You are on page 1of 2

MONOGRAM - ZIP360NHA,

ZIPP360NHASS, ZIPS360NHASS
Technical Data
WARNING REFRIGERATION SYSTEM
Electrical Shock Hazard
Death or serious injury can result from failure to follow Compressor . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 833 BTU/hr
these instructions. Minimum Compressor Capacity
• Service by a qualified service technician only. Vacuum . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22 inches
• Disconnect power before servicing this product. Minimum Equalized Pressure
• Reconnect all grounding devices after service. @ 70°F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 62/68 PSIG
@ 90°F . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87/91 PSIG
• Replace all parts and panels before operating.
R134a Refrig. Chg. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9.25 oz

CAUTION
Suction Line
To avoid personal injury when servicing Muffler
the condensing unit, stand on a ladder which will
give enough support to allow removal of the top Process
panel and safely allow access to service the unit. Tube
Condenser

ELECTRICAL SPECIFICATIONS
Max Defrost Control
W/No Door Openings . . . . . . . . . . . . . . . . . . . . . .96 hrs @ 40 min
Evap Defrost Thermodisc . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140-110°F Inverter*

Electrical Rating: 115V AC 60 Hz . . . . . . . . . . . . . . . . . . . . . . . . 7.0 amp


Compressor Dryer
Maximum Current Leakage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 0.75 mA
Maximum Ground Path Resistance . . . . . . . . . . . . . . . . . 0.14 Ohms Muffler
Discharge

NO LOAD PERFORMANCE
CONTROL POSITION 37-0°F and
AMBIENT TEMPERATURE OF . . . . . . . . . . . 65°F . . . . . . . . . . . . 90°F
Fresh Food, °F . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36-38 . . . . . . . . . . . 36-38
Capillary
Frozen Food, °F . . . . . . . . . . . . . . . . . . . . . . . . . (-1) - (1) . . . . . . . . . . (-1) - (1)
Percent Running Time . . . . . . . . . . . . . . . . . . . 36-44 . . . . . . . . . . . 61-69 Suction Tube

REFRIGERATION DIAGNOSIS
To access the low pressure side of the system, install
a WJ56X61 valve only on the process tube extending
from the compressor case.

Evaporator
Condenser
Loop

*Approximate
location of inverter

Printed in The United States


1767S 224D3093P004 31-51903 12-14 GE
SOME OF THE LOW VOLTAGE J4 OR J16 J3 OR J10 J1 OR J14
DC CONNECTOR LABELING ON
THIS MODEL MAY DEFFER FROM
J2 OR J13
OTHER MODELS. THE

31-51903
FUNCTION AND DIAGNOSTICS
FOR THESE CONNECTORS ARE
IDENTICAL FOR ALL MODELS.
INVERTER BLACK COMPRESSOR 224D3909P005
12.4Ω 12.4Ω
RED
12.4Ω
WHITE

RETURN DUCT HEATER


EVAP TCO
R=1323Ω

INVERTER + (12 VDC)


WHITE R=38Ω
INVERTER - IM INPUT J18 OPEN 140°F
FILL TUBE HEATER

PINK
CLOSE 110°F
GEA BUS 1.323K
RED & WHITE
13.6 VDC FILL TUBER HTR 2
MONOGRAM - ZIP360NHA,

ICE MAKER 1
GND =0.15KΩ-0.35KΩ
WATER VALVE OUTPUT 3
ISO VALVE =0.15KΩ-0.35KΩ
ZIPP360NHASS, ZIPS360NHASS

MULLION HEATER 415 Ω

21.5 Ω
415 Ω

PURPLE LEFT
5 FZ LED EN
BLUE
HUMIDITY SUPPLY DUCT HEATER J8
PINK

SENSOR RET. DUCT AND DEF. HTR J9 RIGHT FF DOOR SWITCH

BROWN BLUE
SUPPLY DUCT HEATER

2
0.472K

GREEN

J 14
1 AMBIENT
AMBIENT
4 COMMON

WHITE
DELI PAN LED FZ LED

DRAIN FF
PAN
2 MODEL ID FF LEDs
7 MULLION HTR
J5
BLUE
1 PAN FAN
BROWN 3 FF/DELI PAN LED EN
VIOLET 5 +5 VDC
6 HUMIDITY (+5 VDC)
BLACK

YELLOW
224D3093P004

1767S