X-RAY FLOURASCENT TEST REPORT

CUSTOMER ADRESS: APEX TECHNOLOGIES, SIVATEMPLE ROAD, FATHENAGAR


HYDERABAD

Work order No. TWRA/21/29 Sample ID SPECIFIED IN BELOW TABLE


Sample
Test Report No. TWRA/21/XRF/028/075 Helicoils, PO NO: 3254
description
Date of received Stainless steel (AS7245) as per
05-10-2021 Material
samples NASM8846
Date of testing 06-10-2021 Testing procedure ASTM E1621 - 21

S.N Sample ID Carbon Manganes Chromium Nickel as Result


o as ‘C’ e as as ‘Ni’
‘Mn’ ‘Cr’
Gr:AS7245 0.15 Max 2.00 max 17.00-20.00 8.00-10.50
1. M5 x 0.8 x ID -- 1.20 17.47 8.35

2. M4 x 0.7 x ID -- 1.30 18.08 8.98


conforming as per
3. M3 x 0.5 x 1.5 D -- 1.44 18.16 8.91 NATIONAL AEROSPACE
4. M10 x 1.0 x 1 D -- 1.25 17.70 9.05 STANDARD 8846
FOR HELICOILS
5. M6 x 1.0 x 1 D -- 1.49 17.43 8.30 Grade:AS7245(19Cr-9.2Ni)
6. M8 x 1.25 x 2 D -- 1.48 17.55 8.06

7. M4 x 0.7 x 1.5D -- 1.36 17.85 8.20

8 M3x 0.5 x 2D -- 1.33 17.47 9.50

RESULT: The above tested samples are meeting the specified NATIONAL AEROSPACE STANDARD 8846; GradeAS7245 (19Cr-
9.2Ni, since carbon is non metallic cannot be detected by XRF method, based on the majority of elements like Cr, Ni, & Mn grade
is conformed.

Note: Attached the system generated analytical data in annexure ‘A’

Verified by Witnessed by For Trident Welding Research & Academy

Authorized Signatory
P.NAVEEN KUMAR

Page 1 of 2
Annexure ‘A’
Test Report No: TWRA/21/XRF/028/075; Dated:06.10.2021

Sample 1 Sample 2 Sample 3

Sample 4 Sample 5 Sample 6

Sample 7 Sample 8
For Trident Welding Research & Academy

Authorized Signatory
P.NAVEEN KUMAR

Page 2 of 2

You might also like