BASEMENT WALL REINFORCEMENT DETAILS.

HOOK VERT. REINF. 90 DEG


TO TOP OF SLAB OR
PROVIDE DOWEL
15M CONT. EDGE B15M @ 18"
10''
1' - 4"
CJ CLEAN & ROUGHEN B10M OR B15M, SEE PLAN

2-15M TOP & BOT TYP.


15M @ 10''
18" MAX. VERT. OR AS
48" SHOWN ON WALL ELEVATIONS
48"

10''
15M @ 18"
.

15M @ 15"
12'' MAX. HORIZ. OR AS
SHOWN ON WALL ELEVATIONS
12'' MIN. OR
8" MIN. OR AS
AS SHOWN
SHOWN
ON WALL ELEVATIONS
ON WALL ELEVATIONS
SHOWN ON WALL ELEVATIONS
15M 8' - 0" @ 12" MAX.
OR AS SHOWN ON 15M @ 12''
15" MAX. HORIZ. OR AS
WALL ELEVATIONS SHOWN ON WALL ELEVATIONS
3' - 9"

B10M OR B15M, SEE PLAN


1' - 6"

CJ CLEAN & ROUGHEN 2"


CLR 15M HORIZ.
6'' MAX.
15M 8' - 0" @ 12" 2-15M TOP & BOT TYP.
3/4" CLR
OR AS SHOWN ON CLR
WALL ELEVATIONS 15M @ 18"
6'' MAX. VERT. OR AS
SHOWN ON WALL ELEVATIONS
CLEAN FREE DRAINING 15M @ 15"
12'' MAX. HORIZ. OR AS
FILL COMPACTED TO 95% SHOWN ON WALL ELEVATIONS
STANDARD PROCTOR
DENSITY MIN OR REFER TO CIP FOUNDATION
DRAINAGE MEMBRANE AS SCHEDULE FOR FOOTING
REQUIRED BY OTHERS SIZE AND REINFOREMENT

1 1/2" x 3 1/2" KEY