You are on page 1of 1

REPORT OF ANALYSIS

TO WHOM IT MAY CONCERN : This is to report that we have performed the analysis of coal nominated below.
Samples Preparation, Testing and Analysis were performed at PT Triyasa Pirsa Utama in Banjarbaru in accordance with
ASTM Standard Methods.

Principal : CV. KANZANIA ALMIRA ENERGY


Attn : Mr. Jalaluddin As Sayuti
Tester For : TM, Proximate, TS And GCV
Weight of Sample : 3,75 kg
Date of Analysis : 01-Nov-21
Ref. Numbers : CBID.21.009

THE FOLLOWING SPECIFICATION IN ACCORDANCE WITH ASTM STANDARDS AND ON AIR DRIED BASIS UNLESS
OTHERWISE SPECIFIED

TM IM ASH VM FC TS CV cal/g
No SAMPEL CODE (%) (%) (%) (%) (%) (%) (%) (%) (%)
(ar) (ad) (ad) (ad) (ad) (ad) (ad) (ar) (daf)

1 KAE 25.04 9.04 7.83 33.37 49.76 0.61 6416 5287 7718

Signed for and behalf of Issued by Independent Surveyor At Loading Port


PT. TRIYASA PIRSA UTAMA Date Issued : November 01, 2021

Doni Chandra
Head of Laboratorium