Ÿ
Connectors shown from mating face. GREEN
CONDENSER FAN NTC 16 KŸ2% @ 330 F WATER VALVE
La face de connexion des connecteurs
est illustrée.
HARNESS CONNECTOR/
NAVY /RED
CONNECTEUR DU HARNAIS J2-1 (DEFROST THERMISTOR IN)

BROWN ORANGE

Pub. No. 31-1000392 Rev. 1 07-19 GEA